Search PubMed⌕ Search

Biomedical subjects

P Mabo

Publications and source records attributed to P Mabo.

86 records · Page 5Linked to original sources

Lack of physiological adaptation of the atrioventricular interval to heart rate in patients chronically paced in the AAIR mode.

Seventeen consecutive patients, aged 56 +/- 12, were chronically paced in the AAIR mode for a symptomatic sinus node disease with atrial chronotropic incompetence defined by a peak exercise heart rate (HR) less than 75% of the maximal predicted heart rate (MPHR) mean = 65 +/- 10%). Sensors used were activity sensing (n = 7), minute ventilation (n = 6), or respiratory rate (n = 4). Basic pacing rate was programmed at 71 +/- 5 beats/min and the maximal sensor rate at approximately 85% MPHR (143 +/- 10); other sensor parameters were programmed individually. Six months after implant, two standardized and symptom limited exercise tests were performed in random order, AAI and AAIR modes, respectively. AAIR pacing significantly improved peak exercise HR (139 +/- 14 vs 112 +/- 30 beats/min; P less than 0.01), maximal sustained workload (132 +/- 42 vs 110 +/- 38 watts; P less than 0.02), and total exercise duration (724 +/- 299 vs 594 +/- 245 sec; p less than 0.02) compared to the AAI mode. In all 17 patients, HR was continuously sensor driven in the AAIR mode, making it possible to precisely study the adaptation of the stimulus-R interval and of the stimulus-R:RR ratio during exercise. Six patients normally adapted with a progressive shortening. Six others did not adapt at all without any variation of interval. Five patients paradoxically increased their stimulus-R interval (286 +/- 10 msec at peak E vs 220 +/- 19 msec at rest) and their stimulus-R:RR ratio (67 +/- 20% vs 29 +/- 4%), producing P waves occurring immediately after, or even within the R wave of the preceding cycle; two patients complained of severe exercise related symptoms corresponding to the so-called "AAIR pacemaker syndrome." The principal factors involved in the nonadaptation of AV interval to HR were related to the patient (organic heart disease, with the particular problem of the denervated heart; the bradytachy syndrome; and the use of drugs, especially beta blockers and Class I antiarrhythmic drugs) or to the pacemaker ("overstimulation" phenomenon). These observations constitute an additional argument for wider indications of implanting DDDR units in these patients.

Adaptation, Physiological↗

[Aneurysm of a saphenous vein aortocoronary shunt caused by fissure syndrome].

The authors report a new case of an aneurysm of a saphenous vein aorto-coronary shunt. The aneurysm manifested itself by a fissure syndrome in a man 48 years of age, 9 years after myocardial revascularization surgery. A chest X-ray revealed a right paracardiac opacity, and two-dimensional ultrasound picked up an expansive, hypoechoic mass. The diagnosis was confirmed by coronary artery angiography. The aneurysm was opened up and the proximal anastomosis sutured. After a follow-up period of 30 months, the patient is asymptomatic.

Aneurysm↗

Dynamic electrophysiology of ventriculoatrial conduction: implications for DDD and DDDR pacing.

The behavior of ventriculoatrial conduction (VAC) during exercise remains unknown. In order to determine its characteristics and the consequences it might have on dual chamber pacemaker technology and programming, 17 patients underwent an electrophysiological study (EPS) of atrioventricular conduction (AVC) and of VAC during a protocol including three steps: supine rest, upright position, and finally during cycloergometric exercise; the measurements were done at progressively increasing pacing rates. During a preimplantation EPS, Wenckebach points AVC-W and VAC-W and conduction times, AVCT and VACT (as a function of pacing rate), were measured in ten consecutive patients using temporary leads and an external device. In another study, AVCT, VACT, AVC-W, and VAC-W were measured by telemetric recordings under identical conditions in seven patients implanted earlier with a DDD pacemaker. A 1/1 VAC was observed in 7/17 patients (41%) at rest, and in 13/17 patients (76%) at the end of the protocol; VAC was never observed in 4/17 patients (23%), but occurred in six of the ten patients initially free, three standing at rest and three on exercise. For all patients, the VAC behavior remained of "nodal" type, indicated by a progressive increase in VACT as pacing rate rose up to the VAC-W point. Neither the existence of exercise-induced VAC nor the maximal VACT-W could be predicted from AVC or VAC data obtained at rest. However, at the same pacing rates, standing up and exercise induced a shortening effect on VACT, and improved the VAC-W by an average of 33%. These results suggest that the electrophysiological behavior of VAC does not obey any general rule and cannot be predicted individually. It would thus appear unwise to base pacemaker mediated tachycardia (PMT) protection solely on long postventricular atrial refractory period (PVARP) programming in DDD patients. This work also revealed the potential risks of a rate responsive auto-adaptive PVARP algorithm as proposed in certain new devices.

