A rapid one-stage whole-blood HPA-1a phenotyping assay using a recombinant monoclonal IgG1 anti-HPA-1a.

Severe neonatal alloimmune thrombocytopenia and patients with HPA-1a-specific antibodies require transfusion of HPA-1a-negative platelets. Identifying HPA-1a-negative donors requires simple and reliable typing methods. Most existing techniques use polyclonal antibodies, are time consuming and involve platelet isolation. We have used a horseradish peroxidase (HRP)-conjugated recombinant IgG1 anti-HPA-1a (CAMTRAN007) to develop a rapid and reliable enzyme-linked immunosorbent assay (ELISA), which eliminates sample preparation and reduces the incubation and wash steps associated with traditional sandwich ELISAs. The assay uses simultaneous incubation of the monoclonal antibody RFGP56 to capture GPIIbIIIa from whole blood and the recombinant IgG1 antibody to detect captured HPA-1a antigen. It allows 96 samples to be typed in less than 1 h and can be used on stored samples. Initial testing of 85 samples of known HPA-1a genotype demonstrated that HPA-1a-negative samples had OD values of < 0.266, whereas HPA-1a-positive samples had OD values of > 0.6. Testing of 1862 random donor samples in two blood centres confirmed these OD cut-off values and identified 45 HPA-1a-negative samples (2.4%), all except one giving OD values of < 0.2. The remaining HPA-1a-negative sample had an OD value of 0.303. The HPA-1a status on all the negative samples and an equivalent number of randomly selected positive samples was confirmed by flow cytometry and polymerase chain reaction with sequence-specific primers (PCR- SSP).

Antigens, Human Platelet↗

Detection of Gov system antibodies by MAIPA reveals an immunogenicity similar to the HPA-5 alloantigens.

The glycosylphosphatidylinositol-linked platelet protein CD109 carries the biallelic alloantigen system Gov. There is limited information on the incidence of Gov alloantibodies in neonatal alloimmune thrombocytopenia (NAITP), post-transfusion purpura (PTP) and platelet refractoriness. We adapted the monoclonal antibody-specific immobilization of platelet antigens (MAIPA) assay to the detection of Gov antibodies and determined their incidence in 605 archived samples (112 with HPA antibodies) referred for the aforementioned conditions. Here, we show that CD109 expression was reduced upon platelet storage in saline or by cryopreservation, but was stable when stored as whole blood or therapeutic platelet concentrate. Fourteen of the 605 samples contained Gov alloantibodies (anti-Gova, n = 10; anti-Govb, n = 4), with the majority in platelet refractoriness (n = 9) and, of the remaining five, four in NAITP and one in PTP. In seven cases, no other HPA antibodies were detected, three being NAITP cases. The incidence of Gov antibodies was significantly lower than HPA-1 system antibodies (n = 87), but equalled the number of HPA-5 system antibodies (n = 14) and outnumbered HPA-2 and -3 system antibodies (10 altogether).

Alleles↗

Effect of hip prostheses on radiotherapy dose.

A small but growing proportion of patients requiring radiotherapy for prostate cancer have one or two hip prostheses which may shadow the target and affect the dose distribution. Approximately 10 such patients are treated at the Illawarra Cancer Care Centre per year. Hence a study was undertaken to examine the accuracy of various treatment methods that involve some of the treatment fields travelling through the prosthesis. A fixed-field measurement showed a dose reduction of 52% in the shadow of the prosthesis. A Monte Carlo simulation confirmed an increase in dose on the distal surface of the prosthesis of 35%. Of more clinical relevance, however, is the dose distribution due to the overall combined field treatment. Using a power law correction benchmarked against thermoluminescent dosimeters and Gafchromic film, three different beam set-ups for patient treatment were planned and the dose variation analysed. A four-field brick technique gave a dose variation across the target volume of +/- 15% whereas a dual arc technique gave a dose variation of only +/- 5%. A four-field oblique technique gave a dose variation of only +/- 2% across the target volume but the oblique field technique included extra dose to the rectum.

Biocompatible Materials↗

Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method.

Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC Pinnacle, 3D planning system. Up to 5% variations between doses calculated at the centre and near the edge of the 2 cm phantom slice positioned at the beam central axis were seen, due to the composition of each phantom slice. Validation of dose was performed with LiF thermoluminescent dosimeters (TLDs) and X-Omat V radiographic film. Both dosimetry media produced dose results which agreed closely with calculated results nearest their physical positioning in the phantom. The collapsed cone convolution method accurately calculates dose within inhomogeneous lung regions at 6 MV and 10 MV x-ray energy.

Algorithms↗

Monoclonal antibodies against platelet membrane glycoproteins IIb/IIIa and Ibalpha inhibit platelet dependent thrombin generation by different mechanisms.

The antithrombotic effect of antiplatelet agents is principally due to their anti-aggregatory action, but these agents may also interfere with coagulation. We have investigated the effect of monoclonal antibodies (MAb) to platelet membrane glycoproteins (GP) IIb/IIIa and Ibalpha on thrombin generation. Antibodies to platelet membrane glycoprotein IIb/IIIa (RFGP56 and c7E3) were shown to inhibit platelet-mediated thrombin generation stimulated by both intrinsic and extrinsic methods. An antibody to GP Ibalpha (RFGP37) also inhibited thrombin generation in these systems. FITC-annexin V was used to determine the effect of these antibodies on the exposure of procoagulant phospholipids on the platelet membrane, and it was found that the anti-IIb/IIIa antibodies reduced this, whereas the anti-Ibalpha antibody caused an increase. We conclude that our monoclonal antibodies against platelet membrane glycoproteins IIb/IIIa and Ibalpha inhibit platelet dependent thrombin generation by different mechanisms.

Animals↗

Radiotherapy dose compensation for lung patients.

The purpose of the present paper is to provide a more homogeneous dose distribution in the target volume from compensated anterior and posterior fields while the healthy lung is spared by de-weighting the lateral fields. A compensation computation which used linear iterations to compute the most homogeneous dose distribution across the target volume was applied to produce optimum compensator designs. The equivalent tissue-air ratio (E-TAR) inhomogeneity correction was applied for the computations using a GE target series II planning computer. The compensators designed were tested for accuracy in a modified water/lung phantom using a scanning diode and an anthropomorphic phantom using thermoluminescent dosimeters. A comparison has been made between the compensated and uncompensated plans for the first nine patients who we have treated with this technique. The dose profiles produced by the computation agreed with the prediction of the computed isodose plans to within +/- 2% at the target depth. The thermoluminescent dosimeter (TLD)-measured results in the anthropomorphic phantom agreed with the planning computer within +/- 3%. A comparison of nine compensated plans of radiotherapy patients for large-volume targets in the lung region showed a maximum variation in the target to be 19% uncompensated versus 10% compensated. By providing compensated treatment fields from anterior and posterior treatment portals, a homogeneous dose that conforms well to the target volume is provided. As an added bonus, this enables the lateral lung fields to be significantly de-weighted and the healthy lung is spared considerable dose.

Humans↗

Rapid phenotyping of HPA-1a using either diabody-based hemagglutination or recombinant IgG1-based assays.

BACKGROUND: The HPA-1 system is carried on the beta3 integrin. HPA-1a (Zw(a), Pl(A1)) is immunogenic in an HPA-1b homozygote (HPA-1b1b). In pregnancy, 1 of 365 women forms anti-HPA-1a, which causes severe thrombocytopenia in 1 in 1100 neonates. Identification of women at risk of forming anti-HPA-1a and the screening of donors to obtain HPA-1a-negative platelets for therapy need reliable, low-cost, automated assays. STUDY DESIGN AND METHODS: A diabody with dual specificity for HPA-1a x D and an IgG1 anti-HPA-1a have been constructed by the use of the genes encoding the first anti-HPA-1a fragment. With these reagents, two complementary HPA-1a phenotyping assays have been developed. RESULTS: This diabody was used in a simple hemagglutination technique to perform HPA-1a phenotyping on soluble glycoprotein IIb/IIIa from EDTA plasma samples. Over 1000 unselected donors have been correctly HPA-1a-phenotyped by use of the diabody. The human recombinant IgG1 anti-HPA-1a was produced in a rat myeloma cell line and was fluorescein labeled for use in a whole-blood flow cytometric HPA-1a phenotyping assay. This IgG1 anti-HPA-1a shows a clear differential between HPA-1a-positive and HPA-1a-negative platelets at nM antibody concentrations. CONCLUSIONS: The two recombinant reagents described are highly suitable for screening and confirmatory HPA-1a phenotyping. They permit rapid determination of the HPA-1a phenotype and are amenable to automation.

