Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania.

Without the knowledge of reference dose levels (RDLs) from computed tomography (CT) examinations, the optimal dose to patients undergoing CT examinations cannot be realised. The aim of this study was therefore to assess the radiation dose levels from CT examinations according to reference dose quantities proposed by the European Commission (EC) guidelines. The dosimetric quantities proposed in the EC for CT are weighted CT dose index (CTDI(w)) for a single slice and dose-length product (DLP) for a complete examination. The RDLs from five common CT examinations were obtained from eight hospitals. The RDLs in terms of CTDI(w) and DLP were estimated from measurements of CTDI in standard phantoms using typical exposure parameters. Mean values of CTDI(w) for head and lumbar spine had a range of 25-77 and 18-47 mGy, respectively, while those for chest, abdomen and pelvis had a range of about 11-25 mGy, respectively. Mean values of DLP for head, chest and abdomen had a range of 610-1684, 496-992 and 717-1428 mGy cm, respectively, while those for lumbar spine and pelvis had a range of 200-382 and 526-1302 mGy cm, respectively. Wide variations of mean CTDI(w) and DLP values among hospitals observed for similar CT examinations were mainly attributed to the variations of CT scanning protocols and scanner types. The mean CTDI(w) values per examination for almost all hospitals were below proposed RDLs, while the mean DLP values per examination were almost all above the proposed RDLs for all except one hospital. These were mainly influenced by the large scan length used in Tanzanian hospitals. In order to achieve the required level of dose for establishment of the national RDLs, it was concluded that further investigation of optimization of scanning protocols is needed.

Body Burden↗

Current status of patient radiation doses from computed tomography examinations in Tanzania.

The aim of this study was to assess the magnitude of radiation dose imparted to patients undergoing CT (computed tomography) examinations in Tanzania. The effective doses to patients undergoing five common CT examinations were obtained from eight health centres. The doses to patients were estimated using measurements of CTDI, exposure-related parameters and the CTDOSE software based on NRPB conversion factors. The mean effective doses in Tanzania for CT examinations of head, lumbar spine, chest, abdomen and pelvis were 2.2+/-0.9, 5.4+/-2.3, 12.2+/-3.4, 15.3+/-6.0 and 13.4+/-7.3 mSv, respectively. The mean effective doses and the variations in dose between hospitals in Tanzania were mostly comparable with reported values in the literature for six different countries from Europe. The observed wide variation in mean effective dose for similar CT examination among hospitals was largely influenced by different CT scanning protocols employed among hospitals. In view of the observed causes of variation in patient doses, it was concluded that further studies are needed to investigate the methods that can reduce dose to patients without affecting image quality.

Humans↗

A survey of background radiation dose rates and radioactivity in Tanzania.

Potential terrestrial sources of naturally occurring elevated radiation levels have been identified in Tanzania. Thus, efforts are currently being undertaken to create a natural radiation database, in the form of a radiation level map of natural radioactivity, to be used to assess the associated radiation risk to public and workers. Background radiation dose rate was determined with thermoluminescent dosimeters for 7 y (1993-1999) in five stations. The average background radiation dose rates for these stations were as follows: Tropical Pesticides Research Institute (TPRI) (102 +/- 7 nGy h(-1)), Same (98 +/- 2 nGy h(-1)), Namanga (98 +/- 5 nGy h(-1)), University of Dar Es Salaam (99 +/- 2 nGy h(-1)), and Kilimanjaro Christian Medical Center (121 +/- 3 nGy h(-1)). These stations were found convenient from an economic point of view since the project has no funds to cover wider and/or more remote areas in Tanzania. For the sake of comparison, similar measurements were made for the same period at Minjingu phosphate mine. The mine was one of the suspected areas with elevated levels of natural radioactivity. The radiation dose rate measured in this mine was about fourteen times higher (1,415 +/- 28 nGy h(-1)) than the average value obtained in northern Tanzania (98 nGy h(-1)). The high average activity levels of phosphate (5760 +/- 107 Bq kg(-1) for 261Ra, 497 +/- 5 Bq kg(-1) for 228Ra, 350 +/- 6 Bq kg(-1) for 228Th, and 280 +/- 5 Bq kg(-1) for 40K) and radiation dose rate recorded show that Minjingu phosphate mine has higher values than the highest radioactivity in phosphate compiled by the United Nations Scientific Committee on the Effect of Atomic Radiation. In view of these findings, a comprehensive risk-management strategy for reduction of radiation risk to the public and mine workers should be put in place. Efforts are currently being made to seek support to improve the background radiation database for subsequent assessment of radiation risk to miners and the societies in the vicinity of these mines in Tanzania.

Background Radiation↗

The relative contributions of scatter and attenuation corrections toward improved brain SPECT quantification.