Adult↗

[Myocardial infarction and massive biventricular thrombosis during thrombocytopenia induced by pentosan polysulfate and heparin].

Many cases of immuno-allergic thrombocytopenia complicated by serious thromboembolism induced by heparin or other heparinoids such as pentosan polysulphate have been reported. This case is of interest for two reasons: first of all, it was induced by pentosan polysulphate and then reactivated by secondary administration of heparin; secondly, it was complicated successively by an infero-apical myocardial infarction with probable spontaneous lysis of a coronary thrombosis because coronary arteriography performed one month later was normal, and then by massive biventricular thrombosis requiring surgical thrombectomy under cardiopulmonary bypass. Tests of platelet aggregation were positive to standard heparin and to several low molecular weight fractions. The outcome was favorable when the responsible substances were withdrawn.

Blood Coagulation Tests↗

[Benefits and limits of single chamber atrial pacing with adaptive rate].

Twelve patients with isolated symptomatic sinus node dysfunction or bradycardia-tachycardia syndrome with atrial chronotropic incompetence during exercise testing were managed by single chamber rate responsive atrial pacing (AAIR) when AV conduction was normal, or by a dual chamber DDDR pacemaker programmed in the AAIR mode when AV conduction was abnormal, and followed up for 12.5 +/- 9.8 months. The patients were assessed clinically, by 3 monthly ECG and Holter recordings and comparative exercise tests in AAI and AAIR modes at the 6th month. One patient with an AAIR system was excluded at M21 because of symptomatic AV block requiring reimplantation of a DDD pacemaker. Ten of the 11 remaining patients are asymptomatic and have an excellent quality of life; one patient had invalidating symptoms on exercise attributed to the "AAIR pacemaker syndrome" which were corrected by reprogramming the pacemaker and modifying the medical therapy. The comparative exercise stress tests showed a significantly higher heart rate in the AAIR mode compared to AAI pacing at the initial and intermediate exercise levels (30 to 70 W); on the other hand, the heart rates were not significantly different at the highest exercise levels although in the AAI mode, the terminal acceleration sometimes occurred in junctional rhythm whereas it was usually an atrial paced rhythm in the AAIR mode. The total duration of exercise was longer in the AAIR mode (+22%; p less than 0.01) when the 8/11 patients with chronotropic incompetence during the baseline study were considered. The spike-R interval adapted normally to exercise in only one case: in the other patients, the interval remained constant or, in the worst of cases (N = 4), it increased paradoxically, to result in the "AAIR pacemaker syndrome": this phenomenon is observed mainly in patients treated by antiarrhythmics and/or betablockers. The AAIR mode would therefore seem to be a simple, effective and reliable method of treating patients with sinus node dysfunction and chronotropic incompetence; however, the failure of adaptation of the PR interval is a real limitation to its use and may constitute an argument in favour of the choice of a DDR pacemaker in these patients.

Adult↗

[Auriculoventricular block disclosed in the exercise test].

Sixteen patients, 14 of whom described stress related symptoms, present a severe atrio-ventricular block (A-V B), identified during a stress test while the ECG at rest showed a 1/1 atrioventricular conduction (AV). The electrophysiological study (EPS) creates the A-B Block through atrial stimulation and specifies the location of the A-V B: intra-hissian in 8 patients (7 with small QRS an 1 with widened QRS) and infra-hissian in 8 patients (all with widened QRS). Non-invasive methods constitute the prime approach in the diagnostic work-up of stress symptoms. The ideal treatment consists of a dual-chamber cardiac stimulation.

Adult↗

Benefits and limits of selective right ventricular cineangiography in arrhythmogenic right ventricular dysplasia.

Cineangiographic data from patients with probable arrhythmogenic right ventricular dysplasia (ARVD) were compared with those from matched controls. Some changes previously thought to indicate ARVD did not do so in this study. The abnormalities specific for ARVD were free wall morphological and wall motion abnormalities, particularly bulges and mamillated akinetic areas.

Adolescent↗

Haemodynamic benefit of a rate-adapted A-V delay in dual chamber pacing.

