Magnetic resonance volume flow and jet velocity mapping in aortic coarctation.

OBJECTIVES: Nuclear magnetic resonance (MRI) velocity mapping was used to characterize flow waveforms and to measure volume flow in the ascending and descending thoracic aorta in patients with aortic coarctation and in healthy volunteers. We present the method and discuss the relation between these measurements and aortic narrowing assessed by MRI. Finally, we compare coarctation jet velocity measured by MRI velocity mapping with that obtained from continuous wave Doppler echocardiography. BACKGROUND: The development of a noninvasive imaging method for morphologic visualization of aortic coarctation and for measurement of its impact on blood flow is highly desirable in the preoperative and postoperative management of patients. METHODS: Magnetic resonance imaging phase-shift velocity mapping was used to measure ascending and descending aortic volume flow in 39 patients with aortic coarctation and in 12 healthy volunteers. Magnetic resonance imaging was also used for anatomic and peak jet velocity measurements. The latter were compared with those available from continuous wave Doppler study in 40% of the patients. RESULTS: Whereas ascending aortic volume flow measurement did not show significant differences between the patient and healthy control groups, volume flow curves in the descending aorta did show significant differences between the two groups. Peak volume flow (mean +/- SD) was 10.6 +/- 5.3 liters/min in patients and 19.6 +/- 4.7 liters/min in control subjects (p < 0.001). Time-averaged flow was 2.5 +/- 0.9 liters/min in patients and 3.9 +/- 1.1 liters/min in control subjects (p < 0.05). The descending/ascending aorta flow ratio was 0.47 +/- 0.19 in patients and 0.64 +/- 0.08 in control subjects (p < 0.05). These variables correlate well with the degree of aortic narrowing. Peak coarctation jet velocity measured by MRI velocity mapping is comparable to that obtained from continuous wave Doppler study (r = 0.95). CONCLUSIONS: We established normal ranges for volume flow in the descending aorta and demonstrated abnormalities in patients with aortic coarctation. These abnormalities are likely to be related to resistance to flow imposed by the coarctation and could represent an additional index for monitoring patients before and after intervention.

Adolescent↗

Magnetic resonance jet velocity mapping in mitral and aortic valve stenosis.

BACKGROUND: Magnetic resonance (MR) phase-shift velocity mapping is an established method for measurement of nonturbulent intravascular flow. Shortening the echo time of the MR sequence to 3.6 msec allowed application of the technique to turbulent jet flow. The objective of this study was validation of MR jet velocity mapping in patients with cardiac valve stenosis. METHODS AND RESULTS: We used a 0.5-T Picker MR machine to measure peak poststenotic jet velocity in 15 consecutive patients recruited with known valve disease (six mitral stenosis, three of these restudied after valvoplasty, and 11 aortic stenosis). On the same day as the MR study, these patients underwent independent Doppler echocardiographic measurement of peak jet velocity. The results of 10 further MR investigations of aortic stenosis are also reported and compared with Doppler studies performed within 6 months. Of the 29 MR studies, 28 (97%) produced interpretable velocity maps, the one failure being attributed to misplacement of the imaging slice in a case of severe aortic stenosis. Agreement between MR and Doppler measurements of peak jet velocity in the recruited group was as follows: n = 18; range, 1.4-6.1 m/sec; mean, 3 m/sec; mean of differences (MR-Doppler), 0.23 m/sec; standard deviation of differences, 0.49 m/sec. CONCLUSIONS: In vivo MR peak jet velocity measurements agree well with those made by Doppler ultrasound. The technique, which is not subject to restricted windows of access and has potential for further refinements, could contribute to improved evaluation of stenoses, especially at locations where ultrasonic access is limited.

Aortic Valve Stenosis↗

Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping.

