Search PubMedSearch

Biomedical subjects

P K Hansma

Publications and source records attributed to P K Hansma.

At least 19 recordsLinked to original sources

Oriented, active Escherichia coli RNA polymerase: an atomic force microscope study.

Combining a system for binding proteins to surfaces (Sigal, G. B., C. Bamdad, A. Barberis, J. Strominger, and G. M. Whitesides. 1996. Anal. Chem. 68:490-497) with a method for making ultraflat gold surfaces (Hegner, M., P. Wagner, and G. Semenza. 1993. Surface Sci. 291:39-46 1993) has enabled single, oriented, active Escherichia coli RNA polymerase (RNAP) molecules to be imaged under aqueous buffer using tapping-mode atomic force microscopy (AFM). Recombinant RNAP molecules containing histidine tags (hisRNAP) on the C-terminus were specifically immobilized on ultraflat gold via a mixed monolayer of two different omega-functionalized alkanethiols. One alkanethiol was terminated in an ethylene-glycol (EG) group, which resists protein adsorption, and the other was terminated in an N-nitrilotriacetic acid (NTA) group, which binds the histidine tag through two coordination sites with a nickel ion. AFM images showed that these two alkanethiols phase-segregate. Specific binding of the hisRNAP molecules was followed in situ by injecting proteins directly into the AFM fluid cell. The activity of the hisRNAP bound to the NTA groups was confirmed with a 42-base circular single-stranded DNA template (rolling circle), which the RNAP uses to produce huge RNA transcripts. These transcripts were imaged in air after the samples were rinsed and dried, since RNA also has low affinity for the EG-thiol and cannot be imaged under the buffers we used.

DNA, Single-Stranded

Molecular cloning and characterization of lustrin A, a matrix protein from shell and pearl nacre of Haliotis rufescens.

A specialized extracellular matrix of proteins and polysaccharides controls the morphology and packing of calcium carbonate crystals and becomes occluded within the mineralized composite during formation of the molluscan shell and pearl. We have cloned and characterized the cDNA coding for Lustrin A, a newly described matrix protein from the nacreous layer of the shell and pearl produced by the abalone, Haliotis rufescens, a marine gastropod mollusc. The full-length cDNA is 4,439 base pairs (bp) long and contains an open reading frame coding for 1,428 amino acids. The deduced amino acid sequence reveals a highly modular structure with a high proportion of Ser (16%), Pro (14%), Gly (13%), and Cys (9%). The protein contains ten highly conserved cysteine-rich domains interspersed by eight proline-rich domains; a glycine- and serine-rich domain lies between the two cysteine-rich domains nearest the C terminus, and these are followed by a basic domain and a C-terminal domain that is highly similar to known protease inhibitors. The glycine- and serine-rich domain and at least one of the proline-rich domains show sequence similarity to proteins of two extracellular matrix superfamilies (one of which also is involved in the mineralized matrixes of bone, dentin, and avian eggshell). The arrangement of alternating cysteine-rich domains and proline-rich domains is strikingly similar to that found in frustulins, the proteins that are integral to the silicified cell wall of diatoms. Its modular structure suggests that Lustrin A is a multifunctional protein, whereas the occurrence of related sequences suggest it is a member of a multiprotein family.

Amino Acid Sequence

Escherichia coli RNA polymerase activity observed using atomic force microscopy.

Fluid tapping-mode atomic force microscopy (AFM) was used to observe Escherichia coli RNA polymerase (RNAP) transcribing two different linear double-stranded (ds) DNA templates. The transcription process was detected by observing the translocation of the DNA template by RNAP on addition of ribonucleoside 5'-triphosphates (NTPs) in sequential AFM images. Stalled ternary complexes of RNAP, dsDNA and nascent RNA were adsorbed onto a mica surface and imaged under continuously flowing buffer. On introduction of all four NTPs, we observed some DNA molecules being pulled through the RNAP, some dissociating from the RNAP and others which did not move relative to the RNAP. The transcription rates were observed to be approximately 0.5-2 bases/s at our NTP concentrations, approximately 5 microM. The RNA transcripts were not unambiguously imaged in fluid. However, in experiments using a small single-stranded (ss) circular DNA template, known as a rolling circle, transcripts up to 1 or 2 microns long could be observed with tapping mode AFM once the samples were dried and imaged in air. This confirmed our observations of the transcriptional activity of RNAP adsorbed onto mica. This work illustrates that the development of tapping-mode in fluid has made it possible to use AFM to follow biological processes at the molecular level and get new insights about the variability of activity of individual molecules bound to a surface.

