[The electrocardiogram after left ventricular aneurysmectomy. Study of patients with post-infarction aneurysm].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to P Stassano.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Two patients experienced an episode of massive air embolism during extracorporeal circulation. Several emergency measures were taken. (1) The roller pump was reversed to take out air from the aorta. (2) The circuit was disconnected and recirculated to eliminate air bubbles. (3) Perfusion was restarted and the patient cooled to 24 degrees C for 40 minutes. (4) Pentothal (thiopental), steroids, and assisted ventilation were administered. The outcome was favorable in both patients, and there were no neurological sequelae. Immediate cooling and prolonged circulation seem to be a satisfactory approach to this problem.
Prosthetic valve endocarditis (PVE) remains an uncommon but serious complication of cardiac valve replacement. We analysed several risk factors (active or healed, early or late endocarditis, congestive heart failure, arterial emboli etc.) in order to identify the factors which may predict bad outcome. The overall mortality rate was 46.8% (15/32 patients). There was a significantly higher mortality rate in patients with early endocarditis (80%) than in those with late endocarditis (38%) (p less than 0.01). In the group of patients who underwent reoperation, the mortality rate was higher in those with active endocarditis (70%) than in those with healed endocarditis (28.5%) (p less than 0.05). We believe that combined medical and surgical treatment is the best management for bioprosthetic valve endocarditis, with the institution of appropriate preoperative antibiotic therapy, to attempt to achieve sterilization.
In coronary artery surgery, when a poor distal run of can predict an early graft failure, it might be useful to perform the last anastomosis to a low pressure chamber thus creating a small arterio-venous (A-V) fistula. From January throughout December 1984, 4 patients underwent coronary angiography for severe symptoms of angina. The coronary angiography showed multiple stenoses on the left anterior descending (LAD), ventricular branches of the circumflex (CX), and posterior descending of the right coronary artery (PD). At operation the patients received a sequential aortocoronary bypass graft with reversed saphenous vein, plus the creation of a small A-V fistula into the right atrium in order to improve the graft flow and patency. All patients experienced a clinical improvement. No adverse effects have been observed and the patients, controlled clinically with non invasive and in two cases with invasive techniques, showed satisfactory revascularization.
An unusual complication of the median sternotomy is reported. A 37-year-old male experienced a left innominate vein thrombosis 20 months after surgery. The combined treatment consisting of local infusion with Urokinase, surgical removal of the wire and balloon catheter dilatation, was completely successful.
Bovine pericardial bioprostheses (BPB), such as the Ionescu-Shiley or the Vascor, and low-profile porcine bioprostheses (Liotta, LPB) have particular features that make them useful in certain anatomical situations, such as aortic stenosis with hypoplastic annulus, pure mitral stenosis with little ventricle and double valvular stenosis with hypertrophic ventricular wall. In such situations, the use of traditional porcine bioprostheses causes problems. We report our experience with BPB and LPB in 25 cases of double valvular stenosis. Operative results were fairly good, and, with the excellent mid-term follow-up by 2-D echo and haemodynamic evaluation, the present authors are confident that these bioprostheses can be considered to be a good alternative to traditional ones and the first choice in particular anatomical situations.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A case with marked factor VII deficiency, undergoing open heart surgery for atrial myxoma, is reported. The syndrome was unknown to the patient and only pre-operative routine coagulation studies showed a low prothrombin activity (22%). Further investigations revealed a severe factor VII deficiency. The operation was carried out under factor VII concentrate administration and no bleeding complication occurred.
Explore the source record for details and available documents.
False aneurysm from the aortic vent site is an uncommon complication following open heart surgery. An ascending aorta false aneurysm developed in a patient four months after mitral and aortic valve replacement. Extensive adhesions precluded aortic dissection and cross-clamping. Femoro-femoral cannulation, low flow, low pressure, and low temperature cardiopulmonary by-pass was used. The aneurysm was resected and then repaired with a Dacron patch. A Foley catheter was placed in the ascending aorta through the defect to obtain a bloodless field. This surgical approach can be useful in managing this difficult situation.