Search PubMed⌕ Search

Biomedical subjects

P F Hahn

Publications and source records attributed to P F Hahn.

At least 19 recordsLinked to original sources

Omental infarct: CT imaging features.

BACKGROUND: The aim of this study is to describe contrast-enhanced computed tomographic (CT) features of acute omental infarction and to study the evolutionary changes on follow-up CT imaging. METHODS: Fifteen cases of omental infarction were evaluated for their initial CT imaging features. The imaging features evaluated included size of the fatty lesion, location, peripheral rim, and relation to colon. CT findings were correlated with etiology, clinical presentation, and leukocytosis. Follow-up CT images were available in eight patients and the imaging features were studied. RESULTS: Eight omental infarcts were of unknown etiology and seven were secondary to abdominal surgery. In 53% of patients (eight of 15), the location of the omental infarct was in the right lower, mid, or upper quadrants. These eight right-side infarcts occurred in six patients with primary omental infarcts. In 13 of 14 patients who underwent CT within 15 days of onset of omental infarct, the margin of the lesion was ill defined. Primary omental (n = 8) infarcts were seen in younger patients (p = 0.02) and were larger on CT (p = 0.02) compared with secondary omental infarcts. CT findings evolved from an ill-defined, heterogeneous fat-density lesion to a well-defined, heterogeneous fat-density lesion with a peripheral hyperdense rim in all six secondary omental infarctions for which acute stage and follow-up CT images were available for interpretation. CONCLUSION: There is a significant difference in the age distribution and CT findings in terms of size of the omental infarction between primary and secondary etiologies. On follow-up CT, secondary omental infarcts progressively shrank and developed a well-defined, hyperdense rim around a fatty core.

Abdomen, Acute↗

Comparison of excretory phase, helical computed tomography with intravenous urography in patients with painless haematuria.

AIM: To compare excretory phase, helical computed tomography (CT) with intravenous (IV) urography for evaluation of the urinary tract in patients with painless haematuria. MATERIALS AND METHODS: Ninety-one out-patients had IV urography followed by helical CT limited to the urinary tract. Both IV urograms and CT images were evaluated for abnormalities of the urinary tract in a blinded, prospective manner. The clinical significance of abnormalities was scored subjectively and receiver operator characteristic curve analysis was performed. RESULTS: In 69 of 91 patients (76%), no cause of haematuria was identified. In 22 of 91 patients (24%), the cause of haematuria was identified as follows: transitional cell cancer of the bladder (n=15), urinary tract stones (n=3), cystitis (n=2), haemorrhagic pyelitis (n=1) and benign ureteral stricture (n=1). With IV urography, there were 15 true-positive, seven false-negative and three false-positive interpretations. With CT, there were 18 true-positive, four false-negative and two false-positive interpretations. There was no significant difference between IV and CT urography for the significance of the positive interpretations (n=0.47). CONCLUSION: Excretory phase CT urography was comparable with IV urography for evaluation of the urinary tract in patients with painless haematuria. However, the study population did not include any upper tract cancers.

Adult↗

Predictive value of benign percutaneous adrenal biopsies in oncology patients.

