Coronary calcium, as determined by electron beam computed tomography, and coronary disease on arteriogram. Effect of patient's sex on diagnosis.

BACKGROUND: Coronary artery calcium identified by electron beam computed tomography (EBCT) has potential for noninvasive localization of coronary atherosclerotic disease. However, the effect of a patient's sex on its diagnostic capability has not been examined in a clinical population. METHODS AND RESULTS: Fifty women and 89 men had EBCT scans done an average of 1 day after coronary arteriography. Maximum arteriographic percent luminal diameter stenosis of any artery was paired with the total EBCT coronary calcium score for each subject. The women (age, 56 +/- 11 years [mean +/- SD]) were older than the men (age, 47 +/- 7 years), but the subjects were matched for indications for arteriography and extent of disease as assessed by arteriography. Sensitivity, specificity, and positive and negative predictive values for coronary calcium were nearly identical for men and women, regardless of the degree of arteriographic disease. EBCT was highly sensitive to the presence of arteriographic disease (range, 94% to 100%), but had only moderate specificity (57% to 66%) for significant disease (> or = 50% stenosis) and low specificity (35% to 38%) for any arteriographic disease (> 0% stenosis). Negative predictive values in men and women ranged from 79% to 91% for any arteriographic disease and from 95% to 100% for significant disease, respectively. Numerical calcium scores were significantly different between subjects with normal arteriograms and those with significant disease; however, calcium score had limited power to separate trivial, moderate, and significant disease. Receiver operating characteristic curve areas, determined as an extension of the analyses of sensitivity and specificity, were high for EBCT-defined calcium scores for both any arteriographic disease and significant arteriographic disease, and were not different between the sexes. CONCLUSIONS: In a middle-aged population, noninvasive definition of coronary calcium by EBCT has similar predictive value for arteriographic coronary artery disease in men and women.

Calcinosis↗

Measurement of abdominal and visceral fat with computed tomography and dual-energy x-ray absorptiometry.

These studies were undertaken to compare dual-energy x-ray absorptiometry (DXA) and computed tomography (CT) measurements of abdominal fat and to determine whether anthropometry could be combined with DXA to predict intraabdominal (visceral) fat mass in humans. Twenty-one volunteers underwent abdominal CT scans, DXA, and anthropometry. DXA- and CT-measured total abdominal fat were similar (8448 +/- 5005 and 8066 +/- 5354 mL, respectively; NS) and were highly correlated (r = 0.985, P < 0.001). The combination of anthropometry and DXA was a suboptimal predictor of CT-measured intraabdominal fat (r = 0.61, P < 0.05); however, the combination of a single CT slice (to assess the ratio of intraabdominal to total abdominal adipose tissue) and DXA-measured abdominal fat was an excellent predictor of CT-measured intraabdominal fat (r = 0.98, P < 0.001). We conclude that a single-slice CT scan (or other imaging technique) with or without DXA is required for accurate predictions of intraabdominal fat.

Absorptiometry, Photon↗

Pulmonary embolism: diagnosis with contrast-enhanced electron-beam CT and comparison with pulmonary angiography.

PURPOSE: To determine the sensitivity and specificity of contrast material-enhanced electron-beam computed tomography (CT) in the diagnosis of pulmonary embolism (PE). MATERIALS AND METHODS: Sixty patients suspected of having PE were prospectively evaluated with pulmonary angiography and contrast-enhanced electron-beam CT. Thirty-eight patients underwent ventilation-perfusion (V-P [also known as V/Q]) scanning. The pulmonary vasculature was divided into 12 anatomic zones. CT and angiographic findings were correlated on a patient-by-patient basis and for each vascular zone. RESULTS: Both studies were negative for PE in 36 patients. Both studies were positive in 15 patients, with the site of the emboli correlating well. Prospective sensitivity of CT was 65%; specificity, 97%; positive predictive value, 94%; and negative predictive value, 82%. After review of the nine discordant cases, sensitivity and specificity approached 100% for clinically important acute PE. CT depicted central and peripheral emboli equally well. CT was more sensitive and specific than V-P scanning. CONCLUSION: Electron-beam CT is a sensitive and specific noninvasive method for the diagnosis of PE. It has the potential to replace V-P scanning as the primary screening examination for PE.

