Search PubMed⌕ Search

Biomedical subjects

P Mabo

Publications and source records attributed to P Mabo.

At least 37 records · Page 2Linked to original sources

Comparative effects of permanent biventricular pacing for refractory heart failure in patients with stable sinus rhythm or chronic atrial fibrillation.

This study aimed to compare the long-term benefit of biventricular pacing in drug-refractory heart failure in patients with dilated cardiomyopathy who were in stable sinus rhythm or had persistent atrial fibrillation. The results showed that permanent biventricular pacing in such patients significantly improves exercise tolerance in both groups of patients; however, the benefit tended to be greater in patients with atrial fibrillation.

Aged↗

Cardiac loading conditions modify the ventricular repolarization in conscious dogs with heart failure.

Changes in myocardial loading conditions influence the ventricular action potential via mechanoelectric feedback, a mechanism impaired in pathology. In vivo the QT interval of the electrocardiogram which reflects the action potential duration allows appropriate determination of its modifications. The effects of changes in cardiac loading conditions (load reduction with trinitrin; volume loading with Plasmion) on regional function and ventricular local electrogram were investigated in conscious dogs before (control) and after 4 weeks of rapid pacing (dilated cardiomyopathy, DCM). In controls both interventions increased heart rate. Trinitrin increased end-diastolic wall thickness (EDWth, P<0.001) and reduced absolute QT interval duration (P<0.05). Plasmion decreased EDWth (P<0.001) and increased left ventricular end diastolic pressure (LVEDP, P<0.001) without QT interval alteration. However, the corrected QT interval was unchanged in both interventions. In DCM, trinitrin did not change the QT interval. Plasmion increased LVEDP (P<0.01) and prolonged QT and corrected QT intervals (P<0.01) despite the tachycardia. In controls the changes in cardiac loading conditions did not modify the QT interval, suggesting intact endogenous regulation of repolarization. The impaired adaptation observed in DCM contributed to an increase in QT interval following volume loading. In this model, a prolonged repolarization after abrupt volume loading may result from enhanced or disclosed mechanoelectric feedback.

Animals↗

A pilot experience with permanent biventricular pacing to treat advanced heart failure.

BACKGROUND: The prognosis and quality of life of patients with advanced heart failure remain poor. The purpose of this study was to evaluate new nonpharmacologic approaches. Biventricular pacing was proposed in this indication, based on the encouraging results of acute hemodynamics studies. METHODS: Fifty patients with drug-resistant heart failure (New York Heart Association [NYHA] class III/IV, 16 of 34) were consecutively implanted with biventricular pacemakers. All patients had severe dilated cardiomyopathy and intraventricular conduction delay. Survival, NYHA class, electrocardiogram, echocardiographic data, and exercise tolerance were assessed over a mean follow-up period of 15.4 +/- 10. 2 months. RESULTS: At the end of follow-up, 55% of patients were alive without heart transplantation or left ventricular assistance device. The mortality rate was significantly lower in class III (12. 5%) than in class IV patients (52.5%). In survivors, biventricular pacing significantly improved symptoms (NYHA class 2.2 +/- 0.5 at follow-up vs 3.7 +/- 0.5 at baseline) and exercise tolerance ((. )VO(2) peak 15.5 +/- 3.4 mL/min per kilogram at follow-up vs 11.1 +/- 3 mL/min per kilogram at baseline). CONCLUSIONS: Biventricular pacing appears to improve the functional status of patients with dilated cardiomyopathy with advanced heart failure. The technique appears to be attractive as an additive treatment, especially in class III patients. Controlled randomized studies are needed to validate this novel concept.

Aged↗

Junctional rhythm during slow pathway radiofrequency ablation in patients with atrioventricular nodal reentrant tachycardia: beat-to-beat analysis and its prognostic value in relation to electrophysiologic and anatomic parameters.