PURPOSE: Percutaneous CT guided biopsy is accepted as a safe procedure for the diagnosis of indeterminate adrenal masses in oncologic patients. The purpose of this study was to evaluate the accuracy of a 'negative for tumour' adrenal biopsy in the oncologic patient population by assessing subsequent outcome including clinical course, size and imaging characteristics of the adrenal lesions on follow-up imaging studies and pathological findings at re-biopsy or following adrenal mass resection. MATERIALS AND METHODS: Retrospective analysis of 225 oncological patients (FM, 128;87; age range 33-87 years, mean age 66 years) who had undergone CT guided biopsies of an adrenal mass over a 5-year period was performed. Those patients with a report consistent with 'negative for malignancy' were evaluated by reviewing the medical records for patient demographics, primary malignancy, histology of adrenal tumour, subsequent surgical interventions, repeat adrenal biopsy under image guidance, by open surgery or at autopsy, subsequent abdominal imaging in which the adrenal gland was imaged, and long-term outcome including hospital admissions, or death. RESULTS: Of the 225 CT-guided adrenal biopsies performed, 41 (18%) were negative for neoplasm. The primary neoplasm in these 41 patients included lung cancer (n=32), breast (n=5), renal cell carcinoma (n=2), bladder (n=1), and prostate (n=1). The size of the adrenal lesions ranged from 2.8-5 cm. Of the 41 biopsies, which were negative for tumour; 10 were identified as adenomas and the rest showed benign adrenal cortical cells or hyperplasia on cytopathology and histopathology. Repeat biopsies were obtained in 13/41 (31%) patients; whereas 2/41 (5%) had their adrenal gland analyzed on post mortem examination. None of these 15 repeat evaluations yielded tumour. CONCLUSION: In oncological patients, pathological analysis of tissue samples obtained by CT-guided percutaneous biopsy, suggesting benign aetiology, is reliable and predicts a benign course on long-term follow-up. A negative or benign pathology result for a CT guided percutaneous adrenal biopsy can be regarded as a true negative evaluation in oncological patients with no necessity to repeat the biopsy.

Adenoma↗

Dual contrast enhanced magnetic resonance imaging of the liver with superparamagnetic iron oxide followed by gadolinium for lesion detection and characterization.

AIM: Iron oxide contrast agents are useful for lesion detection, and extracellular gadolinium chelates are advocated for lesion characterization. We undertook a study to determine if dual contrast enhanced liver imaging with sequential use of ferumoxides particles and gadolinium (Gd)-DTPA can be performed in the same imaging protocol. MATERIALS AND METHODS: Sixteen patients underwent dual contrast magnetic resonance imaging (MRI) of the liver for evaluation of known/suspected focal lesions which included, metastases (n = 5), hepatocellular carcinoma (HCC;n = 3), cholangiocharcinoma(n = 1) and focal nodular hyperplasia (FNH;n = 3). Pre- and post-iron oxide T1-weighted gradient recalled echo (GRE) and T2-weighted fast spin echo (FSE) sequences were obtained, followed by post-Gd-DTPA (0.1 mmol/kg) multi-phase dynamic T1-weighted out-of-phase GRE imaging. Images were analysed in a blinded fashion by three experts using a three-point scoring system for lesion conspicuity on pre- and post-iron oxide T1 images as well as for reader's confidence in characterizing liver lesions on post Gd-DTPA T1 images. RESULTS: No statistically significant difference in lesion conspicuity was observed on pre- and post-iron oxide T1-GRE images in this small study cohort. The presence of iron oxide did not appreciably diminish image quality of post-gadolinium sequences and did not prevent characterization of liver lesions. CONCLUSION: Our results suggest that characterization of focal liver lesion with Gd-enhanced liver MRI is still possible following iron oxide enhanced imaging.Kubaska, S.et al. (2001). Clinical Radiology, 56, 410-415

Adult↗

MRI contrast agents for evaluating focal hepatic lesions.

Contrast-enhanced magnetic resonance imaging (MRI) has become an important tool in the detection and characterization of focal hepatic lesions especially when other investigations such as ultrasound (US) and computed tomography (CT) are inconclusive. The purpose of this pictorial review is to briefly summarize the properties of various MRI contrast agents used in hepatic imaging and to highlight their role in evaluation of focal hepatic lesions.

Contrast Media↗

Nonvascular interventional procedures: analysis of a 10-year database containing more than 21,000 cases.

