Search PubMed⌕ Search

Biomedical subjects

P Rogalla

Publications and source records attributed to P Rogalla.

At least 19 recordsLinked to original sources

Successful endovascular treatment of infrarenal aortic rupture after chemotherapy of a mesenchymal periaortic tumor.

PURPOSE: To report the first successful endovascular repair of a non-aneurysmal aortic rupture due to periaortic tumour regression. CASE REPORT: A 58-year-old man developed spontaneous infrarenal aortic rupture following chemotherapy which led to regression of a periaortic mesothelioma that had been diagnosed during explorative laparotomy 11 months earlier. Stent-graft placement was performed with intentional conversion of a bifurcated (Zenith, COOK) into an aorto-uni-iliac system. No complications were encountered during a 40 months follow-up. CONCLUSION: Endovascular repair should be considered as a treatment option in non-aneurysmal aortic rupture.

Antineoplastic Agents↗

[Multislice computed tomographic myelography].

While magnetic resonance imaging (MRI) is the first line modality in depicting intramedullary spinal lesions, computed tomographic (CT) myelography has gained renewed attention due to the introduction of multislice scanning (MS-CT). Compared with conventional CT, MS-CT permits rapid, high-resolution imaging of various spinal pathologies with extended scan length. Although soft tissue contrast is inferior to that with MRI, MS-CT myelography performs best in detailed assessment of osseous pathologies, 3D imaging of orthopedic and anesthesiologic implants, and showing dural leakage and causes of CSF circulation impairment. Whenever MRI is not available or contraindicated, MS-CT myelography is the method of choice for evaluating spinal lesions.

Anatomy, Cross-Sectional↗

[Endovascular therapy of non-aneurysmatic infrarenal aortic rupture].

INTRODUCTION: Endovascular therapy is being used increasingly also to treat ruptured infrarenal aortic aneurysms. Non-traumatic rupture of non-aneurysmatic infrarenal aorta is an absolute rarity. METHODS: The feasibility of endovascular repair of infrarenal aortic rupture is demonstrated with a case history and a literature review. RESULTS: A 58-year-old male developed spontaneous rupture of his infrarenal aorta after successful chemotherapy resulting in regression of a periaortic tumor. The patient suffered from a sepsis for several days before aortic rupture was discovered during computed tomography for focus search. Immediate endovascular stent-graft repair was performed under emergency conditions. There is no recurrence and the patient is doing well with the stent-graft in place without any pathological finding after a follow-up of 24 months. So far only three further cases have been reported of endovascular repair for penetrating atherosclerotic ulcer with rupture of the infrarenal aorta. DISCUSSION: This is the first report of endovascular repair of aortic rupture due to successful chemotherapy of a periaortic mesothelioma. Furthermore, this is the fourth case of successful stent-graft placement to treat non-aneurysmatic rupture of the infrarenal aorta. Minimally invasive endovascular therapy should become a standard treatment option for aortic rupture.

Angioplasty, Balloon↗

Image guided respiratory gated hypofractionated Stereotactic Body Radiation Therapy (H-SBRT) for liver and lung tumors: Initial experience.

To evaluate our initial experience with image guided respiratory gated H-SBRT for liver and lung tumors. The system combines a stereoscopic x-ray imaging system (ExacTrac X-Ray 6D) with a dedicated conformal stereotactic radiosurgery and radiotherapy linear accelerator (Novalis) and ExacTrac Adaptive Gating for dynamic adaptive treatment. Moving targets are located and tracked by x-ray imaging of implanted fiducial markers defined in the treatment planning computed tomography (CT). The marker position is compared with the position in verification stereoscopic x-ray images, using fully automated marker detection software. The required shift for a correct, gated set-up is calculated and automatically applied. We present our acceptance testing and initial experience in patients with liver and lung tumors. For treatment planning CT and Fluorodeoxyglucose-Positron Emission Tomography (FDG-PET) as well as magnetic resonance imaging (MRI) taken at free breathing and expiration breath hold with internal and external fiducials present were used. Patients were treated with 8-11 consecutive fractions to a dose of 74.8-79.2 Gy. Phantom tests demonstrated targeting accuracy with a moving target to within +/-1 mm. Inter- and intrafractional patient set-up displacements, as corrected by the gated set-up and not detectable by a conventional set-up, were up to 30 mm. Verification imaging to determine target location during treatment showed an average marker position deviation from the expected position of up to 4 mm on real patients. This initial evaluation shows the accuracy of the system and feasibility of image guided real-time respiratory gated H-SBRT for liver and lung tumors.

Aged↗

[Intrathecal misplacement of an interscalene plexus catheter].

