Search PubMed⌕ Search

Biomedical subjects

P J Blamey

Publications and source records attributed to P J Blamey.

At least 19 recordsLinked to original sources

Phonetic inventory development in young cochlear implant users 6 years postoperation.

Increases in the phonetic inventories of a group of 9 children in the fifth and sixth years of experience with a cochlear implant are reported, extending a previous 4-year study (T. A. Serry & P. J. Blamey, 1999). Thirty-six out of 44 phones in Australian English reached the criterion of 50% correct in the conversational samples of 5 or more children. This level of performance corresponds to intelligible, but not completely natural, speech. The rate of improvement in the sixth year was slow, indicating a probable plateau in performance. The 8 phones that did not attain the 50% criterion in 5 or more children were /see text/. Potential reasons for the slow development or nondevelopment of these phones include very low frequency of occurrence for /see text/ and the perceptual and articulatory characteristics of /see text/. /see text/ is also subject to a high degree of allophonic variation in the fluent speech of normally hearing speakers, probably accounting for much of the variability in its articulation in the conversational samples.

Child↗

Relationships among speech perception, production, language, hearing loss, and age in children with impaired hearing.

Eighty-seven primary-school children with impaired hearing were evaluated using speech perception, production, and language measures over a 3-year period. Forty-seven children with a mean unaided pure-tone-average hearing loss of 106 dB HL used a 22-electrode cochlear implant, and 40 with a mean unaided pure-tone-average hearing loss of 78 dB HL were fitted with hearing aids. All children were enrolled in oral/aural habilitation programs, and most attended integrated classes with normally hearing children for part of the time at school. Multiple linear regression was used to describe the relationships among the speech perception, production, and language measures, and the trends over time. Little difference in the level of performance and trends was found for the two groups of children, so the perceptual effect of the implant is equivalent, on average, to an improvement of about 28 dB in hearing thresholds. Scores on the Peabody Picture Vocabulary Test (PPVT) and the Clinical Evaluation of Language Fundamentals showed an upward trend at about 60% of the rate for normally hearing children. Rates of improvement for individual children were not correlated significantly with degree of hearing loss. The children showed a wide scatter about the average speech production score of 40% of words correctly produced in spontaneous conversations, with no significant upward trend with age. Scores on the open-set Consonant-Nucleus-Consonant (CNC) monosyllabic word test and the Bench-Kowal-Bamford (BKB) sentence test were strongly related to language level (as measured by an equivalent age on the PPVT) and speech production scores for both auditory-visual and auditory test conditions. After allowing for differences in language, speech perception scores in the auditory test condition showed a slight downward trend over time, which is consistent with the known biological effects of hearing loss on the auditory periphery and brainstem. Speech perception scores in the auditory condition also decreased significantly by about 5% for every 10 dB of hearing loss in the hearing aid group. The regression analysis model allows separation of the effects of language, speech production, and hearing levels on speech perception scores so that the effects of habilitation and training in these areas can be observed and/or predicted. The model suggests that most of the children in the study will reach a level of over 90% sentence recognition in the auditory-visual condition when their language becomes equivalent to that of a normally hearing 7-year-old, but they will enter secondary school at age 12 with an average language delay of about 4 or 5 years unless they receive concentrated and effective language training.

Age Factors↗

Effects of articulation training on the production of trained and untrained phonemes in conversations and formal tests.

The aim of this study was to investigate the effectiveness of articulation training for specific phonemes on the production of phonemes in conversational language samples, the 108 Single Word Articulation Test (Paatsch, 1997), and the Phonetic Level Evaluation (Ling, 1976). Speech production skills of 12 hearing-impaired children were assessed using these evaluation tools pre- and posttraining. A total of six phonemes were selected for each child to be trained during 15-to 20-minute daily sessions throughout an 8-week speech production program. Three phonemes, with a particularly high error rate, were trained at a phonetic level (category 1) while three phonemes, with an intermediate error rate of 40% to 70%, were trained at a phonological level (category 2). Results showed improvements in the percentage of correctly articulated category 1 phonemes and category 2 phonemes. The improvements for category 2 phonemes were larger than for category 1 phonemes for all test materials. It may be that phonological level training is more effective than phonetic level training or that phonemes with an intermediate error rate are easier to train than phonemes with a high error rate. Untrained vowels and consonants also improved slightly after training. Phonological process analysis showed that many of the errors apparent in the trained phonemes also had occurred in the untrained phonemes. This may have resulted in the generalization and carryover of taught speech skills into other aspects of the child's spoken language.