PURPOSE: To analyze all procedures performed during 10 years in a nonvascular interventional practice. MATERIALS AND METHODS: Date, organ location, and type of all 21,324 procedures performed between October 1990 and September 2000 were recorded in a database; also included were patient age and inpatient or outpatient status. Because genitourinary procedures were not included during the first 4 years, nephrostomies were added retrospectively. Yearly interventional caseload was compared with the department caseload and the assignment of new medical record numbers. Trends in individual procedure location and type were analyzed, as well as patient age, inpatient status, daily caseloads, and day of the week when the procedure was performed. RESULTS: Caseloads have increased 10.8% per year, exceeding increases in radiology department and hospital activity. Abdomen, outside of a specific organ, was the most common location; catheter deployment was the most common procedure. Abscess drainage, placement of chest tubes, and nephrostomies have increased, but biliary drainages have decreased. Inpatients outnumbered outpatients in all years except 1995, but the trend was toward an increase in the proportion of outpatients. The average patient was 59.6 years old, with average age diminishing. Friday was the busiest day, but weekend procedures have increased. CONCLUSION: Nonvascular interventional procedures have increased, with more currently being performed on weekends.

Databases, Factual↗

CT colonography with teleradiology: effect of lossy wavelet compression on polyp detection--initial observations.

PURPOSE: To assess the consequences of lossy compression on the diagnostic accuracy of CT colonography for detecting colonic polyps. MATERIALS AND METHODS: Helical CT images of cleansed colonic segments were evaluated. Source images were compressed to 1:1, 10:1, and 20:1 ratios with lossy wavelet compression. Two independent readers blinded to corresponding colonoscopic results analyzed 144 randomly ordered colonic segments in multiplanar and volume-rendered endoscopic views. Sensitivity, specificity, and receiver operating characteristic curves were generated for each compression ratio on the basis of expressed confidence in lesion presence. Similar analyses were performed to assess distention and bowel preparation adequacy and evaluation time required. RESULTS: Results based on video colonoscopy-confirmed lesions revealed 100% (four of four) sensitivity for lesions larger than 10 mm for compression ratios 1:1, 10:1, and 20:1 for both readers; sensitivities for all lesions smaller than 10 mm were 50%-78%, 38%-67%, and 38%-67% for respective ratios for both readers. Differences in diagnostic performance for each reader across ratios were not significant (P =.30-.99, McNemar test). The time required to evaluate and assess bowel preparation and distention adequacy did not change significantly across ratios. CONCLUSION: On the basis of the patient sample, lossy compression of transverse source images to at least a 20:1 ratio did not adversely affect diagnostic performance or evaluation time for CT colonography.

Aged↗

Tunneled peritoneal catheter placement under sonographic and fluoroscopic guidance in the palliative treatment of malignant ascites.

OBJECTIVE: We present a treatment for recurrent, symptomatic ascites in patients with malignant disease. This report summarizes our experience with percutaneous tunneled peritoneal catheters in 24 patients. SUBJECTS AND METHODS: Of the 40 consecutive patients who presented with at least four therapeutic paracenteses in a 4-week period, 24 patients underwent the percutaneous tunneled procedure. All had malignant ascites. RESULTS: All 24 patients had successful insertion of a permanent tunneled peritoneal drainage catheter. Eighteen were outpatients and six were inpatients. All patients were relieved of their clinical symptoms, including abdominal distention and dyspnea, and were relieved of lower extremity discomfort. The mean life span after catheter placement was 7.2 weeks. Twenty (83%) of the 24 patients were treated at home with their catheters in place. Three patients experienced minor complications from bacterial peritonitis, which responded to antibiotics. One patient had to have his catheter removed. CONCLUSION: Percutaneous placement of specialized tunneled catheters appears to be a viable and safe technique in patients who have symptomatic ascites that require frequent therapeutic paracentesis for relief of symptoms.

Adult↗

The clinical value of ferric ammonium citrate: a positive oral contrast agent for T1-weighted MR imaging of the upper abdomen.

