[Continuous bipolar electrostimulation of the heart].

The analysis of the data available in the literature has shown that bipolar pacing systems are promising. The paper indicates that the first samples of a Soviet bipolar electrode have been made and tested in the laboratory setting. It also raises whether it is necessary to design bipolar pacemakers.

Electrocardiography↗

[Medical and vocational rehabilitation of patients with implanted pacemakers].

Medical and occupational rehabilitation following pacemaker implantation is discussed with special reference to objective quality of medical and technical data, on which occupational recommendations are to be based. A comprehensive analysis of whether an individual with an implanted pacemaker can drive a car is presented.

Activities of Daily Living↗

[Structure of the tissue adjacent to the electrode in the case of an extremely low threshold of cardial electrostimulation].

The authors present the data of the histological structure of the dog heart tissue adjacent to the electrode tip following a ten-month period of electrical stimulation by means of an implanted graphited porous endocardial electrode and a pacemaker of the alternating polarity. The reason for performing such an histological investigation was an extremely low chronic threshold of heart electrostimulation, amounting to 0.35 V with the stimulus duration 1 ms. The structural features of the tissues as viewed by the authors, consist in (1) the thinning of the fibrous capsule of the electrode tip; (2) the presence of a zone adjacent to the electrode, with this zone being rich in the liquid component of the intercellular substance; (3) the formation of a conspicuous radix of the fibrous capsule, penetrating into the depth of the myocardium.

Animals↗

[Electrostimulation of the interatrial septum].

The first clinical experience of the successful application of electrostimulation of the atrial septum is described. Sickle-shaped electrodes were used for this purpose. Electrostimulation of the atrial septum was medically indicated in all cases. In 2 cases the electrode was fixed to the atrial septum after open-heart surgery and in 3 cases it was done because of an excessively high threshold of cardiac electrostimulation. Sickle-shaped electrodes are shown to be the most optimal for continuous electrostimulation of the atrial septum.

Cardiac Pacing, Artificial↗