Clinical and angiographic outcome after coronary arterial stenting with the carbostent.

The Carbostent is a new balloon-expandable, stainless steel, tubular stent with innovative multicellular design and unique turbastratic carbon coating (Carbofilm). This open nonrandomized 2-center study assesses the immediate and long-term clinical and angiographic outcomes after Carbostent implantation in patients with native coronary artery disease. The Carbostent was implanted in 112 patients with 132 de novo lesions. Most patients (55%) had unstable angina, and 38% of lesions were type B2-C. The mean lesion length was 12.5 +/- 7.0 mm, and 29% of lesions were > 15 mm in length. No stent deployment failure occurred, as well as acute or sub-acute stent thrombosis. The 6-month event-free survival was 84 +/- 4%. One patient with a stented right coronary artery and no restenosis at the angiographic follow-up died after 6 months of fatal infarction due to abrupt closure of a nontarget vessel. In-hospital non-Q-wave myocardial infarction occurred in 1 patient, and 11 patients had repeat target lesion revascularization (target lesion revascularization rate 10%). The 6-month angiographic follow-up was obtained in 108 patients (96%) (127 lesions). Angiographic restenosis rate was 11%. The loss index was 0.29 +/- 0.28. The results of this study indicate a potential benefit of Carbostent for the prevention of stent thrombosis and restenosis in these relatively high-risk patients. A larger trial is being planned to confirm these promising results.

Adult↗

Role of cine-fluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis.

Prosthetic heart valve thrombosis (PVT) is a rare but potentially life-threatening complication of heart valve replacement. An effective, quick, and easy diagnostic method is highly desirable. We evaluated the diagnostic efficacy of cine-fluoroscopy (CF), transthoracic (TTE), and transesophageal (TEE) echocardiography in 82 consecutive patients with mechanical valves and suspected PVT. Criteria for PVT were: leaflet(s) motion restriction at CF, increased Doppler gradients at TTE, and evidence of thrombi at TEE. Patients were divided in 4 groups (A, B, C, and D) according to results of CF and TTE. Group A was composed of 24 patients with positive CF and TTE. Thrombi were detected by TEE in all cases, suggesting that when both are positive, CF and TTE correctly identified PVT in all patients so that TEE may be deferred. Group B was composed of 12 patients with positive CF and negative TTE; TEE showed PVT in 4 patients (33%). These patients had very slight leaflet motion restriction as in the case of initial PVT. This suggests that CF compared with Doppler may identify patients with "hemodynamically significant" PVT. The remaining 8 patients in this group had monocuspid prostheses with negative TEE, suggesting that abnormal leaflet motion at CF may be due to functional changes. Therefore, TEE should always be performed in case of monocuspid prostheses with isolated CF abnormalities. Group C was composed of 18 asymptomatic patients with small-sized aortic prostheses and very high Doppler gradients on routine TTE. CF showed normal leaflet motion and TEE ruled out PVT in all cases outlining the diagnostic role of CF in this particular subset. Finally, group D was composed of 28 patients with negative CF and TTE. TEE did not show thrombi in 24 of 28 patients (86%), confirming that, when both yield negative results, CF and TTE are reliable methods to rule out valve thrombosis in most cases. However, in 4 of 28 patients (14%) TEE showed "nonobstructive" prosthetic thrombosis: these patients had mitral prostheses, chronic atrial fibrillation, and 3 of 4 had systemic embolisms. Thus, TEE should be performed in selected patients despite negative CF and TTE results. Sensitivity, specificity, and positive and negative predictive values were 87%, 78%, 80%, and 91% for CF and 75%, 64%, 57%, and 78% for TTE, respectively. CF and TTE correctly identified PVT in 70 of 82 patients (85%). TEE was actually required in 15% of the cases. Thus, CF and TTE are quick, effective, and complementary diagnostic tools to diagnose PVT in most patients. TEE still remains the gold standard technique in selected cases.

Aged↗

Use of a new diagnostic catheter for transradial internal mammary artery angiography early after minimally invasive coronary bypass.

We describe a new diagnostic catheter specifically designed for selective catheterization of the left internal mammary artery via the ipsilateral radial approach. We used this catheter to assess the patency of the distal mammary-left anterior descending coronary artery anastomosis in 30 consecutive patients early after minimally invasive direct coronary artery bypass grafting. The new catheter design allowed easy and fast engagement of the left internal mammary artery leading to optimal vessel opacification in all cases. Angiography revealed graft problems in seven (23.3%) patients, two of whom required anastomosis revision, surgical in one case and with PTCA in the other. No LIMA injury occurred as a result of selective catheterization. Patients with functionally normal anastomosis were discharged on the same day of the diagnostic procedure.