For perioperative anesthesia in a case of shoulder arthroscopy, a continuous interscalene plexus block according to Meier was performed in a 51-year-old female patient. The catheter was placed after stimulator-assisted punction and application of a local anesthetic. A few minutes after a further dose of local anesthetic was given via the catheter, the patient had to be intubated and ventilated with signs of total spinal anesthesia. The cervical CT showed the intrathecal displacement of the catheter, reaching the spinal canal near the root of the 7th spinal nerve. Blind advancement and deep placement increase the risk of an abnormal catheter position. Intraspinal misplacement should be reliably excluded.

Anesthesia, Spinal↗

[Surgery for congestive heart failure--the role of computed tomography in the pre- and postoperative diagnostic evaluation].

The treatment of advanced, drug resistant congestive heart failure gains in importance in the field of cardiac surgery. Cardiac imaging for preoperative assessment and follow-up focuses on the determination of ventricular volumes and function as well as on the detection of postoperative complications. Computed tomography (CT) is highly accurate irrespective of the individual patient's anatomic situation, has a low examiner dependence and short examination time, does not require an arterial vascular access and can be performed in patients with metal implants. CT is the modality of choice in the follow-up of heart transplants to detect extracardiac and cardiac complications including coronary calcifications as an early sign of transplant vasculopathy. In addition, CT visualizes the elements of mechanical assist devices and can identify their possible local cardiac and mediastinal complications. CT can detect fibrolipomatous involution of the mobilized muscle flap in dynamic cardiomyoplasty and can depict fibrous reactions along the epicardial mesh implant in passive cardiac containment. Further indications include assessment of typical local postoperative complications, such as intrathoracic infection and mediastinal bleeding, intracardiac thrombus formation or pericardial effusion. CT is routinely used for evaluating bypass patency but is limited in assessing associated valve defects since it does not visualize flow.

Cardiovascular Surgical Procedures↗

Posterior "nutcracker" phenomenon: hemodynamic relevant aorto-retroaortal renal vein fistula leading to fatal right heart failure.

A rare complication of an aneurysm of the abdominal aorta is the so-called "posterior nutcracker phenomenon", which describes compression of a retroaortal renal vein between the abdominal aorta and the vertebral column. The clinical presentation is flank pain and hematuria, which are usually caused by a renal (respectively ureteral) calculus or neoplasia. Another rare differential diagnosis for these very common clinical symptoms is an aorto-left renal vein fistula (ALRVF), which is a spontaneous vascular fistula, usually also associated with an aortic aneurysm, infrequently a result of abdominal trauma.

Aged↗

Small bowel involvement in Crohn's disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis.

BACKGROUND: Wireless capsule endoscopy (WCE) offers endoscopic access to the small bowel and may therefore change diagnostic and therapeutic strategies in small bowel diseases. AIM: The aim of this prospective study was to validate the gain in information and therapeutic impact of WCE in patients with Crohn's disease. METHODS: Fifty six consecutive patients with Crohn's disease underwent computed tomography (CT) enteroclysis, and if stenoses <10 mm were excluded, WCE was carried out. RESULTS: In 15 patients (27%), WCE could not be performed due to strictures detected by CT enteroclysis. From the other 41 patients, jejunal or ileal lesions were found in 25 patients by WCE compared with 12 by CT enteroclysis (p=0.004). This gain in information was mainly due to detection of small mucosal lesions such as villous denudation, aphthoid ulcerations, or erosions. Both methods were not significantly different in the detection of lesions in the terminal/neoterminal ileum (WCE 24 patients, CT enteroclysis 20 patients). Therapy was changed due to WCE findings in 10 patients. Consecutively, all of them improved clinically. CONCLUSIONS: Capsule endoscopy improves the diagnosis of small bowel Crohn's disease. This may have significant therapeutic impact.

Adult↗

Aspects of computer-aided detection (CAD) and volumetry of pulmonary nodules using multislice CT.

With the superb spatial resolution of modern multislice CT scanners and their ability to complete a thoracic scan within one breath-hold, software algorithms for computer-aided detection (CAD) of pulmonary nodules are now reaching high sensitivity levels at moderate false positive rates. A number of pilot studies have shown that CAD modules can successfully find overlooked pulmonary nodules and serve as a powerful tool for diagnostic quality assurance. Equally important are tools for fast and accurate three-dimensional volume measurement of detected nodules. These allow monitoring of nodule growth between follow-up examinations for differential diagnosis and response to oncological therapy. Owing to decreasing partial volume effect, nodule volumetry is more accurate with high resolution CT data. Several studies have shown the feasibility and robustness of automated matching of corresponding nodule pairs between follow-up examinations. Fast and automated growth rate monitoring with only few reader interactions also adds to diagnostic quality assurance.

