Search PubMed⌕ Search

Biomedical subjects

P N Lelie

Publications and source records attributed to P N Lelie.

At least 19 recordsLinked to original sources

Concurrence of hepatitis B surface antibodies and surface antigen: implications for postvaccination control of health care workers.

Among 1081 persons testing positive for hepatitis B surface antigen, 106 (10%) tested positive for antibodies to surface antigen (anti-HBs) in the same blood sample. Thirty of these persons were studied in detail: seven tested positive for hepatitis B e-antigen, nine were apparently healthy blood donors, and in 14 chronic infection could be demonstrated in follow-up samples. Frozen samples of 14 persons were available for additional quantitative anti-HBs testing using another anti-HBs assay: three showed no anti-HBs reactivity, seven showed borderline anti-HBs levels (1-5 IU/L), and anti-HBs titres ranged from 23 to 66 IU/L in four HBsAg-positive persons, including an apparently healthy blood donor. Thus, after hepatitis B vaccination of medical personnel, presence of anti-HBs may erroneously suggest immunity, while in fact chronic infection with hepatitis B virus is present.

Adolescent↗

Validation of the NucliSens Extractor in combination with the hepatitis C virus Cobas Amplicor 2.0 assay in four laboratories in the Netherlands utilizing nucleic acid amplification technology for blood screening.

BACKGROUND AND OBJECTIVES: Since July 1 1999, four laboratories in the Netherlands have been routinely screening plasma minipools for the release of labile blood components utilizing hepatitis C virus nucleic acid amplification technology (HCV NAT). This report describes the performance evaluation of the HCV NAT method and the quality control results obtained during 6 months of routine screening. MATERIALS AND METHODS: Plasma minipools of 48 donations were prepared on a Tecan Genesis robot. HCV RNA was isolated from 2 ml of plasma by using the NucliSens Extractor and amplified and detected with the Cobas HCV Amplicor 2.0 test system. For validation of the test system the laboratories used viral quality control (VQC) reagents of CLB. RESULTS: Initial robustness experiments demonstrated consistent detection of PeliSpy HCV RNA samples of 140 genome equivalents/ml (geq/ml) in each station of the installed Nuclisens Extractors. Further 'stress' tests with a highly viraemic sample of approximately 5 x 10(6) geq/ml did not contaminate negative samples processed on all Extractor stations in subsequent runs. In the validation period prior to July 1999, 1021 pools were tested with the following performance characteristics: 0.1%, initially false reactive; 0.89%, failure of internal control detection; 0.97%, no eluate generated by the Extractor; and 100% reactivity of the PeliSpy 140 geq/ml control in 176 Extractor runs and a 98% reactivity rate of the PeliSpy 38 geq/ml control in 102 test runs. By testing the PeliCheck HCV RNA genotype 1 dilution panels 49 times, an overall 95% detection limit of 30 geq/ml ( approximately 8 IU/ml) and a 50% detection limit of 5 geq/ml was found by the four laboratories. In the first 6 months of routine screening, the minimum requirement for invalid results (2%) was exceeded with some batches of silica and NucliSens Extractor cartridges. From November 1999 to February 2000, the manufacturer (Organon Teknika) improved the protocol for silica absorption of the Nuclisens Extractor -- the cartridge design as well as the software of the Extractor. During the next 6 months of observation in 2000, the percentages of false initial reactives and invalids were 0.05% and 1.4%, respectively, in 8962 pools tested. Of these invalid results, 0.74% and 0.66% were caused by Extractor failure and negative internal control signals, respectively. The PeliSpy HCV RNA 'stop or go' run control of 140 geq/ml was 100% reactive, but invalid in 16/1375 (1.2%) of cases. The PeliSpy run control of 38 geq/ml for monitoring sensitivity of reagent batches was reactive in 95% of 123 samples tested. CONCLUSIONS: Each of the four HCV NAT laboratories in the Netherlands have achieved similar detection limits that are well below the sensitivity requirements of the regulatory bodies. After improvement of the NucliSens Extractor procedure, the robustness of the test system has proved to be acceptable for routine screening and timely release of all labile blood components.

Equipment Failure↗

Sustained virological response in chronic hepatitis C patients after a 6- and a 36-month interferon-alpha2b treatment schedule: a multicenter, randomized, controlled study.

