Search PubMed⌕ Search

Biomedical subjects

P Marquet

Publications and source records attributed to P Marquet.

At least 19 recordsLinked to original sources

Sensitive and specific multiresidue methods for the determination of pesticides of various classes in clinical and forensic toxicology.

Original and sensitive multiresidue methods are presented for the detection and quantitation, in human biological matrices, of 61 pesticides of toxicological significance in human. These methods involved rapid solid-phase extraction using new polymeric support (HLB and MCX) OASIS cartridges. Gas chromatography-mass spectrometry (GC-MS) was used for volatile (organophosphate, organochlorine, phtalimide, uracil) pesticides and liquid chromatography-ionspray-mass spectrometry (LC-MS) for thermolabile and polar pesticides (carbamates, benzimidazoles). Acquisition was performed in the selected ion monitoring (SIM) mode. Extraction recovery varied owing to the nature of pesticides, but was satisfactory for all. Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 2.5 to 20 and from 5 to 50ng/ml. An excellent linearity was observed from LOQs up to 1000ng/ml for all the pesticides studied. The proposed procedures yielded reproducible results with good inter-assay accuracy and precision. A few cases of intoxication are presented to demonstrate the diagnostic interest of these methods: in two cases were determined lethal concentrations of endosulfan and carbofuran; in four other cases, the procedures helped diagnose intoxication with, respectively, parathion-ethyl, the association of bromacil and strychnine, bifenthrin and aldicarb.

Adult↗

Determination of N-acetylation phenotype using caffeine as a metabolic probe and high-performance liquid chromatography with either ultraviolet detection or electrospray mass spectrometry.

A rapid, sensitive method using liquid chromatography-electrospray mass spectrometry (LC-ES-MS) was developed and evaluated for the simultaneous quantitative determination of caffeine metabolites 1U, 1X and AAMU in human urine. This method involved a simple dilution of urine samples. The chromatographic separation was achieved on a C18 reversed-phase column using a gradient of acetonitrile in 2 mM, pH 3.0 ammonium formate as mobile phase. After ionisation in an electrospray source, mass spectrometric detection was performed in the negative ion, selected ion monitoring mode. This method yielded acceptable accuracy and precision within the range 0.25-50 microg/ml. This analytical method was applied to investigate the N-acetylator phenotype of HIV-infected patients and compared with high-performance liquid chromatography with UV detection. Its specificity was better, which appeared to be absolutely necessary to prevent errors in metabolic ratios and phenotype interpretation.

Acetylation↗

Multiresidue determination method for organophosphorus pesticides in serum and whole blood by gas chromatography-mass-selective detection.

This paper describes a rapid, specific and sensitive method for the determination of 29 organophosphorus pesticides in blood and serum, involving a rapid solid-phase extraction procedure using Oasis HLB cartridges and gas chromatography coupled to mass-selective detection. The ionization was performed by electron Impact and acquisition in the single ion monitoring mode followed three specific ions per analyte. Extraction recoveries were satisfactory and ranged between 40 and 108% in blood and serum. Limits of detection ranged from 5 to 25 ng/ml and limits of quantitation (LOQs) ranged from 10 to 50 ng/ml, in blood and serum. An excellent linearity was observed from these LOQs up to 1000 ng/ml. Intra- and inter-assay precision and accuracy were satisfactory for most of the pesticides analyzed.

Gas Chromatography-Mass Spectrometry↗

Sensitive determination of vinorelbine and its metabolites in human serum using liquid chromatography-electrospray mass spectrometry.

A liquid chromatography-electrospray mass spectrometry method was developed for the quantitation of vinorelbine (VNB) and two metabolites, vinorelbine N-oxide (VNO) and deacetyl vinorelbine (DAV) in human serum. The limits of quantitation (LOQ) reached 0.5 ng/ml for both VNB and VNO and 1 ng/ml for DAV. The method was proved linear in the range of LOQs up to 1000 ng/ml, and extraction recovery was 80% on average for the three compounds. It was applied to the pharmacokinetic monitoring of vinorelbine and, for the first time, to the detection of VNO in the serum of patients suffering from non-small-cell lung cancer.

Antineoplastic Agents, Phytogenic↗

Application of a gamma model of absorption to oral cyclosporin.

