Observation of cerebrospinal fluid flow with echo-planar magnetic resonance imaging.

Using echo-planar (EP) magnetic resonance imaging (MRI), cerebrospinal fluid (CSF) flow patterns have been demonstrated in the normal subject and patients with pathological conditions including communicating hydrocephalus, aqueduct stenosis and syringohydromyelia. Snap-shot imaging times of 128 ms allow detailed demonstration of transient intraventricular CSF flow patterns, which is not possible with conventional MRI. The potential of EPI as a method for qualitative and quantitative assessment of CSF dynamics is illustrated.

Cerebral Aqueduct↗

Variables influencing tumor uptake of anti-melanoma monoclonal antibodies radioiodinated using para-iodobenzoyl (PIB) conjugate.

Tumor uptake was examined with respect to antigen expression, time-dependent biodistribution, dose of Mab injected, tumor size, and tumor site (i.e., subcutaneous versus lung or liver metastases). NR-ML-05, 96.5, and P94 showed significantly greater uptake in subcutaneous tumors than CL207 and 5.1 (p less than 0.05). NR-ML-05 had a significantly higher tumor uptake at 24 hr (11.9 +/- 0.51) than at 72 hr (4.0 +/- 0.37) or 144 hr (2.7 +/- 0.84) after injection (p less than 0.001). The other four Mabs had similar tumor distribution at all three time points. The tumor uptake of four Mabs (96.5, P94, CL207. 5.1) differed with respect to in vitro versus in vivo binding to tumor, tumor type, dose of Mab, and tumor site (subcutaneous versus metastases). In contrast, NR-ML-05 demonstrated consistent uptake in tumors independent of the above parameters. These data suggest that certain host parameters can influence in vivo tumor targeting depending on characteristics of each Mab studied.

Animals↗

Echo-planar imaging of the human fetus in utero.

We have demonstrated that echo-planar imaging can be used to produce high-quality snapshot images of the human fetus in utero in a fraction of a second. These images are free of motional artifact or blurring and allow detailed depiction of fetal structures in normal and pathological pregnancies.

Fetal Heart↗

Inversion-recovery echo-planar imaging (IR-EPI) at 0.5 T.

Echo-planar imaging is used in combination with a spin preparation phase to produce a T1-weighted image. The small additional time penalty in this procedure does not detract significantly from the ultrahigh-speed imaging capability of EPI, allowing a rapid real-time optimization of tissue parameters in the image display. Results obtained on a head demonstrate this technique.

Electron Spin Resonance Spectroscopy↗

High-speed multislice T1 mapping using inversion-recovery echo-planar imaging.

Tissue contrast in MR images is a strong function of spin-lattice (T1) and spin-spin (T2) relaxation times. However, the T1 relaxation time is rarely quantified because of the long scan time required to produce an accurate T1 map of the subject. In a standard 2D FT technique, this procedure may take up to 30 min. Modifications of the echo-planar imaging (EPI) technique which incorporate the principle of inversion recovery (IR) enable multislice T1 maps to be produced in total scan times varying from a few seconds up to a minute. Using IR-EPI, rapid quantification of T1 values may thus lead to better discrimination between tissue types in an acceptable scan time.

Fourier Analysis↗

The clinical applications of echo planar imaging in neuroradiology.

Ultra high speed echo-planar imaging gives an imaging time typically of the order of a few minutes, facilitating throughput, improving patient tolerance and allowing real time dynamic studies. A complete two dimensional image may be acquired in a single shot lasting between 64 and 128 ms. In echo planar imaging the whole of k-space is sampled as a continuous trajectory. By a rapidly switched Gy frequency encoding gradient, a train of gradient echoes is formed, each corresponding to a line in the k plane. Variable degrees at T2- or T1-weighting can be produced by methods outlined. High quality 128 x 128 transverse axial inversion recovery images of 5-10 mm thickness are obtained in 128 ms plus the inversion time.

Adult↗

Echo planar imaging of an infant with pectus excavatum.

Echo planar imaging has enabled us to image safely and without sedation the thorax of an infant with pectus excavatum deformity. The heart was displaced into the left side of the thorax, and the right lung was calculated to be 1.6 times larger than the left lung.

Funnel Chest↗

Study of internal structure of the human fetus in utero by echo-planar magnetic resonance imaging.