Aluminum Silicates

Visualization of poly(A)-binding protein complex formation with poly(A) RNA using atomic force microscopy.

Poly(A)-binding protein (PABP) is an RNA-binding protein that binds specifically to the poly(A) tail of messenger RNAs in eukaryotes. The PABP/poly(A) tail complex has been implicated as being important in promoting the efficient initiation of translation as well as in maintaining the integrity of the mRNA. PABP binds poly(A) cooperatively with a packing density of one PABP molecule per 25 adenosine residues. We have investigated the complexes formed between purified PABP and poly(A) RNA using atomic force microscopy (AFM). PABP alone was observed to be primarily in a monomer form with a height of 1.0 +/- 0.2 nm. Following binding to poly(A), PABP appeared to be present in variable size complexes that bound lengthwise along the RNA. This size of the PABP/poly(A) complex appeared to be maximal, suggesting that PABP binding to poly(A) may be self-limiting. Poly(A) RNA alone appeared to contain a knob-like structure that largely disappeared once PABP was bound. The use of AFM has therefore provided potential new insights into the complexes formed by this RNA-binding protein.

Aluminum Silicates

Modification of calcite crystal growth by abalone shell proteins: an atomic force microscope study.

A family of soluble proteins from the shell of Haliotis rufescens was introduced over a growing calcite crystal being scanned in situ by an atomic force microscope (AFM). Atomic step edges on the crystal surface were altered in shape and speed of growth by the proteins. Proteins attached nonuniformly to the surface, indicating different interactions with crystallographically different step edges. The observed changes were consistent with the habit modification induced by this family of proteins, as previously observed by optical microscopy. To facilitate further studies in this area, AFM techniques and certain AFM imaging artifacts are discussed in detail.

Animals

Imaging the internal and external pore structure of membranes in fluid: TappingMode scanning ion conductance microscopy.

We have constructed a combined TappingMode atomic force microscope and scanning ion conductance microscope. The design is based on a bent glass pipette that acts as both the force sensor and conductance probe. Measuring the pipette deflection allows more stable feedback than possible with previous versions of the scanning ion conductance microscope. Using this microscope, we have imaged synthetic membranes in both contact and tapping modes under fluid. Although contact mode operation is possible, we found that our microscope provided higher contrast and less apparent sample damage in the topographic and ionic conductance images in the tapping mode.

Ions

Measuring the viscoelastic properties of human platelets with the atomic force microscope.

We have measured force curves as a function of the lateral position on top of human platelets with the atomic force microscope. These force curves show the indentation of the cell as the tip loads the sample. By analyzing these force curves we were able to determine the elastic modulus of the platelet with a lateral resolution of approximately 100 nm. The elastic moduli were in a range of 1-50 kPa measured in the frequency range of 1-50 Hz. Loading forces could be controlled with a resolution of 80 pN and indentations of the platelet could be determined with a resolution of 20 nm.

Biophysical Phenomena

Protein tracking and detection of protein motion using atomic force microscopy.

Height fluctuations over three different proteins, immunoglobulin G, urease, and microtubules, have been measured using an atomic force microscope (AFM) operating in fluid tapping mode. This was achieved by using a protein-tracking system, where the AFM tip was periodically repositioned above a single protein molecule (or structure) as thermal drifting occurred. Height (z-piezo signal) data were taken in 1 - or 2-s time slices with the tip over the molecule and compared to data taken on the support. The measured fluctuations were consistently higher when the tip was positioned over the protein, as opposed to the support the protein was adsorbed on. Similar measurements over patches of an amphiphile, where the noise was identical to that on the support, suggest that the noise increase is due to some intrinsic property of proteins and is not a result of different tip-sample interactions over soft samples. The orientation of the adsorbed proteins in these preliminary studies was not known; thus it was not possible to make correlations between the observed motion and specific protein structure or protein function beyond noting that the observed height fluctuations were greater for an antibody (anti-bovine IgG) and an enzyme (urease) than for microtubules.

Animals

Imaging soft samples with the atomic force microscope: gelatin in water and propanol.