BACKGROUND: Some drugs, such as cyclosporin, exhibit flat and delayed absorption profiles, with a correlation between the delay and the peak width. Such profiles can be described by an absorption model in which the absorption rate is derived from a gamma distribution (of which the classical first-order absorption model is a special case). OBJECTIVE: To develop a model for the pharmacokinetics of extravascular administration of cyclosporin and apply it to a study of the pharmacokinetics of cyclosporin microemulsion in stable renal transplant recipients. PATIENTS AND PARTICIPANTS: 21 renal transplant patients receiving oral cyclosporin microemulsion 75 to 175 mg twice daily. METHODS: The equation of the plasma concentration-time curve after oral administration was expressed as a convolution product between the absorption rate and a multi-exponential impulse response. The convolution integral was computed analytically and expressed in terms of the incomplete gamma function. Cyclosporin was assayed by liquid chromatography/mass spectrophotometry. The model was fitted by nonlinear regression, using a specially developed program. RESULTS: The gamma model yielded a good fit in all of the 21 patients studied. Attempts to fit the same data by a classical exponential with lag-time model failed in most patients. CONCLUSIONS: This model could simplify the Bayesian monitoring of cyclosporin therapy.

Area Under Curve↗

High-performance liquid chromatographic determination of tianeptine in plasma applied to pharmacokinetic studies.

An improved analytical method for the quantitative measurement of tianeptine and its main metabolite MC5 in human plasma was designed. Extraction involved ion-paired liquid-liquid extraction of the compounds from 1.0 ml of human plasma adjusted to pH 7.0. HPLC separation was performed using a Nucleosil C18, 5 microm column (150x4.6 mm I.D.) and a mixture of acetonitrile and pH 3, 2.7 g l(-1) solution of sodium heptanesulfonate in distilled water (40:60, v/v) as mobile phase. UV detection was performed using a diode array detector in the 200-400 nm passband, and quantification of the analytes was made at 220 nm. For both tianeptine and MC5 metabolite, the limit of quantitation was 5 microg l(-1) and the calibration curves were linear from 5 to 500 microg l(-1). Intra- and inter-assay precision and accuracy fulfilled the international requirements. The recovery of tianeptine and its metabolite from plasma was, respectively, 71.5 and 74.3% at 20 microg l(-1), 71.2 and 70.8% at 400 microg l(-1). The selectivity of the method was checked by verifying the absence of chromatographic interference from pure solutions of the most commonly associated therapeutic drugs. This method, validated according to the criteria established by the Journal of Chromatography B, was applied to the determination of tianeptine and MC5-metabolite in human plasma in pharmacokinetic studies.

Antidepressive Agents, Tricyclic↗

Methods for the determination of seven selective serotonin reuptake inhibitors and three active metabolites in human serum using high-performance liquid chromatography and gas chromatography.

This paper describes a set of simple and sensitive multiresidue methods for the determination of the specific serotonin reuptake inhibitors (SSRIs) used as antidepressant drugs, and some of their respective active metabolites in human serum. It involves liquid-liquid extraction procedures followed by gas chromatography coupled to nitrogen phosphorus detection or isocratic reversed-phase high-performance liquid chromatography combined with fluorescence detection (HPLC-FL), depending on the analytes. Extraction recoveries were between 71 and 96% for the eight SSRIs and their metabolites analysed by GC and between 41 and 77% for the two of them analysed by HPLC. Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 2.5 to 5 microg/l and from 10 to 20 microg/l. Intra-assay and inter-assay precision was studied at three and four concentration levels, respectively, and was less than 19% for all compounds. Accuracy was also satisfactory for all. An excellent linearity was observed from the LOQs up to 1000 microg/l for milnacipram and paroxetine and from each LOQ up to 400 mg/l for the other compounds. The performance of the methods described thus allows the therapeutic drug monitoring of the currently commercialised SSRIs.

Antidepressive Agents, Second-Generation↗

Simultaneous determination of four anthracyclines and three metabolites in human serum by liquid chromatography-electrospray mass spectrometry.

A sensitive and very specific method, using liquid chromatography-electrospray mass spectrometry (LC-ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform-2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)-acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 microm (150 x 1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)-acetonitrile (70:30, v/v) as mobile phase, delivered at 50 microl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r > or = 0.992) and 200 ng/ml for the active metabolites (r > or = 0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.

Antibiotics, Antineoplastic↗

A quantitative analysis of L-glutamate-regulated Na+ dynamics in mouse cortical astrocytes: implications for cellular bioenergetics.

