P Grigoris

Publications and source records attributed to P Grigoris.

32 records · Page 2Linked to original sources

Long-term results of transtrochanteric rotational osteotomy for femoral head osteonecrosis.

Twenty transtrochanteric rotational osteotomies were performed in 19 patients with osteonecrosis of the femoral head (average age 32 years; range 19-55 years). There were 17 hips at Ficat stage III and three at stage IV. The average head rotation achieved was 70 degrees (range 55 degrees-95 degrees) Fourteen hips were converted to a total hip arthroplasty after an average period of 5.6 years (range 1.5-12.7 years). Five hips have maintained a good clinical result and normal function for an average period of 11.3 years (range 9.2-13.5 years). One patient with an ankylosed hip was lost to follow-up at 3.5 years. All hips with incomplete rotation of the necrotic fragment out of the weight-bearing area were revised to total hip arthroplasties. All unrevised hips had radiographic evidence of mild to moderate osteoarthritis. Total hip arthroplasty was deferred for a modest period in most patients, and conversion was performed without difficulty. However, we no longer advocate transtrochanteric rotational osteotomy because of unpredictable results and technical difficulties, especially with large lesions.

Adult↗

Metal on metal bearings in hip arthroplasty.

Periprosthetic osteolysis caused by wear debris released from the bearing surface of polyethylene components is the major problem in contemporary hip arthroplasty. Several types of metal on metal prostheses were developed in the 1960s, but by the mid 1970s they were completely displaced by polyethylene bearings. There have been several generations of all metal components with significant variation in design, tolerances, and bearing surface quality. A number of these hips have survived for more than 25 years because of low wear rates and minimal osteolysis. Identification of the characteristics that contributed to long term function is important. The historical development and clinical results of metal on metal hip arthroplasties are presented. Factors that led to the abandonment of the metal on metal bearings are related to: (1) the early success of the Charnley prosthesis; (2) the frictional torque issue; (3) carcinogenesis concerns; (4) metal sensitivity concerns; (5) high infection rates; and (6) increased strain rates in periprosthetic bone and fatigue fractures of the acetabular floor. The accumulated experience to date enables one to evaluate all the factors with a different perspective and makes the use of newer metal on metal bearings a viable option in younger patients.

Adult↗

In vivo wear of three types of metal on metal hip prostheses during two decades of use.

Wear was analyzed on 21 metal on metal hip replacements, including McKee-Farrar, Müller, and Ring, that were retrieved from patients after as many as 25 years. Light and scanning electron microscopy indicated that early wear included substantial third body abrasion, possibly from particles generated while scratches from the original polishing were being eradicated and from dislodged surface carbides. However, the main contact zones were eventually worn smoother than the original surfaces. Wear was quantified by digitizing the shapes of the components on a coordinate measuring machine and identifying those areas that deviated from the original spheric surface. On the femoral heads, wear was typically concentrated in the superomedial region, that is, on the load axis. Three cases also had substantial wear inferiorly, but there were no cases with circumferential (equatorial) wear. The long term wear rates averaged approximately 6 micrometers per year or less and produced an average of approximately 6 mm3 of metallic wear debris per year or less. Wear rate tended to increase as clearance increased over the range of 127 to 386 micrometers, and a McKee-Farrar prosthesis with the extreme clearance of 1.7 mm wore approximately 16 times faster than the average, but there was no apparent relationship between clearance and time to revision. Larger McKee-Farrar balls had less volumetric wear, on average, than smaller balls, and the Müller balls had the greatest wear, which may have been due to contact with the edges of recesses machined into the bearing zones of the Müller cups.

Biomechanical Phenomena↗

Articular muscle of the knee: a muscle seldom recognized on MR imaging.

OBJECTIVE: We studied the MR imaging characteristics of the articular muscle of the knee, an important but seldom recognized structure of the distal thigh and knee. SUBJECTS AND METHODS: We used a 1.5-T system to prospectively evaluate the articular muscle of the knee in five healthy volunteers (10 knees); then we retrospectively studied the knee examinations of 24 patients (30 knees). One reader made duplicate readings to prospectively assess the sagittal proton density-weighted and axial T1-weighted images of the healthy volunteers. Three independent readers retrospectively evaluated the sagittal proton density-weighted images of the 24 patients. RESULTS: The articular muscle of the knee was identified in 100% of prospective studies (10/10) and in 83% of retrospective studies (25/30). For the prospective study group, measurements (mean +/- SEM) were as follows: number of bundles, 2.4 +/- 0.68 (range, 1-4); length of uppermost bundle, 47.2 +/- 4.06 mm; width of origin, 8.6 +/- 0.79 mm; angle of origin, 11.4 degree +/- 1.29 degree; and cross-sectional bundle width, 19.8 +/- 2.05 mm2. CONCLUSION: The articular muscle of the knee can usually be identified by MR imaging as an independent entity, separate from the great (vastus) muscle group.

Adolescent↗

Endoprostheses for osteonecrosis of the femoral head. A comparison of four models in young patients.