We have imaged mica coated with thin gelatin films in water, propanol, and mixtures of these two liquids by atomic force microscopy (AFM). The elastic modulus (Young's modulus) can be tuned from 20 kPa to more than 0.1 GPa depending on the ratio of propanol to water. The resolution is best in pure propanol, on the order of 20 nm, and becomes worse for the softer samples. The degradation in resolution can be understood by considering the elastic indentation of the gelatin caused by the AFM tip. This indentation becomes larger and thus the contact area becomes larger the softer the sample is. Therefore this study may be used to estimate the resolution to be expected with an AFM on other soft samples, such as cells. Nondestructive imaging was possible only by imaging at forces < 1 nN. This was difficult to achieve in contact mode because of drift in the zero load deflection of the cantilever, supposedly caused by temperature drift, but straightforward in tapping mode.

1-Propanol

Applications for atomic force microscopy of DNA.

Tapping mode atomic force microscopy (AFM) of DNA in propanol, dry helium, and aqueous buffer each have specific applications. Resolution is best in propanol, which precipitates and immobilizes the DNA and provides a fluid imaging environment where adhesive forces are minimized. Resolution on exceptional images of DNA appears to be approximately 2 nm, sufficient to see helix turns in detail, but the smallest substructures typically seen on DNA in propanol are approximately 6-10 nm in size. Tapping AFM in dry helium provides a convenient way of imaging such things as conformations of DNA molecules and positions of proteins on DNA. Images of single-stranded DNA and RecA-DNA complexes are presented. In aqueous buffer DNA molecules as small as 300 bp have been imaged even when in motion. Images are presented of the changes in shape and position of circular plasmid DNA molecules.

Bacteriophage lambda

Imaging real-time neurite outgrowth and cytoskeletal reorganization with an atomic force microscope.

An atomic force microscope was used to image the morphology and structural reorganization of rat NIH/3T3 fibroblasts and PC-12 cells growing in petri dishes. NIH/3T3 fibroblasts had a uniform morphology and an extensive cytoskeletal network. Cell thickness varied from approximately 2-3 microns above the nucleus to approximately 20-30 nm over the distal processes, and cytoskeletal fibers as small as 30 nm wide were observed. Imaging over an extended period of time showed a limited degree of cytoskeletal reorganization. Localized force dissection did not induce significant retraction of cellular processes and immediate cell death. Differentiating PC-12 cells with a neuronal phenotype had a nonuniform morphology, abundant cytoskeletal elements, neuritic processes, and growth cones. The cell thickness varied from approximately 5-8 microns over the nucleus to approximately 100-500 nm over the neuritic processes; growth cones approximately 50-700 nm wide and end structures approximately 30-150 nm wide were visible. Repeated imaging showed reorganization of the growth cone, especially the appearance and disappearance of beadlike features and fibrous organization. Thus an atomic force microscope can be used for high-resolution real-time studies of the dynamic subcellular mechanisms that drive cell behavior.

3T3 Cells

Direct observation of enzyme activity with the atomic force microscope.

The height fluctuations on top of the protein lysozyme adsorbed on mica were measured locally with an atomic force microscope operated in tapping mode in liquid. Height fluctuations of an apparent size of 1 nanometer that lasted for about 50 milliseconds were observed over lysozyme molecules when a substrate (oligoglycoside) was present. In the presence of the inhibitor chitobiose, these height fluctuations decreased to the level without the oligoglycoside. The most straightforward interpretation of these results is that the height fluctuations correspond to the conformational changes of lysozyme during hydrolysis. It is also possible, however, that the height fluctuations are, at least in part, the result of a different height or elasticity of the transient complex of lysozyme plus the substrate.

Adsorption

Motion and enzymatic degradation of DNA in the atomic force microscope.

The dynamics and enzymatic degradation of single DNA molecules can now be observed with the atomic force microscope. A combination of two advances has made this possible. Tapping in fluid has reduced lateral forces, which permits the imaging of loosely adsorbed molecules; and the presence of nickel ions appears to form a relatively stable bridge between the negatively charged mica and the negatively charged DNA phosphate backbone. Continuous imaging shows DNA motion and the process of DNA degradation by the nuclease DNase I. It is possible to see DNase degradation of both loosely adsorbed and tightly adsorbed DNA molecules. This method gives images in aqueous buffer of bare, uncoated DNA molecules with lengths of only a few hundred base pairs, or approximately 100 nm in length.