Mounting evidence indicates that scatter and attenuation are major confounds to objective diagnosis of brain disease by quantitative SPECT. There is considerable debate, however, as to the relative importance of scatter correction (SC) and attenuation correction (AC), and how they should be implemented. The efficacy of SC and AC for 99mTc brain SPECT was evaluated using a two-compartment fully tissue-equivalent anthropomorphic head phantom. Four correction schemes were implemented: uniform broad-beam AC, non-uniform broad-beam AC, uniform SC + AC, and non-uniform SC + AC. SC was based on non-stationary deconvolution scatter subtraction, modified to incorporate a priori knowledge of either the head contour (uniform SC) or transmission map (non-uniform SC). The quantitative accuracy of the correction schemes was evaluated in terms of contrast recovery, relative quantification (cortical:cerebellar activity), uniformity ((coefficient of variation of 230 macro-voxels) x 100%), and bias (relative to a calibration scan). Our results were: uniform broad-beam (mu = 0.12 cm(-1)) AC (the most popular correction): 71% contrast recovery, 112% relative quantification, 7.0% uniformity, +23% bias. Non-uniform broad-beam (soft tissue mu = 0.12 cm(-1)) AC: 73%, 114%, 6.0%, +21%, respectively. Uniform SC + AC: 90%, 99%, 4.9%, +12%, respectively. Non-uniform SC + AC: 93%, 101%, 4.0%, +10%, respectively. SC and AC achieved the best quantification; however, non-uniform corrections produce only small improvements over their uniform counterparts. SC + AC was found to be superior to AC; this advantage is distinct and consistent across all four quantification indices.

Alzheimer Disease↗

Pre-processing variance reducing techniques in multispectral positron emission tomography.

Stochastic fluctuations and systematic errors severely restrict the potential of multispectral acquisition to improve scatter correction by energy-dependent processing in high-resolution positron emission tomography (PET). To overcome this limitation, three pre-processing approaches which reduce stochastic fluctuations and systematic errors without degrading spatial resolution were investigated: statistical variance was reduced by smoothing acquired data in energy space, systematic errors due to nonuniform detector efficiency were minimized by normalizing the data in the spatial domain and the overall variance was further reduced by selecting an optimal pre-processing sequence. Selection of the best protocol to reduce stochastic fluctuations entailed comparisons between four smoothing algorithms (prior constrained (PC) smoothing, weighted smoothing (WS), ideal low-pass filtering (ILF) and mean median (MM) smoothing) and permutations of three pre-processing procedures (smoothing, normalization and subtraction of random events). Results demonstrated that spectral smoothing by WS, ILF and MM efficiently reduces the statistical variance in both the energy and spatial domains without observable spatial resolution loss. The ILF algorithm was found to be the most convenient in terms of simplicity and efficiency. Regardless of the position of subtraction of randoms in the sequence, reduction of the systematic errors by normalization followed by spectral smoothing to suppress statistical noise produced the best results. However, subtraction of random events first in the sequence reduces computation load by half since the need to pre-process this distribution before subtraction is removed. In summary, normalizing data in the spatial domain and smoothing data in energy space are essential steps required to reduce systematic errors and statistical variance independently without degrading spatial resolution of multispectral PET data.

Biophysical Phenomena↗

Nonstationary scatter subtraction-restoration in high-resolution PET.

UNLABELLED: Although removal of object scatter has been shown to improve both contrast and quantitation accuracy, subtraction of detector scatter leads to marginal contrast enhancement and negligible resolution recovery at the expense of reduced sensitivity and increased statistical noise. Since detector scatter has correct information about radioactivity but slightly erroneous information about source location, we suggest that this component should be restored to preserve sensitivity and improve resolution. METHODS: A scatter correction model that consecutively removes object scatter and restores detector scatter is proposed. The scatter components are processed in the spatial domain using nonstationary scatter kernels. The detector scatter restoration kernel is obtained by piecewise inversion in the Fourier space. The model was tested using line source and hot spot phantom measurements. RESULTS: Object scatter subtraction increased contrast substantively with no effect on resolution. Detector scatter restoration recovered resolution almost completely with modest contrast enhancement in small lesions. Spillover effects were reduced to less than 5% for hot spots > or = 3 x FWHM, at the expense of moderate noise amplification. CONCLUSION: While subtraction of object scatter is necessary for contrast enhancement and quantitation accuracy, restoration of detector scatter preserves sensitivity and improves quantitation accuracy by reducing spillover effects in high-resolution PET.

Image Enhancement↗

Assessment of scatter components in high-resolution PET: correction by nonstationary convolution subtraction.