BACKGROUND: Helical and retrograde secondary flows have been recorded in the aorta, but their origins and movements in relation to the arch have not been clarified. We set out to do this using magnetic resonance velocity mapping. METHODS AND RESULTS: Three-directional phase contrast cine magnetic resonance velocity mapping was used to map multidirectional flow velocities in the aortas of 10 healthy volunteers. Computer processing was used to visualize flow vector patterns in selected planes. Right-handed helical flows predominated in the upper aortic arch in late systole, being clearly recognizable in 9 of the 10 subjects. Nonaxial components of velocity in this region reached 0.29 m/s (+/- 0.05 m/s) as axial velocities declined from a peak of 1.0 m/s (+/- 0.1 m/s). Helical flow patterns in the upper descending aorta varied between subjects, apparently depending on arch curvature. End-systolic retrograde flow originated from regions of blood with low momentum, usually along inner wall curvatures. Flow studies in a curved tubular phantom showed right-handed helical flow in the upper "arch" when the inflow section was positioned to simulate ascending aortic curvature, and retrograde flow occurred along the inner wall at end systole during pulsatile flow. CONCLUSIONS: Helical and retrograde streams are consistent features of intra-aortic flow in healthy subjects that result, at least in part, from the curvature of the arch and the pulsatility of flow in it. They may have significance in relation to circulatory dynamics and the pathogenesis of atheroma in the arch.

Adult↗

Obstruction in extracardiac ventriculopulmonary conduits: value of nuclear magnetic resonance imaging with velocity mapping and Doppler echocardiography.

OBJECTIVES: This study was designed to investigate the value of noninvasive imaging modalities for the detection of obstruction in extracardiac ventriculopulmonary conduits. BACKGROUND: the diagnosis of obstruction in a conduit by noninvasive methods can be difficult. Obstruction may be silent and its progression unnoticed. Nuclear magnetic resonance imaging (NMR) with velocity mapping is a new noninvasive technique that can provide high resolution images and has been shown to be a reliable method of measuring blood flow velocity. METHODS: Two-dimensional echocardiography, pulsed wave Doppler echocardiography and NMR spin echo imaging were used in 52 patients with an extracardiac ventriculopulmonary conduit. Continuous wave Doppler echocardiography was used in 30 of these, Doppler color flow mapping in 26 and NMR velocity mapping in 12. Cardiac catheterization data were available in 27 patients and operative or autopsy findings in 11. RESULTS: The conduit could be assessed by two-dimensional and pulsed wave Doppler echocardiography in only 17% of patients. Doppler color flow and continuous wave echocardiography provided technically satisfactory data in 19% and 83%, respectively. The anatomy of the conduit was adequately displayed by NMR imaging in 90%. A minimal diameter less than 18 mm indicated conduit obstruction, although failure to detect calcification resulted in obstruction being missed in some patients. Calculated gradients in obstructed conduits derived from NMR velocity mapping correlated well with results of continuous wave Doppler echocardiography and gave an accurate localization of the site of obstruction as well as a measure of its severity. CONCLUSION: NMR imaging with velocity mapping is the most effective noninvasive method of assessing obstruction in ventriculopulmonary conduits and can obviate the need for invasive investigation before an interventional procedure is performed.

Adult↗

Haemoptysis from false aneurysm: near fatal complication of repair of coarctation of the aorta using a Dacron patch.

We report a case of haemoptysis from a leaking false aneurysm associated with a Dacron patch used to repair coarctation of the aorta twelve years earlier in a 17-year-old girl. This case illustrates a late and potentially fatal complication of this type of operation after a long period of apparent normality. It emphasises the need for informed follow-up and appropriate correctly timed investigations.

Adolescent↗

Valve and great vessel stenosis: assessment with MR jet velocity mapping.

