Search PubMed⌕ Search

Biomedical subjects

P Peyton

Publications and source records attributed to P Peyton.

12 recordsLinked to original sources

Non-invasive metabolic monitoring of patients under anaesthesia by continuous indirect calorimetry--an in vivo trial of a new method.

BACKGROUND: Oxygen uptake is an important form of metabolic monitoring for patients under anaesthesia. In critically ill patients oxygen uptake has been shown to provide valuable clinical information in directed therapy and acts as a useful monitor of cardiovascular dysfunction. A new method of continuous real time monitoring of metabolic gas exchange was tested in patients during anaesthesia. METHODS: Using a standard anaesthetic machine with attached semi-closed circle absorber system, oxygen uptake was measured continuously throughout surgery in 30 patients undergoing cardiopulmonary bypass surgery and compared with paired measurements made with the reverse Fick method. The method is an indirect calorimetry technique which uses fresh gas rotameters for control, regulation and measurement of the gas flows into the system, with continuous sampling of mixed exhaust gas. RESULTS: When compared with the reverse Fick method the oxygen uptake showed a mean difference (and sd) of 20.7 ml min(-1) or 12.1% (25.3 ml min(-1)) pre-bypass and 13.9 ml min(-1) or 8.1% (27.0 ml min(-1)) post-bypass. This bias is consistent with previous studies comparing oxygen uptake measured at the mouth against oxygen uptake by reverse Fick, which have shown a difference of approximately 10-15% accounted for by the consumption of oxygen by lung tissue. CONCLUSIONS: As the method allows continuous measurement of gas exchange and can be adapted to a modern anaesthetic workstation it is an attractive method for use in clinical setting.

Aged↗

Perioperative pulse contour cardiac output analysis in a patient with severe cardiac dysfunction.

We describe a patient with severe left ventricular dysfunction simultaneously monitored with pulse contour cardiac output (PiCCO) analysis, a continuous cardiac output pulmonary artery catheter (continuous COPAC) and intraoperative transoesophageal echocardiography (TOE). There was good agreement between cardiac output (CO) measurements obtained by the three techniques prior to cardiopulmonary bypass (CPB). Agreement of CO measurements following CPB was initially pool; but improved following recalibration of PiCCO. PiCCO-derived global end-diastolic volume index (GEDVI) and cardiac function index (CFI), were assessed as markers of left ventricular preload and myocardial contractility, respectively. GEDVI correlated well with CO in the postoperative period. CFI increased more than two-fold following coronary revascularization and milrinone administration, and there was also a temporal relationship between the CFI and the dose of milrinone in the first 24 hours of treatment. Global end-diastolic volume and cardiac function index may be useful additional measures of left ventricular preload and myocardial contractility in patients with severe left ventricular dysfunction.

Cardiac Output↗

An introductory guide to survey research in anaesthesia.

Surveys allow convenient and inexpensive research. Surveys include mail-out questionnaires, email questionnaires, telephone interviews, and personal interviews. Despite a widespread perception that surveys are easy to conduct, good surveys need rigorous design, implementation and analysis. This requires substantial planning, time and effort. The most important step in designing a survey is to clearly define the question(s) the survey aims to answer The target population, measured variables and types of associations being investigated should be specific and unambiguous. Investigators should concentrate on what they 'need to know' rather than what would be 'nice to know'. During development surveys should be piloted to identify problems. The main goal when implementing a survey is to maximize the response rate to avoid misleading results. Evidence-based strategies, including brief personalized surveys with stamped return envelopes, can be used to maximize the response rate. A poorly conducted survey can lead to misleading or invalid conclusions and may undermine participation in subsequent surveys by the target population.

Anesthesiology↗

Accuracy of the Foldes-Biro equation for measurement of oxygen uptake during anaesthesia: a laboratory simulation.

Laboratory benchtop testing was conducted of the Biro method for measurement of oxygen uptake from an anaesthetic breathing system by patients during low flow anaesthesia. A high precision flow and gas concentration measurement system was employed in conjunction with a physical gas exchange simulation model to test the theoretical basis of the method under controlled conditions. Simulated oxygen uptake values between 200 and 350 ml x min(-1) were modelled. The Biro-derived measurement of simulated O(2) uptake significantly underestimated the target value (mean difference -88.5 ml x min(-1), or -31.7%). The bias was directly proportional to the simulated O(2) uptake. The Biro method has a systematic bias that cannot be explained by random measurement imprecision.

Anesthesia, Inhalation↗

Design of the multicenter Australian study of epidural anesthesia and analgesia in major surgery: the MASTER trial.

The Multicenter Australian Study of Epidural Anesthesia and Analgesia in Major Surgery (The MASTER Trial) was designed to evaluate the possible benefit of epidural block in improving outcome in high-risk patients. The trial began in 1995 and is scheduled to reach the planned sample size of 900 during 2001. This paper describes the trial design and presents data comparing 455 patients randomized in 21 institutions in Australia, Hong Kong, and Malaysia, with 237 patients from the same hospitals who were eligible but not randomized. Nine categories of high-risk patients were defined as entry criteria for the trial. Protocols for ethical review, informed consent, randomization, clinical anesthesia and analgesia, and perioperative management were determined following extensive consultation with anesthesiologists throughout Australia. Clinical and research information was collected in participating hospitals by research staff who may not have been blind to allocation. Decisions about the presence or absence of endpoints were made primarily by a computer algorithm, supplemented by blinded clinical experts. Without unblinding the trial, comparison of eligibility criteria and incidence of endpoints between randomized and nonrandomized patients showed only small differences. We conclude that there is no strong evidence of important demographic or clinical differences between randomized and nonrandomized patients eligible for the MASTER Trial. Thus, the trial results are likely to be broadly generalizable.

Aged↗

Supplementary oxygenation with the laryngeal mask airway: a comparison of four devices.

The provision of supplementary oxygen via the laryngeal mask airway used in the recovery room is important for patient safety. Several devices have been described for this purpose, but these studies have not included an accurate measurement of the most clinically important variable, the end-tidal oxygen concentration. We constructed an artificial model of spontaneous ventilation to compare the efficacy and safety of four devices; a circuit filter, a Hudson mask, the 'T-bag' device and a T-piece. We combined the use of oximetry with a pneumotachograph to provide a continuous picture of the oxygen delivery characteristics of the devices at flow rates of 2, 4 and 8 l.min-1. The performances of the T-bag and the T-piece were superior to those of the filter and Hudson mask, with end-tidal oxygen concentrations of 46.1%, 45.8% and 35.4%, 34.8%, respectively, at 8 l.min-1. Single point assessments of oxygen delivery, such as peak inspired oxygen concentration, may overestimate the efficacy of test devices.

Anesthesia Recovery Period↗