Humans↗

Electron-beam CT: use of a calibration phantom to reduce variability in calcium quantitation.

PURPOSE: To measure scanner and patient variation in computed tomographic (CT) numbers for electron-beam CT and to determine the ability of calibration phantoms to reduce variability in calcium quantitation. MATERIALS AND METHODS: Two calibration phantoms were imaged to ensure longitudinal homogeneity and to determine the short-term intrascanner variation in CT numbers. Each phantom set was imaged twice a day for 14 weeks to determine intra- and interscanner variation. Data from examinations of 167 patients that included the phantom were analyzed to determine the intra- and interpatient variation in CT numbers of objects with known calcium concentrations. RESULTS: The calibration reduced scanner variations by approximately 25%. The calcium concentration associated with a CT number of 130 HU varied from 77.1 to 136.4 mg/cm3 and was dependent on patient girth, sex, smoking history, and image level. CONCLUSION: Scanner and patient variations in CT numbers in electron-beam CT can be reduced with a calibration phantom. In vitro and in vivo estimates of calcium concentration had a precision of 2% and 7%, respectively.

Adult↗

Effects of body position on the upper airway of patients with obstructive sleep apnea.

Fast-CT scanning was used to study the effects of changes in body position on upper airway (UA) size and shape in 11 awake subjects with obstructive sleep apnea (OSA). Six patients with position (P)-dependent OSA were compared with five patients with nonposition (NP)-dependent OSA. Scans were repeated in the prone (PRN), right side (RS), and supine (SUP) body positions at both functional residual capacity and end-inspiratory tidal volume. Significant group, group by position, and borderline group by respiration effects were detected for minimum but not mean UA dimension data. Significant differences between groups were noted in minimum cross-sectional area and minimum lateral distance but not in minimum anteroposterior distance in the RS and SUP positions. Turning from the PRN to the RS or SUP position tended to decrease UA size in the NP group by decreasing the lateral distance, while the opposite effect was found in the P group. The results indicate that changes in body position during wakefulness affect the lateral but not the anteroposterior dimensions of the UA, and the UA behaves differently in patients with NP and P OSA in response to changes in body position.

Case-Control Studies↗

Renal artery angioplasty: technical results and clinical outcome in 320 patients.

OBJECTIVE: To review the results of percutaneous transluminal renal artery angioplasty (PTRA), including technical success and clinical outcome, at Mayo Clinic Rochester. DESIGN: We retrospectively reviewed our experience with 320 patients who underwent PTRA for stenosis of 396 arteries during a 14-year period. MATERIAL AND METHODS: We reviewed medical records and angiograms of patients who underwent PTRA at Mayo Clinic Rochester between January 1980 and December 1993. The patients were divided into four groups, based on clinical history and angiographic appearance of the stenosing lesion: renal artery atherosclerosis (ASO group), fibromuscular dysplasia (FMD group), previous renal artery bypass or endarterectomy, and renal artery stenosis in a solitary kidney. Technical results of the PTRA were determined by evaluation of angiograms obtained before and after the procedure. Data on patient demographics, blood pressure, antihypertensive medications, and serum creatinine were recorded for the period preceding PTRA, after the procedure, and at last follow-up. RESULTS: All groups had statistically significant reductions in mean arterial pressure and antihypertensive medications after PTRA. The percentage of patients who benefited after renal artery angioplasty was 70% for patients with ASO (8.4% cured), 63% for patients with FMD (22% cured), 53.8% for patients with prior surgical revascularization (23.1% cured), and 91.7% for patients with a solitary kidney (0% cured). No significant overall change in serum creatinine level was noted after the procedure in any group. Complications were comparable to those reported in other studies. The 30-day all-cause mortality rate was 2.2% for the current study, all deaths occurring in the ASO group. CONCLUSION: PTRA rarely leads to a "cure" of renovascular hypertension but provides effective control of blood pressure and decreases the medication requirements in selected patients.

Adult↗

Quantity of coronary artery calcium detected by electron beam computed tomography in asymptomatic subjects and angiographically studied patients.