In dual chamber pacing, an improvement of exercise capacity is expected when the atrial refractory period is shortened, because the 2/1 point is increased. This objective can be achieved by greatly reducing atrioventricular delay (AVD) on exercise. Are such variations (up to 100-120 ms) detrimental from a haemodynamic standpoint? This study was performed to analyse this particular aspect of DDD pacing. Three DDD pacing modes, differing by their AVDs (fixed 200 ms AVD, fixed 150 ms AVD, and rate-adapted AVD) were tested in random order, with a haemodynamic protocol including ten patients with chronic atrio-ventricular (A-V) block. For the rate-adapted AVD pacing mode, AVD was reduced by 20 ms every 10 beats min-1 increment (from 220 ms at 90 beats min-1 to 100 ms at 150 beats min-1). Pacing rate was increased from 90 to 150 beats min-1 by increments of 10 beats min-1 every 5 min. Cardiac performance was significantly improved with the rate-adapted AVD above the two fixed AVDs, despite a large AVD variation. When AVD was rate adapted, cardiac index, stroke volume index and left ventricular systolic work index were generally higher and pulmonary capillary wedge pressure, pulmonary arterial pressure and systemic vascular resistances were generally lower, especially at 120, 130 and 140 beats min-1. Comparing the two fixed AVDs, 200 AVD improved cardiac function more at lower heart rates, whereas 150 AVD improved cardiac function more at higher heart rates. Despite its limitations, this study demonstrates that the potential benefits of reducing AVD with increasing heart rates should be twofold in dual chamber pacing: (a) haemodynamic, optimizing cardiac performance on exercise for all heart rates, especially in cases of organic heart disease; (b) electrophysiologic, permitting a sufficiently rapid maximal tracking rate in cases with long post-ventricular atrial refractory periods, allowing a satisfactory level of exercise.

Aged↗

Failure of the exercise test to predict the anterograde refractory period of the accessory pathway in Wolff Parkinson White syndrome.

Modifications of the delta wave on the surface ECG during an exercise stress test were compared to electrophysiological variations in accessory pathway (AP) refractoriness and in AV node conduction, during intravenous isoproterenol infusion in ten patients with WPW syndrome. In one patient, the delta wave persisted unchanged at the end of exercise and, with isoproterenol, there was a greater reduction in the AP anterograde effective refractory period (AERP) than in AV node conduction time. In three patients, the delta wave became less and less apparent but without completely disappearing; in these patients, the slight reduction of the AERP in the accessory pathway with isoproterenol was comparable to the reduction in AV node conduction time, explaining the progressive fusion between the two activation fronts. In the six other patients, the delta wave completely disappeared during exercise: in two cases, suddenly from one cycle to the next with strong concordance between the measured (isoproterenol) and the estimated (exercise test) AERP in the AP; in four cases, the disappearance was progressive with a significantly greater reduction in the AV node conduction time than in the measured AERP of AP which was nonetheless very short, 190 to 225 ms, during isoproterenol infusion. These findings confirm the limitations of the exercise test to predict the AERP of the AP. In addition, they demonstrate that modifications in the delta wave during exercise result from a balance between the relative effects of sympathetic stimulation on refractoriness of AP and normal AV conduction.

Adult↗

Physiological relationship between AV interval and heart rate in healthy subjects: applications to dual chamber pacing.

The purpose of this paper is to specify the mathematical relationship between spontaneous AV interval (AVI) and heart rate (HR), the amplitude and rate of variation of AVI, and the physiological factors likely to affect these characteristics. Ten patients with healthy hearts were studied. Two catheter electrodes were positioned in the right atrium and at the tip of the right ventricle respectively, allowing the detection of endocardial signals. The AV and AA intervals for each heart cycle were digitized to an accuracy of +/- 1 msec. Measurements were made at rest, then during a stress test on an exercise bicycle, and finally during the recovery phase. The results show that adaptation is very precise and takes place instantly. Any variation in heart rate causes an immediate, inversely proportional variation in AVI. Adaptation follows a linear pattern, generally with relatively low amplitude and an average AVI reduction of 27.5 +/- 11.2 msec for an average HR increase of 78.7 +/- 22.5 bpm, i.e., a decrease of 4 +/- 2.1 msec for an HR variation of 10 bpm. The amplitude and variation rate of AVI seem to be independent of the age and base value of the PR interval. These observations may be useful for designing new VDD or DDD pacemakers that automatically adapt the AV interval to the instantaneous heart rate. The hemodynamic benefits of this adaptation were also demonstrated.

Adolescent↗

Serum alpha-L-fucosidase: a new marker for the diagnosis of primary hepatic carcinoma?

alpha-L-fucosidase, a lysosomal enzyme which catabolizes fucoproteins, was studied in sera from 30 controls, 32 patients with primary hepatic carcinomas, 24 patients with secondary metastatic liver carcinomas and 36 patients with cirrhosis. Serum alpha-L-fucosidase was increased in primary hepatic carcinomas (145.5 +/- 12 nkat per liter) with a high statistical significance versus controls (51.4 +/- 4.5 - p less than 10(-7], secondary metastatic liver carcinomas (58.9 +/- 6.4 - p less than 10(-5] and cirrhotics (71.3 +/- 6 - p less than 10(-5). A level exceeding 110 was a useful marker for the diagnosis of primary hepatic carcinoma with 75% sensitivity and 90% specificity.

Adenocarcinoma↗