Search PubMed⌕ Search

Biomedical subjects

P R Ershler

Publications and source records attributed to P R Ershler.

At least 19 recordsLinked to original sources

Noninvasive electrocardiogram imaging of substrate and intramural ventricular tachycardia in infarcted hearts.

OBJECTIVES: The goal of this study was to experimentally evaluate a novel noninvasive electrocardiographic imaging modality during intramural reentrant ventricular tachycardia (VT). BACKGROUND: Myocardial infarction and subsequent remodeling produce abnormal electrophysiologic substrates capable of initiating and maintaining reentrant arrhythmias. Existing noninvasive electrocardiographic methods cannot characterize abnormal electrophysiologic substrates in the heart or the details of associated arrhythmias. A noninvasive method with such capabilities is needed to identify patients at risk of arrhythmias and to guide and evaluate therapy. METHODS: A dog heart with a four-day-old infarction was suspended in a human shaped torso-tank. Measured body surface potentials were used to noninvasively compute epicardial potentials, electrograms and isochrones. Accuracy of reconstruction was evaluated by direct comparison to measured data. Reconstructions were performed during right atrial pacing and nine cycles of VT. RESULTS: Noninvasively reconstructed potential maps, electrograms and isochrones identified: 1) the location of electrophysiologically abnormal infarct substrate; 2) the epicardial activation sequences during the VTs; 3) the locations of epicardial breakthrough sites; and 4) electrophysiologic evidence for activation of the Purkinje system and septum during the reentrant beats. CONCLUSIONS: Electrocardiographic imaging can noninvasively reconstruct electrophysiologic information on the epicardium during VT with intramural reentry, provide information about the location of the intramural components of reentry and image abnormal electrophysiologic substrates associated with infarction.

Animals↗

Estimates of repolarization dispersion from electrocardiographic measurements.

BACKGROUND: Repolarization dispersion (Rd) is frequently mentioned as a predictor of cardiac abnormalities. We present a new measure of Rd based on the root-mean-square (RMS) curve of an ECG lead set and compare its performance with that of the commonly used QT dispersion (QTd) measure with the use of recovery times measured from directly recorded canine electrograms. METHODS AND RESULTS: Using isolated, perfused canine hearts suspended in a torso-shaped electrolytic tank, we simultaneously recorded electrograms from 64 epicardial sites and ECGs from 192 "body surface" sites. RMS curves were derived from 4 lead sets: epicardial, body surface, precordial, and a 6-lead optimal set. Repolarization was altered by changing cycle length, temperature, and activation sequence. Rd, calculated directly from recovery times of the 64 epicardial potentials, was then compared with the width of the T wave of the RMS curve and with QTd for each of these 4 lead sets. The correlation between T-wave width and Rd for each lead set, respectively, was epicardium, 0.91; body surface, 0.84; precordial, 0.72; and optimal leads, 0.81. The correlation between QTd and Rd for each lead set was epicardium, 0.46; body surface, 0.47; precordial, 0.17; and optimal leads, 0.11. CONCLUSIONS: RMS curve analysis provides an accurate method of estimating Rd from the body surface. In contrast, QTd analysis provides a poor estimate of Rd.

Animals↗

Estimates of repolarization and its dispersion from electrocardiographic measurements: direct epicardial assessment in the canine heart.

This study investigates a technique to estimate dispersion based on the root mean square (RMS) signal of multiple electrocardiographic leads. Activation and recovery times were measured from 64 sites on the epicardium of canine hearts using acute in situ or Langendorff perfused isolated heart preparations. Repolarization and its dispersion were altered by varying cycle length, myocardial temperature, or ventricular pacing site. Mean and dispersion of activation and recovery times, and activation-recovery interval (ARI) were calculated for each beat. The waveform was then calculated from all leads. Estimates of mean and dispersion of activation and recovery times and mean ARI were derived using only inflection points from the RMS waveform. QT intervals were also measured and QT dispersion was determined. Estimates determined from the RMS waveform provided accurate estimates of repolarization and were, in particular, a better measure of repolarization dispersion than QT dispersion.

Animals↗

Effects of heart position on the body-surface electrocardiogram.

