Search PubMed⌕ Search

Biomedical subjects

P Swain

Publications and source records attributed to P Swain.

At least 19 recordsLinked to original sources

A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small-bowel lesions.

BACKGROUND & AIMS: Wireless capsule endoscopy is a new, painless method of imaging the entire small bowel. It has not been compared with push enteroscopy. We compared the sensitivity, specificity, and safety of capsule and push enteroscopy in detecting small-bowel lesions. METHODS: Nine to 13 radiopaque, colored beads (3-6 mm diameter) were sewn in random order inside 9 canine small bowels, half within the first meter, and confirmed on x-ray. After recovery, the number, order, and color of beads were assessed in 23 capsule enteroscopies and 9 push enteroscopies in a random order. The surgeons, push enteroscopists, capsule video interpreters, and pathologist were blinded to the others' findings. RESULTS: The capsules identified more beads than push enteroscopy (median, 6 [range, 2-9] vs. 3 [range, 2-6 beads]; P < 0.001). The sensitivity of the capsule was 64% compared with 37% for push enteroscopy. The specificity was 92% for capsule enteroscopy and 97% for push enteroscopy. The capsules identified significantly more beads beyond the reach of the push enteroscope (median, 4 [range, 2-7] vs. 0; P < 0.0001). Hair, ingested plastic, ulceration, submucosal swelling, and worms were clearly identified by the capsule. The capsules passed safely through the animals with no significant histologic findings. CONCLUSIONS: Wireless capsule endoscopy detected more abnormalities in the small bowel than push enteroscopy.

Animals↗

Wireless endoscopy.

BACKGROUND: Miniaturization of electronic components may allow the construction of new types of endoscopes that no longer require external wires, cables, or optical fibers. Our aim was to assess the feasibility of wireless endoscopy and to construct experimental prototypes using miniature charge-coupled device cameras, light sources, microwave transmitters, and batteries. METHODS: Feasibility, dimensions of miniature components, and power requirements were assessed. Prototypes were constructed and tested using cameras, transmitters, and halogen lamps powered by small batteries; 10.6 and 0.187 GHz transmitters were used to transmit the video signal. RESULTS: Moving television images were transmitted through models, post-mortem and live porcine stomachs, to the external receiver. Transmission of images through the abdomen was tested by placing the device in a microwave-impermeable box behind a volunteer's back and the receiver in front of his abdomen. In other experiments the endoscope was used inside the human mouth. The device was placed surgically in the stomachs of 150 kg pigs in vivo and good-quality color television image reception was achieved. CONCLUSIONS: These experiments demonstrate the feasibility of constructing a new type of endoscope that can transmit moving color television images from the GI tract without requiring fiberoptic or electrical cables.

Animals↗

Aid survey preparation with management principles.

According to guest columnist Paula Swain, RN, MSN, CPHQ, the mystique of 'survey readiness' disappears when you apply sound principles of management rather than simply reacting to the Joint Commission's notice of survey.

Accreditation↗

Monoclonal antibody based dot-enzyme linked immunosorbent assay (Dot-ELISA) and agar gel precipitation test (AGPT) for identification of Newcastle disease virus (NDV).

Two mouse monoclonal antibodies (MAbs), viz. 2B7 and 2 D10 raised against haemagglutinin-neuraminidase glycoprotein of Newcastle disease virus (NDV) were used to identify several other field isolates and vaccine strains of NDV. These MAbs reacted specifically with all the NDV strains/isolates in Dot-ELISA whereas, only MAb 2D10 reacted with all the NDV strains/isolates in agar gel precipitation test. These two tests employing the MAbs were standardised for rapid diagnosis and identification of NDV.

Animals↗

Randomised trial of single and repeated fibrin glue compared with injection of polidocanol in treatment of bleeding peptic ulcer.

