Search PubMed⌕ Search

Biomedical subjects

P J Gregg

Publications and source records attributed to P J Gregg.

At least 19 recordsLinked to original sources

Outcome of Charnley total hip replacement across a single health region in England. The results at ten years from a regional arthroplasty register.

Using the Trent regional arthroplasty register, we analysed the survival at ten years of 1198 consecutive Charnley total hip replacements carried out across a single health region of the United Kingdom in 1990. At ten years, information regarding outcome was available for 1001 hips (83.6%). The crude revision rate was 6.2% (62 of 1001) and the cumulative survival rate with revision of the components as an end-point was 93.1%. At five years, a review of this series of patients identified gross radiological failure in 25 total hip replacements which had previously been unrecognised. At ten years the outcome was known for 18 of these 25 patients (72%), of whom 13 had not undergone revision. This is the first study to assess the survival at ten years for the primary Charnley total hip replacement performed in a broad cross-section of hospitals in the United Kingdom, as opposed to specialist centres. Our results highlight the importance of the arthroplasty register in identifying the long-term outcome of hip prostheses.

Adult↗

Should we reconsider all-polyethylene tibial implants in total knee replacement?

The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-Sigma total knee replacement for up to 24 months. There were 51 patients who were randomised into two treatment groups. There were 10 subsequent withdrawals, leaving 21 all-polyethylene and 20 metal-backed tibial implants. No patient was lost to follow-up. There were no significant demographic differences between the groups. At two years one metal-backed implant showed migration > 1 mm, but no polyethylene implant reached this level. There was a significant increase in the SF-12 and Oxford knee scores after operation in both groups. In an uncomplicated primary total knee replacement the all-polyethylene PFC-Sigma tibial prosthesis showed no statistical difference in migration from that of the metal-backed counterpart. There was no difference in the clinical results as assessed by the SF-12, the Oxford knee score, alignment or range of movement at 24 months, although these assessment measures were not statistically powered in this study.

Aged↗

Continuous monitoring of the performance of hip prostheses.

New brands of joint prosthesis are released for general implantation with limited evidence of their long-term performance in patients. The CUSUM continuous monitoring method is a statistical testing procedure which could be used to provide prospective evaluation of brands as soon as implantation in patients begins and give early warning of poor performance. We describe the CUSUM and illustrate the potential value of this monitoring tool by applying it retrospectively to the 3M Capital Hip experience. The results show that if the clinical data and methodology had been available, the CUSUM would have given an alert to the underperformance of this prosthesis almost four years before the issue of a Hazard Notice by the Medical Devices Agency. This indicates that the CUSUM can be a valuable tool in monitoring joint prostheses, subject to timely and complete collection of data. Regional or national joint registries provide an opportunity for future centralised, continuous monitoring of all hip and knee prostheses using these techniques.

Adult↗

Glove perforation and contamination in primary total hip arthroplasty.

We conducted a randomised, controlled trial to determine whether changing gloves at specified intervals can reduce the incidence of glove perforation and contamination in total hip arthroplasty. A total of 50 patients were included in the study. In the study group (25 patients), gloves were changed at 20-minute intervals or prior to cementation. In the control group (25 patients), gloves were changed prior to cementation. In addition, gloves were changed in both groups whenever there was a visible puncture. Only outer gloves were investigated. Contamination was tested by impression of gloved fingers on blood agar and culture plates were subsequently incubated at 37 degrees C for 48 hours. The number of colonies and types of organisms were recorded. Glove perforation was assessed using the water test. The incidence of perforation and contamination was significantly lower in the study group compared with the control group. Changing gloves at regular intervals is an effective way to decrease the incidence of glove perforation and bacterial contamination during total hip arthroplasty.

Arthroplasty, Replacement, Hip↗

Bacterial contaminants and antibiotic prophylaxis in total hip arthroplasty.

We have investigated the contaminating bacteria in primary hip arthroplasty and their sensitivity to the prophylactic antibiotics currently in use. Impressions (627) of the gloved hands of the surgical team in 50 total hip arthroplasties were obtained on blood agar. The gloves were changed after draping, at intervals of 20 minutes thereafter, and before using cement. Changes were also undertaken whenever a visible puncture was detected. The culture plates were incubated at 37 degrees C for 48 hours. Isolates were identified and tested for sensitivity to flucloxacillin, which is a recognised indicator of sensitivity to cefuroxime. They were also tested against other agents depending upon their appearance on Gram staining. We found contamination in 57 (9%) impressions and 106 bacterial isolates. Coagulase-negative staphylococci were seen most frequently (68.9%), but we also isolated Micrococcus (12.3%), diphtheroids (9.4%), Staphylococcus aureus (6.6%) and Escherichia coli (0.9%). Of the coagulase-negative staphylococci, only 52.1% were sensitive to flucloxacillin and therefore to cefuroxime. We believe that it is now appropriate to review the relevance of prophylaxis with cefuroxime and to consider the use of other agents.