Previous studies have examined the influence of body position, respiration, and habitus on body surface potentials. However, the authors could only estimate the sources of the effects they documented. Among the proposed origin of changes in body surface potentials from those studies were the position of the heart, alterations in autonomic tone, differences in ventricular blood volume, and variations in torso resistivity. The goal of this study was to investigate specifically the role of geometric factors in altering body surface potentials and the electrocardiogram. For this, we used experiments with an isolated, perfused dog heart suspended in a realistically shaped electrolytic torso tank. The experimental preparation allowed us to measure epicardial and tank surface potentials simultaneously, and then reconstruct the geometry of both surfaces. Our results mimicked some of the features described by previous investigators. However, our results also showed differences that included considerably larger changes in the peak QRS and T-wave amplitudes with heart movement than those reported in human studies. We detected smaller values of root-mean-squared variability from heart movements than those reported in a human study comparing body surface potentials during change in inspiration and body position. There was better agreement with relative variability, which in these studies ranged from 0.11 to 0.42, agreeing well with an estimate from human studies of 0.40. Our results suggest that the isolated heart/torso tank preparation is a valuable tool for investigating the effects of geometric variation. Furthermore, the geometric position of the heart appears to be a large source of variation in body surface potentials. The size of these variations easily exceeded thresholds used to distinguish pathologic conditions and thus such variations could have important implications on the interpretation of the standard electrocardiogram.

Action Potentials↗

Generation of intracellular pH gradients in single cardiac myocytes with a microperfusion system.

This study describes the use of a microperfusion system to create rapid, large regional changes in intracellular pH (pH(i)) within single ventricular myocytes. The spatial distribution of pH(i) in single myocytes was measured with seminaphthorhodafluor-1 fluorescence using confocal imaging. Changes in pH(i) were induced by local external application of NH(4)Cl, CO(2), or sodium propionate. Local application was achieved by simultaneously directing two parallel square microstreams, each 275 microm wide, over a single myocyte oriented perpendicular to the direction of flow. One stream contained the control solution, and the other contained a weak acid or base. End-to-end, stable pH(i) gradients as large as 1 pH unit were readily created with this technique. This result indicates that pH within a single cardiac cell may not always be spatially uniform, particularly when weak acid or base gradients are present, which can occur, for example, in regional myocardial ischemia. The microperfusion method should be useful for studying the effects of localized acidosis on myocyte function, estimating intracellular ion diffusion rates, and, possibly, inducing regional changes in other important intracellular ions.

Acidosis↗

Properties of Ca2+ sparks evoked by action potentials in mouse ventricular myocytes.

1. Calcium sparks were examined in enzymatically dissociated mouse cardiac ventricular cells using the calcium indicator fluo-3 and confocal microscopy. The properties of the mouse cardiac calcium spark are generally similar to those reported for other species. 2. Examination of the temporal relationship between the action potential and the time course of calcium spark production showed that calcium sparks are more likely to occur during the initial repolarization phase of the action potential. The latency of their occurrence varied by less than 1.4 ms (s.d.) and this low variability may be explained by the interaction of the gating of L-type calcium channels with the changes in driving force for calcium entry during the action potential. 3. When fixed sites within the cell are examined, calcium sparks have relatively constant amplitude but the amplitude of the sparks was variable among sites. The low variability of the amplitude of the calcium sparks suggests that more than one sarcoplasmic reticulum (SR) release channel must be involved in their genesis. Noise analysis (with the assumption of independent gating) suggests that > 18 SR calcium release channels may be involved in the generation of the calcium spark. At a fixed site, the response is close to 'all-or-none' behaviour which suggests that calcium sparks are indeed elementary events underlying cardiac excitation-contraction coupling. 4. A method for selecting spark sites for signal averaging is presented which allows the time course of the spark to be examined with high temporal and spatial resolution. Using this method we show the development of the calcium spark at high signal-to-noise levels.

Action Potentials↗

Noninvasive indices of repolarization and its dispersion.

In experimental studies using Langendorff perfused, isolated canine hearts immersed in a torso-shaped electrolytic tank we studied repolarization and its dispersion using direct epicardial measurements and newly derived, noninvasive body surface indices. Activation recovery intervals (ARIs) measured from 64 epicardial sites based on differences between activation times (ATs) and recovery times (RTs) provided direct measures of repolarization. The indirect, torso surface indices were derived from inflections of the root-mean-square (RMS) voltage of the torso tank surface electrocardiograms recorded simultaneously with the epicardial data. For cycle lengths ranging from 300 to 900 ms, and electrolyte temperatures ranging from 32 degrees C to 40 degrees C we calculated mean, variance, and range of ATs, RTs, and ARIs from the epicardium. From epicardial and torso surface RMS waveforms, we used times of R and T peaks and their differences to estimate mean ATs, RTs, and ARIs, respectively. The RMS T wave width as determined from the second derivative inflections on either side of the T peak served as an estimate of the dispersion of RTs. In parallel studies, we showed that the direct measures of repolarization and its dispersion were reflected in RMS waveforms generated from the epicardial electrograms themselves. In this study, we confirm that the torso and epicardial RMS waveforms reflect comparable information for estimating repolarization and its dispersion. Furthermore, the derived measures provide a method to assess mean ARIs and dispersion of RTs on a beat-to-beat basis and during abnormal (ectopic ventricular) activation sequences.