OBJECTIVE: To determine the prevalence and quantity of coronary artery calcium (CAC) in asymptomatic subjects from the general population, to identify asymptomatic subjects without risk factors for coronary artery disease (CAD) with CAC scores in the top quartile of the distribution, and to compare CAC scores in patients who underwent angiography with percentiles in asymptomatic subjects of the same age and sex. DESIGN: We studied two samples from Rochester, Minnesota, which consisted of 772 asymptomatic subjects from the general population and 145 patients who underwent angiography, all of whom were 20 to 59 years of age. METHODS: Asymptomatic subjects were classified on the basis of their CAD risk profile. All subjects in both study samples underwent electron beam computed tomography. Age- and sex-specific calcium score percentiles were calculated in the asymptomatic sample. RESULTS: CAC prevalence in the asymptomatic subjects was lower in female than in male subjects and increased with advancing age. Of the asymptomatic sample, 8% had a low-risk profile with calcium scores in the top quartile of the distribution. More patients than expected in the angiography sample had calcium scores above the 50th through 95th score percentiles. CONCLUSION: The quantity of CAC was substantially increased in patients who underwent angiography. Subjects with large amounts of CAC but without known CAD risk factors may be a valuable subset of the population to investigate for previously unidentified CAD risk factors.

Adult↗

Relation of coronary calcium determined by electron beam computed tomography and lumen narrowing determined by autopsy.

Coronary calcium determined by electron beam computed tomography (CT) has not been systematically evaluated regarding prediction of histopathologic atherosclerotic disease. Furthermore, gender specificity has not been examined. The 3 major epicardial arteries were dissected from 13 consecutive hearts (5 women and 8 men) after autopsy. Each artery was straightened and scanned using CT in contiguous 3 mm thick cross sections. After imaging, histologic sections were prepared at corresponding intervals and luminal area obstruction determined by planimetry. Electron beam CT scans were analyzed to determine coronary calcium area (i.e., tomographic area with CT density > 130 Hounsfield units). A total of 522 histologic specimens were examined and paired with corresponding CT scans (182 in women, 340 in men). Receiver-operating characteristic (ROC) analysis was used to define site specificity of calcium area for luminal area narrowing by atherosclerosis. ROC curve areas for segmental CT calcium and prediction of atherosclerosis representing mild, moderate, or severe disease were, respectively, 0.712, 0.843, and 0.857 for women and 0.732, 0.793, and 0.841 for men. Curves relating false-positive rate (1-specificity) to predefined degrees of atherosclerotic narrowing versus calcium area were curvilinear. In both women and men, calcium areas on the order of 1 mm2/coronary segment were necessary to predict at least mild atherosclerosis with a false-positive rate of 0% (i.e., 100% specificity), whereas a calcium area > 3 mm2 was necessary to predict the same result for severe disease. In conclusion, coronary artery calcium area as determined by electron beam CT has the potential to predict segmental histopathologic coronary disease.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Quantification of global and regional renal blood flow with electron beam computed tomography.

Alterations in renal blood flow distribution may occur in a variety of pathophysiologic situations; however, quantification of global and regional renal blood flows has been limited because of the lack of reliable, noninvasive techniques. To determine the feasibility of flow measurements with electron-beam computed tomography (EBCT), six anesthetized dogs were scanned by EBCT during basal conditions, after renal vasodilation, and at recovery. Flow (mL/min/cm3 tissue) was calculated from EBCT-derived time-density curves using three different algorithms and compared with simultaneously obtained electromagnetic flow (EMF) probe measurements after indexing to EBCT-derived renal volume. EBCT-determined flow correlated well with EMF measurements regardless of the algorithm used. An algorithm using the area under the time-density curve was concluded to be the most suitable for calculation of renal blood flow; it correlated with EMF as EBCT flow = 44.5 + 1.05 EMF (r = 0.885, SEE = 31.2 mL/min, P < .0001). Consistent overestimation of flow by EBCT resulted probably from retention of contrast media in the renal parenchyma. EMF showed an increase of 20 +/- 10% in renal blood flow after vasodilation. EBCT-derived global, cortical, and medullary flows increased by 33.8 +/- 10.3%, 24.8 +/- 17.8%, and 99.0 +/- 73.8%, respectively. In conclusion, EBCT was found feasible for credible quantitation of renal blood flow in the physiologic range studied.

