Publications and source records attributed to P Schor.

9 recordsLinked to original sources

PTTL method applied to UV radiation detection during refractive surgery using excimer laser.

The method of phototransferred thermoluminescence (PTTL), using CaSO(4):Dy pellets produced at IPEN as sensitive material, was used to detect the spread laser radiation inside the surgery room during refractive surgical procedures using ArF excimer lasers. The purpose of this work was to study the viability of performing the ultraviolet radiation (UVR) exposure detection of patients and the hospital's surgical staff during a refractive surgery. The CaSO(4):Dy pellets were positioned at different distances from the laser source inside the surgery room: patient's ( congruent with 0.15 m), surgeon's ( congruent with 0.5 m) and nurse's ( congruent with 1.0 m) foreheads, lateral ( congruent with 1.5 m) and back ( congruent with 4.0 m) walls. The measurements of PTTL were carried out at two different conditions: five surgeries, each one taking approximately 10 min, and during a period of 4 h (cumulative), when several operations were performed. The detectors positioned as far as 4.0 m from the UV laser source were sensitised, making the UVR detection feasible at large source-detector distances. The absorbed energy was detected in the range from 40 microJ to 30 mJ during a surgery. This result indicates that the method studied can be used to detect the spread UVR.

Body Burden↗

A clinical follow up of PRK and LASIK in eyes with preoperative abnormal corneal topographies.

AIM: To assess the safety and predictability of photorefractive keratotomy (PRK) and laser in situ keratomileusis (LASIK) based on preoperative corneal topography. METHODS: A non-randomised comparative study was carried out on 84 eyes that presented with topographic abnormalities before undergoing PRK (n = 44) or LASIK (n = 40) procedures. 84 spherical equivalent paired normal eyes served as the control group. Either PRK or LASIK procedures were performed on 168 eyes using the Summit apex plus excimer laser. Topographic abnormalities, including apex displacement (AD), increased asphericity (AS), meridional irregularity (MI), increased inferior-superior asymmetry (IS), increased curvature (CU), and combined features (CO), were assessed preoperatively using the EyeSys analysis system. Safety and predictability of the two procedures were defined as a postoperative visual acuity of 20/40 or better and the loss of one or more lines of spectacle corrected visual acuity (SCVA). RESULTS: All patients were followed for 6 months. There was a significant loss of best corrected visual acuity in the PRK-AD (p<0.001), PRK-CO (p<0.05), and LASIK-AS (p<0.001) patients. The number of eyes within plus or minus 1.0D of the surgical plan postoperatively was similar in all groups. CONCLUSION: These data suggest that although predictability was similar, PRK and LASIK performed in corneas with topographic abnormalities might cause loss of vision.

Corneal Diseases↗

Myopic angle-supported intraocular lenses: two-year follow-up.

OBJECTIVE: To evaluate clinical and refractive results of myopic angle-supported intraocular lenses (IOLs). DESIGN: Prospective, noncomparative case series. PARTICIPANTS: Twenty-one eyes of 12 patients (7 female) with a mean age of 29.5 years and a follow-up of 24 months. The prospective study included highly myopic eyes (more than -11.00 diopters [D]) with spectacle-corrected visual acuity better than 20/200. METHODS: Twenty-one eyes underwent implantation of a single-piece IOL with Z-shaped haptics for angle support (each haptic with two footplates) and an optical zone of 4.5 mm (NuVita, Bausch & Lomb Surgical, Irvine, CA). The dioptric power of the IOL was calculated considering refraction, keratometry, and anterior chamber depth (specific nomogram), and its diameter was determined by adding 0.5 mm to the corneal diameter. MAIN OUTCOME MEASURES: We evaluated the following clinical and refractive data: visual acuity without and with correction (VAsc and VAcc), spherical equivalent (SE) obtained under cycloplegia, slit-lamp biomicroscopy, keratometry, applanation tonometry, endothelial cell count, ultrasound pachymetry, gonioscopy, indirect ophthalmoscopy, subjective complaints, and descriptions of complications. RESULTS: Mean postoperative VAsc was 20/74. Mean preoperative VAcc (20/50) increased to 20/30; 65% gained at least two lines of VAcc, and no eye had a decrease in VAcc. Preoperative SE (-18.95 D) evolved to -2. 06 D, stabilizing after one month. Iris retraction (pupil ovalization) more than 0.5 mm was noted in eight eyes (40%). Mean keratometry, corneal astigmatism, and ultrasound pachymetry were stable during the study (P > 0.01). Significant endothelial cell loss was demonstrated in the second year. Gonioscopy showed 70 (87. 5%) footplates ideally positioned with no iris depression. Reports of glare and haloes in dark environment were considered light in 80% and not referred in 20%, and spectacles were used for residual refraction in 75%. Intraocular lens exchange was needed in one eye because of undersizing, and the IOL was removed in one eye because of chronic inflammatory reaction associated with ocular hypertension (this patient was excluded from the statistical analysis). CONCLUSIONS: This report demonstrates good efficacy for correction of high myopia by the phakic IOL used during the two years of follow-up. Long-term complications (safety) such as iris retraction and endothelial cell loss remain a concern.