The ultrafast echo-planar magnetic resonance imaging technology, developed and built in Nottingham, has been used to produce the first snapshot images of the human fetus in utero. The imager, operating at a proton resonance frequency of 22 MHz, produces transaxial views in 64 or 128 milliseconds. These images comprise either 64 x 128 or 128 x 128 pixels with an in-plane resolution of 3 x 3 mm2. The slice thickness is 10 mm. Fetal scans of up to 32 contiguous slices are produced in a few minutes. These have been used to study the internal structure of the uterus and the fetus in a range of cases with gestations ranging from 26 weeks to term. Echo-planar imaging seems particularly suitable as an imaging modality since its high speed obviates image blurring arising from fetal motion.

Fetal Diseases↗

Estimation of lung volume in infants by echo planar imaging and total body plethysmography.

Echo planar imaging (an extremely fast method of magnetic resonance imaging) was used to measure lung volume in a group of nine infants, all of whom had had respiratory problems. The mean echo planar imaging estimate of total lung volume was 44 +/- 9 ml/kg. In each case the right lung was larger than the left (ratio 52.8:47.2%). The mean thoracic gas volume was 36 +/- 8 ml/kg. The entire sequence of images of the thorax (about 400) takes five minutes to complete, infants require no sedation, and there are no side effects.

Female↗

Ultrafast magnetic resonance scanning of the liver with echo-planar imaging.

Echo-planar imaging (EPI) is a magnetic resonance imaging (MRI) technique which provides MR images in, typically, 50-100 ms. The potential of EPI as an imaging modality for the liver has been investigated in volunteers and patients with liver disease. Images with improved quality are presented. Obtained at a field strength of 0.52 Tesla, these true unaveraged snap-shot images have larger data arrays, comprising 128 X 128 pixels.

Aged↗

Echo planar imaging of the human fetus in utero at 0.5 T.

The snap-shot capability of the echo-planar imaging technique is used to freeze motion effectively in human fetal studies in utero. These first results obtained at 0.5 T demonstrate diagnostic quality images without the need for averaging. Although averaging improves the image signal to noise ratio, it is shown that significant image blurring is produced even when only eight separate images are averaged over a period of a few seconds. Results are presented showing anatomical detail of the internal organs of the fetus. Some pathology is also demonstrated. These results were obtained using the modulus blipped echo-planar single-pulse technique (MBEST). Running at 10 frames/second, the modulus version of the fast low-angle excitation echo-planar technique (FLEET) is used to produce ungated fetal cardiac movies.

Female↗

Snapshot imaging at 0.5 T using echo-planar techniques.

Echo-planar imaging using a magnetic field strength of 0.5 T has resulted in an improvement in image quality compared with recent images published at 0.1 T. The sensitivity of the technique to main magnetic field inhomogeneity and transient eddy currents has necessitated innovations in gradient and radiofrequency coil design. These improvements are described, and new variations in the echo-planar pulse sequence which provide better contrast and allow separate imaging of water and fat distributions are presented.

Abdomen↗

PEEP--a rapid chemical-shift imaging method.

The phase-encoded echo-planar (PEEP) technique, a variant of echo-planar imaging, is used to achieve simultaneous high-speed spatial and chemical-shift data acquisition. This technique is the 2DFT equivalent of the projection reconstruction echo-planar method for chemical-shift imaging. Examples of images and spectra obtained using the PEEP method are presented.

Magnetic Resonance Imaging↗

Whole-body echo-planar MR imaging at 0.5 T.

The ultra-high-speed echo-planar imaging technique produces instant snapshot magnetic resonance images in exposure times ranging from approximately 10 to 100 msec. A particular variant, the modulus blipped echo-planar single-pulse technique (MBEST), possesses two advantages: First, it makes the technique experimentally more robust; second, it introduces inherent T2 weighting in the images. The authors have used MBEST with an exposure time of 64 msec to explore the potential range of clinical applications in a series of normal volunteers. Applications include evaluation of the heart, renal function, and gastrointestinal tract. All images were obtained with proton resonances at 22 MHz.

Abdomen↗

Gastrointestinal tract: dynamic MR studies with echo-planar imaging.

Gastrointestinal (GI) tract motility was depicted in four human volunteers with the high-speed echo-planar imaging technique: modulus blipped echo-planar single-pulse technique (MBEST). Data acquisition times of 64 and 128 msec obviate image degradation due to motion without the need for gut paralysis and allow imaging of the GI tract in real time. Peristaltic patterns of the gastric antrum and proximal small intestine were depicted for fasting and fed subjects and subjects in whom peristalsis had been pharmacologically stimulated. The potential for quantitative measurements of GI tract motion with this new technique was demonstrated.

Adult↗