Algorithms↗

Detection of heart calcification with electron beam CT: interobserver and intraobserver reliability for scoring quantification.

PURPOSE: To assess interobserver and intraobserver reliability of three quantitative measures of coronary artery calcium burden: calcium "score," number of calcified lesions, and calcified area. MATERIALS AND METHODS: Electron beam computed tomographic (CT) scanning was used in a series of 25 patients to detect coronary artery calcification. Scan results were reviewed for quality by a radiologist, then scored by two radiologic technologists and by another radiologist. RESULTS: Many interobserver and intraobserver disagreements were noted on a lesion-by-lesion basis. Since most disagreements involved very small lesions, however, their impact was negligible for all three measures of calcium burden. CONCLUSION: It is not useful for more than one observer to independently score a single CT examination obtained to detect cardiac calcification, even when the arteries are heavily calcified.

Adult↗

Small lesions in the heart identified at electron beam CT: calcification or noise?

PURPOSE: To identify a minimum definition of coronary artery calcification (CAC) at electron beam computed tomography (CT) that would give repeatable results and be accurate as a marker for coronary artery disease. MATERIALS AND METHODS: Hyperattenuating (> 130 HU) foci 0.69-3.09 mm2 in area were evaluated for 256 subjects who underwent two sequential electron beam CT examinations to determine the percentage of hyperattenuating foci seen on a first examination that were seen again on a second examination. Accuracies of varying minimum definitions of CAC were determined in 160 subjects who underwent electron beam CT and coronary arteriography. RESULTS: Hyperattenuating foci more than 2 mm2 in area were seen again at a second examination in more than 50% of cases (P < .0001). At this minimum definition of CAC, the sensitivity and specificity for identifying any angiographically defined coronary artery disease were 82% and 85%, respectively. CONCLUSION: The 2-mm2-area definition of CAC was reliable and provided an accurate indication of coronary artery disease.

Adult↗

Percutaneous adrenal biopsy: review of a 10-year experience.

PURPOSE: To evaluate the indications for and complications, accuracy, and techniques of percutaneous adrenal biopsy performed from 1982 through 1991 at the authors' institution. MATERIALS AND METHODS: Two hundred seventy-seven percutaneous adrenal biopsies were performed in 270 patients (175 male and 102 female patients, aged 31-84 years). Imaging studies and histories were reviewed, and each patient's case was followed up for at least 1 year after the biopsy. A patient was excluded from the study only if follow-up data could not be obtained. RESULTS: The accuracy of percutaneous adrenal biopsy was 90% (249 of 277 biopsies). In the first 5 years of the study, the accuracy was 85% (87 of 102 biopsies); in the latter 5 years it was 93% (163 of 175 biopsies). The sensitivity was 81%, and the specificity was 99%. The positive predictive value was 99%, and the negative predictive value was 80%. The complication rate was 2.8%. CONCLUSION: Percutaneous biopsy is a safe, accurate procedure for the diagnosis of pathologic conditions of the adrenal glands. The most common indication for a biopsy is the presence of an adrenal mass in a patient with lung cancer.

Adrenal Gland Neoplasms↗

Pulmonary embolism: diagnosis with electron-beam CT.

Contrast material-enhanced electron-beam computed tomography (CT) (100-msec scan time) was performed to image the pulmonary vasculature in 86 patients, each suspected of having a pulmonary embolism (PE). Thromboembolic material was demonstrated in 39 patients; no emboli were demonstrated in 47. In 25 patients, angiographic or pathologic proof was available. There were 19 proved positive CT scans, four proved negative scans, one false-negative scan, and one false-positive scan. In the 21 patients with CT and angiographic correlation, evidence of thromboembolic disease was seen in 88 vascular zones. Fifty-three zones were positive for PE at both CT and angiography. Eighteen zones were positive for PE at angiography alone, and 17 zones were positive at CT alone. Electron-beam CT is a potentially effective noninvasive means of diagnosing PE.

Adult↗

Fast-computed tomographic evaluation of the effect of route of breathing on upper airway size and function in normal men.