INTRODUCTION: Junctional rhythm usually is considered a sensitive but nonspecific marker of successful ablation of the slow pathway in AV nodal reentrant tachycardia. Nevertheless, this junctional rhythm has been little studied, and its relations to recognized predictors of successful radiofrequency (RF) application were never established in any study. METHODS AND RESULTS: Thirty-nine patients underwent RF ablation of the slow pathway for AV nodal reentrant tachycardia. Ninety RF applications were delivered, and each ablation site was determined using three different fluoroscopic projections. Six anatomic zones were defined from low posterior septum to the site of distal His-bundle recording (P1, P2, M1, M2, A1, and A2). Characteristics of junctional rhythm during RF applications were analyzed. Atrial electrogram characteristics at the ablation sites also were studied. All patients had successful slow pathway ablation, without any complication. The ablation sites were located as follows: 41 at P1, 26 at P2, 20 at M1, and 3 in M2. Forty RF applications were successful: 14 of 41 attempts at P1, 7 of 26 at P2, 16 of 20 at M1, and 3 of 3 at M2. Mid-septal ablation site (M1 and M2) was associated with higher occurrence of junctional rhythm (P < 0.0001), earlier first junctional beat (P = 0.008), and earlier occurrence of the longest junctional burst (P = 0.03) compared with posterior ablation site (P1 and P2). The combination of a mid-septal ablation site and a first junctional beat occurring < or = 3 seconds after onset of RF application identified successful RF application with 100% accuracy. Using multivariate analysis, the ablation site, duration of atrial electrogram (including slow pathway potential when present), and occurrence of junctional rhythm were independent predictors of success. CONCLUSION: Successful slow pathway ablation depends on many factors. Junctional rhythm characteristics are related to the site of RF delivery and can be helpful in assessing successful slow pathway ablation.

Adolescent↗

Long-term effects of biatrial synchronous pacing to prevent drug-refractory atrial tachyarrhythmia: a nine-year experience.

INTRODUCTION: Results of previous studies suggest that atrial resynchronization by multisite atrial pacing may contribute to prevention of recurrences in patients with drug-refractory atrial tachyarrhythmias and significant intra-atrial conduction delay. METHODS AND RESULTS: To verify this hypothesis, a prospective noncontrolled study of 86 patients (mean age 66 +/- 10 years) was conducted in a single center between January 1989 and February 1998. Inclusion criteria were P wave duration > or = 120 msec with interatrial conduction time > or = 100 msec, and history of multiple recurrences of atrial tachyarrhythmias (mean 7 +/- 4.8 episodes) evolving in a persistent mode for at least 6 months despite optimized drug treatment (mean 2.7 +/- 1.8 drugs/patient). Patients were chronically implanted with a pacing system that ensured permanent biatrial pacing using two atrial leads, one placed in the high right atrium and the other one into the mid or the distal part of the coronary sinus. P wave duration decreased from a mean value of 187 +/- 29 msec before implant to 106 +/- 14 msec (P < 0.0001) under biatrial pacing. After a 33-month mean follow-up (range 6 to 109), 55 patients (64%) remained in sinus rhythm, including 28 patients (32.6%) without any documented recurrence and 27 patients with one or more recurrences in a paroxysmal or in a persistent form. In these 55 patients, drug treatment was significantly reduced in relation to the preimplantation period (1.4 +/- 0.6 vs 1.7 +/- 0.5 drugs/patient; P = 0.011). The other 31 patients went into chronic atrial arrhythmia after a mean period of 26 months. The only predictive factor of positive response was a spontaneous P wave duration < 160 msec at baseline. CONCLUSION: The results are consistent with a preventive effect of permanent biatrial pacing on recurrent and drug-refractory atrial arrhythmias associated with intra-atrial conduction delay.

Adult↗

[Cardiac insufficiency: prevention of ventricular arrhythmias].

Ventricular arrhythmias are particularly common in cardiac failure and their mechanisms are very complex. The prevention of these ventricular arrhythmias is only worthwhile if it results in benefits in terms of reduction of the risk of sudden death and in improvement in life expectancy. However, the relationship between complex ventricular arrhythmias and sudden death is far from established. The first problem is, therefore, to select the patients at high risk of sudden death. Unfortunately, there are no reliable markers of arrhythmic risk; only patients at low risk can be reasonably well identified on clinical and haemodynamic assessment and the results of ambulatory and signal averaged ECG. When an antiarrhythmic treatment seems to be required, the choice is very limited in practice. There is no role for Class I antiarrhythmics to play in this indication. Amiodarone, with its complex electrophysiological profile enabling an interaction with all potential mechanisms of ventricular arrhythmias, is a first-line drug in cardiac failure because of its efficacy and good myocardial tolerance. However, the benefits of amiodarone therapy in terms of reduction of global mortality have not been demonstrated, especially in view of the discordance between the results of the GESICA and CHF STAT trials. On the other hand, the value of betablockers, whether conventional molecules like bisoprolol (CIBIS II study) or metoprolol (MERIT-HF study), or molecules with a special profile such as carvedilol, has been clearly established. In association with conventional diuretics and angiotensin converting enzyme inhibitors, they reduce global mortality by about 35% and sudden death by 40%. However, the future possibly lies with non-pharmacological approaches such as the implantable defibrillator, at least in patients clearly identified as being at high risk of arrhythmic death, resuscitated from cardiorespiratory arrest due to documented ventricular fibrillation or presenting with haemodynamically poorly tolerated ventricular tachycardia. The automatic defibrillator could improve the prognosis of these patients, irrespective of their functional status (NYHA, Classes I, II or III). In practice, "rhythmological" management of cardiac failure cannot be dissociated from the haemodynamic and neuro-hormonal aspects of the affection, and only a multi-factorial approach is being realistic.

