Assessing the effect of electron density in photon dose calculations.

Photon dose calculation algorithms (such as the pencil beam and collapsed cone, CC) model the attenuation of a primary photon beam in media other than water, by using pathlength scaling based on the relative mass density of the media to water. In this study, we assess if differences in the electron density between the water and media, with different atomic composition, can influence the accuracy of conventional photon dose calculations algorithms. A comparison is performed between an electron-density scaling method and the standard mass-density scaling method for (i) tissues present in the human body (such as bone, muscle, etc.), and for (ii) water-equivalent plastics, used in radiotherapy dosimetry and quality assurance. We demonstrate that the important material property that should be taken into account by photon dose algorithms is the electron density, and not the mass density. The mass-density scaling method is shown to overestimate, relative to electrondensity predictions, the primary photon fluence for tissues in the human body and water-equivalent plastics, where 6%-7% and 10% differences were observed respectively for bone and air. However, in the case of patients, differences are expected to be smaller due to the large complexity of a treatment plan and of the patient anatomy and atomic composition and of the smaller thickness of bone/air that incident photon beams of a treatment plan may have to traverse. Differences have also been observed for conventional dose algorithms, such as CC, where an overestimate of the lung dose occurs, when irradiating lung tumors. The incorrect lung dose can be attributed to the.incorrect modeling of the photon beam attenuation through the rib cage (thickness of 2-3 cm in bone upstream of the lung tumor) and through the lung and the oversimplified modeling of electron transport in convolution algorithms. In the present study, the overestimation of the primary photon fluence, using the mass-density scaling method, was shown to be a consequence of the differences in the hydrogen content between the various media studied and water. On the other hand, the electron-density scaling method was shown to predict primary photon fluence in media other than water to within 1%-2% for all the materials studied and for energies up to 5 MeV. For energies above 5 MeV, the accuracy of the electron-density scaling method was shown to depend on the photon energy, where for materials with a high content of calcium (such as bone, cortical bone) or for primary photon energies above 10 MeV, the pair-production process could no longer be neglected. The electron-density scaling method was extended to account for pair-production attenuation of the primary photons. Therefore the scaling of the dose distributions in media other than water became dependent on the photon energy. The extended electron-scaling method was shown to estimate the photon range to within 1% for all materials studied and for energies from 100 keV to 20 MeV, allowing it to be used to scale dose distributions to media other than water and generated by clinical radiotherapy photon beams with accelerator energies from 4 to 20 MV.

Algorithms↗

Accuracy and precision of an external-marker tracking-system for radiotherapy treatments.

The purpose of this work was to determine the accuracy and precision of a real-time motion-tracking system (Osiris+) for the monitoring of external markers used on patients receiving radiotherapy treatments. Random and systematic errors in the system were evaluated for linear (1D), circular (2D) and elliptical (3D) continuous motions, and for a set of static positions offset from an origin. A Wellhofer beam data measurement system and a computer controlled platform (which could be programmed to give motion in 3D) were used to move a hemi-spherical test object. The test object had four markers of the type used on patients. Three markers were aligned in the central plane and a fourth was positioned out of plane. Errors were expressed as deviations from the planned positions at the sampled time points. The marked points on the test object were tracked for the linear motion case with a variation from the true position of less than +/-1 mm, except for two extreme situations. The variation was within +/-2 mm when the lights were dimmed and when the amplitude of the movement was +/-5.0 cm. The 2D circular motion was tracked with a standard deviation of 1 mm or less over four cycles. The sampling rates of the system were found to be 0.3-0.4 s when it was monitoring actively and 1.5-1.6 s otherwise. The recorded Osiris+ measurements of known static positions were within +/-1 mm of the value from the computer controlled platform moving the test object. The elliptical motions in 3D were tracked to +/-1 mm in two directions (Y,Z), and generally to within +/-2 mm for the third direction (X); however, specific marked points could display an error of up to 5 mm at certain positions in X. The overall displacement error for the 3D motion was +/-1 mm with a standard deviation of 2.5 mm. The system performance is satisfactory for use in tracking external marker motion during radiotherapy treatments.

Algorithms↗

A quantitative study of IMRT delivery effects in commercial planning systems for the case of oesophagus and prostate tumours.