Aged↗

Elective coronary stent implantation in cardiogenic shock complicating acute myocardial infarction: in-hospital and six-month clinical and angiographic results.

Effective treatment of patients with acute myocardial infarction and cardiogenic shock depends on restoring persistent patency of the infarct-related artery. Coronary stenting, reducing abrupt or delayed closure related to dissection and suboptimal result, may improve PTCA results in cardiogenic shock. Eighteen patients (14 males and 4 females, mean age 59 +/- 7 years), referred to catheterization laboratory for acute myocardial infarction and shock, had elective stent implantation during 14 primary and 4 rescue PTCA. Time delay between shock onset and PTCA was 4.1 +/- 3 hr (range, 30 min to 12 hr). The IRA was LAD in seven patients (38%), LCx in two (11%), and RCA in eight (45%). One patient (5.%) had distal LMCA occlusion. Stent deployment was successful in 100% of patients and resulted in TIMI 3 flow in 13 (72%) patients. In 13 (72%) cases, cardiogenic shock gradually resolved and the patients were discharged alive. Five patients (28%) died because of irreversible hemodynamic deterioration without evidence of reinfarction. At 6-month follow-up, all the discharged patients were alive and no patient had reinfarction or recurrent angina. Heart transplant was required in one patient 5 months after stenting because of refractory congestive heart failure. Angiography demonstrated patency of all the coronary arteries treated, with TIMI 3 flow in all patients. Stent restenosis rate was 30%, and target lesion revascularization with CABG or re-PTCA was not required in any case. LV function improved from 39% +/- 15% to 51% +/- 15% (P < 0.01). Elective coronary stenting is an effective treatment for acute myocardial infarction complicated by cardiogenic shock and may improve acute and long-term survival.

Aged↗

Thrombosis of mechanical heart valve prostheses: revisiting the role of fluoroscopy.

Prosthetic valve thrombosis is a rare but potentially fatal complication of heart valve replacement. Symptoms may be misleading, yet the condition may rapidly lead to death. A prompt diagnosis is therefore crucial. Ultrasound is the most often used technique for evaluating prosthesis dysfunction. We describe two cases of prosthesis thrombosis with negative Doppler results but with distinctly abnormal leaflet motion at fluoroscopy. A correct diagnosis would have been missed if the Doppler evaluation alone was relied on. Fluoroscopy should always form part of the diagnostic work-up in patients with artificial heart valves.

Coronary Thrombosis↗

Successful stent delivery with deep seating of 6 French guiding catheters in difficult coronary anatomy.

Despite improvements in coronary stent design, delivery difficulties may still be encountered. Between April 1996 and September 1998, 945 patients underwent coronary stenting in our Institute. New 6 Fr Long Brite Tip (LBT) guiding catheters, allowing deep coronary artery intubation and increased backup support, were used in 25 (2.6%) of these patients presenting complex coronary anatomy and poor stent accessibility, electively in 3 (12%) and after stent delivery failure with multiple (2.1 +/- 1.2) standard guiding catheters in 22 (88%). Deep coronary artery intubation (>/= 20 mm) was successfully performed in 22 (88%) patients and was associated with adequate pressure recording and contrast opacification without blood flow compromise. Ten (22.7%) Palmaz-Schatz stents and 34 (77.3%) second-generation stents of various lengths were successfully delivered to different coronary vessels (RCA = 15, LAD = 9, LCx = 1) in all patients in whom deep coronary intubation was obtained. These data demonstrate that deep coronary artery cannulation with LBT catheters is feasible and safe and may markedly increase the rate of stent delivery success in very complex coronary anatomy and when standard guiding catheters have failed.

Angioplasty, Balloon, Coronary↗

[Anomalous origin of the sinus node artery from the left main trunk: a potential cause of iatrogenic hypokinetic arrhythmia].

The sinus node artery (SNA) arises from the right coronary artery in near 60% of the cases and from the left circumflex artery in the remaining ones. We described the case of a patient in whom the SNA took off from the proximal part of the left main trunk. A 59 year-old male underwent coronary arteriography because of unstable angina. Soon after the incannulation of the left coronary ostium with a 7F catheter critical bradycardia ensued without ECG changes of ischemia. The arrhythmia spontaneously reverted by removing the catheter. Further contrast injections were carried out with a smaller diagnostic catheter (5F); the left main trunk was normal with the SNA arising from the very proximal part of it. It is likely that the heart rate slowing was elicited by a temporary occlusion (and related ischemia) of the anomalous SNA by the diagnostic catheter. This anomaly may therefore provoked heart arrhythmias during diagnostic or interventional procedures.

Arrhythmias, Cardiac↗

Local heparin delivery prior to coronary stent implantation: acute and six-month clinical and angiographic results.