Anti-Bacterial Agents↗

Superficial incisional infection in arthroplasty of the lower limb. Interobserver reliability of the current diagnostic criteria.

The Department of Health and the Public Health Laboratory Service established the Nosocomial Infection National Surveillance Scheme in order to standardise the collection of information about infections acquired in hospital in the United Kingdom and provide national data with which hospitals could measure their own performance. The definition of superficial incisional infection (skin and subcutaneous tissue), set by the Center for Disease Control (CDC), should meet at least one of the defined criteria which would confirm the diagnosis and determine the need for specific treatment. We have assessed the interobserver reliability of the criteria for superficial incisional infection set by the CDC in our current practice. The incisional site of 50 patients who had an elective primary arthroplasty of the hip or knee was evaluated independently by two orthopaedic clinical research fellows and two orthopaedic ward sisters for the presence or absence of surgical-site infection. Interobserver reliability was assessed by comparison of the criteria for wound infection used by the four observers using kappa reliability coefficients. Our study demonstrated that some of the components of the current CDC criteria were unreliable and we recommend their revision.

Aged↗

A comparison of Rasch with Likert scoring to discriminate between patients' evaluations of total hip replacement surgery.

The purpose of this study was to examine whether there are advantages in terms of outcome assessment of using Rasch methods of scoring the 12-item Oxford Hip Score (OHS) questionnaire over conventionally Likert scores. As part of a prospective cohort study of total hip replacements in five former regions of England the OHS was sent to patients pre-operatively, at 3 months and 1 year post-operatively. Post-operative data was collected on over 5000 cases. Based on the level of satisfaction with surgery, patients were divided into satisfied and dissatisfied. Analyses were performed to test the relative precision (RP) of Rasch scoring vs. conventionally Likert scores in discriminating the groups experiencing different level of satisfaction. Considerable gains in precision were achieved with Rasch scoring methods when groups were compared 3 and 12 months post-operatively. The results from the current study suggest that in some situations there may be substantial gains in measuring health related outcomes using Rasch-based scoring methods.

Activities of Daily Living↗

Lower limb arthroplasty complicated by deep venous thrombosis. Prevalence and subjective outcome.

The aim of this study was to determine the prevalence of deep venous thrombosis (DVT) following lower limb arthroplasty and to assess whether this adversely affected satisfaction, relief from pain, or the level of mobility as perceived by patients. Six hundred and ten consecutive recipients of primary total hip replacement (THR) or total knee replacement (TKR) underwent routine post-operative venography. The functional outcome had already been assessed at one year by using the Regional Arthroplasty Database questionnaire, the results of which were correlated to venographic records. The combined prevalence of DVT after THR and TKR in the patients, who did not receive chemical thromboprophylaxis, was 46.4%. Thrombus was identified in 57.6% of those with a TKR and in 33.5% of patients with a THR. Proximal thrombus was found in 11.0% of TKRs and in 14.8% of THRs. One year after surgery, patients who had a DVT established by venography did not report higher levels of immobility (p = 0.07), discomfort (p = 0.12) or dissatisfaction (p = 0.23) when compared to those with patent venous systems. This suggests that the prevalence of DVT following TKR/THR without chemical thromboprophylaxis is high and these findings are consistent with the literature. However, patients did not perceive thrombosis to compromise their overall outcome. This challenges the belief that DVT is associated with morbidity and calls for further comprehensive research in this area. The low morbidity of the lower limb associated with DVT in these patients does not support the use of chemical thromboprophylaxis.

Arthroplasty, Replacement, Hip↗

A preliminary hip joint simulator study of the migration of a cemented femoral stem.

A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemented femoral stem within a novel composite femur. The study demonstrates the value of using a hip joint simulator to evaluate the outcome of the cemented hip construct. A complex migration pattern of the cemented hip prosthesis with respect to load cycling was observed, demonstrated in vitro comparable prosthesis migration behaviour, both the stem migration and migration patterns, to that found clinically.

Cementation↗

Relationship between outcome and annual surgical experience for the charnley total hip replacement. Results from a regional hip register.