Antigens, CD↗

Accounting for treatment delays when treating highly proliferative tumours.

This study was undertaken to investigate the possibility of increasing the dose per fraction or increasing the number of fractions to account for treatment delays occurring during radiotherapy treatments for highly proliferative tumours. The linear quadratic model with time was used to determine the difference in biological effective dose (BED) for the original schedule and the schedule including a treatment delay. Tables of extra fractions and extra dose per fraction required to account for a number of possible delays have been determined. It has been shown that for tumours with very short potential doubling times it is best to deliver the extra dose as an increase in dose per fraction rather than an increase in the number of fractions, while for tumours with moderately short potential doubling times (above 7 days) the reverse is true. The equivalent uninterrupted schedules, which would have delivered the same effects to the tumour, have also been determined.

Cell Division↗

Perturbation of radiotherapy beams by radiographic film: measurements and Monte Carlo simulations.

Radiographic film is an established practical tool used in the measurement of the dose distribution for radiotherapy purposes. The accuracy and reproducibility of film optical density as an indicator of dose has been associated with several factors including photon energy, processing conditions and film plane orientation. Few studies have investigated the factors causing variability in film dosimetry, due to the difficulty of separating the individual contributions. The effect that a sheet of radiographic film in a water phantom has on its response to a 6 MV photon and a cobalt-60 teletherapy beam, when orientated perpendicular and parallel to the beam central axis, is reported. Monte Carlo generated spectra were used to calculate collision kerma (Kcoll) for water and film elements. Measured and calculated results indicate a potential over-response at 25 cm depth of the order of 14 +/- 2.4% and 18 +/- 6.0% respectively for 6 MV photons and 15 +/- 3.4% and 32 +/- 4.5% respectively for a cobalt beam. For film exposed parallel as compared to perpendicular to the central axis of the beam, the calculated results suggest an explanation in terms of the predominantly forward directed secondary electrons for the measured difference in film response at depth. It is proposed that the difference in response of the parallel as compared to perpendicular exposed film be due to the predominantly 'upstream' photon interactions giving rise to energy deposition in film. The simulations indicate that the variation with depth of relative energy imparted in film and water elements correlates with the observed variation in film response with depth.

Energy Transfer↗

Standard effective doses for proliferative tumours.

This study was undertaken to investigate the treatment schedules used clinically for highly proliferative tumours, particularly with reference to the effects of fraction size, fraction number and treatment duration. The linear quadratic model (with time component) is used here to compare non-standard treatment regimens (e.g. accelerated and hyperfractionated schedules), currently the focus of randomized trials, with each other and some common 'standard regimens'. To ensure easy interpretation of results, two parameters known as proliferative standard effective dose one (PSED1) and proliferative standard effective dose two (PSED2) have been calculated for each regimen. Graphs of PSED1 and PSED2 versus potential doubling time (Tp) have been generated for a range of fractionation regimens which are currently under trial in various randomized studies. From these graphs it can be seen that the highly accelerated schedules (such as CHART) only show advantages for tumours with very short potential doubling times. Calculations for most of the schedules considered showed at least equivalent tumour control expected for the trial schedule compared with the control arm used and these values agree quite well with clinical results. These calculations are in good agreement with clinical results available at present. The greater the PSED1 or PSED2 for the schedule considered the greater the tumour control, which can be expected. However, as has been seen with clinical trials, this higher cell kill also results in higher acute effects which have proved too great for some accelerated schedules to continue.