Stents increase smooth muscle cell proliferation, which may also lead to in-stent restenosis. A local delivery strategy provides higher drug concentration at the angioplasty site and may limit the proliferative response following stenting. Local heparin delivery was attempted in 35 patients following balloon angioplasty using an "over-the-balloon" style catheter (infusion sleeve). The infusion sleeve was successfully tracked and heparin was delivered in 33 (94%) patients. Heparin (1,000 IU/ml) was delivered under low (45 psi, 2 ml, n = 4), intermediate (75 psi, 4 ml, n = 11), and high (100 psi, 4 ml, n = 18) proximal infusion pressures. Stent placement was successful in all cases. Acute and in-hospital complications were a severe arterial spasm after heparin delivery, a non Q-wave myocardial infarction, and two vascular complications. Ten dissections were observed after PTCA and prior to heparin delivery. Of these dissections, 7 remained unchanged, 2 worsened, and 1 improved with local delivery. When heparin was delivered in the absence of dissection, no new dissections were observed. Of the 33 patients who received heparin, 30 (91%) had no symptoms and a negative exercise test at clinical follow-up. QCA analysis of 6-month follow-up angiograms, performed in 32 of 33 (97%) patients, demonstrated an acute gain of 1.98 +/- 0.67 mm, a late loss of 0.94 +/- 0.78 mm, a net gain of 1.04 +/- 0.78 mm, and a loss index of 0.48 +/- 0.32. Restenosis (> or = 50% stenosis) was observed in 4 of 32 (12%) patients. Local delivery of heparin via the infusion sleeve following PTCA and prior to stent deployment is feasible with an acceptable safety profile and a low clinical and angiographic restenosis rate at 6 months.

Angioplasty, Balloon, Coronary↗

Changes in right ventricular filling dynamics during left anterior descending, left circumflex and right coronary artery balloon occlusion.

AIM: Transient coronary artery occlusion during percutaneous transluminal coronary angioplasty may cause left ventricular diastolic dysfunction. The aim of this study was to evaluate the effect of left anterior descending, left circumflex and right coronary artery balloon occlusion on right ventricular diastolic function. METHODS: Thirty-five patients with single-vessel coronary artery disease and no previous myocardial infarction were selected. Left and right ventricular filling pressures were monitored by Doppler echocardiography and haemodynamic monitoring. This was performed during and immediately after 60 s of coronary balloon occlusion of the left anterior descending artery in 21 cases (Group 1), the left circumflex artery in eight cases (Group 2) and the right coronary artery in six cases (Group 3). Doppler analysis of left and right ventricular filling included peak velocity of early (PFVE) and late ventricular filling (PFVA) and PFVE to PFVA ratio (PFVE/PFVA). RESULTS: In all three groups, balloon inflation induced a significant increase in left and right filling pressures (P < 0.05). No qualitative difference in haemodynamic changes was found between groups during inflation. Significant impairment in the Doppler pattern of left and right ventricular filling occurred after 20 s of coronary occlusion: PFVE values in mitral and tricuspid valves decreased by 14% and 25% in Group 1, 13% and 25% in Group 2, and 10% and 21% in Group 3, respectively, as PFVA remained unchanged in all groups, the PFVE/PFVA ratio of mitral and tricuspid valve flows significantly decreased (Group 1: -12% and -20%, Group 2: -10% and -21%, Group 3: -14% and -21%, respectively). All parameters returned to baseline within 30 s after each balloon deflation. CONCLUSION: Our data suggest that brief episodes of acute myocardial ischaemia, such as those induced by 60 s of coronary artery occlusion during percutaneous transluminal coronary angioplasty, elicit simultaneous diastolic dysfunction of both ventricles, independent of the coronary artery involved.

Angioplasty, Balloon, Coronary↗

Failure of Fluoroscopy and Success of Intravascular Ultrasound to Locate an Intracoronary Embolized Palmaz-Schatz Stent.

We describe a patient in whom one half (disarticulated) Palmaz-Schatz stent was lost during a failed stenting procedure of an ostial left anterior coronary artery (LAD) stenosis. The embolized stent could not be located by fluoroscopy and was found in the left main coronary artery by intravascular ultrasound. The stent could not be removed using a retrieval device and was successfully deployed in the left main coronary artery by high-pressure balloon dilatation. Subsequently, LAD stenosis was successfully treated with deployment of two additional half Palmaz-Schatz stents.

Journal Article↗

[Implantation of the Palmaz-Schatz stent in coronary vessels irrigating and non-irrigating necrotic myocardial areas: comparison of acute results and at mid-term].