Using a regional arthroplasty register, we assessed the outcome, at five years, of 1198 primary Charnley total hip replacements (THRs) undertaken across a single health region in England in 1990. An independent clinical and radiological assessment was completed for 497 operations, carried out in 18 different hospitals, under the care of 56 consultants and by differing grades of surgeon. The overall number of failures in this group was 44 (8.9%). We found that the risk of failure in patients operated on by a consultant whose firm carried out 60 or more THRs in 1990 was 25% of that of patients under the care of a consultant whose firm undertook less than 30, adjusting for a number of patient, surgeon and hospital characteristics (16% v 4%; p < 0.001 for linear trend). Our study shows that the early outcome of hip replacement surgery varies with the number of replacements undertaken by the consultant firm. A national arthroplasty register would be a convenient source for such data.

Aged↗

Creep behavior comparison of CMW1 and palacos R-40 clinical bone cements.

The restrained dynamic creep behaviors of two clinical bone cements, Palacos R-40 and CMW1 have been investigated at room temperature and body temperature. It was found that the two cements demonstrated significantly different creep deformations, with Palacos R-40 bone cement demonstrating higher creep strain than CMW1 bone cement at each loading cycle. For both cements, two stages of creep were identified with a higher creep rate during early cycling followed by a steady-state creep rate. The test temperature had a strong effect on the creep performance of the bone cements with higher creep rate observed at body temperature. The relationship between creep deformation and loading cycles can be expressed by single logarithmic model. The SEM examinations revealed that CMW1 bone cement is more sensitive to defects within the specimen especially to the defects at the edges of the specimen than Palacos R-40 bone cement. However, in the absence of micro-cracks or defects within the inner surface layer, the dynamic loading (at less than 10.6 MPa) is unlikely to produce micro-cracks in the CMW1 bone cement. The different behaviors between the two bone cements may be attributed to differences in chemical compositions and molecular weight distributions.

Journal Article↗

A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement. Ten-year survival analysis.

We have carried out a long-term survival analysis of a prospective, randomised trial comparing cemented with cementless fixation of press-fit condylar primary total knee replacements. A consecutive series of 501 replacements received either cemented (219 patients, 277 implants) or cementless (177 patients, 224 implants) fixation. The patients were contacted at a mean follow-up of 7.4 years (2.7 to 13.0) to establish the rate of survival of the implant. The ten-year survival was compared using life-table and Cox's proportional hazard analysis. No patient was lost to follow-up. The survival at ten years was 95.3% (95% CI 90.3 to 97.8) and 95.6% (95% CI 89.5 to 98.2) in the cemented and cementless groups, respectively. The hazard ratio for failure in cemented compared with cementless prostheses was 0.97 (95% CI 0.36 to 2.6). A comparison of the clinical outcome at ten years in 80 knees showed no difference between the two groups. The survival of the press-fit condylar total knee replacement at ten years is good irrespective of the method of fixation and brings into question the use of more expensive cementless implants.

Arthritis, Rheumatoid↗

Current cementing techniques in hip hemi-arthroplasty.

To assess the use of modern cementing techniques in hip hemi-arthroplasty a postal questionnaire was sent during 1998 to all British Orthopaedic Training Association (B.O.T.A.) members regarding use of cement, type of cement, bone preparation and cementing technique. The results of this survey were compared to a similar survey in 1994 to assess any change in practice. Two hundred and eighty-six trainees responded to the 1998 survey, 352 to the 1994 survey. The use of uncemented prostheses had decreased from 31.3 in 1994 to 21.7% in 1998. Normal viscosity Palacos cement remains the most common cement in use, 64.3% in 1998. The use of antibiotic loaded cement has increased from 53.7 in 1994 to 67.9% in 1998. For bone preparation 47.3% of trainees in 1998 used a modern technique (syringe irrigation/pulsed lavage, brushing, gauze packing) compared to 35.1% in 1994. Modern cement insertion (retrograde gun, cement restriction and sustained pressure) was carried out by 39.3% in 1998 compared to 28.5% in 1994. Overall 27.2% of trainees used modern cementing techniques in hip hemi-arthroplasty, compared to 19.4% in 1994. Modern cementing techniques are used by a minority of British orthopaedic trainees, but in comparison to 1994 their use has increased.

Arthroplasty, Replacement, Hip↗

Survival analysis of cemented Press-Fit Condylar total knee arthroplasty.