Adult↗

HIV-antibody detection in vitreous humor and serum by enzyme immunosorbent assay and particle agglutination test.

PURPOSE: To compare enzyme immunosorbent assay (EIA) and the particle agglutination (PA) test for the detection of antibodies to the human immunodeficiency virus (HIV) in cadaveric vitreous humor and serum. METHODS: Seventeen cadavers presenting pathologic signs of acquired immunodeficiency syndrome (AIDS) at autopsy and 33 without AIDS signs were evaluated. Consistency (k) and significance (p) between the diagnostic tests were established. RESULTS: The right and left eyes of each of 48 bilaterally tested cadavers presented identical diagnostic results in all laboratory tests. All tests were positive for antibodies in the AIDS cadavers except for two EIA-negative vitreous results. Three autopsy-negative cadavers showed by both EIA and PA testing positive results in serum and negative in vitreous. Two of them showed a serum-positive Western blot. CONCLUSION: Serum EIA anti-HIV antibody detection test is the current gold standard for evaluating corneal donor material. Neither the PA test nor EIA should be used for vitreous testing because of their low sensitivity.

Adult↗

Advanced techniques: developing quality drawings.

Just like writing, developing ideas for illustrating your articles is a skill you can learn. With creativity, planning, and a cooperative relationship with a graphic artist you can include drawings that enhance your reader's appreciation of every publication you write.

Art↗

Effect of differences in binocularity on perceived absolute distance.

1. Using a 0.9 x 4.0 m visual alley, perceived absolute distance was studied in four groups of subjects: binocular, cross-eyed, monocular, and induced-monocular individuals. 2. A power function between the different physical and perceived distances was adjusted and the relative and absolute errors made by the observers were calculated. Despite a tendency to overestimate distance in the monocular group, no significant differences were detected among groups. 3. The data suggest that, under natural-cue conditions, binocularity is not a determining factor for the perception of absolute distance.

Distance Perception↗

Calibration of trephine blade depth.

PURPOSE: To assess the accuracy and precision of the Barron radial vacuum trephine as an instrument for corneal lamellar dissection. METHODS: We describe a practical method to calibrate individual trephines prior to lamellar corneal procedures using the calibration microscope designed for diamond knives. RESULTS: We observed that one turn (360 degrees) of the trephine produced a mean blade displacement of 0.25 mm. However, individual trephines demonstrated a significant range of variability. CONCLUSION: For highly accurate trephination, it is useful to calibrate each individual trephine using the calibration microscope.

Calibration↗

Factors affecting corneal strip stroma-to-stroma adhesion.

BACKGROUND: Successful laser in situ keratomileusis depends on strong adhesion between the dissected anterior corneal flap and the underlying stromal bed, without suturing. This study attempts to generate new information about the mechanism of this adhesion. METHODS: Strips of fresh bovine corneal stroma were dissected and split apart. The split strips were then made to adhere to each other with varying amounts of combined heat and drying. A relationship was developed between heat applied and hydration of strips. After each heat and drying treatment, the strips were pulled apart and the force needed to accomplish this task was measured. RESULTS: There was a tight linear correlation between increase in temperature and decrease in water content (R2 = 0.7414) and between decrease in water content and increase in the adhesive force (R2 = 0.3355). CONCLUSION: This model suggests that drying increases stromal-stromal adhesion. We speculate this is due to the increased concentration of surface molecules, which have high ionic charge densities and ionic bonding. A higher concentration of these molecules produces stroma-to-stroma adhesion via ionic bonding.

Adhesiveness↗