Journal Article↗

Variation in speech perception scores among children with cochlear implants.

OBJECTIVE: The objective of this study was to identify common factors affecting speech perception scores in children with cochlear implants. DESIGN: Speech perception data for 167 implanted children were collected at two cochlear implant centres in Melbourne and Sydney. The data comprised audition-alone scores on open-set word and sentence tests. Children were selected on the basis that they had a Nucleus 22-electrode cochlear implant. The average age of the children was 5 yr. Information was also collected about 12 factors that may have influenced speech perception scores for each child. Analysis of covariance was used to identify factors that significantly affected speech perception scores. Pearson pairwise correlation coefficients were also calculated for all factors analyzed. RESULTS: The analyses in this study identified factors that accounted for 51%, 34%, and 45% of the variance in phoneme, word and sentence perception scores. Scores decreased by 1.4 to 2.4% per year of profound deafness prior to implantation. Children who normally use oral communication scored significantly higher than children normally using sign or simultaneous oral and sign communication. Children implanted in Sydney scored higher on average than children implanted in Melbourne. CONCLUSIONS: The results show that a significant part of the variation in speech perception scores is systematically related to audiological and environmental factors for each child. The reasons for significant differences between children using different communication modes or from different clinics were not identified.

Adolescent↗

Monaural and binaural loudness measures in cochlear implant users with contralateral residual hearing.

OBJECTIVE: The aim was to measure the loudness of monaural and binaural stimuli in a group of cochlear implant users who had residual hearing in the nonimplanted ear, and to consider the implications of these measures for a binaural fitting consisting of a hearing aid and an implant in opposite ears. Three independent hypotheses were addressed: that the shapes of the electric and acoustic loudness growth functions would be similar, although the dynamic ranges would differ; that standard implant and hearing aid fittings would result in substantial loudness mismatches between the acoustic and electric signals; and that loudness summation would occur for binaural combinations of electric and acoustic signals. DESIGN: A modified version of the "Loudness Growth in 1/2-Octave Bands" method (Allen, Hall, & Jeng, 1990) was used to measure loudness growth for each ear of nine subjects. At the time of the experiment, the subject group included all implant users in Melbourne and Denver who were available for research and who also had sufficient residual hearing to use a hearing aid in the nonimplanted ear. Five acoustic frequencies and five electrodes were measured for each subject. The same subjects also estimated the loudness of a set of stimuli including monaural and binaural signals chosen to cover the loudness range from very soft to loud. RESULTS: The shapes of the averaged loudness growth functions were similar in impaired and electrically stimulated ears, although the shapes of iso-loudness curves were quite different in the two ears, and dynamic ranges varied considerably. Calculations based on the psychophysical data demonstrated that standard fitting procedures for cochlear implants and hearing aids lead to a complex pattern of loudness differences between the ears. A substantial amount of loudness summation was observed for the binaural stimuli, with most summation occurring when the acoustic and electric components were of equal loudness. This is consistent with observations for subjects with normal hearing and subjects with bilaterally impaired hearing. CONCLUSIONS: These experiments provide data on which criteria and methods for the binaural fitting of cochlear implants and hearing aids may be based. It is unlikely that standard monaural fitting methods for cochlear implants and hearing aids will result in balanced loudness between the two ears across a reasonably broad range of frequencies and levels. It is also likely that output levels of both devices will need to be reduced relative to a monaural fitting to compensate for the binaural summation of loudness in some listeners.

Adult↗

Generalization of tactile perceptual skills to new context following tactile-alone word recognition training with the Tickle Talker.

The Tickle Talker is an electrotactile speech perception device. Subjects were evaluated using the device in various tactile-alone and tactile-visual contexts to assess the generalization to other contexts of tactile-alone perceptual skills. The subjects were from a group of six normally hearing subjects who had previously received 12 to 33 h of tactile-alone word recognition training and had learned an average vocabulary of 50 words [Galvin et al., J. Acoust. Soc. Am. 106, 1084-1089 (1999)]. The tactile-alone evaluation contexts were sentences, unfamiliar talkers, and untrained words. The tactile-visual evaluation contexts were closed-set words, open-set words, and open-set sentences. Tactile-alone perceptual skills were generalized to unfamiliar speakers, sentences, and untrained words, though scores indicated that generalization was not complete. In contrast, the generalization of skills to tactile-visual contexts was minimal or absent. The potential value of tactile-alone training for hearing-impaired users of the Tickle Talker is discussed.