Diagnosis, Differential↗

[CT fluoroscopy].

Percutaneous biopsy of pulmonary nodules requires precise needle placement, with the goal of attaining a secure position of the needle for therapeutic or diagnostic purposes as quickly as possible and with minimal tissue damage along the access route. The requirements from the image guidance system during the intervention are, in addition to universal applicability, a quick reaction time and a user-friendly interface. CT fluoroscopy fulfils these requirements, although radiation protection for the patient and radiologist becomes an important issue.

Biopsy, Needle↗

Multislice CT coronary angiography: evaluation of an automatic vessel detection tool.

PURPOSE: To investigate the potential of a new detection tool for multislice CT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. MATERIALS AND METHODS: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (> or = 50 %) in all segments of > or = 1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. RESULTS: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94 %, 89 vs. 84 %, 6 vs. 6 %, and 89 vs. 88 %, respectively (p = n. s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143 +/- 30 vs. 146 +/- 24 mm, r = 0.923, p < 0.001), left circumflex (94 +/- 35 vs. 93 +/- 33 mm, r = 0.945, p < 0.001), and right coronary artery (145 +/- 36 vs. 144 +/- 37 mm, r = 0.925, p < 0.001). The time required to create reformations along the coronary arteries was significantly shorter with the automatic tool compared to the manual approach (203 +/- 77 vs. 391 +/- 104 sec, p < 0.005). In 90 % of the coronary branches automatic detection required less time than the manual approach. CONCLUSION: Automatic coronary vessel detection is feasible and reduces the time required to create reformations by a factor of approximately two without deteriorating the diagnostic accuracy.

Aged↗

[Value of electron beam tomography (EBT)].

Electron beam tomography (EBT) has been scientifically evaluated to a much lesser degree for non-cardiac indications than for cardiac purposes. Therefore, four groups of investigators in Berlin (2), Mannheim and Munchen, which were supported by the Deutsche Forschungsgemeinschaft (DFG), included applications outside the heart in their evaluation of EBT technology. EBT has proven useful to look for pulmonary embolism and to assess other vessels (aorta, aortic branches, and intracranial arteries). Imaging of the lung parenchyma benefits from its intrinsic high contrast and from the fast data acquisition of EBT. Limited photon efficiency, higher radiation exposure, increased noise levels and other artifacts, however, markedly reduce the value of EBT for imaging of low contrast objects compared to conventional spiral CT and multislice CT (MSCT), compromising, in particular, the morphologic depiction of parenchymal abdominal organs and the brain. Consequently, scientific studies to further evaluate EBT for scanning of the brain and parenchymal abdominal organs were not pursued. Radiation exposure for non-cardiac EBT studies is up to three times higher than that for respective spiral CT studies, and in children EBT can only be advocated in select cases. Radiation exposure for the various prospectively triggered cardiac examination protocols of EBT is lower than that for conventional coronary angiography. Radiation exposure in cardiac multislice CT exceeds severalfold that of EBT, but the dose efficiency of EBT and MSCT are similar due to higher spatial resolution and less image noise of MSCT. In addition, modifications of MSCT (ECG pulsing) can further reduce radiation exposure to the level of EBT. Technical improvements of the EBT successor scanner "e-Speed" enable faster data acquisition at higher spatial resolution. Within comparative studies, the "e-Speed" will have to prove its value and competitiveness, particularly in comparison with multislice CT. After profound scientific assessment in a multicenter evaluation supported by the Deutsche Forschungsgemeinschaft (DFG) and regardless of the specific suitability of electron beam tomography for various cardiac and some non-cardiac indications, the investigators unanimously find the electron beam tomograph Evolution C150 XP not suitable as a whole body CT scanner.

Age Factors↗

[Diagnostic value of electron-beam computed tomography (EBT). I. Cardiac applications].

Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages, not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart.

Adult↗

[Ultra-low-dose CT to search for stones in kidneys and collecting system].

Unenhanced computed tomography (CT) has a sensitivity of 97.7 to 100 % for the detection of urolithiasis. Using a modified examination protocol, the radiation exposure of a CT examination can be reduced to the level of a single conventional radiographic view of the abdomen (ultra-low-dose CT), assuming the examination is performed on a modern multirow CT. Automatic postprocessing of thin-section images can delineate stones on coronal images. In 30 patients, ultra-low-dose CT could detect more stones (6 renal and 19 ureteral stones) than ultrasonography.

Adult↗