Search PubMed⌕ Search

Biomedical subjects

P E Krumpe

Publications and source records attributed to P E Krumpe.

At least 19 recordsLinked to original sources

Intravenous and oral mono- or combination-therapy in the treatment of severe infections: ciprofloxacin versus standard antibiotic therapy. Ciprofloxacin Study Group.

Five hundred and forty patients with severe infection were enrolled in a multicentre, prospective, randomized, non-blinded study to compare the efficacy and safety of i.v. ciprofloxacin with i.v. standard therapy. Five hundred and thirty-one patients received at least one dose of study drug for pneumonia (310), septicaemia (112) or skin and skin structure infection (109). Intravenous ciprofloxacin (400 mg, every 8 h) or i.v. ciprofloxacin (400 mg, every 8 h) plus a beta-lactam were compared with a standard monotherapy (beta-lactam) or combination (aminoglycoside plus a beta-lactam) therapy. Patients were treated parenterally for a minimum of 2 or 3 days, then at the discretion of the investigator could be switched to oral therapy (ciprofloxacin 750 mg, every 12 h or a standard oral therapy). Patients were randomized in the ratio of 2:1 for the ciprofloxacin and standard therapy treatment groups and stratified to monotherapy if the APACHE II score was < or = 20 or to combination therapy if the APACHE II score was 21-29. Three hundred and ninety-five (74%) patients were valid for the efficacy analysis: these comprised 242 pneumonia (167 ciprofloxacin and 75 standard therapy), 70 septicaemia (47 ciprofloxacin and 23 standard therapy), and 83 skin infections (56 ciprofloxacin and 27 standard). The primary efficacy variable was clinical response and the secondary efficacy assessment was bacteriological response at the end of therapy (2 or 3 days after treatment). The mean duration of therapy for patients receiving only i.v. monotherapy or combination therapy was shorter (9-10 days) than for patients receiving sequential i.v./p.o. therapy (14-17 days). At the end of therapy, overall clinical resolution/improvement (success) for monotherapy was 138/166 (83%) for the ciprofloxacin group, compared with 74/87 (85%) for standard-treated patients (95% CI = -11.5% to 7.6%), and for combination therapy the response was 43/51 (84%) for the ciprofloxacin group and 14/20 (70%) for standard-treated patients (95% CI = -6.3% to 34.9%). For pneumonia, the most frequent infection treated, clinical success rates following monotherapy were 85% for ciprofloxacin and 83% for standard-treated patients and 83% for ciprofloxacin compared with 69% for standard-treated patients in the combination therapy group. Bacteriological eradication/presumed eradication following monotherapy was 85/102 (83%) for ciprofloxacin and 31/46 (67%) for standard-treated patients (95% CI = 1.6% to 30.3%), and that for combination therapy was 29/36 (81%) for ciprofloxacin and 7/10 (70%) for standard-treated patients (95% CI = -18.3% to 39.5%). Drug-related adverse events, primarily diarrhoea and nausea, were reported in 22% of ciprofloxacin-treated patients and 20% of standard-treated patients. In summary, ciprofloxacin administered alone or in combination was found to be effective in treating a wide range of severe infections.

Administration, Oral↗

Viscous airflow through a rigid tube with a compliant lining: a simple model for the air-mucus interaction in pulmonary airways.

The respiratory tract of mammals is lined with a layer of mucus, described as viscoelastic semi-solid, above a layer of watery serous fluid. The interaction of these compliant layers with pulmonary airflow plays a major role in lung clearance by two-phase gas-liquid flow and in increased flow resistance in patients with obstructive airway diseases such as cystic fibrosis, chronic bronchitis and asthma. Experiments have shown that such coupled systems of flow-compliant-layers are quite susceptible to sudden shear instabilities, leading to formation of relatively large amplitude waves at the interface. Although these waves enhance the lung clearance by mobilizing the secretions, they increase the flow resistance in airways. The objective of this paper is to understand the basic interaction mechanism between the two media better by studying airflow through a rigid pipe that is lined by a compliant layer. The mathematical model that has been developed for this purpose is capable of explaining some of the published experimental observations. Wave instability theory is applied to the coupled air-mucus system to explore the stability of the interface. The results show that the onset flow speed for the initiation of unstable surface waves, and the resulting wavelength, are both very sensitive to mucus thickness. The model predicts that the instabilities initiate in the form of propagating waves for the elastic mucus where the wave speed is about 40 percent of the flow speed. The wavelength and phase speed to air velocity ratio are shown to increase with increasing mucus thickness.(ABSTRACT TRUNCATED AT 250 WORDS)

Air↗

Approach to the patient with diffuse lung disease.