This study focuses on understanding the impact of intensity-modulated radiotherapy (IMRT) delivery effects when applied to plans generated by commercial treatment-planning systems such as Pinnacle (ADAC Laboratories Inc.) and CadPlan/Helios (Varian Medical Systems). These commercial planning systems have had several version upgrades (with improvements in the optimization algorithm), but the IMRT delivery effects have not been incorporated into the optimization process. IMRT delivery effects include head-scatter fluence from IMRT fields, transmission through leaves and the effect of the rounded shape of the leaf ends. They are usually accounted for after optimization when leaf sequencing the "optimal" fluence profiles, to derive the delivered fluence profile. The study was divided into two main parts: (a) analysing the dose distribution within the planning-target volume (PTV), produced by each of the commercial treatment-planning systems, after the delivered fluence had been renormalized to deliver the correct dose to the PTV; and (b) studying the impact of the IMRT delivery technique on the surrounding critical organs such as the spinal cord, lungs, rectum, bladder etc. The study was performed for tumours of (i) the oesophagus and (ii) the prostate and pelvic nodes. An oesophagus case was planned with the Pinnacle planning system for IMRT delivery, via multiple-static fields (MSF) and compensators, using the Elekta SL25 with a multileaf collimator (MLC) component. A prostate and pelvic nodes IMRT plan was performed with the Cadplan/Helios system for a dynamic delivery (DMLC) using the Varian 120-leaf Millennium MLC. In these commercial planning systems, since IMRT delivery effects are not included into the optimization process, fluence renormalization is required such that the median delivered PTV dose equals the initial prescribed PTV dose. In preparing the optimum fluence profile for delivery, the PTV dose has been "smeared" by the IMRT delivery techniques. In the case of the oesophagus, the critical organ, spinal cord, received a greater dose than initially planned, due to the delivery effects. The increase in the spinal cord dose is of the order of 2-3 Gy. In the case of the prostate and pelvic nodes, the IMRT delivery effects led to an increase of approximately 2 Gy in the dose delivered to the secondary PTV, the pelvic nodes. In addition to this, the small bowel, rectum and bladder received an increased dose of the order of 2-3 Gy to 50% of their total volume. IMRT delivery techniques strongly influence the delivered dose distributions for the oesophagus and prostate/pelvic nodes tumour sites and these effects are not yet accounted for in the Pinnacle and the CadPlan/Helios planning systems. Currently, they must be taken into account during the optimization stage by altering the dose limits accepted during optimization so that the final (sequenced) dose is within the constraints.

Algorithms↗

CT dosimetry: getting the best from the adult Cristy phantom.

The use of geometrical phantoms for computed tomography (CT) dosimetry can incur errors in the calculation of effective dose due to the anatomically incorrect organ shapes and distributions, and unrepresentative body dimensions. A Monte Carlo program that makes use of an anatomically correct voxel phantom has been developed to calculate effective doses in CT and to compare with conventional dosimetric techniques. The code was validated against the latter by matching the phantom dimensions and simulating whole-body irradiation; agreement to within 6% was found. Effective doses were calculated for brain, lung, abdomen and pelvis CT scans for voxel phantom sizes corresponding to those of standard-sized adult, a teenager and 10% greater than those of standard-sized adult. Errors incurred by using the conventional techniques are minimised if the scan range is set by matching the fractions of radiosensitive organs that are irradiated directly. Under these circumstances, the conventional techniques will underestimate the dose to a 15 y old by up to 22% while the dose to a large subject is overestimated by up to 11%.

Adolescent↗

Anxiogenic profile of AM-251, a selective cannabinoid CB1 receptor antagonist, in plus-maze-naïve and plus-maze-experienced mice.