The mode of Na+ entry and the dynamics of intracellular Na+ concentration ([Na+]i) changes consecutive to the application of the neurotransmitter glutamate were investigated in mouse cortical astrocytes in primary culture by video fluorescence microscopy. An elevation of [Na+]i was evoked by glutamate, whose amplitude and initial rate were concentration dependent. The glutamate-evoked Na+ increase was primarily due to Na+-glutamate cotransport, as inhibition of non-NMDA ionotropic receptors by 6-cyano-7-nitroquinoxiline-2,3-dione (CNQX) only weakly diminished the response and D-aspartate, a substrate of the glutamate transporter, produced [Na+]i elevations similar to those evoked by glutamate. Non-NMDA receptor activation could nevertheless be demonstrated by preventing receptor desensitization using cyclothiazide. Thus, in normal conditions non-NMDA receptors do not contribute significantly to the glutamate-evoked Na+ response. The rate of Na+ influx decreased during glutamate application, with kinetics that correlate well with the increase in [Na+]i and which depend on the extracellular concentration of glutamate. A tight coupling between Na+ entry and Na+/K+ ATPase activity was revealed by the massive [Na+]i increase evoked by glutamate when pump activity was inhibited by ouabain. During prolonged glutamate application, [Na+]i remains elevated at a new steady-state where Na+ influx through the transporter matches Na+ extrusion through the Na+/K+ ATPase. A mathematical model of the dynamics of [Na+]i homeostasis is presented which precisely defines the critical role of Na+ influx kinetics in the establishment of the elevated steady state and its consequences on the cellular bioenergetics. Indeed, extracellular glutamate concentrations of 10 microM already markedly increase the energetic demands of the astrocytes.

6-Cyano-7-nitroquinoxaline-2,3-dione↗

Adaptive control methods for the dose individualisation of anticancer agents.

Numerous studies have found a clear relationship between systemic exposure and the toxicity or (more rarely) the efficacy of anticancer agents. Moreover, the clearance of most of these drugs differs widely between patients. These findings, combined with the narrow therapeutic index of anticancer drugs, suggest that patient outcome would be improved if doses were individualised to achieve a target systemic exposure. Bayesian maximum a posteriori probability (MAP) forecasting is an efficient and robust method for the optimisation of drug therapy, but its use for anticancer drugs is not yet extensive. The aim of this paper is to review the application of population pharmacokinetics and MAP to anticancer drugs and to evaluate whether and when MAP Bayesian estimation improves the clinical benefit of anticancer chemotherapy. For each drug, the relationships between pharmacokinetic variables [e.g. plasma concentration or the area under the concentration-time curve] and pharmacodynamic effects are described. Secondly, the methodologies employed are considered and, finally, the results are analysed in terms of predictive performance as well as, where possible, the impact on clinical end-points. Some studies were retrospective and intended only to evaluate individual pharmacokinetic parameter values using very few blood samples. Among the prospective trials, a few studied the pharmacokinetic/pharmacodynamic relationships which provided the basis for routine pharmacokinetic monitoring. Others were performed in clinical context where MAP Bayesian estimation was used to determine maximum tolerated systemic exposure (e.g. for carboplatin, topotecan, teniposide) or for pharmacokinetic monitoring (e.g. for methotrexate or platinum compounds). Indeed, its flexibility in blood sampling times makes this technique much more applicable than other limited sampling strategies. These examples demonstrate that individual dose adjustment helps manage toxicity. The performance of pharmacokinetic monitoring is linked to the methodology used at each step of its design and application. Moreover, a limitation to the use of pharmacokinetic monitoring for certain anticancer drugs has been the difficulty in obtaining pharmacokinetic or pharmacodynamic data. Recent progress in analytical methods, as well as the development of noninvasive methods (such as positron emission tomography) for evaluating the effects of chemotherapy, will help to define pharmacokinetic-pharmacodynamic relationships. Bayesian estimation is the strategy of choice for performing pharmacokinetic studies, as well as ensuring that a given patient benefits from the desired systemic exposure. Together, these methods could contribute to improving cancer chemotherapy in terms of patient outcome and survival.

Animals↗

Fatal intoxication following self-administration of a massive dose of buprenorphine.

Several drug packages, including Subutex (high-dose buprenorphine, as sublingual tablets) boxes, were found near the corpse of a 25-year-old male drug addict, who apparently had committed suicide. The autopsy revealed a fatal respiratory depression. The toxicological investigations concluded that death resulted from massive burpienorphine intoxication. The determination of buprenorphine (BU) and norbuprenorphine (NBU) in all biological specimens was performed by liquid chromatography-electrospray mass spectrometry (LC-ES-MS) after hydrolysis (for solid tissues), deproteinization of the matrices, and solid-phase extraction of the compounds. Exceptionally high concentrations of BU and NBU were found in blood (3.3 and 0.4 mg/L, respectively), urine (3.4 and 0.6 mg/L), bile (2035 and 536 mg/L and brain (6.4 a nd 3.9 microg/g). The high concentration of BU (899 mg/L) and the absence of NBU in gastric liquid suggested oral intake. High concentrations of amino-7-flunitra/epam, the main metabolite of flunitra/epam, were also found in blood, urine and gastric liquid. This benzodiazepine may have been a co-factor in the toxic effects of BU.