Recent evidence suggests that higher restenosis rate is observed after coronary angioplasty of an infarct-related artery. Furthermore, angiographic restenosis seems associated with a deterioration of left ventricular function at follow-up. The aim of this study was to assess the acute results and angiographic restenosis following coronary artery stenting of infarct-related (Group 1) and non infarct-related coronary arteries (Group 2). We retrospectively analyzed the results of 381 consecutive patients treated with Palmaz-Schatz coronary stent implantation between May 1992 and January 1996. Stenting of the infarct-related artery was performed in 154 patients (Group 1), while 227 patients (Group 2) received stenting of the non infarct-related artery. Both groups had similar age, gender, clinical conditions and coronary angiographic pattern. There were no significant differences between groups, concerning type of stented coronary vessel (left anterior descending-LAD 52.4% vs non-LAD 47.6%, Group 1, LAD 59.5% vs non-LAD 40.5%, Group 2) and number of stents per patient (1.31 +/- 0.48 in Group 1, 1.18 +/- 0.56 in Group 2) and per coronary vessel (1.17 +/- 0.54 in Group 1, 1.09 +/- 0.46 in Group 2). The procedure was performed using similar maximal inflation pressures in both groups (13.3 +/- 2.9 atm in Group 1, 13.40 +/- 3.17 atm in Group 2). Technical success was achieved in 96.8% of Group 1 and in 96% of Group 2 patients. Acute coronary stenting success and major adverse events (acute myocardial infarction, emergency bypass, death) were similar in both groups of patients. No difference was found in restenosis rate at 6-month angiographic follow-up (Group 1 = 29.8%, Group 2 = 27%). In conclusion, this study indicates that stenting of infarct and non infarct-related coronary arteries has similar success and 6-month restenosis rates.

Coronary Circulation↗

Treatment of ostial lesions of the left anterior descending coronary artery with Palmaz-Schatz coronary stent.

We evaluated acute and long-term clinical and angiographic results of elective Palmaz-Schatz coronary stent implantation for left anterior descending coronary artery (LAD) ostial stenosis in 23 consecutive patients. Eight patients had stable angina, 14 had unstable angina, and 1 had recent myocardial infarction. Sixteen patients had single-vessel, 5 had double-vessel, and 2 had triple-vessel disease. Clinical success without major complications (death, acute myocardial infarction, emergency coronary artery bypass grafting) was obtained in all cases and technical success in 20 cases (86.9%). After stenting, minimal lumen diameter increased from 1.05 +/- 0.45 mm to 2.89 +/- 0.52 mm (p < 0.001), and percent diameter stenosis decreased from 65.49% +/- 13.36% to 2.94% +/- 19.93% (p < 0.001). One case of subacute thrombosis and no major bleeding occurred. Twenty patients were followed-up for 6 months, during which no acute cardiac event (death, acute myocardial infarction) was observed. Eighteen patients were eligible for follow-up coronary angiography; restenosis (> or = 50% diameter stenosis) was observed in 4 (22.2%). Minimal lumen diameter was 1.77 +/- 0.55 mm, percent diameter stenosis was 39.66% +/- 17.62%, late loss was 1.01 +/- 0.69 mm, net gain was 0.79 +/- 0.55 mm, and loss index (late loss/acute gain) was 0.53 +/- 0.37. This study suggests that elective Palmaz-Schatz stent implantation may be a safe and successful treatment of LAD ostial lesions and provides a large increase in lumen diameter.

Angioplasty, Balloon, Coronary↗

Valve design characteristics and cine-fluoroscopic appearance of five currently available bileaflet prosthetic heart valves.

Bileaflet prostheses are low profile, central flow orifice devices that show excellent hemodynamic performance and low thrombogenicity. Five models are currently used for heart valve replacement. Comprehensive and comparative studies regarding valve characteristics and functioning are lacking, making the updating and the familiarization by physicians and cardiologists with these prostheses difficult. We describe the valve design characteristics and evaluate the cine-fluoroscopic appearance and functioning of 387 bileaflet prostheses that have been implanted in 367 consecutive patients. The valve types are St Jude Medical (n = 69), Edwards-Duromedics (n = 74), Carbomedics (n = 1290) Sorin Bicarbon (n = 88) and Jyros (n = 27). The prostheses' fluoroscopic appearance was evaluated through multiple radiographic views (Siemens-Elema equipment with C-arm); the prostheses' functional evaluation was performed by obtaining the "tilting disk projection" (ie, with the radiographic beam parallel to both the valve ring plane and the tilting axis of disks) to calculate opening, closing, and travel angles of the disks. This study shows that each of the five bileaflet valves has distinctive design characteristics. Fluoroscopy is an easy, readily available, and useful technique that correctly identifies the prosthesis type and properly evaluates its functioning in the majority of cases.

Aortic Valve↗