Animals↗

Mechanisms of the spatial distribution of QT intervals on the epicardial and body surfaces.

INTRODUCTION: The role of QT dispersion as a predictor of arrhythmia vulnerability has not been consistently confirmed in the literature. Therefore, it is important to identify the electrophysiologic mechanisms that affect QT duration and distribution. We compared the spatial distributions of QT intervals (QTI) with potential distributions on cardiac and body surfaces and with recovery times on the cardiac surface. We hypothesized that the measure of QTI is affected by the presence of the zero potential line in the potential distribution, as well as the sequence of recovery. We also investigated use of the STT area as a possible indicator of recovery times on the cardiac surface. METHODS AND RESULTS: High-resolution spatial distributions of QTI and potentials were determined on the body surface of human subjects and on the surface of a torso-shaped tank containing an isolated canine heart. Additionally, spatial distributions of QTI, recovery times, and STT areas were determined on the surface of exposed canine hearts. Unipolar electrograms were recorded during atrial and ventricular pacing for normal hearts and cases of myocardial infarction. Regions of shortest QTI always coincided with the location of the zero potential line on the cardiac and body surfaces. On the cardiac surface, in regions away from the zero line, similarities were observed between the patterns of QTI and the sequence of recovery. STT areas and recovery times were highly correlated on the cardiac surface. CONCLUSION: QTI is not a robust index of local recovery time on the cardiac surface. QTI distributions were affected by the position of the zero potential line, which is unrelated to local recovery times. However, similarities in the patterns of QTI and recovery times in some regions may help explain the frequently reported predictive value of QT dispersion. Preliminary results indicate STT area may be a better index of recovery time and recovery time dispersion on the epicardium than QTI.

Animals↗

Electrocardiographic imaging: Noninvasive characterization of intramural myocardial activation from inverse-reconstructed epicardial potentials and electrograms.

BACKGROUND: A recent study demonstrated the ability of electrocardiographic imaging (ECGI) to reconstruct, noninvasively, epicardial potentials, electrograms, and activation sequences (isochrones) generated by epicardial activation. The current study expands the earlier work to the three-dimensional myocardium and investigates the ability of ECGI to characterize intramural myocardial activation noninvasively and to relate it to the underlying fiber structure of the myocardium. This objective is motivated by the fact that cardiac excitation and arrhythmogenesis involve the three-dimensional ventricular wall and its anisotropic structure. METHODS AND RESULTS: Intramural activation was initiated by pacing a dog heart in a human torso tank. Body surface potentials (384 electrodes) were used to compute epicardial potentials noninvasively. Accuracy of reconstructed epicardial potentials was evaluated by direct comparison to measured ones (134 electrodes). Protocols included pacing from five intramural depths. Epicardial potentials showed characteristic patterns (1) early in activation, central negative region with two flanking maxima aligned with the orientation of fibers at the depth of pacing; (2) counterclockwise rotation of positive potentials with time for epicardial pacing, clockwise rotation for subendocardial pacing, and dual rotation for midmyocardial pacing; and (3) central positive region for endocardial pacing. Noninvasively reconstructed potentials closely approximated these patterns. Reconstructed epicardial electrograms and epicardial breakthrough times closely resembled measured ones, demonstrating progressively later epicardial activation with deeper pacing. CONCLUSIONS: ECGI can noninvasively estimate the depth of intramyocardial electrophysiological events and provides information on the spread of excitation in the three-dimensional anisotropic myocardium on a beat-by-beat basis.

Animals↗

QT interval dispersion: dispersion of ventricular repolarization or dispersion of QT interval?