BACKGROUND: In patients with chronic hepatitis C (HCV) Interferon-alpha (IFN) treatment for 12-18 months is more effective than 6 months in inducing a sustained virological response. METHODS: In a multicenter, randomized, controlled trial, 88 patients with chronic HCV were enrolled (47 treated with IFN-alpha2b and 41 constituted an untreated control group). Treatment consisted of 5 million units (MU) IFN thrice a week (tiw) for 8 weeks and subsequently 2.5 MU IFN tiw for 16 weeks ('standard treatment'). After week 24 ('long-term treatment'), in virological non-responders treatment was continued using 5 MU IFN tiw for up to week 156, whereas in virological responders IFN was discontinued. In case of a virological relapse, treatment with 5 MU IFN tiw was restarted and continued up to week 156. RESULTS: Sustained virological response rate was 6/47 (13%) after standard treatment and increased to 19/47 (40%) after long-term treatment (McNemar paired test; P = 0.002). Of the 18 patients with a breakthrough or relapse during or after standard treatment, 14 (78%) became sustained virological responders upon long-term treatment. Of the 4 patients who did not have a sustained virological response after long-term treatment, 3 did not receive complete treatment due to side effects and/or non-compliance. In patients who failed to respond to standard treatment, no virological response was observed during long-term treatment. In the control group, no spontaneous clearance of HCV was observed. CONCLUSIONS: Long-term IFN (re)treatment enhanced the virological sustained response rate significantly and was particularly effective in patients with a breakthrough or relapse following standard treatment.

Adult↗

European multi-centre validation study of NucliSens Extractor in combination with HCV Amplicor 2.0 assay for HCV-NAT screening of plasma pools.

The NucliSens Extractor in combination with the 2.0 version of the Roche Cobas HCV Amplicor test has been validated by five European blood screening laboratories in a multi-centre study. For testing the performance characteristics of this HCV-NAT method, the European Pharmacopoeia validation guidelines were followed. The CLB VQC reference reagents were used for testing robustness and sensitivity. After a technical improvement in the extraction stations, the NucliSens Extractor appeared to be contamination-free as was proved by testing negative controls alternating with samples containing a high HCV-RNA concentration. The Pelicheck HCV-RNA genotype 1 dilution panel was tested 74 times in the five laboratories and an overall 95% detection limit of 80 genome equivalents (geq)/ml was found. In one laboratory the Pelicheck panel was tested in 25 runs and here a 95% detection limit of 32 geq/ml was achieved. In this laboratory the Pelispy HCV-RNA run control samples of 140 geq/ml were consistently picked up in all extractor stations. In addition the laboratories have tested a WHO HCV-RNA genotype 1 standard dilution series 39 times and a Pelicheck HCV-RNA genotype 3 reference panel in 32 test runs. The limiting dilution analysis enabled us to compare the detection efficiency of the NucliSens-Amplicor method for the genoype 1 and genotype 3 isolates and to calibrate the reference reagents against each other. The combined Nuclisens-Amplicor method was found to detect the genotype 3 isolate in the Pelicheck HCV-RNA panels with 2-3 fold lower efficiency than the genotype 1 standard (assuming that the historical calibration of the genotype 3 against the genotype 1 standard is correct). In this study of a single method 1 IU of the WHO HCV-RNA standard was found to be equivalent to 5.1 geq of the VQC HCV-RNA standard (95% confidence intervals 3.1-9.1 geq). To avoid confusion with the use of the CLB VQC reagents we accept the NIBSC collaborative study in which calibration by a variety of methods showed that the Pelispy 380 geq/ml run control is equivalent to 100 IU/ml of the WHO standard. This multi-centre validation study demonstrates that the 95% detection limit of the NucliSens HCV Amplicor method lies far below the detection limits required by the international regulatory bodies.

Europe↗

Hepatitis G virus RNA and hepatitis G virus-E2 antibodies in Dutch hemophilia patients in relation to transfusion history.