For measurement of poststenotic jet velocities with magnetic resonance (MR) imaging, the authors reduced the echo time (TE) of the field even-echo rephasing (FEER) velocity mapping sequence from 14.0 to 3.6 msec, so minimizing the problem of MR signal loss from turbulent fluid. In vitro use of rotating disk and stenotic flow phantoms confirmed that the 3.6-msec TE sequence enables accurate measurement of jet velocities of up to 6.0 m/sec (r = .996). Peak jet velocity measurements were made with MR imaging in 36 patients with stenosis of native heart valves (n = 9), conduits (n = 19), or Fontan connections (n = 2) or with aortic coarctation (n = 6). Peak velocity measurements made with MR imaging agreed well with measurements made with Doppler ultrasound (US), which were available in 18 cases (standard deviation = 0.2 m/sec). Velocity mapping with fast-echo MR imaging is likely to have considerable importance as a noninvasive means of locating and evaluating stenoses, particularly at sites inaccessible to US, but care must be taken to prevent errors caused by malalignment, signal loss, phase wrap, or partial-volume effects.

Adult↗

The application of phase shifts in NMR for flow measurement.

A brief overview of the history of the application of phase shifts in NMR, and in particular NMR imaging, is presented. The imaging methods include direct phase mapping, Fourier flow imaging (where the flow data are Fourier transformed into one dimension of an image), and alternative methods, where flow-related phase shifts are utilized for flow measurement from the magnitude of the signal. A discussion then follows of the principal errors that can affect the accuracy of the various flow imaging techniques, with particular reference to the phase mapping methods that have been used extensively in our institution. The results from a number of experiments are included to illustrate the extent of the errors and methods of removing or minimizing these effects are suggested.

Blood Circulation↗

Cardiovascular cavities cast in silicone rubber as an adjunct to post-mortem examination of the heart.

We used silicone rubber as a material for making post-mortem casts of cavities in 21 human hearts, 16 of them congenitally malformed, 13 after surgical reconstruction (Fontan and Norwood procedures) and 4 after reconstruction had been performed posts mortem for study purposes. The organs were either fresh, or had been perfusion fixed with formalin prior to casting. When suitable silicone rubber and catalyst were used, we found that casts allowed a very clear view of chamber morphology, and, where surgery had been performed, of any vascular constriction or distortion. We made casts of the aortic sinus and coronary arteries in 3 adult hearts, demonstrating the location and extent of indentation due to atheromatous deposits. The resilience and non-adhesiveness of the silicone rubber allowed casts to be extracted without recourse to corrosion. The surrounding tissues, with the exception of trapped trabeculations and valve structures, were then available for conventional pathological examination. We propose that the relatively simple technique has important applications, not practicable using earlier casting materials, for the study of cardiovascular morphology, and for post-mortem evaluation of stenosed or surgically reconstructed vessels.

Adult↗

Dynamic range extension of cine velocity measurements using motion-registered spatiotemporal phase unwrapping.

A motion-registered spatiotemporal phase-unwrapping method for extending the dynamic range of cine magnetic resonance phase velocity measurements is presented. The interframe cardiac movement is estimated from the magnitude image derived from the velocity encoded raw data, which ensures that the phase signal is unwrapped in the temporal direction with reference to pixels belonging to the same anatomic flow region. An extra step of spatial phase correction is then used to further eliminate any residual errors. The combination of spatial and temporal information for phase unwrapping provides a robust way of extending the dynamic range of cine velocity data in the presence of large phase aliasing errors.

Algorithms↗

Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: the effects of age and coronary artery disease.

The objective was to investigate how the blood flows in the thoracic aorta, with special emphasis on flow reversal and flow into the coronary arteries. Three-directional MR velocity mapping was used to map multidirectional flow velocities in the aorta in 14 normal subjects and 14 patients with coronary artery disease. Dynamic flow vector maps and through-plane velocity maps were used. The flow reversed in all subjects in the upper ascending aorta and usually also in the distal aortic arch. Retrograde flow became antegrade again at various levels in the ascending aorta and in the coronary sinuses. Seven flow characteristics were investigated that, lumped together, were significantly different (P = .0005) in normal subjects compared with patients and in normal subjects 70 years of age and older compared with those younger than 70 years of age.

