Search PubMed⌕ Search

Biomedical subjects

P Kolm

Publications and source records attributed to P Kolm.

58 records · Page 4Linked to original sources

Are strokes predictable with noninvasive methods: a five-year follow-up of 303 unoperated patients.

To determine the correlation between the degree of internal carotid arterial stenosis demonstrated by noninvasive tests and the risk of subsequent stroke, 303 consecutive patients who underwent cerebrovascular evaluation with the Hokanson ultrasonic arteriograph were reviewed retrospectively. Ninety percent of the patients were followed up for 5 years or until the time of death. Stroke occurred in 41 (13.5%) patients. There was a significant correlation (p = 0.04) between the incidence of stroke and severity of disease: greater than or equal to 50% stenosis (19%), 0% to 49% stenosis (11%), and no stenosis (10%). Stroke as a presenting complaint carried the highest risk of subsequent neurologic defect (24%), but the risk in patients without symptoms was appreciable (15%). Life-table analysis indicated that the incidence of stroke was low (less than 3%) in the asymptomatic and nonhemispheric group during the first 2 years after evaluation when the degree of stenosis was less than 50%. Thereafter, the stroke rate increased. Half the deaths were due to myocardial infarction; the risk of death from cardiac causes was doubled in patients with greater than 50% stenosis. It is concluded that the demonstration of hemodynamically significant stenosis does select a group of patients at increased risk for subsequent stroke and myocardial infarction, but lesser degrees of stenosis do not exclude future neurologic events.

Actuarial Analysis↗

Sperm function assays and their predictive value for fertilization outcome in IVF therapy: a meta-analysis.

The prevalence of male infertility and the availability of new, highly successful therapeutic options make the testing of sperm functional competence mandatory. An objective, outcome-based examination of the validity of the currently available assays was performed based upon the results obtained from 2906 subjects evaluated in 34 prospectively designed, controlled studies. The aim was carried out through a meta-analytical approach that examined the predictive value of four categories of sperm functional assays: computer-aided sperm motion analysis (CASA); induced-acrosome reaction testing; sperm penetration assay (SPA); and sperm-zona pellucida binding assays for IVF outcome. Results demonstrated a high predictive power of the sperm-zona pellucida binding and the induced-acrosome reaction assays for fertilization outcome. On the other hand, the findings indicated a poor clinical value of the SPA as predictor of fertilization and a real need for standardization and further investigation of the potential clinical utility of CASA systems. This analysis points out to limitations of the current tests and the need for standardization of methodologies and provides objective evidence on which clinical management and future research can be based.

Acrosome Reaction↗

A comparison of infusion devices at 1 ml/hr.

Delivery of medications by some infusion devices is irregular. This study investigated instantaneous flow in several infusion devices set at a rate of 1 ml/hr. The following devices were tested: Infusion Pumps: IMED 956A, IVAC 570, IVION "Kids Pump." Syringe Pumps: Medfusion, Baxter, Baxter OR. Tests were performed using a Bio-Tek Infusion Device Analyzer (Model IDA-1). Instantaneous flow rate was defined as Q1/T1 where: Q=sample volume and T=time required to deliver sample volume. The infusion devices were received directly from their respective manufacturers and had not seen clinical service before testing. The units were fully charged and were tested while on AC power. The tests were conducted by the authors, using standard infusion sets and commercially prepared 5% dextrose and 0.45% sodium chloride solution. Each pump was tested for several hours and multiple trials were performed on each pump. The infusion pumps, IMED, IVION, and IVAC all demonstrated deviations from the desired flow rate. The IVAC pump had a greater fluctuation in flow from the set value of 1 ml/hr (p less than 0.02). Variances from mean +/- standard error for each device are shown in parenthesis. IMED 965A (0.005+/-0.014), IVION Kid's Pump (0.002+/-0.009), IVAC 570 (0.001+/-0.006). The Baxter syringe pump (0.002+/-0.009) also had a wide variance in flow. The Baxter OR (0.001+/-0.005) and the Medfusion (0.001+/-0.008) syringe pumps maintained the most consistent flow and showed less variance than the other devices tested.(ABSTRACT TRUNCATED AT 250 WORDS)

Drug Therapy↗