Anti-Arrhythmia Agents↗

Electrocardiographic predictive factors of long-term clinical improvement with multisite biventricular pacing in advanced heart failure.

Biventricular pacing has recently been proposed for treating patients with drug refractory heart failure and intraventricular conduction delay. The purpose is to restore ventricular relaxation and contraction sequences as homogeneously as possible. The aim of this study was to determine if some factors could predict the long-term clinical effectiveness of that new treatment. This study included 26 patients, aged 66 +/- 7 years, with drug refractory heart failure and wide QRS. Patients were implanted with a biventricular pacemaker. The left ventricle was paced through a coronary sinus tributary. New York Heart Association functional class, exercise tolerance, and left ventricular (LV) ejection fraction were collected at baseline and after pacemaker implantation. Patients were divided into 2 groups: group I = responders; group II = nonresponders. QRS duration and axis at baseline and during biventricular pacing, interventricular conduction time, and LV and right ventricular lead positions were compared between the 2 groups. Group I patients (n = 19) had a mean reduction of 1.3 in functional class and an increase in peak oxygen consumption rate by a mean of 50%. The only parameter that differed between the 2 groups was the QRS duration during biventricular pacing, with a significantly shorter value in group I than in group II (154 +/- 17 vs 177 +/- 26 ms; p = 0.016). Thus, a positive response to biventricular pacing is correlated with the quality of electrical resynchronization. The optimal positions of the right and LV leads would be those that could induce the greatest shortening of QRS duration.

Aged↗

Optimal right ventricular pacing site in chronically implanted patients: a prospective randomized crossover comparison of apical and outflow tract pacing.

OBJECTIVES: To evaluate the long-term functional and hemodynamic effects of right ventricular outflow tract (RVOT) pacing by comparison with right ventricular apical (RVA) pacing. BACKGROUND: Acute studies have suggested that RVOT pacing could significantly improve cardiac performance in comparison with RVA pacing but no data are available in chronically implanted patients. METHODS: Sixteen patients with chronic atrial tachyarrhythmia and complete AV block were included. Left ventricular ejection fraction (LVEF) was > or =40% in ten and <40% in six. Patients were implanted with a standard DDDR pacemaker connected to two ventricular leads. A screw-in lead was placed at the RVOT and connected to the atrial port. A second lead was positioned at the RVA and connected to the ventricular port. Right ventricular outflow tract and RVA pacing was achieved by programming either the AAIR or the VVIR mode respectively. Four months later patients were randomized so as to undergo either RVOT or RVA pacing for three months according to a blind crossover protocol. Apart from the pacing mode, programming remained unchanged throughout the study. At the end of each period, NYHA class, LVEF, exercise time and maximal oxygen uptake were assessed. RESULTS: No significant difference was observed between the two modes for all the parameters analyzed. These identical results were observed in all patients globally, in patients with LVEF > or =40% as in those with LVEF <40%. CONCLUSIONS: Within the limits of this study, no symptomatic improvement or hemodynamic benefit was noted after three months of RVOT pacing, by comparison with RVA pacing.

Aged↗

Effects of permanent dual-chamber pacing on mitral regurgitation in hypertrophic obstructive cardiomyopathy.

