Search PubMed⌕ Search

Biomedical subjects

P Diem

Publications and source records attributed to P Diem.

63 records · Page 4Linked to original sources

Lymphocyte transformation by insulin and insulin-zinc suspensions.

The lymphocyte transformation response to the mitogen phytohaemagglutinin (PHA) was determined in 15 well controlled insulin-dependent diabetics (IDD) with a history of insulin allergy or an acute insulin allergy. There was no significant difference in the PHA response of IDD and normal subjects matched in respect of age and sex. The response of peripheral blood lymphocytes to insulin (Actrapid) and an insulin zinc suspension (Monotard) was also determined. Fifty-three percent of IDD gave a positive reaction to Actrapid. Monotard produced positive reactions both in IDD and normal subjects. In normal subjects, a close correlation between the stimulation indices of Monotard and PHA was found (r = 0 . 966) suggesting that these stimulations depend on a common parameter namely, the reactivity to mitogens.

Adolescent↗

[Hemolytic autoimmune anemia caused by (+)-cyanidanol-3 (Catergen)].

Several episodes of acute intravascular immune hemolysis in a 68 year old patient induced by (+)-cyanidanol-3 (Catergan) are reported. Clinical and serological criteria of the so-called immune-complex mechanism of immune drug-induced hemolysis were realised. The meaning of the additional marked affinity of the drug to the erythrocytic surface remains unclear. The patient's serum was cross-reactive with rutine but not with troxerutine.

Aged↗

[Immunologic studies with fully synthetic human insulin in patients with diabetes mellitus].

A group of 12 diabetic patients with insulin allergy previously documented by positive skin tests have been investigated with insulin of bovine, porcine and human origin and with a synthetic human insulin (CGP 12 831). In 3 patients clearly positive skin tests were found even against CGP 12 831. In lymphocyte transformation tests performed in these 3 cases, an increase of 3H-thymidine uptake was found when Actrapid was added. No increase was observed when CGP 12 831 was added.

Animals↗

Microalbuminuria in diabetes mellitus: efficacy of a new screening method in comparison with timed overnight urine collection.

Diabetic nephropathy and end-stage renal failure are still a major cause of mortality amongst patients with diabetes mellitus (DM). In this study, we evaluated the Clinitek-Microalbumin (CM) screening test strip for the detection of microalbuminuria (MA) in a random morning spot urine in comparison with the quantitative assessment of albuminuria in the timed overnight urine collection ("gold standard"). One hundred thirty-four children, adolescents, and young adults with insulin-dependent DM Type 1 were studied at 222 outpatient visits. Because of urinary tract infection and/or haematuria, the data of 13 visits were excluded. Finally, 165 timed overnight urine were collected in the remaining 209 visits (79% sample per visit rate). Ten (6.1%) patients presented MA of > or =15 microg/min. In comparison however, 200 spot urine could be screened (96% sample/visit rate) yielding a significant increase in compliance and screening rate (P<.001, McNemar test). Furthermore, at 156 occasions, the gold standard and CM could be directly compared. The sensitivity and the specificity for CM in the spot urine (cut-off > or =30 mg albumin/l) were 0.89 [95% confidence interval (CI) 0.56-0.99] and 0.73 (CI 0.66-0.80), respectively. The positive and negative predictive value were 0.17 (CI 0.08-0.30) and 0.99 (CI 0.95-1.00), respectively. Considering CM albumin-to-creatinine ratio, the results were poorer than with the albumin concentration alone. Using CM instead of quantitative assessment of albuminuria is not cost-effective (35 US dollars versus 60 US dollars/patient/year). In conclusion, to exclude MA, the CM used in the random spot urine is reliable and easy to handle, but positive screening results of > or =30 mg albumin/l must be confirmed by analyses in the timed overnight collected urine. Although the screening compliance is improved, in terms of analysing random morning spot urine for MA, we cannot recommend CM in a paediatric diabetic outpatient setting because the specificity is far too low.

Adolescent↗