Cell Division↗

HPA genotyping by PCR-SSP: report of 4 exercises.

BACKGROUND AND OBJECTIVES: Polymerase chain reaction with sequence specific primers (PCR-SSP) is widely used for the determination of the alleles encoding the human platelet antigens (HPA)-1 to 5. In order to evaluate and improve performance with this technique, four exercises were organised during 1996-1998. MATERIALS AND METHODS: Coded DNA samples were distributed from the National Institute for Biological Standards and Control (NIBSC) as follows: exercise one, 18 samples; two, 12 samples; three, 6 samples, and four, 4 samples. RESULTS: Performance improved over the four exercises following the adoption of a consensus protocol and the re-design of one primer. The percentage of incorrect results in each exercise was as follows: exercise one, 9%; two 3.2%, three, 0.8%, and four, 0.3%. CONCLUSION: The modified PCR-SSP protocol is a reliable method for genotyping HPA-1 to 5 in reference laboratories. DNA-based HPA genotyping has an important role in platelet immunology and further exercises will be included in the bi-annual platelet immunology exercises organised by NIBSC.

Antigens, Human Platelet↗

Activation during preparation of therapeutic platelets affects deterioration during storage: a comparative flow cytometric study of different production methods.

Three different separation methods, all using centrifugation, are routinely used to prepare therapeutic platelet concentrates from human donor blood. Platelet concentrates derived from platelet-rich plasma (PRP-PC), buffy coat (BC-PC) and apheresis (AP-PC) were investigated at the end of production, and over an 8 d storage period. Change in platelet surface markers were measured by flow cytometry, using fluorescein-conjugated antibodies to fibrinogen, P-selectin (CD62P), GPIIb-IIIa (CD41), GPIb alpha (CD42b) and GPV (CD42d), and fluorescein-conjugated Annexin V was used to measure expression of anionic phospholipid. All concentrates showed some changes during preparation but PRP-PC underwent the greatest changes with significantly higher levels of P-selectin (P<0.001) and bound Annexin V (P=0.001) than AP-PC or BC-PC, and lower levels of GPIb alpha (P=0.002) and GPV (P<0.001). These changes were attributable to component separation rather than venesection. These markers all continued to change on storage with a strong positive correlation between the changes seen during production and those after 5 d storage. PRP-PC continued to show the greatest changes whereas BC-PC showed the least. Fibrinogen was bound to 40-50% of platelets in all preparations and this did not alter significantly on storage whereas total expression of GPIIb-IIIa remained unchanged throughout. There was no evidence that the platelet surface changes were thrombin-mediated and leucocyte depletion of BP-PC by filtration had no effect on the changes. It is proposed that the deterioration of platelet concentrates during storage may be related to activation occurring during preparation. 'Whole blood' flow cytometry using a panel of fluorescein-labelled reagents provides an informative method for evaluating platelet concentrates.

Annexin A5↗

Interlaboratory variation in the detection of clinically significant alloantibodies against human platelet alloantigens.

This report describes the results of eight workshop exercises which were designed to test the proficiency of laboratories in the detection of antibodies to human platelet antigens (HPA). Detection of the most clinically significant alloantibody, anti-HPA-1a, is adequate. However, despite improvements in consistency of test results between laboratories over the last 3 years, there is still a high probability that clinically significant antibodies against other HPA alloantigens will not be detected.

Antigens, Human Platelet↗

HPA genotyping by PCR sequence-specific priming (PCR-SSP): a streamlined method for rapid routine investigations.

We describe a streamlined method for the simultaneous identification of alleles of the human platelet antigens (HPA) 1-5. The method employs the polymerase chain reaction with sequence specific primers (PCR-SSP). Although PCR-SSP has been applied to HPA genotyping, all methods previously described have required different reaction mixes and PCR conditions. We have designed a set of sequence-specific primers for HPA 1-5 which react optimally under identical reaction and PCR conditions. Comparative testing with reference samples gave 100% concordance. The advantages of this method include speed; accuracy; smaller sample requirements and no reliance on human typing sera or platelet integrity. The method also has the potential to be applied to amniotic fluid. Simplified DNA techniques will lead to more extensive and proficient platelet antigen typing. This will facilitate accurate laboratory diagnosis of alloimmune thrombocytopenia and the provision of HPA-matched blood products.

