Search PubMed⌕ Search

Biomedical subjects

P K Zysset

Publications and source records attributed to P K Zysset.

12 recordsLinked to original sources

Compliance of the L5-S1 spinal unit: a comparative study between an unconstrained and a partially constrained system.

A comparison between an unconstrained and a partially constrained system for in vitro biomechanical testing of the L5-S1 spinal unit was conducted. The objective was to compare the compliance and the coupling of the L5-S1 unit measured with an unconstrained and a partially constrained test for the three major physiological motions of the human spine. Very few studies have compared unconstrained and partially constrained testing systems using the same cadaveric functional spinal units (FSUs). Seven human L5-S1 units were therefore tested on both a pneumatic, unconstrained, and a servohydraulic, partially constrained system. Each FSU was tested along three motions: flexion-extension (FE), lateral bending (LB) and axial rotation (AR). The obtained kinematics on both systems is not equivalent, except for the FE case, where both motions are similar. The directions of coupled motions were similar for both tests, but their magnitudes were smaller in the partially constrained configuration. The use of a partially constrained system to characterize LB and AR of the lumbosacral FSU decreased significantly the measured stiffness of the segment. The unconstrained system is today's "gold standard" for the characterization of FSUs. The selected partially constrained method seems also to be an appropriate way to characterize FSUs for specific applications. Care should be taken using the latter method when the coupled motions are important.

Aged↗

A finite element model of the L5-S1 functional spinal unit: development and comparison with biomechanical tests in vitro.

The main objective of this work is to develop a three-dimensional finite element model of the L5-S1 segment that is able to simulate its passive mobility measured in vitro. Due to their limited role in segment mobility, an isotropic linear elastic constitutive law was used for cartilage, cancellous and cortical bone. The intervertebral disk ground substance was modeled with a non-linear hyperelastic polynomial law. Fibers of the disk, as well as ligaments, were modeled with piecewise linear springs. Flexion-extension, axial rotation, and lateral bending torques were applied to the model. A comparison with the experimental results obtained on the same segment for these three major motions was conducted. The compliance of the segment subjected to pure torques was found to be similar between numerical and experimental results for all major motions. Coupled motions and translations were also similar, even in their amplitude. For lateral bending, the normal coupled motions originate from the geometry of the disk and not from the facet geometry.

Aged↗

Age, gender, and bone lamellae elastic moduli.

To enhance preventative and therapeutic strategies for metabolic bone diseases and bone fragility disorders, we began to explore the physical properties of bone tissue at the cellular level. Proximal femurs were harvested from 27 cadavera (16 male and 11 female) for in vitro measurement of the mechanical properties. We measured the variations in lamellar-level elastic modulus and hardness in human bone as a function of age and gender to identify microstructural properties responsible for age and gender-related reductions in the mechanical integrity. The lateral femoral necks were examined, and age, gender, height, body mass, and body mass index were not found to correlate with lamellar-level elastic modulus or hardness. This result was consistent for osteonal, interstitial, and trabecular tissue. These data suggest that increased bone mass maintenance, known to occur in heavier individuals, is not accompanied by increases in the lamellar-level elastic modulus or hardness. The independence of elastic modulus and hardness from age and gender suggests that age and gender-related decreases in mechanical integrity do not involve alterations in elastic modulus or hardness of the extracellular matrix. Lamellar-level ultimate, fatigue, and fracture toughness properties should also be investigated. Other factors, such as tissue mass and organization, may also contribute to age and gender-related decreases in the mechanical integrity.

Adult↗

Heterogeneity of bone lamellar-level elastic moduli.

Advances in our ability to assess fracture risk, predict implant success, and evaluate new therapies for bone metabolic and remodeling disorders depend on our understanding of anatomically specific measures of local tissue mechanical properties near and surrounding bone cells. Using nanoindentation, we have quantified elastic modulus and hardness of human lamellar bone tissue as a function of tissue microstructures and anatomic location. Cortical and trabecular bone specimens were obtained from the femoral neck and diaphysis, distal radius, and fifth lumbar vertebra of ten male subjects (aged 40-85 years). Tissue was tested under moist conditions at room temperature to a maximum depth of 500 nm with a loading rate of 10 nm/sec. Diaphyseal tissue was found to have greater elastic modulus and hardness than metaphyseal tissues for all microstructures, whereas interstitial elastic modulus and hardness did not differ significantly between metaphyses. Trabecular bone varied across locations, with the femoral neck having greater lamellar-level elastic modulus and hardness than the distal radius, which had greater properties than the fifth lumbar vertebra. Osteonal, interstitial, and primary lamellar tissues of compact bone had greater elastic moduli and hardnesses than trabecular bone when comparing within an anatomic location. Only femoral neck interstitial tissue had a greater elastic modulus than its osteonal counterpart, which suggests that microstructural distinctions can vary with anatomical location and may reflect differences in the average tissue age of cortical bone or mineral and collagen organization.