AIMS: To assess the effects of chronic dual-chamber pacing on mitral regurgitation in hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: Twenty-three patients with hypertrophic obstructive cardiomyopathy and mitral regurgitation. treated with DDD pacing for 16 +/- 14 months, were included in the study. Mitral regurgitation was assessed by Doppler-echocardiography using semi-quantitative analysis (grades I-IV) and by measuring the maximum regurgitant jet area/left atrial area ratio. At the end of follow-up, DDD pacing reduced the outflow gradient from 93 +/- 37 mmHg to 31 +/- 30 mmHg (P<0.0001). Nine of the 14 patients who initially had > or =grade II mitral regurgitation improved by at least one grade, two of them exhibiting dramatic improvement (from grade IV and III to grade I). The regurgitant jet area/left atrial area ratio was reduced with DDD pacing from 20 +/- 13% to 11 +/- 6% (P<0.0001). Patients who had significant mitral regurgitation despite pacing were those whose outflow gradient remained high or those with mitral valve organic abnormalities (mitral annulus calcification or mitral valve prolapse). In the absence of organic abnormalities other than leaflet elongation, there was a significant correlation between the gradient value achieved with DDD pacing and the extent of mitral regurgitation (P<0.05). CONCLUSION: In the absence of organic mitral valve abnormalities, DDD pacing reduces in parallel mitral regurgitation and left ventricular outflow gradient. In such patients therefore, significant mitral regurgitation is not a contraindication to pacing.

Adult↗

Pacemaker lead infection: echocardiographic features, management, and outcome.

OBJECTIVE: To compare transthoracic and transoesophageal echocardiography (TTE, TOE) in patients with permanent pacemaker lead infection and to evaluate the safety of medical extraction in cases of large vegetations. METHODS: TTE and TOE were performed in 23 patients with definite pacemaker lead infection. Seventeen patients without previous infection served as a TOE reference for non-infected leads. RESULTS: TTE was positive in seven cases (30%) whereas with TOE three different types of vegetations attached to the leads were visualised in 21 of the 23 cases (91%). Of the 20 patients with vegetations and lead culture, 17 (85%) had bacteriologically active infection. Left sided valvar endocarditis was diagnosed in two patients. In the control group, strands were visualised by TOE in five patients, and vegetations in none. Medical extraction of vegetations >/= 10 mm was performed in 12 patients and was successful in nine (75%) without clinical pulmonary embolism. After 31.2 (19.1) months of follow up (mean (SD)), all patients except one were cured of infection; three died from other causes. CONCLUSIONS: Combined with bacteriological data, vegetations seen on TOE strongly suggest pacemaker lead infection. Normal TTE examinations do not exclude this diagnosis because of its poor sensitivity. Medical extraction of even large vegetations appeared to be safe.

Adult↗

Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure.

OBJECTIVES: The aim of this study was to assess the potential acute benefit of multisite cardiac pacing with optimized atrioventricular synchrony and simultaneous biventricular pacing in patients with drug-refractory congestive heart failure (CHF). BACKGROUND: Prognosis and quality of life in severe CHF are poor. Various nonpharmacological therapies have been evaluated but are restricted in their effectiveness and applications. In the early 1990s, dual chamber pacing (DDD) pacing was proposed as primary treatment of refractory CHF but results were controversial. Recently, tests to evaluate the effect of simultaneous pacing of both ventricles have elicited a significant improvement of cardiac performance. METHODS: Acute hemodynamic study was conducted in 18 patients with severe CHF (New York Heart Association class III and IV) and major intraventricular conduction block (IVCB) (QRS duration = 170+/-37 ms). Using a Swan-Ganz catheter, pulmonary artery pressure, pulmonary capillary wedge pressure (PCWP) and cardiac index (CI) were measured in different pacing configurations: atrial pacing (AAI) mode, used as reference, single-site right ventricular DDD pacing and biventricular pacing with the right ventricular lead placed either at the apex or at the outflow tract. RESULTS: The CI was significantly increased by biventricular pacing in comparison with AAI or right ventricular (RV). DDD pacing (2.7+/-0.7 vs. 2+/-0.5 and 2.4+/-0.6 l/min/m2, p < 0.001). The PCWP also decreased significantly during biventricular pacing, compared with AAI (22+/-8 vs. 27+/-9 mm Hg; p < 0.001). CONCLUSIONS: This acute hemodynamic study demonstrated that biventricular DDD pacing may significantly improve cardiac performance in patients with IVCB and with severe heart failure, in comparison with intrinsic conduction and single-site RV DDD pacing.