The prevalence of hepatitis G virus (HGV)-RNA and HGV-E2 antibodies was studied in a cohort of Dutch hemophilia patients in relation to clotting products used, age, and coinfection with hepatitis C. Between 1991 and 1995, blood samples were taken from 294 patients with hemophilia A, B, or von Willebrand disease. From each patient one fresh frozen sample was tested for HGV cDNA polymerase chain reaction (PCR) and HCV cDNA PCR. Alanine aminotransferase (ALT) tests were performed on plasma samples of all patients. The presence of HGV-E2 antibodies was tested on plasma samples from a subset of 169 patients representing all age groups. Based on the origin and viral safety of the products used, three subgroups of patients were distinguished. Group A: patients who used viral noninactivated factors derived from small and large donor pools; group B: patients who used factors prepared with inadequate viral inactivation techniques derived from small and large donor pools; and group C: patients treated only with optimally viral inactivated large pool clotting factor or recombinant clotting factor concentrate. The prevalence of HGV-RNA was 18%. In group A patients the prevalence was 71%, in group B 50%, and in group C 6%. When related to age, the highest prevalence of HGV-RNA (35%) was seen in patients born between 1980 and 1989. The prevalence of HGV-E2 antibodies increased with age. Of HGV-RNA-negative patients born before 1950, 96% tested positive. HGV viremia did not affect ALT levels, neither in HCV-RNA positive nor in HCV-RNA negative patients. HGV infection is frequently seen in patients with hemophilia. In older age groups a lower rate of HGV-RNA positivity is seen coinciding with a higher rate of antienvelope antibodies.

Age Factors↗

Stability of hepatitis C virus RNA during specimen handling and storage prior to NASBA amplification.

The influence of different anticoagulants and pre-amplification storage conditions on the stability of hepatitis C virus (HCV)-RNA, as detected by the quantitative HCV NASBA assay (NASBA-QT), was studied. The HCV-RNA load remained stable for at least 15 months when serum or plasma samples (EDTA and heparin) were directly frozen at -70 degrees C in lysis buffer. At 4 degrees C, the HCV-RNA load in serum or plasma stored with lysis buffer did not decline for at least 14 days. At 30 degrees C, however, the load declined significantly after 7 days. When clotted, whole blood was stored at 4 degrees C, the HCV-RNA load was stable for 72 h. However, when EDTA-anticoagulated whole blood was stored at 4 degrees C, the HCV-RNA load declined significantly after 48 h. In paired plasma and serum samples at baseline the HCV-RNA levels were similar. Heparin did not influence the efficiency of the HCV NASBA-QT assay. Clotted blood as well as EDTA or heparin anticoagulated blood can be used for quantifying HCV-RNA using the NASBA-QT assay. Blood samples should be stored at 4 degrees C after collection and serum or plasma separated within 24 h. Preferably, after separation, samples should be frozen in lysis buffer at -70 degrees C until NASBA-QT analysis.

Buffers↗

New hepatitis B virus mutant form in a blood donor that is undetectable in several hepatitis B surface antigen screening assays.

BACKGROUND: Envelope mutant forms of hepatitis B virus (HBV), impairing HBV antibody recognition, have been reported with mutations in single or multiple sites of the hepatitis B surface antigen (HBsAg) group-specific "a" determinant. Blood donors infected with such an HBsAg mutant form of HBV may escape detection by HBsAg screening assays and therefore may affect the safety of the blood supply. CASE REPORT: A repeat blood donor became HBsAg-reactive in an enzyme immunoassay. Confirmatory testing yielded negative results for HBsAg in a radioimmunoassay and in four enzyme immunoassays used in blood donor screening. The specificity of the HBsAg reactivity in the first enzyme immunoassay was confirmed by HBsAg neutralization with antibody to HBsAg. Additional HBV confirmatory test results were positive for antibody to hepatitis B core antigen and antibody to hepatitis B e antigen; negative for antibody to HBsAg and for hepatitis B e antigen; and positive for HBV DNA. DNA sequence analysis of the "a" determinant region of HBsAg revealed amino acid substitutions from Q (Gln) to R (Arg) at codon 129 and from M (Met) to T (Thr) at codon 133. CONCLUSION: This case illustrates the presence of HBsAg mutant forms of HBV in a West European blood donor population that were undetected by several HBsAg screening assays. Adaptation of HBsAg screening is indicated to overcome deficiencies in sensitivity in detecting HBsAg mutant forms of HBV. Screening for antibody to hepatitis B core antigen or HBV DNA may also detect blood donors infected with HBsAg mutant forms of HBV

Adult↗

Validation of a new immunoblot assay (LiaTek HIV III) for confirmation of human immunodeficiency virus infection.

