Search PubMed⌕ Search

Biomedical subjects

P Fulford

Publications and source records attributed to P Fulford.

13 recordsLinked to original sources

Management of acute nontraumatic upper limb ischemia.

A retrospective review of all patients presenting to a tertiary referral center with acute nontraumatic upper limb ischemia between January 1992 and June 1997 was undertaken to examine the role of intraarterial thrombolysis in the management of such cases. Twenty-one patients were identified in the radiology and vascular surgery departments' registers. Twenty (95%) underwent angiography, demonstrating subclavian artery occlusion in four, axillary in two, brachial in 13, and one at the digital level. Intraarterial thrombolysis was attempted in 12 patients. There were three technical failures, all requiring embolectomy. Six had complete lysis and resolution of their symptoms. One patient had partial lysis but experienced no further rest pain. Thrombolysis was unsuccessful in two cases with one subsequently requiring embolectomy and the other surgical bypass. Three patients had surgical intervention as their primary procedure with two favorable outcomes and one ending in above-elbow amputation. Five patients were treated conservatively with heparin, resulting in three partial and two full recoveries. One patient experienced complete resolution of symptoms with an intravenous prostacyclin infusion. Both electrocardiograms (ECG) and echocardiograms (ECHO) were of limited diagnostic aid, and long-term warfarin anticoagulation was prescribed to all patients. There was no recurrence of upper limb ischemia at a median follow up of 18 months. Intraarterial thrombolysis is an effective first line treatment for acute nontraumatic upper limb ischemia in selected cases.

Acute Disease↗

Ruptured infected popliteal artery aneurysm.

We describe an unusual presentation of an infected popliteal aneurysm. To our knowledge rupture of an aneurysm associated with Salmonella at this site has not previously been reported. The management of infected aneurysms is discussed.

Aged↗

Art--or science?

Explore the source record for details and available documents.

Humans↗

Loosening of the femoral component after total hip replacement. The thin black line and the sinking hip.

Review of the radiographs of 882 consecutive metal-to-polyethylene hip replacements after a mean follow-up of 6.8 years showed 72 cases (8%) of aseptic femoral loosening, all of which showed a lucent zone or black line between metal and cement. In 97% of the series this appeared within two years of the arthroplasty. Progress of loosening was unpredictable and only 24% had significant symptoms. Improved technique with methylmethacrylate cement in Stanmore prostheses had reduced loosening after two years from 7.9% to 0.4%. Methods of detection of early loosening are discussed.

Follow-Up Studies↗

Assessment of the Denham knee replacement. Results after eight years.

The Denham knee replacement is a relatively simple unconstrained prosthesis. The design ensures good alignment and full extension, but does not allow flexion beyond 90 degrees or tibiofemoral rotation. The results after eight years' experience have been assessed in four different ways in over 600 cases. They show that for the limited needs of the elderly arthritic patient, the Denham arthroplasty provides a high proportion of satisfactory results with an unusually low rate of late failure.

Adult↗