Aged↗

Permanent left ventricular pacing with transvenous leads inserted into the coronary veins.

This paper describes a preliminary experiment-conducted jointly by 2 centers-of permanent left ventricular pacing using leads inserted by the transvenous route and through the coronary sinus into the cardiac veins of the left ventricle free wall. The aim was to obtain permanent biventricular pacing in a totally endocavitary configuration in patients with severe LV dysfunction and drug-refractory heart failure. Two types of leads were used: nonspecific unipolar leads at the beginning of the experiment, followed by leads specifically designed to be used in the coronary sinus in a second step. The electrode could be fitted in an adequate location in 35 of the 47 patients (75.4%), with a 1.15 +/- 0.7 V acute pacing threshold and 11.8 +/- 5.7 mV R wave amplitude. The success rate was significantly higher with the specific electrodes (81.8% vs 53.3%, p < 0.001). The pacing and sensing thresholds upon implantation were not influenced by the type of lead or by the localization of the cardiac vein that was catheterized (great cardiac vein, lateral vein, postero-lateral or posterior vein, mid cardiac vein). In contrast, the pacing threshold was significantly lower (0.8 +/- 0.2 vs 1.8 +/- 0.8 V; p = 0.002) and the R wave amplitude tended to be greater (13.1 +/- 4.5 mV vs 9.3 +/- 6.5 mV; p = 0.07) when the tip electrode could be inserted distally into the vein, by comparison with a proximal site near the ostium. At the end of follow-up (10.2 +/- 8.7 months), 34 out of the 35 leads were still fully functional, with a chronic pacing threshold of 1.8 +/- 0.7 V and a R wave amplitude of 10.7 +/- 6 mV. To conclude, permanent LV pacing via the transvenous route is possible in most patients, with excellent safety and long-term results.

Aged↗

Multisite pacing as a supplemental treatment of congestive heart failure: preliminary results of the Medtronic Inc. InSync Study.

This report describes the initial results of the "InSync" study, a European and Canadian multicenter trial that examines the safety and efficacy of a multisite pacemaker (Medtronic InSync) and of left ventricular pacing leads (Medtronic 2187 and 2188) implanted via a cardiac vein as a supplemental treatment of refractory congestive heart failure. Over a 10-month period, the system was implanted successfully in 68 of the 81 (84%) patients who had been enrolled in the study. The 68 patients were, on average, 66 +/- 10 years old, had a mean left ventricular ejection fraction (LVEF) = 21% +/- 9%, and 63% were in NYHA functional Class III and 37% were in Class IV. No system implant related complication occurred. During follow-up, 7 of 10 patients who exited the study had died, 4 suddenly. There was a clinical benefit among surviving patients, which was corroborated by a significant improvement in NYHA functional class and in the Minnesota Living with Heart Failure Quality of Life Questionnaire Score (MLS) and by a longer distance covered during a 6-minute walk test. This clinical improvement was associated with a significant narrowing of the paced QRS complex during biventricular pacing, a significant decrease in the interventricular mechanical delay, and a trend towards an increase in the duration of ventricular filling. These encouraging preliminary results confirm the feasibility and reliability of this new multisite pacing system in the management of dilated cardiomyopathy and support the continuation of further evaluations of this complementary treatment of refractory congestive heart failure.

Aged↗

Mahaim tachycardias.

Patients with Mahaim fibres form a distinct subgroup of the pre-excitation syndromes (less than 3%). They have episodes of a pre-excitation during sinus rhythm. Originally, Mahaim fibres have been classified into two main groups, nodoventricular and fasciculoventricular fibres. Recent evidence from both surgery and catheter ablation has shown that the substrate for tachycardia arises due to a slowly conducting fright atrioventricular (AV) accessory pathway (AP) with decremental properties. The pre-excited tachycardia (antidromic re-entrant tachycardia) is distinctive with a left bundle branch block (LBBB) pattern, long AV interval (due to the long conduction time over the AP) and short VA interval (over the AV node). The majority of these patients do not have episodes of narrow QRS complex, due to the absence of retrograde conduction of the AP. There are several ECG features that suggest Mahaim tachycardia as a cause of LBBB pattern tachycardia: QRS axis superior or between 0 degrees and 75 degrees, QRS duration of 0.15 s or less and precordial transition in lead V4 or after. Clinically, Ebstein's anomaly is relatively common and multiple APs are also observed with an increased frequency. Small studies and cases reports have demonstrated sensitivity to various classes of AA drugs. Class IA, IC and beta-blocker may be effective in preventing tachycardias. Small surgical series have reported excellent results in patients with accessory AV connections and Mahaim fibres tachycardia. However catheter ablation offers a definitive therapy in such patients with a high success rate and minimal morbidity.