Adult↗

Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur.

The mechanical properties of bone tissue are determined by composition as well as structural, microstructural and nanostructural organization. The aim of this study was to quantify the elastic properties of bone at the lamellar level and compare these properties among osteonal, interstitial and trabecular microstructures from the diaphysis and the neck of the human femur. A nanoindentation technique with a custom irrigation system was used for simultaneously measuring force and displacement of a diamond tip pressed 500 nm into the moist bone tissue. An isotropic elastic modulus was calculated from the unloading curve with an assumed Poisson ratio of 0.3, while hardness was defined as the maximal force divided by the corresponding contact area. The elastic moduli ranged from 6.9 +/- 4.3 GPa in trabecular tissue from the femoral neck of a 74 yr old female up to 25.0 +/- 4.3 GPa in interstitial tissue from the diaphyseal cortex of a 69 yr old female. The mean elastic modulus was found to be significantly influenced by the type of lamella (p < 10(-6)) and by donor (p < 10(-6)). The interaction between the type of lamella and the donor was also highly significant (p < 10(-6)). Hardness followed a similar distribution as elastic modulus among types of lamellae and donor, but with lower statistical contrast. It is concluded that the nanostructure of bone tissue must differ substantially among lamellar types, anatomical sites and individuals and suggests that tissue heterogeneity is of potential importance in bone fragility and adaptation.

Aged↗

A global relationship between trabecular bone morphology and homogenized elastic properties.

An alternative concept of the relationship between morphological and elastic properties of trabecular bone is presented and applied to human tissue from several anatomical locations using a digital approach. The three-dimensional morphology of trabecular bone was assessed with a microcomputed tomography system and the method of directed secants as well as the star volume procedure were used to compute mean intercept length (MIL) and average bone length (ABL) of 4 mm cubic specimens. Assuming isotropic elastic properties for the trabecular tissue, the general elastic tensors of the bone specimens were determined using the homogenization method and the closest orthotropic tensors were calculated with an optimization algorithm. The assumption of orthotropy for trabecular bone was found to improve with specimen size and hold within 6.1 percent for a 4 mm cube size. A strong global relationship (r2 = 0.95) was obtained between fabric and the orthotropic elastic tensor with a minimal set of five constants. Mean intercept length and average bone length provided an equivalent power of prediction. These results support the hypothesis that the elastic properties of human trabecular bone from an arbitrary anatomical location can be estimated from an approximation of the anisotropic morphology and a prior knowledge of tissue properties.

Adult↗

Mechanical properties of human trabecular bone lamellae quantified by nanoindentation.

Improved preventive and therapeutic strategies for skeletal diseases such as osteoporosis rely on a better understanding of the mechanical properties of trabecular bone and their influence on cell mediated adaptation processes. The mechanical properties of trabecular bone are determined by composition as well as structural (trabecular architecture), microstructural (trabecular packets) and nanostructural (lamellae) organization. Density is the major predictor of the mechanical properties of trabecular structures and has been extended to the concept of fabric to include architectural anisotropy and improve even further the power of prediction. Recent advances in QCT and MRI technologies allow for precise assessment of 3D trabecular architecture and the mechanical consequences of structural changes can be increasingly well quantified by the means of computational methods. While single trabeculae have been tested using various techniques with contrasting results, little is known about the intrinsic mechanical properties of trabecular bone lamellae on which these computational methods rely. For instance, water and mineral content have a significant effect on the elastic, viscous, yield and postyield properties of bone tissue. In addition, collagen fiber orientation affects the mechanics of single remodeling units. Variations in composition and organization determined by age, accumulated damage or disease may therefore reduce the mechanical integrity of trabecular bone and deserve more attention. The aim of this work was to utilize a nanoindentation technique to quantify elastic modulus and hardness of human trabecular bone lamellae.

Aged↗

A 3D damage model for trabecular bone based on fabric tensors.

Motivated by the role of damage in normal and pathological conditions of trabecular bone, a novel 3D constitutive law was developed that describes anisotropic elasticity and the rate-independent degradation in mechanical properties resulting from the growth of cracks or voids in the trabecular tissue. The theoretical model was formulated within the framework of continuum damage mechanics and based on two fabric tensors characterizing the local trabecular morphology. Experimental validation of the model was achieved by uniaxial and torsional testing of waisted bovine trabecular bone specimens. Strong correlations were found between cumulated permanent strain, reduction in elastic moduli and nonlinear postyield stress, which support the hypothesis that these variables reflect the same underlying damage process.