We performed a survival analysis on 354 cemented primary Press-Fit Condylar (PFC) total knee arthroplasties (TKA) in 277 patients with prospective follow-up (mean, 6 years; range, 2-11.7 years). No patient was lost to follow-up. Using revision for all causes as the endpoint, the cumulative survival rate at 10 years was 95.5% (95% confidence interval, 90.1%-98.1%). The 10-year clinical outcome available on 41 patients was good, with significant improvement in pain and mobility assessments using the Nottingham data collection system. Our results indicate that the cemented PFC TKA has good long-term survival based on revision as the endpoint. Revision for implant failure is rare and brings to question modifications to this prosthesis.

Adult↗

Some failure modes of four clinical bone cements.

The fracture or failure behaviours of four commercial acrylic-based bone cements have been examined in tensile, bending and compression modes, and their mechanical properties are reviewed. It was found that Palacos R-40 bone cement had high radiopaque agent concentration, with high surface hardness. It exhibited a much lower bending strength and bending modulus compared with the other three bone cements (CMW1, CMW2000 and Simplex P). The textures of tensile fracture surfaces produced were similar for the four bone cements studied. The fracture surface was fragmented by crevices, which developed through the matrix and around large undissolved polymethylmethacrylate (PMMA) beads. Three bands with different features existed on the bending fracture surfaces, with an abrupt transition between them. It appears that the agglomerates of zirconium dioxide particles are implicated in Palacos R-40 bone cement fracture surface. The examination of compressive failed specimens revealed that a 'yielded crack band' existed across the transverse section. Plastic deformation resulted in the PMMA beads being squashed in the longitudinal direction and dilated in the transverse direction.

Biomechanical Phenomena↗

Treatment for displaced intracapsular fracture of the proximal femur. A prospective, randomised trial in patients aged 65 to 79 years.

We performed a prospective, randomised trial comparing three treatments for displaced intracapsular fractures of the hip in 280 patients aged 65 to 79 years. The mean patient survival was significantly higher in the group undergoing reduction and internal fixation (79 months) compared with that with a cemented Thompson hemiarthroplasty or a cemented Monk bipolar hemiarthroplasty (61 months and 68 months, respectively). After three years, 32 of 93 patients (34.4%) who had undergone fixation had local complications, necessitating further intervention in 28 (30%). There were no significant differences in the functional outcome in survivors, who were reviewed annually to five years. Either reduction and internal fixation or cemented hemiarthroplasty may be offered as alternative treatments for a displaced intracapsular fracture in a mobile and mentally competent patient under the age of 80 years. The choice of procedure by the patient and the surgeon should be determined by the realisation that the use of internal fixation is associated with a 30% risk of failure requiring further surgery. If this is accepted, however, hemiarthroplasty is avoided, which, in our study has a significantly shorter mean survival time. The use of a bipolar prosthesis has no significant advantage.

Aged↗

Radiological features predictive of aseptic loosening in cemented Charnley femoral stems.

The radiological features of the cement mantle around total hip replacements (THRs) have been used to assess aseptic loosening. In this case-control study we investigated the risk of failure of THR as predictable by a range of such features using data from patients recruited to the Trent Regional Arthroplasty Study (TRAS). An independent radiological assessment was undertaken on Charnley THRs with aseptic loosening within five years of surgery and on a control group from the TRAS database. Chi-squared tests were used to test the probability of obtaining the observed data by chance, and odds ratios were calculated to estimate the strength of association for different features. Several features were associated with a clinically important increase (>twofold) in the risk of loosening, which was statistically significant for four features (p < 0.01). Inadequate cementation (Barrack C and D grades) was the most significant feature, with an estimated odds ratio of 9.5 (95% confidence interval 3.2 to 28.4, p < 0.0001) for failure.

Case-Control Studies↗

Ulceration of the lower leg after total knee replacement a five-year review.

Ulceration of the lower leg is considered to be a hard' clinical endpoint of venous thrombosis. Total knee replacement (TKR) is a significant risk factor for venous thrombosis of the leg and therefore potentially for ulceration. We sent a postal questionnaire to 244 patients at a minimum of five years after TKR enquiring about the development of ulceration since their TKR. The overall incidence of ulceration, both active and healed, was 8.67% which is similar to that in the age-matched general population (9.6% to 12.6%), as was the prevalence of active ulceration. We also identified no clear association between venographically-confirmed postoperative deep-venous thrombosis (DVT) and the incidence and prevalence of ulcers at five years. We suggest that after TKR DVT is not a significant risk factor for ulceration of the leg and that perioperative chemical thromboprophylaxis may not be justified on these grounds.

Aged↗