The notoriously inconsistent effects of cannabinoids on anxiety-like behaviour may be explained by recent research on CB1 receptor knockout (CB1-KO) mice suggesting that cannabinoids exert bidirectional effects via the CB1 receptor (anxiolysis) and a novel rimonabant-sensitive neuronal cannabinoid receptor (anxiogenesis). This hypothesis is supported by the anxiogenic-like profile of AM-251, an analogue of rimonabant that is a potent and selective CB1 receptor antagonist but which, unlike rimonabant, has no activity at the novel receptor. As we have previously shown that rimonabant reduces anxiety-like behaviour in test-experienced animals only, the current study assessed the effects of AM-251 (1.5-3.0 mg/kg) in male Swiss-Webster mice that were either plus-maze-naïve or had been exposed undrugged to the apparatus 24 h prior to testing. Results confirmed that prior maze experience per se significantly increases behavioural indices of anxiety without altering measures of general activity. In maze-naïve mice, the lower dose of AM-251 (1.5 mg/kg) significantly reduced % open-arm time and increased grooming while the higher dose (3.0 mg/kg) additionally reduced open-arm entries and total head-dipping, and increased closed-arm returns. These anxiogenic-like effects were observed in the absence of significant changes in general activity levels. Although AM-251 had a very similar profile in maze-experienced animals, significant drug effects on open-arm avoidance measures were precluded by experientially-induced changes in behavioural baselines (i.e. 'ceiling' effects). Nevertheless, AM-251 again significantly reduced total head-dipping and increased grooming (3.0 mg/kg) and, unlike effects in naïve animals, both doses markedly reduced time spent on the centre platform and increased time spent in the enclosed arms. Against a baseline of almost total open-arm avoidance, the pattern of behavioural change in maze-experienced mice would also be consistent with an anxiogenic-like action of AM-251. Data are discussed in relation to previous findings with rimonabant, the putative existence of a novel non-CB1 neuronal cannabinoid receptor and, more generally, the behavioural pharmacology of plus-maze 'trial 2'.

Analysis of Variance↗

Feasibility of using ultrasound for real-time tracking during radiotherapy.

This study was designed to examine the feasibility of utilizing transabdominal ultrasound for real-time monitoring of target motion during a radiotherapy fraction. A clinical Acuson 128/XP ultrasound scanner was used to image various stationary and moving phantoms while an Elekta SL25 linear accelerator radiotherapy treatment machine was operating. The ultrasound transducer was positioned to image from the outer edge of the treatment field at all times. Images were acquired to videotape and analyzed using in-house motion tracking algorithms to determine the effect of the SL25 on the quality of the displacement measurements. To determine the effect on the dosimetry of the presence of the transducer, dose distributions were examined using thermoluminescent dosimeters loaded into an Alderson Rando phantom and exposed to a 10 x 10 cm2 treatment field with and without the ultrasound transducer mounted 2.5 cm outside the field edge. The ultrasound images acquired a periodic noise that was shown to occur at the pulsing frequency of the treatment machine. Images of moving tissue were analyzed and the standard deviation on the displacement estimates within the tissue was identical with the SL25 on and off. This implies that the periodic noise did not significantly degrade the precision of the tracking algorithm (which was better than 0.01 mm). The presence of the transducer at the surface of the phantom presented only a 2.6% change to the dose distribution to the volume of the phantom. The feasibility of ultrasonic motion tracking during radiotherapy treatment is demonstrated. This presents the possibility of developing a noninvasive, real-time and low-cost method of tracking target motion during a treatment fraction.

Algorithms↗

Polymer gel measurement of dose homogeneity in the breast: comparing MLC intensity modulation with standard wedged delivery.

Polymer gel dosimetry has been used to measure the radiotherapy dose homogeneity in a breast phantom for two different treatment methods. The first 'standard' method uses two tangential wedged fields while the second method has three static fields shaped by multileaf collimators (MLCs) in addition to the standard wedged fields to create intensity modulated fields. Gel dose distributions from the multileaf modulation treatment show an improved dose uniformity in comparison to the standard treatment with a decreased volume receiving doses over 105%.

Breast Neoplasms↗

Combining dosimetry for targeted radionuclide and external beam therapies using the biologically effective dose.

It is not uncommon for a patient to receive both external beam and targeted radionuclide therapy during the course of a cancer treatment. The total dose received by the tumor and by normal tissues will therefore be subject to the contributions of both treatment modalities. However, the two treatments are generally applied independently of one another, with little attention paid to the combined effect. With the availability of patient-specific three-dimensional dosimetry for radionuclide therapies, it is pertinent now to consider the combined effect of the two treatments, and to investigate how dosimetry for this situation may be carried out. Methodology has been developed to allow a combination of dose information from the two types of therapy. The biologically effective dose (BED) has been employed to address the issue of inequivalence of biological effect of the two therapies. Dose distributions have been represented as distributions of BED, and the net effect resulting from the combination of these two therapies demonstrated through a combination of BED maps. Examples are presented of cases in which this analysis of a combined therapy provides a more favorable treatment than either therapy alone. For one patient the ratio of the mean spinal cord dose to the mean CTV dose was calculated for both an external beam therapy alone and for a combined therapy and was found to be 0.40 and 0.16, respectively.