Adult↗

A 4-year investigation into phonetic inventory development in young cochlear implant users.

Phonetic inventories of 9 children with profoundly impaired hearing who used the 22-electrode cochlear implant (Cochlear Limited) were monitored before implantation and during the first 4 years of implant use. All children were 5 years old or younger at the time of implant. Spontaneous speech samples were collected at regular intervals for each child and analyzed to investigate phone acquisition over the post-implant period. Acquisition was measured using two different criteria. The "targetless" criterion required the child to produce a phonetically recognizable sound spontaneously, and the "target" criterion required the child to produce the phone correctly at least 50% of the time in meaningful words. At 4 years post-implant, 40 out of 44 phones (91 %) had reached the targetless criterion, and 29 phones (66%) had reached the target criterion for 5 or more of the children. Over the time of the study 100% of monophthongs, 63% of diphthongs, and 54% of consonants reached the target criterion. The average time taken for a phone to progress from the targetless to target criterion was 15 months. Overall, the data suggest trends in the order of phone acquisition similar to those of normally hearing children, although the process of acquisition occurred at a slower rate.

Child, Preschool↗

A comparison of Tactaid II+ and Tactaid 7 use by adults with a profound hearing impairment.

OBJECTIVE: To evaluate and compare use of the Tactaid II+ and the Tactaid 7, in terms of speech perception, by adults with a hearing impairment. DESIGN: Eight adults used one device daily for approximately 10 wk and attended seven training sessions. Performance was measured with tests of phonetic contrast perception, closed-set vowel and consonant identification, word and phoneme recognition in monosyllabic word lists, word recognition in sentences and speechtracking rate. A questionnaire was also administered. The protocol was repeated with the alternative device. RESULTS: With each device, the group discriminated most phonetic contrasts at better-than-chance levels and demonstrated somewhat enhanced visual or auditory-visual perception when measured in terms of vowel identification, monosyllabic word recognition and speechtracking rate. An increase in speechtracking rate was also demonstrated for some individuals. Subjects generally reported little subjective improvement in speech perception and production, but were satisfied with the physical attributes of each device. Five of six subjects preferred the Tactaid 7. CONCLUSIONS: The Tactaid II+ and the Tactaid 7 provided suprasegmental and segmental information, enabling the group to discriminate phonetic contrasts and improve their perception of some speech materials. No consistent advantage was found for either device, thought most subjects preferred the Tactaid 7. Alternatives likely to provide a greater benefit to communication should be considered before a Tactaid fitting.

Acoustic Stimulation↗

Acquisition of a tactile-alone vocabulary by normally hearing users of the Tickle Talker.

Tactile-alone word recognition training was provided to six normally hearing users of the Tickle Talker, an electrotactile speech perception device. A mean group tactile-alone vocabulary of 31 words was learned in 12 h of training. These results were comparable to, or superior to, those reported for other tactile devices and Tadoma. With increased training the group became faster at learning tactually new words, which were introduced in small training sets. However, as their tactile-alone vocabulary grew, subjects required more training time to reach the pass criterion when evaluated on their recognition of their whole vocabulary list. A maximum possible vocabulary size was not established. The application of tactile-alone training with hearing-impaired users of the device is discussed.

Adult↗

The effect of language knowledge on speech perception: what are we really assessing?

OBJECTIVE: The authors examined whether open-set speech perception scores are limited by knowledge of vocabulary and syntax and further considered whether remediation of vocabulary and syntax will increase open-set speech perception scores. STUDY DESIGN: This was a repeated-measures study design in the setting of a primary (elementary) school for the hearing-impaired. PATIENTS: The study population was composed of three hearing-impaired children using Nucleus 22-channel cochlear implant. INTERVENTION: Intervention used was language remediation sessions. MAIN OUTCOME MEASURES: The main outcome measures were assessment of auditory-alone speech perception benefit using open-set words and sentences and assessment of syntactic knowledge using the Test of Syntactic Ability. Outcome measures were applied before and after remediation. RESULTS: Child 1 and child 2 showed a significant postremediation improvement in their overall scores on the Test of Syntactic Ability and in their ability to perceive words learned during remediation. Child 1 and child 2 also showed a significant improvement in their scores on a modified Bamford-Kowal-Bench open-set sentence test, which specifically targeted grammatical constructs trained in remediation sessions. CONCLUSIONS: Remediation of language knowledge deficits significantly improved open-set speech perception for two children, suggesting a need to include language remediation in cochlear implant habilitation programs.