Adult↗

A non-fatal case of intoxication with foxglove, documented by means of liquid chromatography-electrospray-mass spectrometry.

The non-fatal self-poisoning of a 36-year-old female patient, who ingested a concoction of foxglove (Digitalis Purpurea), is presented. On the admission, initial symptoms were nausea and vomiting, abdominal pain, and cardiovascular shock with sinus bradycardia. Blood and urine were assayed for 17 cardiotonic hetorosides, using a highly specific LC-MS procedure. Serum and urine specimens were collected over five days and analyzed by liquid chromatography-electrospray-mass spectrometry (LC-ES-MS). This accurate procedure allowed the determination of the digitalis glycosides and their metabolites in serum and urine. The serum concentrations of digitalis glycosides were maximum on the first day (gitoxin 13.1 ng/mL, digitoxin 112.6 ng/mL, digitoxigenin 3.3 ng/mL, and digitoxigenin mono-digitoxoside 8.9 ng/mL) and decreased over five days. We observed a peak gitaloxin level (112.6 ng/mL) on the fifth day only. After administration of atropine as well as dimeticone, alginic acid, and metoclopramide, health status improved. The peak urine concentrations were reached at hour 30 and were respectively 91.3 and 69.9 ng/mL for gitaloxin and digitoxin, while those of digitoxigenin, digitoxigenin mono-digoxoside and gitoxin were lower (respectively 0.7, 1, and 5.6 ng/mL). The patient was discharged on the fifth day when there were no residual symptoms.

Adult↗

Sensitive determination of irinotecan (CPT-11) and its active metabolite SN-38 in human serum using liquid chromatography-electrospray mass spectrometry.

A couple of sensitive and accurate liquid chromatography-electrospray mass spectrometry (LC- S-MS) methods for the determination of the total forms of irinotecan and its active metabolite SN-38 in human serum, using the same chromatographic and detection conditions, is presented. Both used camptothecin as internal standard (I.S.). The sample pretreatment for irinotecan involved a simple protein precipitation with acetonitrile, whereas a liquid-liquid extraction was necessary for SN-38. A Symmetry C18, 3.5 microm (150 x 1 mm I.D.) reversed-phase column was used for the chromatographic separation, together with a gradient elution of acetonitrile in 5 mM ammonium formate buffer (pH 3) as mobile phase. After ionisation in the pneumatically-assisted electrospray source and in-source collision induced dissociation, acquisition was performed in the selected ion monitoring mode. Recoveries were 69 and 47% on average, detection limits 2.5 and 0.25 ng/ml and quantitation limits 10 and 0.5 ng/ml for irinotecan and SN-38, respectively. Reproducibility was good and the method was linear from limits of quantitation up to 10,000 ng/ml for irinotecan, and up to 100 ng/ml for SN-38. This sensitive and highly specific method is suitable both for pharmacokinetic studies and routine therapeutic drug monitoring.

Acetonitriles↗

Sensitive and specific determination of midazolam and 1-hydroxymidazolam in human serum by liquid chromatography-electrospray mass spectrometry.

A liquid chromatographic-mass spectrometric technique was designed for the determination of the anaesthetic benzodiazepine midazolam (MID) and its active metabolite 1-hydroxymidazolam (1-OHM), with the aim of conducting pharmacokinetic/pharmacodynamic studies. MID and 1-OHM were extracted from alkalinised (pH 9.5) spiked and clinical serum samples using a single step, liquid-liquid extraction procedure with diethyl ether-2-propanol (98:2, v/v). The chromatographic separation was performed on a Nucleosil C18, 5 microm (150x1 mm I.D.) column, using a gradient of acetonitrile in 5 mM ammonium formate, pH 3.0 as the mobile phase, delivered at a flow-rate of 50 microl/min. The compounds were ionised in the ionspray source of an atmospheric pressure mass spectrometer, fragmented by in-source collisions and the pseudomolecular and fragment ions detected in the selected ion monitoring mode. The recovery was between 79 and 87% for MID, between 83 and 87% for 1-OHM and 81.5% for methylclonazepam. The limit of detection was 0.2 microg/l for MID and 0.5 microg/l for 1-OHM, the limit of quantitation (LOQ) was 0.5 microg/l for both. Linearity was verified from these LOQs up to 2000 microg/l and the method was found accurate and precise over this range. It was successfully applied to a preliminary study to establish the concentration versus time curve of MID and 1-OHM in a patient administered midazolam by continuous infusion.