BACKGROUND: Although injection treatments for ulcer haemostasis seem to be effective, recurrent bleeding remains a serious problem. Large randomised clinical trials are required to show differences between treatment modalities for gastrointestinal bleeding. The aim of this study was to compare the safety and efficacy of repeated endoscopic injection of fibrin glue (FG) with that of single endoscopic injection of polidocanol in the prevention of recurrent bleeding. METHODS: 854 patients with active gastroduodenal bleeding (spurting, oozing), or ulcers with a visible non-bleeding vessel, were randomly assigned one of three endoscopic treatments: single application of polidocanol 1%, single application of FG, or daily repeated application of FG until the visible vessel had disappeared. All patients were pretreated with local injection of epinephrine (1/10,000), and had daily repeat endoscopies until the vessel observed at initial endoscopy was no longer visible. FINDINGS: Recurrent bleeding rates among the 790 patients in whom the rates could be assessed were 58 (22.8%) of 254 in the polidocranol group, 51 (19.2%) of 266 in the FG-single group, and 41 (15.2%) of 270 in the FG-repeated group. The difference between FG-repeated treatment and polidocanol was significant (p = 0.036). Treatment failed, making other treatments (including surgery) necessary, in 34 (13.0%) of 261 in the polidocanol group, 34 (12.4%) of 274 in the FG-single group, and 21 (7.7%) of 274 in the FG-repeated group. The difference between FG-repeated treatment and polidocanol was significant (p = 0.046). The 30-day-mortality rates were low in all three treatment groups (polidocanol 4.7%; FG-single treatment 5.3%, FG-repeated treatment 4.3%). The safety profiles of the three treatment strategies were similar. INTERPRETATION: Repeated injection with FG glue is significantly more effective than injection with polidocanol 1% in the treatment of bleeding from gastroduodenal ulcers.

Adult↗

Down-regulation of poison ivy/oak-induced contact sensitivity by treatment with a class II MHC binding peptide:hapten conjugate.

Immune regulation of contact sensitivity to the poison ivy/oak catechol was studied at the level of class II MHC-restricted T cell recognition of hapten:peptide conjugates. In this study we have shown that 1) T cells from C3H/HeN (H-2k) mice, immunized with a synthetic I-Ak binding peptide coupled to 3-pentadecyl-catechol (PDC; a representative catechol in urushiol), recognized peptides derived from syngeneic cells linked to the same catechol; 2) T cells from draining lymph nodes of C3H/HeN mice skin-painted with PDC proliferated in response to a peptide carrier:PDC conjugate only when it was linked at the 7th, but not the 4th or the 10th, position on the peptide carrier; and 3) tolerization studies confirmed down-regulation of PDC-induced delayed-type hypersensitivity following treatment with a single I-Ak binding peptide carrying PDC covalently bound to a lysine residue at the middle (7th) TCR contact position. Tolerization with peptide:PDC conjugate resulted in abrogation of hapten-specific T cell proliferative responses that correlated with diminished IL-2 secretion. On the basis of these data we propose that it may be sufficient to couple the hapten at a single, well-chosen position on a carrier peptide to target a relevant population of T cells involved in contact sensitivity.

Administration, Topical↗

Cutting thread at flexible endoscopy.

BACKGROUND: New thread-cutting techniques were developed for use at flexible endoscopy. A guillotine was designed to follow and cut thread at the endoscope tip. A new method was developed for guiding suture cutters. Efficacy of Nd: YAG laser cutting of threads was studied. Experimental and clinical experience with thread-cutting methods is presented. METHODS: A 2.4 mm diameter flexible thread-cutting guillotine was constructed featuring two lateral holes with sharp edges through which sutures to be cut are passed. Standard suture cutters were guided by backloading thread through the cutters extracorporeally. A snare cutter was constructed to retrieve objects sewn to tissue. Efficacy and speed of Nd: YAG laser in cutting twelve different threads were studied. RESULTS: The guillotine cut thread faster (p < 0.05) than standard suture cutters. Backloading thread shortened time taken to cut thread (p < 0.001) compared with free-hand cutting. Nd: YAG laser was ineffective in cutting uncolored threads and slower than mechanical cutters. Results of thread cutting in clinical studies using sewing machine (n = 77 cutting episodes in 21 patients), in-vivo experiments (n = 156), and postsurgical cases (n = 15 over 15 years) are presented. CONCLUSIONS: New thread-cutting methods are described and their efficacy demonstrated in experimental and clinical studies.

Animals↗