Search PubMed⌕ Search

Biomedical subjects

P S Rezentes

Publications and source records attributed to P S Rezentes.

2 recordsLinked to original sources

Mammography grid performance.

PURPOSE: To measure directly the grid performance of mammography units for the range of breast thicknesses and x-ray tube potentials encountered in clinical practice. MATERIALS AND METHODS: Contrast improvement factors and Bucky factors were determined for four mammographic units as a function of x-ray tube potential (25, 30, and 35 kVp), phantom thickness (2, 4, and 8 cm) and, on one unit, three target-filter combinations. Three units used a linear grid; one, a cellular grid. Two methods were used for nongrid measurements. RESULTS: For all units tested, contrast improvement factor increased with increased phantom thickness and with increased kilovolt peak level for the 8-cm-thick phantom and changed little with kilovolt peak level for 2- and 4-cm-thick phantoms. At 25 and 30 kVp, contrast improvement factor performance with the linear grids was comparable; with the cellular grid, it was 5%-10% higher. In all cases, the Bucky factor increased with increased phantom thickness and decreased with increased tube potential. CONCLUSION: Differences in grid performance exist. At 25 and 30 kVp, the cellular grid exhibited superior contrast improvement factor performance, whereas one of the linear grids exhibited superior Bucky factor performance. Measured contrast improvement and Bucky factors are dependent on nongrid technique. Cassette tunnels introduce scatter and should not be used with nongrid or magnification techniques.

Humans↗

The relationship between pixel value and beam quality in photostimulable phosphor imaging.

Direct digital capture systems are relatively new in diagnostic imaging. Full utilization of these devices requires a thorough understanding of the image formation process. The conversion of x-ray photon energy to a digital pixel value in a commercially available photostimulable phosphor (PSP) imaging system is investigated in this paper. Pixel values measured at 16 different combinations of 4 x-ray beam peak voltages (60, 80, 100, and 120 kVp) and 4 beam qualities are reported. At 60 and 80 kVp exposures were made at 2.58 x 10(-7) C/kg (1 mR); at 100 and 120 kVp exposures were made at 5.16 x 10(-7) C/kg (2 mR). Analysis of variance was used to determine the statistical significance of the relationship between pixel value and beam quality for a given kVp and exposure. A computer model accounting for x-ray spectral effects that accurately predicts pixel value is presented. Calculated pixel value agree within 5.0% of measured values over the range of beam energies, exposures, and qualities.

Analysis of Variance↗