Humans↗

Optimization of accelerator target and detector for portal imaging using Monte Carlo simulation and experiment.

Megavoltage portal images suffer from poor quality compared to those produced with kilovoltage x-rays. Several authors have shown that the image quality can be improved by modifying the linear accelerator to generate more low-energy photons. This work addresses the problem of using Monte Carlo simulation and experiment to optimize the beam and detector combination to maximize image quality for a given patient thickness. A simple model of the whole imaging chain was developed for investigation of the effect of the target parameters on the quality of the image. The optimum targets (6 mm thick aluminium and 1.6 mm copper) were installed in an Elekta SL25 accelerator. The first beam will be referred to as A16 and the second as Cu1.6. A tissue-equivalent contrast phantom was imaged with the 6 MV standard photon beam and the experimental beams with standard radiotherapy and mammography film/screen systems. The arrangement with a thin Al target/mammography system improved the contrast from 1.4 cm bone in 5 cm water to 19% compared with 2% for the standard arrangement of a thick, high-Z target/radiotherapy verification system. The linac/phantom/detector system was simulated with the BEAM/EGS4 Monte Carlo code. Contrast calculated from the predicted images was in good agreement with the experiment (to within 2.5%). The use of MC techniques to predict images accurately, taking into account the whole imaging system, is a powerful new method for portal imaging system design optimization.

Bone and Bones↗

An optimization algorithm that incorporates IMRT delivery constraints.

An intensity-modulated beam optimization algorithm is presented which incorporates the delivery constraints into the optimization cycle. The optimization algorithm is based on the quasi-Newton method of iteratively solving minimization problems. The developed algorithm iteratively corrects the incident, pencil-beam-like, fluence to incorporate the delivery constraints. In the present study, the goal of the optimization algorithm is to achieve the best deliverable radiotherapy plan, subject to the constraints of the delivery technique described by a leaf-sequencing algorithm being applied concurrently. In general, if they are applied after, rather than during, the optimization cycle, the delivery constraints associated with the IMRT technique can produce local variations up to 6% in the 'optimized' dose (i.e., distribution without applied constraints) and reduce the degree of conformity, of the dose, to the PTV region. The optimization method has been applied to three IMRT delivery techniques: dynamic multileaf (DMLC), multiple-static-field (MSF) and slice-by-slice tomotherapy (NOMOS MIMiC). The beam profiles were generated for a prostate tumour with organs at risk being the rectum, bladder and femoral heads. The optimization method described was shown to generate optimum and deliverable IMRT plans for these three delivery techniques. In the case of the DMLC and MSF the optimization converged within 3-5 iterations to a mean PTV dose of 69.60 +/- 1.34 Gy and 69.71 +/- 1.34 Gy, respectively, while for NOMOS MIMiC approximately 10 iterations were needed to obtain 69.68 +/- 1.55 Gy. In addition to this, the IMRT optimization also yielded optimum fluence profiles when clustering was performed concurrently with the leaf-sequencer. An optimum between 8 and 15 clusters of equal fluence 'intensity' was shown to establish the best compromise between the number of fluence levels and the PTV dose coverage.

Algorithms↗

Dose-position and dose-volume histogram analysis of standard wedged and intensity modulated treatments in breast radiotherapy.

The aim of this work was to evaluate the positional distribution of dose in a concise manner and to analyse dose-histogram results in tangential breast radiotherapy in 300 patients, randomized to standard wedged or intensity modulated radiotherapy (IMRT), for future correlation with clinical outcome data. A simple method for analysing the dose-position relationship in the treatment volume was used to compare the spatial distribution of dose in patients. The breast was divided into equal thirds (upper, middle and lower) and dose was assessed using three dose bands; 95-105%, >105-110% and >110% of the prescription dose. The effect of using IMRT on the dosimetry was assessed from dose-volume histogram data using the following parameters: percentage of the target volume receiving a dose less than 95%, greater than 105%, either less than 95% or greater than 105% of that prescribed; the mean dose; and the maximum dose. Doses greater than 105% were predominantly in the upper and lower regions of the breast in the standard wedged treatment. 96% of these patients received doses greater than 105% in the upper region of the breast and 70% received doses greater than 105% in the lower breast. Only 4% of patients allocated IMRT received doses greater than 105% in either region. Analysis of dose-volume histogram data showed that IMRT reduced the volume receiving a dose greater than 105% by a mean of 10.7% (p= or <0.001); the mean change in the volume receiving a dose less than 95% was 0.2% (p=0.63). Average mean plan dose was 101.6% for standard treatment and 99.6% for IMRT (p<0.001 for each compared with 100.0% ideal). The mean value of maximum dose was reduced from 111% to 106% in the group of patients randomized to IMRT. A simple method for describing the relationship between dose and position in the breast, which is helpful for the effective correlation of dosimetry and clinical effects, is reported. Further, application of IMRT to the tangential field irradiation of the breast has been demonstrated to reduce high dose regions in both volume and dose level without compromising either minimum dose coverage or mean dose delivered to the breast.

