Search PubMed⌕ Search

Biomedical subjects

P Scott Carney

Publications and source records attributed to P Scott Carney.

10 recordsLinked to original sources

Inverse scattering for optical coherence tomography.

Inverse scattering theory for optical coherence tomography (OCT) is developed. The results are used to produce algorithms to resolve three-dimensional object structure, taking into account the finite beam width, diffraction, and defocusing effects. The resolution normally achieved only in the focal plane of the OCT system is shown to be available for all illuminated depths in the object without moving the focal plane. Spatially invariant resolution is verified with numerical simulations and indicates an improvement of the high-resolution cross-sectional imaging capabilities of OCT.

Algorithms↗

Eikonal method for calculation of coherence functions.

A method is presented for computing the cross-spectral density of a special class of partially coherent fields in which the coherent modes obey an eikonal equation. This method allows for statistical analysis of optical systems based on simple ray tracing.

Journal Article↗

Near-field diffractive elements.

A novel near-field imaging system is proposed and simulated. It is seen that a significant improvement in performance in the presence of noise is possible without loss of resolution.

Journal Article↗

Computational lens for the near field.

A method is presented to reconstruct the structure of a scattering object from data acquired with a photon scanning tunneling microscope. The data may be understood to form a Gabor type near-field hologram and are obtained at a distance from the sample where the field is defocused and normally uninterpretable. Object structure is obtained by the solution of the inverse scattering problem within the accuracy of a perturbative, two-dimensional model of the object.

Journal Article↗

Information content of the near field: two-dimensional samples.

Limits on the effective resolution of many optical near-field experiments are investigated. The results are applicable to variants of total-internal-reflection microscopy (TIRM), photon-scanning-tunneling microscopy (PSTM), and near-field-scanning-optical microscopy (NSOM) in which the sample is weakly scattering and the direction of illumination may be controlled. Analytical expressions for the variance of the estimate of the complex susceptibility of an unknown two-dimensional object as a function of spatial frequency are obtained for Gaussian and Poisson noise models, and a model-independent measure is examined. The results are used to explore the transition from near-zone to far-zone detection. It is demonstrated that the information content of the measurements made at a distance of even one wavelength away from the sample is already not much different from the information content of the far field.

Journal Article↗

Projected index computed tomography.

Projected index computed tomography (PICT) is a new imaging technique that provides a computed reconstruction of the index of refraction of a sample. PICT makes use of data from standard optical coherence tomography images taken from several view angles to determine a mapping of the refractive indices of the sample. A rectilinear propagation model is assumed, so the data are understood to be related to the line integral of the refractive index in the beam paths. These data thus provide a set of angular projections of the sample. The spatial distribution of the index of the object may then be reconstructed by use of standard filtered backprojection techniques. The resultant PICT images are free of the spatial distortion that is inherent in standard optical cross-sectional images and correspond well to the manufactured dimensions of specific samples.

Image Processing, Computer-Assisted↗

Theory of total-internal-reflection tomography.

A method is presented to reconstruct three-dimensional tomographic images of weakly scattering objects with subwavelength resolution. The method may be applied to data available in phase-sensitive, total-internal-reflection microscopy. The results follow from an analysis of the near-field inverse scattering problem with evanescent waves.

Journal Article↗

Adaptive spectral apodization for sidelobe reduction in optical coherence tomography images.

Often in imaging systems, the bandpass of the system is not uniform. In temporal coherence imaging methods such as optical coherence tomography, one would like to achieve the most spatially confined impulse response possible with a given source spectrum, minimizing sidelobes that blur adjacent features together. Typically the spectrum of the source is controlled in order to remove sidelobes from the measured interferogram. However, the measured interferogram is not necessarily the best estimate of the scattering density of the object. In this work, a sidelobe supression method is proposed and demonstrated to achieve low sidelobes even with highly nonuniform, non-Gaussian spectra.

Algorithms↗