This study was undertaken to determine whether ferric ammonium citrate (FAC), a positive magnetic resonance (MR) contrast agent, is of clinical value in demonstrating or excluding pathology of the upper gastrointestinal tract. A retrospective review was performed of pre- and post-FAC studies of MR examinations in 203 patients from phase II and III clinical trials in whom final diagnoses had been established based on the results of biopsy, surgery, or independent imaging procedures. Two independent reviewers made randomized and blinded assessments of the stomach, duodenum, and pancreas. FAC significantly increased the certainty of diagnosis for normal studies of the stomach and duodenum for both readers (P < 0.001) and for abnormal studies of the stomach for one reader (P = 0.004). FAC also significantly increased the certainty of diagnosis for normal pancreas for one reader (P < 0.001). FAC significantly (P < 0.001) increased accuracy and specificity for diagnoses involving the stomach and duodenum for both readers and for one reader for the pancreas. There was significant improvement in sensitivity for gastric diagnoses (P = 0.013) for one reader but not for the duodenum or pancreas. We conclude that FAC is helpful in demonstrating and excluding upper gastrointestinal pathology on MR.

Administration, Oral↗

Multicentre dose-ranging study on the efficacy of USPIO ferumoxtran-10 for liver MR imaging.

AIM: A dose ranging multicentre phase-II clinical trial was conducted to evaluate the efficacy of ultrasmall superparamagnetic iron oxide (USPIO) ferumoxtran-10 for magnetic resonance (MR) imaging of focal hepatic lesions. MATERIAL AND METHODS: Ninety-nine patients with focal liver lesions received USPIO at a dose of 0.8 (n = 35), 1.1 (n = 32), or 1.7 (n = 32) mg Fe/kg. Liver MR imaging was performed before and after USPIO with T1-weighted and T2-weighted pulse sequences. Images were analysed by two independent readers for additional information (lesion detection, exclusion, characterization and patient management). Signal intensity (SI) based quantitative measurements were also taken. RESULTS: Post-contrast medium MR imaging showed additional information in 71/97 patients (73%) for reader one and 83/96 patients (86%) for reader two. The results with all three doses were statistically significant (P < 0.05). Signal intensity analysis revealed that all three doses increased liver SI on T1-weighted images and decreased liver SI on T2-weighted images. On T2-weighted images metastases increased in contrast relative to normal hepatic parenchyma whereas haemangiomas decreased in contrast. On T2-weighted images there was statistically improved efficacy at the intermediate dose, which did not improve at the highest dose. CONCLUSION: Ultrasmall superparamagnetic iron oxide was an effective contrast agent for liver MR imaging at all doses and a dose of 1.1 mg Fe/kg was recommended for future clinical trials.

Adult↗

Characterization of indeterminate (lipid-poor) adrenal masses: use of washout characteristics at contrast-enhanced CT.

PURPOSE: To determine whether computed tomographic (CT) scans and attenuation measurements on contrast material-enhanced and nonenhanced CT scans could be used to characterize adrenal masses, in particular, to characterize these lesions by using adrenal washout characteristics at contrast-enhanced CT. MATERIALS AND METHODS: Eighty-six patients (49 men, 37 women; age range, 29-86 years; mean age, 72 years) with 101 adrenal lesions depicted at contrast-enhanced CT underwent delayed (mean, 9 minutes) enhanced scanning. Seventy-eight patients also underwent nonenhanced CT. Mean diameter of the benign lesions was 2.1 cm (range, 1.0-4.2 cm); mean diameter of the malignant lesions was 2.3 cm (range, 1.0-4.1 cm). Region-of-interest measurements were obtained at nonenhanced, dynamic enhanced, and delayed enhanced CT and were used to calculate a relative percentage washout as follows: 1 - (Hounsfield unit measurement on delayed image / Hounsfield unit measurement on dynamic image) x 100%. RESULTS: Ninety-nine of 101 lesions were correctly characterized as benign or malignant with a relative percentage washout threshold of 50% on delayed scans; benign lesions demonstrated more than 50% washout; and malignant lesions, less than 50% washout. Two benign lesions demonstrating less than 50% washout were characterized as benign by using conventional CT. CONCLUSION: Calculation of relative percentage washout on dynamic and delayed enhanced CT scans may lead to a highly specific test for adrenal lesion characterization, reduce the need for, and possibly obviate, follow-up imaging or biopsy.