The QT interval (QTI) has long been useful as a clinical index of the duration of ventricular repolarization, particularly as a marker of prolonged repolarization and its well-established association with arrhythmogenic cardiac states. Likewise, inhomogeneity (dispersion) of repolarization has been linked definitively to increased susceptibility to reentrant arrhythmias. Recent studies have reported the use of QTI dispersion as a meaningful clinical index to identify patients at risk, but the interpretation of the measurement has been controversial. A Langendorff-perfused, isolated canine heart suspended in a torso-shaped, electrolytic tank filled with NaCl-sucrose solution was used to investigate the relationship between body surface QTIs and ventricular repolarization measured directly from the cardiac surface by using activation-recovery intervals, which have been documented to reflect the duration of local action potentials as well as local refractory periods. The data showed poor correlation between cardiac surface activation-recovery intervals and QTIs, as well as the insensitivity of QTIs to regional repolarization shortening in the presence of prolonged repolarization elsewhere. Furthermore, the data confirmed that torso tank QTI dispersion does not reflect directly the full range of measured ventricular repolarization inhomogeneity. It is concluded that body surface QTI dispersion is not a reliable index of repolarization dispersion.

Action Potentials↗

Useful lessons from body surface mapping.

Useful Lessons from Body Surface Mapping. Body surface potential maps (BSMs) depict the time varying distribution of cardiac potentials on the entire surface of the torso. Hundreds of studies have shown that BSMs contain more diagnostic and prognostic information than can be elicited from the 12-lead ECG. Despite these advantages, body surface mapping has not become a routinely used clinical method. One reason is that visual examination and sophisticated analysis of BSMs do not permit inferring the sequence of excitation and repolarization in the heart with a sufficient degree of certainty and detail. These limitations can be partially overcome by implementing inverse procedures that reconstruct epicardial potentials, isochrones, and ECGs from body surface measurements. Furthermore, ongoing experimental work and simulation studies show that a great deal of information about intramural events can be elicited from measured or reconstructed epicardial potential distributions. Interpreting epicardial data in terms of deep activity requires extensive knowledge of the architecture of myocardial fibers, their anisotropic properties, and the role of rotational anisotropy in affecting propagation and the associated potential fields.

Body Surface Potential Mapping↗

High-density epicardial mapping during current injection and ventricular activation in rat hearts.

The purpose of this study is to report new methods for manufacturing precision electrode arrays for recording high-resolution potential distributions from epicardial surfaces of small-animal hearts. Electrode arrays of 64 leads (8 x 8) and 121 leads (11 x 11) were constructed with a tulle substrate to which insulated, fine silver wires (60-micrometer diameter) were attached by knots at mesh node intervals of 540 x 720 micrometers. Insulation was removed at the tips of the knots. Potential distributions and waveforms were recorded from saline solutions and rat heart epicardium during ventricular paced beats and during passive current injection in the diastolic interval. Electrical responses obtained from rat epicardium compared favorably with those observed in studies of larger-animal hearts, which used arrays having greater electrode spacing, and revealed the effects of myocardial anisotropy. Epicardial potentials measured early after stimulation in the region surrounding the pacing site were interpreted in terms of potentials generated by an equivalent quadrupolar source. We conclude that electrode arrays for epicardial mapping of small hearts can be constructed with sufficient ease and precision to allow detailed study of fiber structure and electrophysiology in these hearts in normal and pathological conditions.

Action Potentials↗

Noninvasive electrocardiographic imaging: reconstruction of epicardial potentials, electrograms, and isochrones and localization of single and multiple electrocardiac events.

BACKGROUND: The goal of noninvasive electrocardiographic imaging (ECGI) is to determine electric activity of the heart by reconstructing maps of epicardial potentials, excitation times (isochrones), and electrograms from data measured on the body surface. METHODS AND RESULTS: Local electrocardiac events were initiated by pacing a dog heart in a human torso-shaped tank. Body surface potential measurements (384 electrodes) were used to compute epicardial potentials noninvasively. The accuracy of reconstructed epicardial potentials was evaluated by direct comparison to measured ones (134 electrodes). Protocols included pacing from single sites and simultaneously from two sites with various intersite distances. Body surface potentials showed a single minimum for both single- and double-site pacing (intersite distances of 52, 35, and 17 mm). Noninvasively reconstructed epicardial electrograms, potentials, and isochrones closely approximated the measured ones. Single pacing sites were reconstructed to within < or = 10 mm of their measured positions. Dual sites were located accurately and resolved for the above intersite distances. Regions of sparse and crowded isochrones, indicating spatial nonuniformities of epicardial activation spread, were also reconstructed. CONCLUSIONS: The study demonstrates that ECGI can reconstruct epicardial potentials, electrograms, and isochrones over the entire epicardial surface during the cardiac cycle. It can provide detailed information on local activation of the heart noninvasively. Its uses could include localization of cardiac electric events (eg, ectopic foci), characterization of nonuniformities of conduction, characterization of repolarization properties (eg, dispersion), and mapping of dynamically changing arrhythmias (eg, polymorphic VT) on a beat-by-beat basis.