Breast Neoplasms↗

The dosimetric consequences of inter-fractional patient movement on three classes of intensity-modulated delivery techniques in breast radiotherapy.

BACKGROUND AND PURPOSE: A comparison between three classes of intensity-modulated delivery techniques was undertaken to examine the dosimetric consequences of using a multileaf collimator (MLC) reshaped on each imaged fraction as opposed to compensators designed on the first day of treatment potentially giving a treatment technique whose accuracy is thus degraded by movement. MATERIALS AND METHODS: The effects of inter-fractional patient movement for a cohort of six breast patients were studied. Five treatment techniques were evaluated, two using a compensator, two using multiple static fields (MSF) and one using a dynamic multileaf collimator (DMLC). The compensated techniques consisted of (i) the use of compensators designed on day 1 only and used each fraction thereafter and (ii) the use of a compensator redesigned for each imaged fraction. The two MSF techniques were (i) a four-field-component design and (ii) a method where the fluence interval between the MLC field components was set so they were equivalent to the compensator ('quantized' MSF-MLC). The final technique investigated was the DMLC. Plans were produced for each of the five methods and a paired t-test was used to assess the reduction in the breast volume outside the dose range 95-105% between sets of pairs of techniques. An on-line correction strategy was simulated to determine the number of treatments that required intervention. The action levels were calculated using the difference between the volume outside the dose range 95-105% calculated for treatments where the DMLC was designed on day 1 only and for each imaged fraction. Differences of greater than 2%, greater than 5% and greater than 10% were investigated. RESULTS: Thirty-five plans were evaluated for each technique. Results showed that a statistically significant mean reduction in the volume of the breast outside the dose range 95-105% could be achieved if the compensators were designed on each imaged fraction rather than on day 1 only (P=0.0045). When the comparison was made between the 'quantized' MSF-MLC and the technique where the compensators were designed on day 1 only, a statistically significant mean reduction in the volume of the breast tissue outside the dose range 95-105% was not achieved (P=0.21). Comparison of the DMLC technique to the technique where the compensators were designed on day 1 only results in a statistically significant mean reduction in the volume outside the dose range 95-105% (P=0.024). This corresponds to a mean reduction in the volume outside 95-105% dose of 1.94%. The 2% action level showed the greatest reduction in the volume outside 95-105% dose and intervention was only required in approximately one-third of the treatments investigated. CONCLUSIONS: Redesigning MSFs for each imaged fraction did not provide a statistically significant mean reduction in the volume outside the dose range 95-105%. However, using the DMLC technique creates a statistically significant mean reduction in the volume outside the dose range 95-105%.

Breast Neoplasms↗

Analysis of the effects of the delivery technique on an IMRT plan: comparison for multiple static field, dynamic and NOMOS MIMiC collimation.

The process of delivering an IMRT treatment may involve various beam-modifying techniques such as multileaf collimators (MLCs), the NOMOS MIMiC, blocks, wedges, etc. In the case of the MLC, the spatial/temporal variation of the position of the leaves and diaphragms in the beam allows the delivery of modulated beam profiles either by the multiple-static-field (MSF) method or by the dynamic multileaf collimator (DMLC) method. The constraints associated with the IMRT delivery technique are usually neglected in the process of obtaining the 'optimal' inverse treatment plan. Consequently, dose optimization may be significantly reduced when the 'optimal' beam profiles are converted to leaf/diaphragm positions via a leaf-sequencing interpreter. The paper presented here assesses the effects on the optimum treatment plan of the following leaf-sequencing algorithms: MSF, DMLC and NOMOS MIMiC. The results obtained suggest that the delivery of an 'optimum' plan produces an overdosage of the PTV region due to various factors such as leaf/diaphragm transmission effects, head-scatter and phantom-scatter contributions. The overdosage observed for a cohort of ten patients was 2.5, 3.7 and 5.7%, respectively, for the DMLC, MSF and NOMOS MIMiC, after normalizing the delivered fluence to account for IMRT effects (using the method of Convery et al (Convery D J, Cogrove V P and Webb S 2000 Proc. 13th Int. Conf. on Computers in Radiotherapy (Heidelberg, 2000)) such as to obtain 70 Gy at the isocentre. The IMRT techniques DMLC, MIMiC and MSF were compared for the organs at risk: rectum, bladder, and left and right femoral heads.