Adenoma↗

Addition of gadolinium chelates to heavily T2-weighted MR imaging: limited role in differentiating hepatic hemangiomas from metastases.

OBJECTIVE: The purpose of this study was to determine whether the addition of gadolinium-enhanced imaging to heavily T2-weighted MR imaging of the liver is valuable in differentiating hemangiomas from metastases. The T2 relaxation time was also included in our analysis. SUBJECTS AND METHODS: Fifty-one patients with 52 proven liver lesions (24 hemangiomas and 28 metastases) larger than 1 cm underwent MR imaging at 1.5 T with T2-weighted spin-echo (TR/TE, 3000/80, 160) and gadolinium chelate-enhanced dynamic T1-weighted gradient-recalled echo (80/2.6, 80) pulse sequences. Images were reviewed by observers who were unaware of the patients' clinical history; first, only T2-weighted images were reviewed and then T2-weighted plus dynamic images were reviewed together. The T2 relaxation times were calculated for each lesion. Diagnostic accuracy by each method was compared using receiver operating characteristic analysis. RESULTS: Mean T2 relaxation times were 76 +/- 26 msec for metastases and 133 +/- 25 msec for hemangiomas. The addition of dynamic scanning to the T2-weighted sequence made a statistically significant difference for only one observer (p = 0.03). However, it did not make a statistically significant contribution for either observer when compared with the T2 relaxation time. Although addition of the dynamic images resulted in correct diagnosis of six lesions, three lesions were misdiagnosed after having been correctly characterized on the T2-weighted images alone. CONCLUSION: When optimized T2-weighted images are obtained and the T2 relaxation time is calculated, routine use of gadolinium enhancement for differentiation of hemangiomas from metastases is unnecessary although dynamic scanning is valuable in selected cases.

Adult↗

Efficacy of percutaneous abscess drainage in patients with vancomycin-resistant enterococci.

OBJECTIVE: We reviewed a 4-year experience draining fluid collections infected with vancomycin-resistant enterococci to determine the outcome of percutaneous intervention in patients with this highly resistant and increasingly common organism. MATERIALS AND METHODS: Charts of patients from whom vancomycin-resistant enterococci had been isolated during percutaneous drainage were reviewed to determine patient response to drainage, catheter management, and outcome of treatment. RESULTS: Twenty-one patients underwent percutaneous drainage of 28 fluid collections from which vancomycin-resistant enterococci were isolated, including 16 intraabdominal abscesses, seven biliary or urinary obstructions, and five empyemas. The drainage of 27 (96%) of 28 collections were technically successful. In seven patients, drainage provided the first isolation of vancomycin-resistant enterococci from the patient. Five patients also had blood cultures with positive findings for vancomycin-resistant enterococci, and 14 collections were coinfected with other bacteria or with fungi. Twenty collections (71%) or obstructions were successfully treated with percutaneous drainage. Drainage was unsuccessful in treating eight collections in seven patients. CONCLUSION: Despite high-level antibiotic resistance, fluid collections infected with vancomycin-resistant enterococci can be successfully drained percutaneously, resulting in a favorable likelihood of recovery for patients.

Abscess↗

CT-Guided transgluteal drainage of deep pelvic abscesses in children: selective use as an alternative to transrectal drainage.

OBJECTIVE: The transgluteal approach to abscess drainage through the greater sciatic foramen has been described in adults, but this route has not been as extensively studied in children. We performed CT-guided transgluteal percutaneous abscess drainage in seven children and assessed the results of drainage and catheter tolerance. CONCLUSION: Transgluteal catheters are well tolerated by children, and the transgluteal route is an effective approach to selected pelvic abscesses in children.

Abdominal Abscess↗