Nasal obstruction is associated with increased sleep disordered breathing (SDB), even in normal subjects. This increase in SDB may result from narrowing of the orohypopharyngeal (OHP) or retroglossal segment of the upper airway (UA) due to retropositioning of the jaw and tongue base as the mouth is opened and route of breathing changed from nasal to oral. It is postulated that significant narrowing of the OHP occurs with oral breathing even in the awake state. To ascertain the effect of route of breathing on the UA, fast-CT was used to study the UA response to the route of breathing in 30 normal, awake men, with each subject breathing via the nasal and oral routes under the following conditions: end-inspiration during tidal breathing (VTei) and functional residual capacity (FRC). In the velopharyngeal (VP) or retropalatal segment of the UA, minimum (Amin) and mean (Amean) cross-sectional areas (CSA) decreased 49 +/- 11 percent and 16 +/- 6 percent, respectively, with oral compared with nasal breathing at FRC. In the OHP, Amin at FRC increased by 26 +/- 15 percent with oral compared with nasal breathing with no significant change in Amean. Similar changes in CSA of both the VP and OHP were observed at VTei. Genioglossal electromyographic (EMGgg) activity increased from 12 +/- 1 microV breathing nasally to 27 +/- 4 microV breathing orally at FRC. Although the CSA of the VP segment decreased with conversion from nasal to oral breathing, Amin of the OHP segment was unexpectedly observed to increase with oral breathing. The doubling of EMGgg activity with oral breathing suggests that active contraction of the genioglossus may function to increase the patency of the OHP segment during oral breathing in supine, awake, normal subjects.

Adult↗

Noninvasive definition of anatomic coronary artery disease by ultrafast computed tomographic scanning: a quantitative pathologic comparison study.

OBJECTIVES: The aim of this study was to determine the relation between coronary artery calcification detected by ultrafast computed tomographic scanning and histopathologic coronary artery disease. BACKGROUND: Recent studies suggest that discrete coronary artery calcification as visualized by ultrafast computed tomographic scanning may facilitate the noninvasive detection or estimation, or both, of the in situ extent of coronary disease. Such quantitative relations have not been established. METHODS: Thirteen consecutive perfusion-fixed autopsy hearts (from eight male and five female patients aged 17 to 83 years) were scanned by ultrafast computed tomographic scanning in contiguous 3-mm tomographic sections. The major epicardial arteries were dissected free, positioned longitudinally and scanned again in cross section. Coronary artery calcification in a coronary segment was defined as the presence of one or more voxels with a computed tomographic density > 130 Hounsfield units. Each epicardial artery was sectioned longitudinally, stained and measured with a planimeter for quantification of cross-sectional and atherosclerotic plaque areas at 3-mm intervals, corresponding to the computed tomographic scans. A total of 522 paired coronary computed tomographic and histologic sections were studied. RESULTS: Direct relations were found between ultrafast computed tomographic scanning coronary artery calcium burden and atherosclerotic plaque area and percent lumen area stenosis. However, the range for plaque area or percent lumen stenosis, or both, associated with a given calcium burden was broad. Three hundred thirty-one coronary segments showed no calcification by computed tomography. Although atherosclerotic disease was found in several corresponding pathologic specimens, > 97% of these noncalcified segments were associated with nonobstructive disease (< 75% area stenosis); if no calcification was determined in an entire coronary vessel, all corresponding coronary disease was found to be nonobstructive. To determine the relation between arterial calcification and any atheromatous disease, computed tomographic calcium burden for each segment was paired with the histologic absence or presence of disease. Ultrafast computed tomographic scanning had a sensitivity and specificity of 59% and 90% and a negative and positive predictive value of 65% and 87%, respectively. A direct correlation was found (r = 0.99) between total calcium burden calculated from tomographic scans of the heart as a whole and scans of the arteries obtained in cross section. CONCLUSIONS: The detection of coronary calcification by ultrafast computed tomographic scanning is highly predictive of the presence of histopathologic coronary disease, but the use of this technique to define the extent of coronary disease may be limited. However, the absence of coronary calcification at any site is highly specific for the absence of obstructive disease.

Adolescent↗

Coronary artery calcification detected with ultrafast CT as an indication of coronary artery disease.