Adsorption

Structures of large T antigen at the origin of SV40 DNA replication by atomic force microscopy.

For inorganic crystals such as calcite (CaCO3), Atomic Force Microscopy (AFM) has provided surface structure at atomic resolution (Ohnesorge and Binnig, 1993). As part of a broad effort to obtain high resolution for an individual protein or protein assembly (Binnig et al., 1986; Rugar and Hansma, 1990; Radmacher et al., 1992), we applied AFM to study the ATP-dependent double hexamer of SV40 large T antigen, which assembles around the viral origin of DNA replication. Multimeric mass has been determined in two-dimensional projected images by Scanning Transmission Electron Microscopy (STEM) (Mastrangelo et al., 1989). By AFM, if the DNA-protein preparation has been stained positively by uranyl acetate, the contour at the junction between hexamers is visible as a cleft, 2-4 nm deep. The cleft, whether determined as a fraction of height by AFM or as a fraction of mass thickness by STEM, is of comparable magnitude. On either side of the cleft, hexamers attain a maximum height of 13-16 nm. Monomers found in the absence of ATP show heights of 5-7 nm. Taken together, the z coordinates provide a surface profile of complete and partial replication assemblies consistent with the spatial distribution of recognition pentanucleotides on the DNA, and they contribute direct geometrical evidence for a ring-like hexamer structure.

Antigens, Viral, Tumor

Mapping interaction forces with the atomic force microscope.

Force curves were recorded as the sample was raster-scanned under the tip. This opens new opportunities for imaging with the atomic force microscope: several characteristics of the samples can be measured simultaneously, for example, topography, adhesion forces, elasticity, van der Waals, and electrostatic interactions. The new opportunities are illustrated by images of several characteristics of thin metal films, aggregates of lysozyme, and single molecules of DNA.

Adsorption

Atomic force microscopy of biochemically tagged DNA.

Small fragments of DNA of known length were made with the polymerase chain reaction. These fragments had biotin molecules covalently attached at their ends. They were subsequently labeled with a chimeric protein fusion between streptavidin and two immunoglobulin G-binding domains of staphylococcal protein A. This tetrameric species was expected to bind up to four DNA molecules via their attached biotin moieties. The DNA-protein complex was deposited on mica and imaged with an atomic force microscope. The images revealed the protein chimera at the expected location at the ends of the strands of DNA as well as the expected dimers, trimers, and tetramers of DNA bound to a single protein.

Bacterial Proteins

Structure of the extracellular surface of the gap junction by atomic force microscopy.

The extracellular surface of the gap junction cell-to-cell channels was imaged in phosphate-buffered saline with an atomic force microscope. The fully hydrated isolated gap junction membranes adsorbed to mica were irregular sheets approximately 1-2 microns across and 13.2 (+/- 1.3) nm thick. The top bilayer of the gap junction was dissected by increasing the force applied to the tip or sometimes by increasing the scan rate at moderate forces. The exposed extracellular surface revealed a hexagonal array with a center-to-center spacing of 9.4 (+/- 0.9) nm between individual channels (connexons). Images of individual connexons with a lateral resolution of < 3.5 nm, and in the best case approximately 2.5 nm, were reliably and reproducibly obtained with high-quality tips. These membrane channels protruded 1.4 (+/- 0.4) nm from the extracellular surface of the lipid membrane, and the atomic force microscope tip reached up to 0.7 nm into the pore, which opened up to a diameter of 3.8 (+/- 0.6) nm on the extracellular side.

Animals

Atomic force microscopy of single- and double-stranded DNA.

A method has been developed for imaging single-stranded DNA with the atomic force microscope (AFM). phi X174 single-stranded DNA in formaldehyde on mica can be imaged in the AFM under propanol or butanol or in air. Measured lengths of most molecules are on the order of 1 mu, although occasionally more extended molecules with lengths of 1.7 to 1.9 mu are seen. Single-stranded DNA in the AFM generally appears lumpier than double-stranded DNA, even when extended. Images of double-stranded lambda DNA in the AFM show more sharp kinks and bends than are typically observed in the electron microscope. Dense, aggregated fields of double-stranded plasmids can be converted by gentle rinsing with hot water to well spread fields.

Bacteriophage lambda