BACKGROUND: Used as a supplemental assay, new anti-human immunodeficiency virus (HIV) immunoblots, employing recombinant and synthetic antigens, appeared to resolve the majority of samples with false-reactive Western blot results. Would it be possible to completely replace the Western blot by an immunoblot for confirmation and exclusion of HIV infection? STUDY DESIGN AND METHODS: The sensitivity of the new LiaTek HIV III immunoblot assay (Organon Teknika, Turnhout, Belgium) was tested on 416 Western-blot positive samples (386 HIV-1, 22 HIV-2, 1 HIV-1/2, and 7 HIV-O) and on 45 HIV-1 seroconversion samples. The specificity was tested on 146 samples from noninfected donors with false-positive results on a HIV screening test. RESULTS: All Western-blot-positive samples tested positive in the immunoblot (sensitivity: 100%). The immunoblot could not discriminate between HIV-1 and HIV-2 infection in 22 of 416 (5%) samples. The LiaTek assay showed reactivity in 28 of 45 seroconversion samples, whereas the Western blot reacted in 30 of 45 seroconversion samples. With false-positive donor samples, the immunoblot was indeterminate in 10 of 146 samples (specificity: 93%), and the Western blot was indeterminate in 44 of 146 samples (specificity: 70%). CONCLUSION: Like the Western blot, the immunoblot runs the risk of missing samples that are reactive by enzyme immunoassay during the early stage of HIV infection. Nevertheless, considering its superior specificity on false-positive donor samples, it appears that the immunoblot offers a cost-effective alternative to the Western blot assay for confirmation and exclusion of HIV infection.

AIDS Serodiagnosis↗

High prevalence of parvovirus B19 IgG antibodies among Dutch hemophilia patients.

BACKGROUND AND OBJECTIVES: Human parvovirus B19 is a potential risk to hemophiliac patients receiving blood products. MATERIALS AND METHODS: To determine the prevalence of the corresponding antibody in patients with hemophilia A or B von Willebrand's disease, we tested 326 hemophilia patients for anti-B19 IgG. The results were compared with those of 203 age-matched controls (male blood donors and children). RESULTS: The overall prevalence of B19 IgG in the hemophilia patients was 302/326, and in the controls 123/203. Below the age of 10, hemophilia patients had a higher prevalence of B19 IgG (76%, 42/55) than the controls (23%, 11/48; p < 0.00001). In those below the age of 5 who had been treated exclusively with monoclonally purified concentrate, it made no difference whether the product was pasteurized or solvent-detergent treated. There was significantly lower incidence in patients who were rarely treated. CONCLUSION: Parvovirus B19 if frequently transmitted in blood products. Existing virus-inactivating methods do not prevent transmission.

Adolescent↗

[Infection with T-lymphotropic virus in Dutch blood donors, 1993-1996].

Infection with human T-lymphotrophic virus (HTLV) type 1 causes a neurological disorder or leukaemia in a minority of infected persons. Since January 1993 the Dutch blood banks screen each donation for presence of HTLV-1 infection. Approximately 4,000,000 donations from 700,000 donors have been tested. The numbers of confirmed HTLV-1 positive donors were: 1993: 15; 1994: 6; 1995: 8; 1996: 3. In 1995 one case of HTLV-2 infection was detected as well. In 26/32 (81%) of the HTLV-1 positive cases either the donor or his/her partner originated from HTLV-1 endemic areas. The introduction of HTLV screening prevents the silent spread of HTLV via blood transfusion.

Blood Donors↗

Look-back of anti-HCV ELISA-positive, HCV-RNA PCR-negative donors and recipients of their blood products.