Algorithms↗

A simulation of the effects of set-up error and changes in breast volume on conventional and intensity-modulated treatments in breast radiotherapy.

The effect of interfractional patient movement on dosimetry has been investigated for breast radiotherapy. Errors in patient set-up and changes in breast volume were simulated individually to determine how each contributes to the total dosimetric error. Two treatment techniques were investigated: a conventional treatment and an intensity-modulated treatment delivered using compensators. Six patients were investigated and anterior-posterior (AP) and superior-inferior (SI) displacements were simulated by displacing the isocentre in both directions by 2, 5 and 10 mm. A model of the breast was developed from the six patients to simulate changes in breast volume. In this model, the breast was described as a set of semi-ellipses. The volume of the breast was changed by varying the magnitude of the semi-major and semi-minor axes. Anisotropic changes in breast volume were also investigated. The dosimetric error was evaluated for each dose plan by calculating the volume outside the 95-105% dose range resulting from the simulations. A number of parameters describing the size and shape of the breast were also investigated to determine whether a susceptibility of outline sets to interfractional patient movement could be predicted. A parameter describing the increase in the breast volume outside the 95-105% dose range was calculated for AP a

Breast↗

An intercomparison of IMRT delivery techniques: a case study for breast treatment.

Intensity-modulated radiotherapy beams can be delivered using a multileaf collimator by one of two methods: either by superposition of a series of multiple-static fields, or by moving the collimators while the beam is on to produce 'dynamically' modulated beams. The leaf trajectories in this dynamic mode are given by a series of linear steps between control points defining each collimator position at known intervals throughout an exposure. The complexity of the resulting modulation is limited in the first case by the number of fields superposed and in the second case by the number of control points defined. Results are presented for an experimental study that investigates the effect of changing both the number of fields for the multiple-static technique, and the number of control points for a dynamic 'close-in' technique. All deliveries studied are clinical intensity-modulated breast fields. The effect of using a universal wedge in conjunction with the multileaf collimator is also studied, together with a comparison of the relative efficiency, time taken and the absolute dosimetric accuracy of the various delivery options. It is shown that all delivery techniques produce equivalent dose distributions when using 15 control points, with 10 control points being sufficient to produce an adequate breast compensator distribution. Except for the case of a four-control-point dynamic delivery, the universal wedge makes no significant difference to the dose distribution. However, it makes the delivery less efficient. The close-in interpreter consistently produces deliveries that are more efficient than the more conventional sliding-window technique and faster than the multiple-static-field technique. Finally the close-in technique is compared to the more 'standard' leaf-sweep technique and shown to be equivalent.

Breast Neoplasms↗

Sampling considerations for intensity modulated radiotherapy verification using electronic portal imaging.

A model has been developed to describe the sampling process that occurs when intensity modulated radiotherapy treatments (delivered with a multileaf collimator) are imaged with an electronic portal imaging device that acquires a set of frames with a finite dead-time between them. The effects of the imaging duty cycle and frame rate on the accuracy of dosimetric verification have been studied. A frame interval of 1 s with 25%, 50% and 75% duty cycle, and a 50% duty cycle with frame intervals of 1, 2, 4, 8, and 16 s have been studied for a smoothly varying hemispherical intensity profile, and a 50% duty cycle with frame intervals of 1, 2, 4, and 8 s for a pixellated distribution. In addition an intensity modulated beam for breast radiotherapy has been modeled and imaged for 0.33 s frame time and 1, 2, and 3 s frame separation. The results show that under sparse temporal sampling conditions, errors of the order of 10% may ensue and occur with an oscillatory pattern. For the beams studied, imaging with a 1 or 2 s frame interval resulted in small errors at the 1%-2% level, for all duty cycles shown.

Breast↗