Adult↗

MR phase-shift velocity mapping of mitral and pulmonary venous flow.

Mitral and pulmonary venous flows are important indexes in the evaluation of left ventricular diastolic function and in the assessment of mitral valve disease. We used MR phase-shift velocity mapping to measure mitral and pulmonary venous flow velocity in 10 healthy volunteers and mitral flow velocity in 5 patients with mitral valve stenosis. Normal mitral flow shows two positive peaks: one during early ventricular diastole and the other during atrial contraction. Peak mitral flow velocity (mean +/- SD) in early diastole was 68 +/- 12 cm/s and during atrial contraction 39 +/- 10 cm/s. The ratio of peak mitral flow velocity in early diastole to that during atrial contraction was 1.9 +/- 0.6. In patients with mitral valve stenosis, the initial high flow velocity persisted through diastole. Peak mitral flow velocity of patients with mitral valve stenosis correlated well with values obtained from Doppler echocardiography. Pulmonary venous flow showed two positive peaks: one during ventricular systole and the other in ventricular diastole. A small backflow during atrial contraction was noticed. Peak systolic velocity in the right lower pulmonary vein was 47 +/- 11 cm/s, peak diastolic velocity was 40 +/- 9 cm/s, and peak backflow velocity was 14 +/- 3 cm/s. Magnetic resonance velocity mapping is a noninvasive technique for the evaluation of time-related flow velocity patterns and for quantitative measurement of mitral and pulmonary venous blood flow velocity.

Adult↗

Visualization of flow by vector analysis of multidirectional cine MR velocity mapping.

OBJECTIVE: We describe a noninvasive method for visualization of flow and demonstrate its application in a flow phantom and in the great vessels of healthy volunteers and patients with aortic and pulmonary arterial disease. The technique uses multidirectional MR velocity mapping acquired in selected planes. Maps of orthogonal velocity components were then processed into a graphic form immediately recognizable as flow. MATERIALS AND METHODS: Cine MR velocity maps of orthogonal velocity components in selected planes were acquired in a flow phantom, 10 healthy volunteers, and 13 patients with dilated great vessels. Velocities were presented by multiple computer-generated streaks whose orientation, length, and movement corresponded to velocity vectors in the chosen plane. RESULTS: The velocity vector maps allowed visualization of complex patterns of primary and secondary flow in the thoracic aorta and pulmonary arteries. The technique revealed coherent, helical forward blood movements in the normal thoracic aorta during midsystole and a reverse flow during early diastole. Abnormal flow patterns with secondary vortices were seen in patients with dilated arteries. CONCLUSION: The potential of MR velocity vector mapping for in vitro and in vivo visualization of flow patterns is demonstrated. Although this study was limited to two-directional flow in a single anatomical plane, the method provides information that might advance our understanding of the human vascular system in health and disease. Further developments to reduce the acquisition time and the handling and presenting of three-directional velocity data are required to enhance the capability of this method.

Adolescent↗

Vortical flow feature recognition: a topological study of in vivo flow patterns using MR velocity mapping.

PURPOSE: To describe an automatic method for studying vortical flow features using multidirectional magnetic resonance velocity imaging. METHODS: The technique relied on the use of linear differential equations to provide local approximation to the acquired MR velocity data and to identify vortical flow patterns that were characterised by their circular or swirling motion. Two directional MR velocity images were acquired on a 0.5 T system with a TE of 14 ms, slice thickness of 10 mm, and field of view of 30-40 cm. RESULTS: The method was validated using numerical simulation, and the potential of this technique for studying blood flow features was demonstrated in the ascending aorta of a healthy volunteer and that of a patient with Marfan's syndrome. The difference in vortex flow dynamics of the left ventricle between a normal subject and a patient with dilated ventricle was also compared. CONCLUSION: The approach of detecting critical flow features prior to analysing dynamical indices of the fluid is suited to the topological study of complex flow patterns depicted by MR velocity mapping techniques.

Algorithms↗