BACKGROUND AND OBJECTIVES: To establish the infectivity of anti-HCV ELISA-positive, but cDNA-PCR-negative blood components transfused before the introduction of routine anti-HCV blood donor screening, we enrolled recipients of such blood products in a look-back programme. MATERIALS AND METHODS: The blood components were donated by (A) RIBA-2-indeterminate and cDNA-PCR-negative donors, and (B) RIBA-2 and cDNA-PCR-negative donors. The look-back comprised 214 blood products from group A donors and 278 from group B. RESULTS: Of 211 recipients of group A components, 66 (31.3%) were available for testing. All other recipients could not be traced, had died, or refused collaboration. Of these 66, 3 patients had independent risk factors for HCV infection and were excluded. All remaining 63 recipients were anti-HCV ELISA-negative. Of 274 recipients of group B components, 84 (30.7%) were available for testing. All others could not be traced, had died, or refused collaboration. Of these 84, six patients had an independent risk factor for HCV infection and were excluded. All remaining 78 recipients were anti-HCV ELISA-negative. None of the recipients of blood products from previous donations of anti-HCV ELISA-positive, cDNA-PCR-negative, and RIBA-2-indeterminate or negative donors were HCV-infected. CONCLUSIONS: Donors and patients with such reactivities in anti-HCV ELISA, RIBA-2, and cDNA-PCR can be assured that they are not infected with HCV. The donors involved can re-enter the donor pool, provided that future donations are anti-HCV ELISA-negative.

Antigens, Viral↗

Evaluation of a new HTLV-I/II polymerase chain reaction.

AIM: Evaluation of a qualitative HTLV-I/II DNA polymerase chain reaction (PCR) test for the detection of HTLV-I/II DNA (Roche Diagnostic Systems, Branchburg, N.J., USA) in various panels. METHODS: The panels consisted of fresh EDTA blood samples from blood donors who were anti-HTLV-I/II ELISA repeatably reactive: 53 were Western blot (WB) positive, 228 were WB indeterminate and 15 were WB negative. Elevent ELISA-negative blood donors were used as negative controls. Furthermore, specimens from 1 HTLV-II-infected intravenous drug user and from 1 HTLV-II-infected blood donor were included in the panel. Peripheral blood lymphocytes were prepared by red blood cell lysis with the Roche washing solution and stored at < -23 degrees C until processing. Amplification products were analyzed with the HTLV-I/II detection kit. RESULTS: All 53 anti-HTLV-I/II ELISA- and WB-positive samples and both HTLV-II-positive samples tested positively by PCR. All 228 anti-HTLV-I/II ELISA-positive and WB-indeterminate, all 15 ELISA-positive and WB-negative and all II ELISA-negative control samples tested negative by PCR. CONCLUSION: The Roche Amplicor HTLV-I/II test is a simple test, suitable for the confirmation of HTLV-I and-II infection in individuals with indeterminate or positive WB patterns.

Blood Donors↗

New anti-human immunodeficiency virus immunoblot assays resolve nonspecific western blot results.

BACKGROUND: Two new anti-human immunodeficiency virus type 1 and 2 (HIV-1/2) immunoblot assays, which use recombinant and synthetic antigens for antibody detection have become available. These assays might be able to resolve indeterminate anti-HIV Western blot results. STUDY DESIGN AND METHODS: The new anti-HIV immunoblot assays were used to test 67 samples from 31 HIV infected and 24 noninfected persons showing various anti-HIV Western blot patterns. RESULTS: The immunoblots correctly identified eight HIV-2-positive samples and five late-stage HIV-1-positive samples. After 30 samples from 18 seroconverting persons were tested, the Western blot showed reactivity in 24 of 30 samples and the immunoblots showed reactivity in 21 of 30 samples (difference not significant). In 16 of 30 seroconversion samples, both immunoblot assays produced HIV-1-positive results. In accordance with various criteria for interpretation, the number of positive Western blot results was as follows: Centers for Disease Control and Prevention, 16 of 30 and World Health Organization, 13 of 30. When samples from non-HIV-infected persons were tested, both immunoblot assays resolved 20 (83%) of 24 samples showing indeterminate Western blot reactivity. CONCLUSION: Although the sensitivity of the immunoblot assays should be validation in larger studies, the mere specificity of these assays makes them valuable for the exclusion of HIV infection in Western blot-indeterminate, HIV p24 antigen-negative samples.

Blotting, Western↗

Performance of three generations of anti-hepatitis C virus enzyme-linked immunosorbent assays in donors and patients.