Anesthetics, Intravenous↗

Liquid chromatography-mass spectrometry: potential in forensic and clinical toxicology.

A relatively limited number of papers concerning applications of liquid chromatography-mass spectrometry (LC-MS) to forensic or clinical toxicology, or analytical methods directly applicable to these topics have been published so far, but their number have greatly increased in the past two years, probably due to technical improvements and to a decrease in the price of such instruments. After a brief presentation and exemplary applications of the interfaces and/or sources proposed in the past for coupling HPLC to mass spectrometry (direct liquid inlet, moving belt, fast atom bombardment and thermospray interfaces), this paper describes electrospray-type and atmospheric pressure chemical ionisation interfaces and their most recent applications in forensic or clinical toxicology. In a third section, the different LC-MS solutions proposed for typical applications in human toxicology, such as the determination of morphine metabolites, LSD and its metabolites and corticosteroids in blood or urine, are reviewed in detail in order to highlight the strengths and weaknesses of each ionisation device and/or analytical method. The last section envisages the new analytical fields opened up by LC-MS in toxicology, regarding mainly peptides, proteins and large molecules, as well as the possible use of LC-MS as a complement to GC-MS for "general unknown" screenings; it also deals with the perspectives concerning technical improvements in ionisation interfaces/sources or mass spectrometers, as well as in sample preparation and liquid chromatography techniques applied to this type of coupling. Though LC-MS is still a relatively new technique in toxicology, on taking into consideration its success so far and owing to the simplification of instruments and concept handling thanks to user-friendly software, it is the authors' opinion that it will become a major success in analytical toxicology in the next few years.

Atmospheric Pressure↗

In vitro and in vivo study of the antithyroid side effects of trimeprazine.

Trimeprazine (TMP), a phenothiazine used as antipsychotic drug, was previously shown to induce a decrease in thyroid hormone serum levels in rats. Different mechanisms might be involved, mainly (i) a central mechanism, involving a reduction of thyroid-stimulating hormone (TSH) secretion; (ii) a peripheral mechanism, acting upon the synthesis of thyroid hormones, by inhibition of thyroperoxidase (TPO) or trapping of molecular iodine present in the thyroid gland. These different hypotheses were investigated in the present study, using in vitro and in vivo experiments. In vitro studies concerned TMP and its three main metabolites: trimeprazine sulphoxide (TSO), N-desmethyl trimeprazine (NDT), and 3-hydroxy-trimeprazine (3-OHT). TMP and TSO expressed a high affinity for iodine in vitro, contrary to NDT, which did not complex iodine. Only 3-OHT inhibited TPO in vitro. Administration of 5 mg/kg TMP ip twice daily for 11 days to Wistar rats induced a decrease of free triiodothyronine and free thyroxine (fT(3) and fT(4)) and a trend toward an increase of TSH serum levels. Thyroid concentrations of TMP, NDT, and TSO were significantly higher than serum levels, while 3-OHT was never detected. An iodine-supplemented diet administered to a group of rats treated with TMP significantly increased the thyroid concentration of TMP and TSO, but not that of NDT, while it did not affect the concentrations observed in serum and other organs. The increase in plasma TSH is not consistent with the central mechanism hypothesis, and the absence of TPO inhibition by TMP, TSO, and NDT contradicts the TPO inhibition hypothesis. On the contrary, three findings support the hypothesis of iodine trapping through formation of a complex with TMP and TSO: these molecules complex iodine in vitro, they accumulate in the thyroid, and their thyroid concentration is increased when the rats are fed an iodine-supplemented diet.

Animals↗

Liquid chromatography-electrospray mass spectrometry multi-residue determination of pesticides in apples and pears.

This paper describes a rapid, specific and sensitive multi-residue method for the routine quantitative analysis of pesticides of several classes used for the treatment of apples and pears, down to their respective maximum residue limits (MRLs). It involves a rapid extraction procedure and liquid chromatography coupled to electrospray mass selective detection. Seven pesticides were extracted at pH 4.5 with a mixture of acetone-dichloromethane-hexane (50:20:30, v/v/v). Ionization was performed at atmospheric pressure in an electrospray-type source and detection was carried out using the selected ion monitoring (SIM) mode. Extraction recoveries were between 55 and 98% except for methylthiophanate (< 20%). Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 0.01 to 0.02 mg/kg and from 0.02 to 0.05 mg/kg, with relative standard deviation (R.S.D.) less than 19%. An excellent linearity was observed for LOQs up to 5 mg/kg. Intermediate ("inter-assay") precision and accuracy were satisfactory. The method was applied to many fruit samples intended for commercialization.

Chromatography, High Pressure Liquid↗