Adolescent↗

Pitch comparisons of acoustically and electrically evoked auditory sensations.

Cochlear implant users with some residual hearing in the non-implanted ear compared the pitch sensations produced by acoustic pure tones and pulsatile electric stimuli. Pitch comparisons were obtained for pure tones and electrical stimuli presented at different positions (electrodes) in the scala tympani, keeping the electric pulse rate fixed at 100, 250, or 800 pps. Similarly, pitch comparisons were obtained for electrical stimuli with variable pulse rates presented to two fixed electrode positions (apical and basal) in the cochlea. Both electrode position and pulse rate influenced the perceived pitch of the electrical signal and 'matched' electric and acoustic signals were found over a wide range of frequencies. There was a large variation between listeners. For some stimuli, listeners had difficulty in deciding whether the acoustic or electric stimulus was higher in pitch. Despite the variability, consistent trends were obtained from the data: higher frequencies tended to be matched by more basal electrodes for all pulse rates. Higher frequencies tended to be matched by higher pulse rates for both electrode positions. The electrode positions that 'matched' pure tones were more basal than predicted from the characteristic frequency coordinates of the basilar membrane in a normal human cochlea.

Acoustic Stimulation↗

Articulation accuracy of children using an electrotactile speech processor.

OBJECTIVE: Use of wearable tactile speech perception devices is suggested to help overcome the difficulties in speech production resulting from severe and profound hearing impairment in children. This suggestion is based on the assumption that subjects can use tactile input in isolation, or in combination with information from residual aided hearing, to monitor and modify their speech. The present study evaluated the benefits to articulation provided through use of a multichannel electrotactile device ("Tickle Talker"). DESIGN: Six profoundly hearing-impaired children were videotaped speaking with the Tickle Talker on and with the Tickle Talker off during conversations with their audiologist. Five of the subjects also wore their binaural hearing aids during all recorded conversations. The number of vowels, consonants, and overall phonemes correctly articulated by each child in the two conditions were compared. RESULTS: One subject improved articulation of initial consonants and initial phonemes; one subject improved articulation of total vowels, total consonants, initial consonants, total phonemes, and initial phonemes; and a third subject improved articulation of total vowels and medial phonemes. CONCLUSIONS: Use of on-line tactile feedback from the Tickle Talker may benefit the articulation accuracy of some children, and the device may therefore be suitable to use with children who have not responded to more traditional speech training techniques.

Adolescent↗

A clinical report on receptive vocabulary skills in cochlear implant users.

OBJECTIVES: The aim was to measure the rate of vocabulary acquisition for cochlear implant users and compare the pre- and postoperative rates with published data for other groups with normal or impaired hearing. The hypothesis was that the postoperative rate would be greater than the preoperative rate. DESIGN: The Peabody Picture Vocabulary Test (PPVT) was administered to 32 children, adolescents, and prelinguistically deafened adults implanted with the 22-electrode cochlear implant. Age at implantation ranged from 2 yr 6 mo to 20 yr and implant use ranged from 6 mo to 7 yr 8 mo. RESULTS: The group mean postoperative performance at various postoperative intervals was significantly higher than mean preoperative performance. Single-subject data indicated statistically significant gains over time on this test for 13 of the subjects. The mean postoperative rate of vocabulary acquisition of 1.06 times the rate for normally hearing children was significantly greater than the mean preoperative rate of 0.43. CONCLUSION: These rates of improvement were in accord with previous reports on smaller numbers of implant users, but could not be attributed unambiguously to use of the implant because no control group was used for this clinical work. Variables such as age at implantation, duration of profound deafness, communication mode, and speech perception skill failed to significantly predict rate of improvement of the PPVT.

Adolescent↗

A clinical report on speech production of cochlear implant users.

OBJECTIVE: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. DESIGN: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. RESULTS: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. CONCLUSIONS: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.

Adolescent↗