BACKGROUND: Prevention of posttransfusion non-A,non-B hepatitis in recipients of blood components improved considerably with the introduction of the second-generation of hepatitis C virus (HCV) antibody tests. In 1993, third-generation HCV antibody assays were introduced in Europe. STUDY DESIGN AND METHODS: The performance of three generations of anti-HCV enzyme-linked immunosorbent assay (ELISA) (ELISA-1, -2, -3) was compared in routine blood donor screening (99,394 donations were tested with ELISA-1, 167,999 donations with ELISA-2, and 262,090 donations with ELISA-3) and in serial samples from nine patients with documented acute posttransfusion HCV infection. RESULTS: Eight (0.01%) repeat donors, previously negative in ELISA-1, were found positive in ELISA-2 and were confirmed as positive in second-generation recombinant immunoblot assay and/or cDNA polymerase chain reaction. In the donor population, no difference in the sensitivity of ELISA-2 and -3 was observed. The specificity of the three generations of ELISAs was comparable (99.8, 99.7, and 99.7%). In seroconversion samples, ELISA-2 and -3 detected HCV antibodies at the same time in seven patients, but in two patients, ELISA-3 found HCV antibodies, respectively, 63 and 77 days earlier than ELISA-2 did. In the seroconversion samples, ELISA-2 and -3 were significantly more sensitive than second- and third-generation recombinant immunoblot assays. CONCLUSION: ELISA-3 did not detect more HCV-infected individuals in a donor population that previously tested negative in ELISA-2, but it did detect HCV antibodies earlier in some patients with acute HCV infection. ELISA-2 and -3 were significantly more sensitive than second- and third-generation recombinant immunoblot assays.

Blood Donors↗

Temporary seronegativity in a human immunodeficiency virus type 1-infected man.

Over a period of 3 months a human immunodeficiency virus 1 (HIV-1)-infected patient showed a sequence of positive-negative-positive anti-HIV screening test results. During this period the level of HIV p24 antigen declined and the HIV antibody pattern by Western blot gradually became complete, suggesting recent HIV infection. However the patient's weight loss, esophageal candidiasis, and Pneumocystis carinii pneumonia, together with the severely and persistently lowered CD4 cell counts and the absence of an IgM anti-HIV response, suggest late-stage HIV infection. Despite additional and follow-up testing, it was impossible to determine whether the patient suffered from acute, primary HIV infection with severe immunodepression or from advanced HIV infection (AIDS) with hampered HIV antibody production leading to false-negative test results by the anti-HIV enzyme immunoassay and Western blot. This case illustrates that HIV serology does not always follow the rules. The presence of HIV infection should be considered in a patient showing clinical signs of acute or late-stage HIV infection, even if the anti-HIV assay is negative.

Acquired Immunodeficiency Syndrome↗

International collaborative study on the second EUROHEP HCV-RNA reference panel.

Eighty-six laboratories participated in a collaborative study and tested the second EUROHEP HCV-RNA reference panel. The coded panel comprised 4 HCV-RNA positive plasma samples (one weak positive), 6 HCV-RNA negative plasma samples and two dilution series of HCV-RNA genotype 1 and 3 plasma standards. The 86 laboratories submitted 136 coded data forms for evaluation. Of these data sets 99 were tested using a PCR assay developed in-house, 28 using a commercially available HCV-PCR test (AMPLICOR, Roche Diagnostic Systems) and 9 using other amplification methods. Twenty-two data forms (16%) had faultless results, 39 (29%) missed the weak positive sample only and 75 data sets (55%) had false positive and/or false negative results. Participants using the commercial HCV-PCR test tended to reach a sufficient quality score more often than investigators using assays developed in-house (64% versus 45%, P = 0.11). The UNG system in the commercial HCV-PCR test did not prevent five laboratories generating false-positive results in the 6 HCV-RNA negative samples. Among the laboratories with satisfactory results, up to 10000-fold differences in sensitivity were observed in the dilution series. The 50% and 90% laboratories detection endpoints in the dilution series of the HCV genotype 1 plasma standard were approximately 600 genome equivalents per ml (geq/ml) and 7750 geq/ml according to a standard applied in a signal amplification assay (bDNA, Chiron). Our results suggest that the detection efficiency for genotype 3 by commercial HCV-RNA assays is lower than by the in-house assays. Internationally characterized HCV-RNA plasma standards should be made available for validation and standardization of HCV-RNA assays for HCV diagnosis and virological safety testing of blood products.

Hepacivirus↗