Animals↗

Noncontact endocardial mapping: reconstruction of electrograms and isochrones from intracavitary probe potentials.

INTRODUCTION: Mapping endocardial activation and repolarization processes is critical to the study of arrhythmias and selection of therapeutic procedures. Previously, we developed methodology for reconstructing endocardial potentials from potentials measured with a noncontact, intracavitary probe. This study further develops and evaluates the ability of the approach to provide detailed information on the spatiotemporal characteristics of the activation process. Specifically, we reconstructed endocardial electrograms and isochrones throughout the activation process over the entire endocardium during a single beat. METHODS AND RESULTS: Cavity potentials were measured with a 65-electrode probe placed inside an isolated canine left ventricle. Endocardial potentials were measured simultaneously using 52 electrodes. Potentials were acquired during subendocardial pacing from different locations. Computed electrograms at various sites closely resemble the measured electrograms (correlation coefficient > 0.9 at 60% of the electrodes). Computed isochrones locate subendocardial pacing sites with 10-mm accuracy. Two pacing sites, 17 mm apart, were resolved. Critical regions, such as areas of isochrone crowding, were accurately reconstructed. CONCLUSIONS: Results indicate the applicability of the approach to mapping the cardiac excitation process on a beat-by-beat basis without occluding the ventricle. The ability of locating electrical events (e.g., single or multiple initiation sites) is demonstrated. Importantly, the method is shown to be capable of reconstructing electrograms over the entire endocardium and determining nonuniformities of activation spread (e.g., areas of slow conduction). These capabilities are important to clinical application in the electrophysiology laboratory and experimental studies of arrhythmias in the intact animal.

Animals↗

Anatomical architecture and electrical activity of the heart.

In most early studies of cardiac electrophysiology, the correlation between propagation of excitation and the architecture of cardiac fibers was not addressed. More recently, it has become apparent that the spread of excitation, the sequence of recovery, the associated time-varying potential distributions and the intra- and extracardiac electrocardiograms are strongly affected by the complex orientation of myocardial fibers. This article is a review of older and very recent, partly unpublished, mathematical simulations and experimental findings that document the relationships between cardiac electrophysiology and fiber structure. Important anatomical factors that affect propagation and recovery are: the elongated shape of myocardial fibers which is the basis for electrical anisotropy; the epi-endocardial rotation of fiber direction in the ventricular walls; the epi-endocardial obliqueness of the fibers ("imbrication angle"), and the conduction system. Due to the complex architecture of the fibers, many different pathways are available to an excitation wavefront as it spreads from a pacing site: the straight line; the multiple, bent pathways resulting from the epi-endocardial rotation of fiber direction; the coiling intramural pathways associated with the "imbrication" angles (Streeter) and the pathways involving the Purkinje network. Only in a few cases is the straight line the fastest pathway. The shape of an excitation wavefront at a given time instant results from the competition between all possible pathways. To compute the potential distributions and ECG waveforms generated by a spreading excitation wave we must know the successive shapes and positions of the wavefront, the architecture of the fibers through which it propagates and the spatial distribution of their anisotropic electrical properties.

Electrophysiology↗

Measuring spatial waves of repolarization in canine ventricles using high-resolution epicardial mapping.

The importance of the role of ventricular repolarization in arrhythmogenesis and defibrillation prompted the exploration of new methods for observing and measuring repolarization. Specifically, the authors' goal was to establish independent procedures for assessing activation-recovery intervals. Canine epicardial electrograms from high-resolution arrays (2-mm spacing, 25 x 21 electrodes) were recorded-during pacing from a variety of single or simultaneously paced epicardial locations in canine hearts. For each activation sequence, the activation and repolarization times were measured using timing of intrinsic QRS and T wave deflections (activation-recovery interval method) and timing of the peak magnitude of spatial derivatives (gradient method). Both methods should, theoretically, provide estimates of local activation and repolarization times, which reflect timing of local action potential upstrokes and downstrokes. Scattergrams comparing activation and recovery times for the two methods showed high correlation, slopes close to 1.0, and intercepts near the origin. For most activation sequences, observation of the potential and gradient distributions as dynamic, three-dimensional perspective displays, revealed a well-defined, rapidly propagating repolarization wave, superimposed on a slowly varying, high-amplitude distribution occurring during the T wave. These data suggest that repolarization times measured using temporal or spatial derivatives are consistent with theoretical predictions and reflect timing of local action potential downstrokes. They also suggest potential utility of combining spatial and temporal approaches for improving reliability in the measurements.

Action Potentials↗