Animals↗

Morphology-mechanical property relations in trabecular bone of the osteoarthritic proximal tibia.

Alteration of morphologic and mechanical properties of trabecular bone in the osteoarthritic proximal tibia may be a contributing factor in tibial component loosening. To explore this issue, the authors performed tissue property measurements, morphologic analysis, and mechanical testing of subchondral, epiphyseal, and metaphyseal trabecular bone specimens retrieved from six human proximal tibias exhibiting a range of medial unicondylar osteoarthritic degeneration. Apparent density in the proximal tibia was altered according to varus misalignment and medial subluxation associated with medial osteoarthritis of the knee. In subchondral bone, a decrease in tissue mineralization contributed to a significant reduction in axial mechanical properties with degenerative disease (P < .0005). In epiphyseal and metaphyseal bone, trabecular thickness and the number of trabeculae increased linearly with volume fraction, providing a power law relationship between axial elastic modulus and apparent density (R2 = .84). Average elastic properties of the tibial epiphysis and metaphysis were not reduced by degenerative disease (P < .05). The results suggest that absolute minimization of tibial resection might not be an optimal strategy for tibial component fixation and that mechanical properties of the tibial resection surface are more homogeneous in planes parallel to the joint surface than in a plane normal to the longitudinal axis of the tibia.

Aged↗

Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component.

A numerical model of a femoral total hip component based on the finite element method is developed to evaluate the relative micromotions at the bone-implant interface and the stress distribution in the femoral bone. The interface is modelled as unilateral contact involving Coulomb's dry friction between the bone and the implant. In addition, the model includes inhomogeneity, anisotropy as well as plasticity of both cortical and spongious bones. An automatic data processor coupled to a three-dimensional mesh generator is designed to extract cortical bone geometry and inhomogeneous distribution of trabecular bone density from data obtained with quantitative computed tomography (QCT). A preliminary application is conducted to evaluate the mechanical behaviour of an existing bone-prosthesis structure for two typical loadings: a load simulating the single leg stance and a load simulating the stair climbing stance. The obtained results are subdivided in two parts. Firstly, the characterization of stress transfer and micromotions at the bone-stem interface. The peak value of the shear micromotions reaches 600 microns in the proximal medial region with a friction coefficient equal to 0.6. An analysis of the influence of the friction coefficient reveals that the shear and distractive micromotions as well as the shear and normal stresses depend strongly on this coefficient. Secondly, the representation of stresses in the femoral bone. Determination of complementary invariants such as the hydrostatic pressure, the deviatoric stress and anisotropic stresses brings additional insights in the evaluation of the stress field in the femoral bone.

Activities of Daily Living↗

Biomechanics of fracture risk prediction of the hip and spine by quantitative computed tomography.

In this review, we have made use of some simple engineering concepts to summarize current efforts relating QCT measures to bone density and strength. From a variety of in vitro experiments on cadaveric vertebrae and femora, it is evident that both apparent and ash densities are strong linear functions of QCT measures, with coefficients of determination ranging from 0.49 to 0.90 and relative errors from 44.9% to 7.1%. QCT data also can be used (with somewhat less confidence) to determine the compressive modulus (R2s from 0.36 to 0.68, relative errors from 45.0% to 35.5%) and compressive strength (R2s from 0.58 to 0.70, relative errors from 56.5% to 39.9%) of trabecular bone from the proximal femur and vertebral body. In cortical bone, material properties are only correlated weakly with QCT measures. Experiments designed to relate QCT data to failure loads for the proximal femur and vertebral body have been remarkably successful. Coefficients of determination have ranged from 0.32 to 0.93, with relative errors from 31.1% to 13.9%. However, when the in vitro failure loads determined in these experiments are compared against available estimates of in vivo loads on the spine and hip, it is apparent, at least in the elderly, that in vivo loads are relatively close to those that cause fracture in vitro. To assess the possibility of developing QCT-based clinical predictors of fracture risk for individual patients, we have introduced the concept factor of risk often used in engineering design to account for uncertainties in estimates of service loads and component strength. The factor of risk for a particular loading condition is defined as the ratio of expected service loads to the known failure loads. To extend this concept to densitometric fracture risk prediction in vivo, it is important to recognize that densitometric data must not only be used to predict the ultimate load carrying capacity of the region of interest, but that this ultimate load must then be compared to the forces expected in vivo under comparable loading conditions. One difficulty with this approach is that little is known about the in vivo forces that are associated with atraumatic age-related fractures of the hip and vertebrae and even less about the forces applied to the hip and spine during traumatic events such as falls. However, from available estimates of in vivo loads during bending and lifting, it is apparent that in the elderly, factors of risk for the spine can easily approach 1.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