Search PubMed⌕ Search

Biomedical subjects

P Reinhard

Publications and source records attributed to P Reinhard.

At least 19 recordsLinked to original sources

Longitudinal monthly body measurements from 1 to 12 months of age: a study by practitioners for practitioners. Zurich Association of Practicing Paediatricians.

UNLABELLED: A longitudinal growth study with monthly measurements during the 1st year of life was conducted by nine paediatricians working in private practice in Zurich. Of 92 children, none was lost to the study and only 32 of 1104 planned visits were missed; the quality of the measurements was comparable to that of a specialised university clinic. Compared to the Zurich Longitudinal Growth Studies, children of this study were considerably heavier and taller. In 92% of the subjects, growth velocity was at least once outside the reference range (3rd 97th percentile). For weight increments, the corresponding proportion was 87%. CONCLUSIONS: The data indicate that current standards for the 1st year of life for the Zurich area might no longer be appropriate and need to be updated. The currently used velocity percentiles based on 3-monthly measurements are not suitable to assess individual height and weight increments calculated from monthly measurements.

Anthropometry↗

Selenium status in fibromyalgia.

Fibromyalgia (FM) is a chronic musculoskeletal pain syndrome of unknown etiology. The serum concentration of selenium (Se) was measured in 68 consecutive patients (nine male, mean age: 47 years; 59 female, mean age 49 years) with FM. The age- and sex-matched control group included 97 female healthy blood donors (mean age 46 years). The method is based on high-performance liquid chromatography (HPLC) involving detection of the fluorescent diaminonaphthalene (DAN) derivate of selenite. There was a statistical significant difference (P < 0.05) in serum Se between control (median 77 microg/l; range: 50-118 microg/l) and patients (median 71 microg/l; range: 39-154 microg/l) groups in the region of Tübingen, Germany.

Adult↗

In vitro evaluation of the long-body On-X bileaflet heart valve.

BACKGROUND AND AIMS OF THE STUDY: In order to optimize the length-to-diameter ratio, a series of circular aluminum rings with flared inlet and varying ring lengths, with internal diameters corresponding to that of 19 mm replacement prosthetic heart valve orifices, were tested in a steady-flow hydraulic system. The study aim was to determine the ring length-to-internal diameter ratio that produces the best hydraulic efficiency (i.e. lowest pressure gradient) within the physiologic flow rate range. METHODS: Each ring was tested at flow rates of 10, 15, 20, 25 and 30 l/min and length-to-diameter ratio effect on hydraulic efficiency determined experimentally. The hydraulic effect was most significant for a ratio of about 0.6, with an increase to 1.2 providing little additional benefit. Thus, a ratio of about 0.6 was considered optimum in terms of hydraulic efficiency and incorporated into the design of the On-X bileaflet mechanical heart valve (BHV) series. An in vitro hydrodynamic study of the smallest (19 mm) and largest (25 mm) clinical On-X aortic valves was performed at two independent laboratories. Standard St. Jude Medical BHVs were used as the study controls. RESULTS: Steady-flow experiments showed that the pressure gradient in the On-X valve was about 50% less than that of the comparable size control. The pulsatile flow study demonstrated a similar pressure gradient advantage. Laser Doppler anemometer velocity profiles taken downstream of the On-X valve at the aortic root showed typical characteristics of bileaflet valves, with three velocity peaks. The peak velocity reached 1.6 m/s for the On-X and 1.75 m/s for the control valve. A recirculating vortex was seen in the sinus cavity during the ejection period. This vortex, found in most aortic valves (including bioprostheses), is believed to provide a beneficial wash-out of the valve region and assist in valve closure. CONCLUSIONS: These two independent studies clearly demonstrated that the elongated valve body and comparably larger flow area helped to improve the valve hydrodynamic performance, which is especially beneficial in the smallest (19 mm) size valve.

Aortic Valve↗

[The dual protective effect of fish oil in preventing coronary diseases].

We studied the effect of incorporation of eicosapentaenoic and docosahexaenoic acid into the normal Western diet in nine human volunteers for 6 weeks. They received 1.5 g per day of omega 3-polyunsaturated fatty acids (W3-PUFA) for 3 weeks followed by 3 weeks with supplementation of 3.0 g per day. A control period of 3 weeks preceded PUFA supplementation. A significant effect on lipids was found in the total triglycerides and VLDL-triglyceride fractions (p less than 0.025). The ratio VLDL-triglyceride over HDL-cholesterol was also significantly diminished after 6 weeks of treatment (0.86 +/- 0.15 vs 1.01 +/- 0.19, p less than 0.02). Prolongation of the bleeding time was clearly demonstrated after 6 weeks of supplementation (10.6 +/- 1.3 min vs 6.2 +/- 0.6 min). Platelet aggregation stimulated by either ADP or collagen was significantly diminished after W3-PUFA supplementation (p less than 0.025 and p less than 0.005 after ADP and collagen respectively). The lag time of platelet aggregation was significantly prolonged (94 +/- 12 vs 56 +/- 2 sec, p less than 0.005) and the maximum speed reaction of the primary phase of the reaction was significantly diminished (1.3 +/- 0.2 vs 1.6 +/- 0.2 mm/sec, p less than 0.02). In conclusion, in the light of this study W3-PUFA supplementation leads to two different benefits in cardiovascular prevention. First, a significant diminution of total plasma triglyceride has been shown and, second, prolongation of the bleeding time and diminution of the platelet aggregation have been demonstrated.

Adult↗