Anti-Arrhythmia Agents↗

Preliminary clinical experience with the first dual chamber pacemaker defibrillator.

The lack of specificity of VT detection is a significant shortcoming of current ICDs. In a French multicenter study, 18 patients underwent implantation of the Defender 9001 (ELA Medical), an ICD utilizing dual chamber pacing and arrhythmia detection. Over a mean follow-up period of 7.1 +/- 4.5 months, 176 tachycardia episodes recorded in the device memory were analyzed, and physician diagnosis was compared with that by the device. All 122 VT/VF episodes were correctly diagnosed, as were 51 of 53 supraventricular tachyarrhythmias. Two episodes of AF with rapid regular ventricular rates were treated as VT, and a third episode, treated as VT, could not be diagnosed with certainty. A dual chamber pacemaker defibrillator offers improved diagnostic specificity without loss of sensitivity, in addition to the hemodynamic benefit of dual chamber pacing.

Adolescent↗

Permanent left atrial pacing with a specifically designed coronary sinus lead.

This article reports the original use of a specifically designed coronary sinus (CS) lead for permanent left atrial (LA) pacing. The device is characterized by its distal end shape featuring a double 45 degree angulation, which ensures very close contact with the CS upper wall. The device was successfully implanted in 39 out of 40 patients (97.5%). The tip electrode was eventually positioned in the distal CS in 9 patients, in the middle CS in 21 patients, and close to the ostium in the proximal CS in 9 patients. The mean acute pacing threshold voltage was 0.9 +/- 0.5 V with a mean impedance of 578 +/- 144 omega as measured in unipolar distal configuration at 0.5 ms pulse width (PW). The mean A wave amplitude was 3.5 +/- 2.1 mV. Early lead dislodgment occurred only once (3%) when the tip electrode was placed in the distal or middle CS, but more often (4/9 cases) when it was placed in the proximal CS. After a mean follow-up duration of 14 +/- 8.5 months, 35 of the 39 successfully implanted leads (89.7%) were still functional in terms of LA pacing and sensing. The mean chronic pacing threshold voltage was 1.5 +/- 0.8 V and the mean A wave amplitude was 2.7 +/- 1.6 mV. There were no lead related complications. In conclusion, the device proved to be safe and highly effective for permanent LA pacing, provided the distal tip could be positioned in the distal or middle part of the CS.

Aged↗

[Accessory pathways of decremential conduction (Mahaim fibers). Treatment by endocavitary ablation; apropos of 8 cases].

Mahaim fibres are rare, right sided accessory pathways comparable with respect to certain properties (slow, decremential conduction) with "accessory atrioventricular node" located on the lateral tricuspid annulus at a distance from the Aschoff-Tawara node. Atriofascicular and atrioventricular fibres may be distinguished, both responsible for wide complex tachycardia (left bundle branch block pattern with left axis deviation). The authors report a series of 8 patients (6 women, 2 men: age: 27 +/- 11 years) without underlying cardiac disease, incapacitated by episodes of antidromic reciprocating tachycardia related to the atriofascicular fibres and justifying the indication of treatment by endocavitary ablation. In all cases, the authors tried to identify a specific potential of the Mahaim fibres on the lateral aspect of the tricuspid annulus. When the potential was recorded (7 out of the 8 cases) ablation was successful (procedure time 160 +/- 11 min; average number of applications: 9). It was not possible to identify a specific Mahaim potential in 1 case and so ablation was performed on the distal right ventricular site of insertion with no criterion of efficacy. In one woman, manipulation of the ablation catheter led to prolonged mechanical block in the Mahaim fibres, so suppressing the usual criteria of evaluation of the initial result of ablation: an early recurrence of tachycardia was observed in this case. No complications occurred during the 8 procedures. These results and those of other published cases, showed that radiofrequency ablation of Mahaim fibres is feasible with a high success rate without any immediate or long-term complications. This reliable and effective technique should form one of the therapeutic options for these invalidating junctional tachycardias.

Adolescent↗