Alleles↗

The validity of using radiographic film for radiotherapy dosimetry.

Radiographic film is routinely used to obtain dosimetric information about therapy treatment beams. One source of inaccuracy is the variability of the chemical processing of the radiographic film. Several processors, film types and two sources (light and x-rays) were used to investigate the reproducibility of film processing for valid film dosimetry. Particular attention is paid to films commonly used in radiation therapy. The results suggest that for this series of film, given the same exposure, the variability in processing may result in an error of +/- 3.3% in optical density, which would lead to an error of +/- 4.4% in indicated dose. This level of inaccuracy is typical for both point and relative dose estimates. These results indicate that film should not be used as a point or relative dosimeter, unless the combination of film type, exposure, processing and reading have been specifically validated.

Equipment Design↗

Multicentre dosimetry study of mantle treatment in Australia and New Zealand.

PURPOSE: To determine the difference between expected and measured dose for patients prescribed a mantle treatment for Hodgkin's disease and estimate the range of dose at critical sites and between different treatment centres. METHODS AND MATERIALS: Twenty three radiotherapy centres were surveyed with regard to the accuracy of dose delivery to a custom-built upper-torso phantom. Thermoluminescent dosimeters were used to monitor the delivered dose at sites such as mid-plane, spinal cord, neck, axilla and lung. RESULTS: The intended dose to the phantom at each centre was 1 Gy to central axis mid-plane. Of the centres surveyed, the median measured dose to this region was 0.96 Gy with a minimum of 0.92 and a maximum of 1.00 Gy. Median dose to the axilla region was low (0.90 Gy) whereas median dose to the blocked lung and neck region were higher than expected, 0.18 Gy and 1.25 Gy, respectively. The 95% confidence interval on the reported relative dose using the 4000 thermoluminescence dosimetry readings in this study was +/- 1.5% CONCLUSION: In this controlled experiment, using conventional methods to calculate dose, there was a surprising variability in the dose delivered at the central axis mid-plane position. This was traced to lack of uniformity in the use of equivalent squares to calculate the output factor. The measured doses to axilla and lung are explained by photon and electron scattering effects. Centres, where dose compensation was included, had a superior dose homogeneity in the neck. The off-axis dose calculations depend on computer planning software but the magnitude of these differences is secondary to that of central axis mid-point dose differences. Improved consistency of dose calculation techniques between centres would enable more reliable dose response evaluation from multicentre clinical studies of Hodgkin's disease.

Australia↗

Antenatal screening for fetal alloimmune thrombocytopenia: the results of a pilot study.

Feto-maternal incompatibility for the human platelet antigen HPA-1a is an important cause of severe fetal thrombocytopenia. The incidence is 1 in 1000-2000 pregnancies, which is more common than other conditions for which screening is presently carried out. Antenatal diagnosis and management are now available, but only for subsequent siblings following diagnosis of a previously affected infant. This study describes a pilot prospective screening programme for the antenatal detection of fetomaternal alloimmune thrombocytopenia (FMAIT) due to HPA-1a incompatibility. 3473 women were typed for HPA-1a using a method designed for large-scale typing. 71 women found to be HPA-1a negative were further tested for HLA-DR52a as a risk factor for alloimmunization. All women were monitored for the development of anti-HPA-1a throughout pregnancy and a cord full blood count was taken at delivery. Two affected pregnancies were found and treated: a singleton pregnancy was treated antenatally and a twin pregnancy after delivery. The study showed that screening for FMAIT could be established within the pre-existing antenatal red cell serology programme. It was concluded that screening should be based on platelet typing and offered regardless of parity. Further stratification, combining DR52a typing and HPA-1a antibody screening, although focusing on the group of women at greater risk, may not identify all affected pregnancies. Confirmation of the diagnosis and severity of FMAIT continues to depend on fetal blood sampling during pregnancy or cord blood samples after birth.

Adult↗