When evaluating diffuse lung infiltrates, the clinician should place special emphasis on the acuity of symptoms, nonpulmonary complaints and findings, environmental exposures, and risk factors for immunosuppressive diseases. Certain radiographic features, such as the distribution of opacities, hilar adenopathy, Kerley-B lines or pneumothorax, or pulmonary function tests demonstrating air flow limitation also narrow the differential diagnosis. One can direct the subsequent workup based on the narrowed differential diagnosis, the pace of disease, the activity of the ongoing inflammatory-immune process, and the age, overall medical condition, and wishes of the patient. Unless a specific diagnosis (for example, hypersensitivity pneumonitis, the treatment of which is withdrawal of the offending agent) can be made, therapy of noninfectious diffuse lung disease is quite unsatisfactory. Immunosuppressive therapy is indicated to arrest the active inflammatory process with the hope that objective signs of improvement will occur after a 3- to 12-month course. Important areas of basic research in pulmonary fibrosis include cell-cell and cell-matrix interactions in the lung interstitium and delineation of fibroblast biology and cytokine-mediated lung connective tissue pathology. More successful therapies will probably evolve from better understanding of the molecular and cellular biology of the lung fibrogenic process.

Bronchoalveolar Lavage Fluid↗

The aging respiratory system.

In this review article, the effects of old age on lung structure and function are discussed. Changes in lung morphology and biochemistry are correlated with changes in lung mechanics and gas exchange, as well as with the respiratory system's adaptability to the stresses of exercise and sleep. The effects of aging on the lungs' defense mechanisms are related to pulmonary diseases of the elderly.

Adaptation, Physiological↗

Alcohol and the respiratory tract.

Possible mechanisms by which alcohol may adversely affect the respiratory system are considered. Alcohol ingestion impairs glottic reflexes, and alcoholics are predisposed to pneumonias and lung abscesses from aspiration of oropharyngeal bacteria. Alcohol intoxication also increases the frequency of sleep apnea and may result in respiratory failure from oversedation.

Adult↗

Reverse ventilation--perfusion mismatch.

Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a "reversed" ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients.

Female↗

Evaluation of bronchial air leaks by auscultation and phonopneumography.

Bronchial fistulae in communication with atmospheric pressure can be identified by the presence of a squeaking sound heard over the chest wall during a Valsalva maneuver. Furthermore, these leak sounds can help identify the size, location, and communications of the bronchial fistulae. The size of the leak can be inferred by the pitch of the leak sound. Large leaks produce low pitched sounds, smaller leaks (or partially obstructed leaks) produce high pitched squeaks , and multiple leaking sites produce polyphonic leak squeaks . The bronchus responsible for the leak can be identified by cessation of the leak sound during balloon occlusion of the correct bronchial stump. A communication of a bronchial fistula with the chest wall facial plane produces massive subcutaneous emphysema and an early inspiratory click. This click suggests a check valve mechanism of air exiting the leaking bronchus.

Adult↗

The detection and quantification of sleep apnea by tracheal sound recordings.

Tracheal sound recordings and O2 saturation were compared with conventional recordings of respiratory events (thermistors, strain gauges, and O2 saturation) in 14 patients referred for assessment of sleep apnea syndrome. There was no significant difference in the number of respiratory events associated with desaturation recorded during the sleep by the two methods. Tracheal sound recordings were more useful in analyzing the cause of the respiratory event. Hypopnea without desaturation was seen more often with tracheal sound recordings than with the conventional methods. The durations of apneic and hypopneic events were significantly longer when recorded by thermistors and strain gauges than by breath sounds.

Adult↗

Use of an acoustic helium analyzer for measuring lung volumes.

We have evaluated the use of an acoustic gas analyzer (AGA) for the measurement of total lung capacity (TLC) by single-breath helium dilution. The AGA has a rapid response time (0-90% response = 160 ms for 10% He), is linear for helium concentration of 0.1-10%, is stable over a wide range of ambient temperatures, and is small and portable. We plotted the output of the AGA vs. expired lung volume after a vital capacity breath of 10% He. However, since the AGA is sensitive to changes in speed of sound relative to air, the AGA output signal also reports an artifact due to alveolar gases. We corrected for this artifact by replotting a single-breath expiration after a vital capacity breath of room air. Mean alveolar helium concentration (HeA) was then measured by planimetry, using this alveolar gas curve as the base line. TLC was calculated using the HeA from the corrected AGA output and compared with TLC calculated from HeA simultaneously measured using a mass spectrometer (MS). In 12 normal subjects and 9 patients with chronic obstructive pulmonary disease (COPD) TLC-AGA and TLC-MS were compared by linear regression analysis; correlation coefficient (r) was 0.973 for normals and 0.968 for COPD patients (P less than 0.001). This single-breath; estimation of TLC using the corrected signal of the AGA vs. Expired volume seems ideally suited for the measurement of subdivisions of lung volume in field studies.

Acoustics↗

Use of laryngeal sound recordings to monitor apnea.

Laryngeal sounds are produced by air flow across the glottis. We found that apnea could be identified by the cessation of laryngeal sounds during continuous monitoring. We recorded laryngeal sounds using a microphone coupled to a stethoscope head taped to the subject's lateral neck. This signal was conditioned using a commercially available amplifier and displayed on a time-based recorder. Laryngeal sound monitoring of apnea could be useful in sleep studies.

Adult↗