Eighty-eight hip arthroplasties were carried out in 75 patients, all aged 50 years or less, with osteonecrosis. All the operations were carried out by one surgeon. Four different methods were used: a standard cemented arthroplasty; a cemented THARIES surface replacement; an uncemented surface replacement; a cemented titanium femoral surface hemiarthroplasty. Comparable clinical improvement occurred in all 4 groups initially. Aseptic loosening, with intersurface degradation and osteolytic lesions, was the most common cause of failure in the 3 types which had a polythene bearing. Polyethylene is the major contributor to bone loss around the endoprosthesis and loosening. Fixation of the surface hemiarthroplasty remained intact in every patient and failure was secondary to wear of the acetabular cartilage. We recommend surface hemiarthroplasty as an interim solution for young patients with stage III or early stage IV osteonecrosis because this procedure conserves bone stock, there is little osteolysis and it can easily be revised.

Adolescent↗

The origin of submicron polyethylene wear debris in total hip arthroplasty.

The microscopic morphology of worn polyethylene surfaces was compared with that of the associated polyethylene particles for acetabular cups tested in a wear simulator and for cups worn in vivo, using scanning electron microscopy. In the absence of significant third-body abrasive damage, the articulation of the ball in the cup produced a visually polished surface on the polyethylene. On a micron scale, the morphology of the worn polyethylene from in vitro and in vivo wear included nodules and fibrils consistent with adhesive, abrasive, and microfatigue wear mechanisms. Larger wear features, such as deep scratches or pits measuring in 10s of microns, that were seen in the in vivo cups were attributed to third-body wear. The polyethylene particles isolated from the serum lubricants of the wear tests and from the periprosthetic tissues were primarily submicron in size, were either rounded or elongated, and were consistent with the submicron wear features seen on the cup surfaces. It is the submicron particles that are associated with inflammatory periprosthetic bone loss in total hip replacement. Although the mean dimensions of the particles generated in vitro were slightly smaller than those of the in vivo particles, the overall morphologies were very comparable, suggesting that the same lubrication and wear processes were acting in the simulator as in vivo.

Foreign Bodies↗

Tripolar hip replacement for recurrent prosthetic dislocation.

An innovative treatment is described for unstable total hip arthroplasty that uses a large inside diameter acetabular cup and a bipolar femoral head sized to approximate the diameter of the normal hip. Eight consecutive patients with recurrent prosthetic dislocations were treated with this tripolar hip. Joint stability was achieved in all patients, who have an average of 4.2-years' followup (range, 2.6-6.3 years).

Adolescent↗

Dislocation of a total hip arthroplasty caused by iliopsoas tendon displacement.

The iliopsoas tendon was caught behind the prosthetic neck after an early anterior dislocation of a revised total hip arthroplasty. The displaced tendon caused instability with successive dislocations that necessitated open reduction. The diagnosis of iliopsoas tendon interposition should be suspected when an early anterior dislocation of a total hip arthroplasty is followed by a concentric reduction and a dramatic change in stability.

Female↗

Precision-fit surface hemiarthroplasty for femoral head osteonecrosis. Long-term results.

Cemented Ti-6Al-4V components were used to resurface ten femoral heads in nine young adult patients with osteonecrosis of the femoral head (average age 32 years; range 20 to 51). There were eight hips at Ficat stage III and two at stage IV. Five hips have maintained satisfactory function for an average period of 11.2 years (10 to 12.2) with no radiographic evidence of component loosening or osteolysis; five have been revised after an average period of 7.8 years (3.3 to 10.3) for pain caused by deterioration of the acetabular cartilage. No component required revision for loosening and the specimens retrieved at revision showed no evidence of osteolysis despite burnishing of the titanium bearing surface and the presence of particulate titanium debris in the tissues.

Adult↗

Failure of uncemented polyethylene acetabular components.

The authors describe the mode of failure of the Ring UPM (Downs Brothers, Surrey, United Kingdom) uncemented metal-on-plastic total hip arthroplasty. Erosion of the external surface of the uncemented acetabular cup led to early loosening in eight cases. The subsequent production of large quantities of polyethylene debris caused massive granulomata, resulting in osteolysis of the acetabulum and femur. Revision surgery was difficult because of the loss of bone stock. The serious consequences of failure of this design lead to the conclusion that uncemented, nonmetal-backed polyethylene acetabular components should not be used.

Acetabulum↗

A technique for removing an intrapelvic acetabular cup.

We describe a simple, retroperitoneal approach for the removal of acetabular components that have migrated into the pelvis. The dense fibrous tissue layer which surrounds the implant protects the iliac vessels during removal of the cup by this method.

Acetabulum↗

White cell scans and infected joint replacements. Failure to detect chronic infection.

We report the results of imaging with labelled white cells in 52 patients before the revision of 54 cemented joint prostheses at which the diagnosis of infection was made from biopsies. Twenty-five hips were imaged with 111In-oxine-labelled cells; 20 hips and 11 knees were imaged with 99mTc-hexamethylpropylene-amineoxime-labelled cells. Of these, 13 hips and five knees proved to be infected. The scans taken together had an accuracy of 82%, a sensitivity of 44% and a specificity of 100%. Indium scans gave 37% sensitivity, 99mTc labelling 50% sensitivity. Infected arthroplasties with positive scans had presented significantly earlier than those with negative scans, the time after the original insertion being 1.1 years for the true-positive scans and 6.1 years for the false-negative scans. The value of labelled white-cell scans in the detection of infection in failed joint replacements is dependent on the activity of the infection. There is reduced sensitivity to the more insidious infections which affect arthroplasties and aspiration under controlled conditions remains an important investigation.

Biopsy, Needle↗