Search PubMedSearch

Biomedical subjects

P J Caroline

Publications and source records attributed to P J Caroline.

5 recordsLinked to original sources

The effect of modification procedures on rigid gas permeable contact lenses: the UM-St. Louis Study.

The purpose of this study is to evaluate the effect of frequently performed modification procedures on quality of vision, surface wettability, optical quality and subjective response. One subject was optimally fitted with both silicone/acrylate (S/A) and fluoro-silicone/acrylate (F-S/A) lens materials of identical design. Two methods of surface polishing, edge polishing and repowering were used in addition to three different spindle speeds. Each pair of lenses was worn by the subject for a period of 4 hours and the subjective response was then compared to the baseline or premodification data. In addition, both low magnification photography and Scanning Electron Microscopy (S.E.M.) were performed on each lens. The results showed that the addition of 0.50D minus power reduced visual acuity, contrast sensitivity function and optical quality with one of the methods used. Front surface polish and edge polish procedures did not appear to affect short-term performance. Controlling polish, application and tool pressure on certain procedures resulted in similar findings. Further studies would be beneficial to evaluate the effect of longer wearing periods and the use of other modification procedures. The authors conclude that S/A and F-S/A lens materials can be successfully modified in-office with adherence to recommended guidelines.

Contact Lenses

Irregular astigmatism after radial and astigmatic keratotomy.

Eleven eyes of six patients, who had been referred for management of irregular astigmatism after receiving crossed incisions for myopic astigmatism, had moderate to marked irregular corneal astigmatism with marked flattening in the meridians of intersecting incisions. All six patients had a decrease in best-corrected visual acuity with spectacles after surgery. Visual acuity with spectacles was 20/40 in five of 11 eyes; with contact lenses it reached 20/40 in ten of 11 eyes. However, two patients could not wear the contact lenses because of lens decentration caused by the marked distortion in corneal topography. Even with contact lenses, visual acuity could only be improved to 20/25 or better in six of 11 eyes.

Astigmatism

Role of spherical aberration in contrast sensitivity loss with radial keratotomy.

A technique is described to determine the change in image contrast as a result of the spherical aberration induced by the radial keratotomy procedure. The hypothesis that the loss in contrast sensitivity of the RK eye is due to the change in spherical aberration postsurgically, is found to be acceptable for some patients. However, this is not a sufficient explanation in all cases. This conclusion may be due to assumptions inherent in the technique derived for calculating spherical aberration or to other factors of importance in the post-RK eye.

Contrast Sensitivity