To assess the relationship of coronary artery calcification to angiographically detectable disease, the authors evaluated 100 patients less than 60 years of age who underwent clinically indicated coronary angiography and ultrafast computed tomography (CT). The ultrafast CT technique consisted of 3-mm-thick contiguous sections and a 100-msec acquisition time. All patients with clinically significant disease at angiography (defined as at least one stenosis with a diameter narrowing of at least 50%) had some coronary artery calcification present at ultrafast CT (100% sensitivity in this population). The absence of calcification at ultrafast CT had a 100% negative predictive value for clinically significant coronary artery disease. Specificity and positive predictive value were 47% and 62%, respectively. Sensitivity and specificity of ultrafast CT in the detection of patients with angiographically detectable disease were 94% and 72%, respectively. Ultrafast CT of the heart is an anatomically based, noninvasive test with high sensitivity for the detection of coronary artery calcification. Ultrafast CT may be beneficial in the screening of selected populations for the presence of atherosclerotic coronary disease.

Adult↗

Fast-computed tomography evaluation of age-related changes in upper airway structure and function in normal men.

The reasons for the increase prevalence of snoring and sleep-disordered breathing in elderly adults are not clear. We hypothesized that age-related reductions in upper airway (UA) size, increased UA collapsibility, and/or inadequate compensatory action of the UA dilator muscles were contributory factors. Fast-computed tomography (CT) was used to examine UA size at FRC and atmospheric pressure, as well as its collapsibility and distensibility in response to negative and positive UA pressures actively generated by the subjects at FRC. The electromyographic activity of the genlogiossal muscle group (EMGgg) was recorded to assess UA dilator muscle response. Thirty adult men with normal overnight polysomnography (mean AHI = 4 +/- 1/h) were studied, and three subgroups of 10 subjects each, young (20-39), middle-age (40-59), and old (60-79), were compared. Unexpectedly, minimal UA cross-sectional area (Amin) at FRC and atmospheric pressure was larger in the old group than in the young group (73 +/- 9 versus 49 +/- 7 mm2, p = 0.04). In response to negative UA pressures of -10 and -50 cm H2O, there were no significant age group differences in Amin, indicating that no age-related increase in UA collapsibility was present. Although no significant difference in tonic EMGgg activity at FRC and atmospheric pressure was detected between groups, the old group demonstrated greater EMGgg activity than did the younger age groups in response to negative UA pressure loading (p less than 0.05). This finding indicated increased compensatory UA dilator muscle activity in response to negative pressures in the older subjects.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Fast-CT evaluation of the effect of lung volume on upper airway size and function in normal men.

The present study was performed to evaluate the regional changes in pharyngeal cross-sectional area (CSA) that occur with changes in lung volume in normal men. Fast-CT and genioglossal electromyogram (EMGgg) were used to study upper airway (UA) size and dilator muscle activity at TLC, lung volume at end-tidal inspiration (VTei), FRC, and residual volume (RV) in 30 men with a mean age of 46 +/- 3 yr and no significant sleep-disordered breathing, mean AHI = 4 +/- 1 per hour. Compared with values at FRC, minimum CSA (Amin) increased 154 +/- 31% at TLC (p = 0.0001), 19 +/- 10% at VTei (p = 0.03), and there was a trend toward a decrease of 31 +/- 12% at RV (p = 0.07). Similar but smaller changes were observed in mean CSA (Amean), with an increase of 69 +/- 14% at TLC (p = 0.0001), 8 +/- 5% at VTei (p = 0.01), and a decrease of 17 +/- 7% at RV (p = 0.01). Both the velopharyngeal (VP) and orohypopharyngeal (OHP) segments of the UA increased in size with increasing lung volume. Both Amin and Amean of the OHP segment at TLC were larger (55 +/- 19 and 38 +/- 14%, respectively) than the respective measurements in the VP segment. EMGgg activity doubled from 12 +/- 1 microV at FRC to 25 +/- 1 microV at TLC (p = 0.006). There was no change in EMGgg with tidal ventilation or with exhalation to RV. Changes in CSA directly paralleled changes in lung volume in this group of normal awake nonobese men.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