UNLABELLED: This paper describes a new approach to determine individual scatter kernels and to use them for scatter correction by integral transformation of the projections. METHODS: Individual scatter components are fitted on the projections of a line source by monoexponentials. The position-dependent scatter parameters of each scatter components are then used to design non-stationary scatter correction kernels for each point in the projection. These kernels are used in a convolution-subtraction method which consecutively removes object, collimator and detector scatter from projections. This method is based on a model which assumes that image degradation results exclusively from Compton interactions of annihilation photons, thus neglecting further Compton interactions of object scatters with collimator and detector. RESULTS: Subtraction of the object scatter component improved contrast typical of what is obtained with standard convolution-subtraction methods. The collimator scatter component is so weak that it can be safely combined with object scatter for correction. Subtraction of detector scatter from images did not improve contrast because statistical accuracy is degraded by removing counts from hot regions while cold regions (background) remain unchanged. CONCLUSION: Subtraction of object and collimator scatter improves contrast only. The slight gain in image sharpness resulting from the subtraction of detector scatter does not justify removal of this component at the expense of sensitivity.

Humans↗

Position-dependent scatter response functions: will they make a difference in SPECT conducted with homogeneous cylindrical phantoms?

This paper explains why it is possible to perform accurate quantitative SPECT when scatter correction is based on stationary and non-stationary scatter functions. This is achieved by comparing the variations of scatter parameters as a function of phantom thickness. The results show that the decrease of scatter fraction with phantom thickness and the decrease of values of scatter kernel inside the field of view are about equal. The deviation of the position-dependent slope from the average value is small for central distributions. These observations explain why estimations of scatter projection by non-stationary convolution and by stationary convolution are comparable when SPECT measurements are conducted with uniform cylindrical phantoms. It is concluded that investigations on the perceived superiority of non-stationary over stationary scatter subtraction in SPECT should be conducted with elliptic phantoms that deviate appreciably from cylindrical shape.

Algorithms↗

Some physical factors influencing the accuracy of convolution scatter correction in SPECT.

Some important physical factors influencing the accuracy of convolution scatter correction techniques in SPECT are presented. In these techniques scatter correction in the projection relies on filter functions, QF, evaluated by Fourier transforms, from measured scatter functions, Qp, obtained from point spread functions. The spatial resolution has a marginal effect on Qp. Thus a single QF can be used in the scatter correction of SPECT measurements acquired with the low energy high resolution or the low energy general purpose collimators and over a wide range of patient-collimator distances. However, it is necessary to examine the details of the shape of point spread functions during evaluation of Qp. QF is completely described by scatter amplitude AF, slope BF and filter sum SF. SF is obtained by summation of the values of QF occupying a 31 x 31 pixels matrix. Regardless of differences in amplitude and slope, two filter functions are shown to be equivalent in terms of scatter correction ability, whenever their sums are equal. On the basis of filter sum, the observed small influence of ellipticity on QF implies that an average function can be used in scatter correcting SPECT measurements conducted with elliptic objects. SF is shown to increase with a decrease in photon energy and with an increase in window size. Thus, scatter correction by convolution may be severely hampered by photon statistics when SPECT imaging is done with low-energy photons. It is pointless to use unnecessarily large discriminator windows, in the hope of improving photon statistics, since most of the extra events acquired will eventually be subtracted during scatter correction. Regardless of the observed moderate reduction in SF when a lung-equivalent material replaces a portion of a water phantom, further studies are needed to develop a technique that is capable of handling attenuation and scatter corrections simultaneously. Whenever superficial and inner radioactive distributions coexist the observed reduction of SF close to the phantom surface indicates that scatter correction of such distributions has to rely on two distinct filter functions. Corrections based on a surface function produce accurate results in the superficial region, while the central distributions are substantially overestimated. Surface radioactive distributions introduce appreciable errors in the determination of central distributions when corrections are based on central filter function. This function introduces a reduction of about 40% in the measured surface concentration.

Humans↗

Generalized scatter correction method in SPECT using point scatter distribution functions.

A new two-dimensional (2-D) scatter correction technique in single photon emission computed tomography (SPECT) based on convolution or frequency filtering with a 2-D scatter distribution function is described. A scatter distribution function of the form A exp(-Br), has been derived from measurements of a point source in a water phantom. Both the amplitude A and the slope B of this function, were approximately invariant with source position except near phantom surface. The accuracy of the 2-D correction technique was compared with that of the previous one-dimensional (1-D) scatter correction technique. As could be expected the latter technique was shown to be less accurate due to its dependence on axial distribution of radioactivity. Phantom SPECT studies showed a clear superiority of the 2-D over the 1-D scatter correction in quantitative imaging. Images derived from clinical studies of regional bloodflow with 99mTc-HM-PAO and liver uptake showed significant contrast improvement by both techniques.

Scattering, Radiation↗

Subtraction of Compton-scattered photons in single-photon emission computerized tomography.

A technique for scatter correction in single photon emission computerized tomography (SPECT) is described. The method is based on "deconvolution" of scattered events from the measured profile data. The function defining the scatter distribution was determined from measurements with a line source in circular and rectangular water phantoms. The accuracy of the method was tested on a simple phantom simulating a SPECT investigation of the liver. The indicated ratio of the activity concentration in a photon-deficient area, 60 mm diameter in the "liver", relative to its surroundings, was 0.28/1 without scatter correction and 0.01/1 with the correction.

Liver↗