Search PubMed⌕ Search

Biomedical subjects

P Colautti

Publications and source records attributed to P Colautti.

14 recordsLinked to original sources

A solid state microdosimeter based on a monolithic silicon telescope.

A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses the preliminary results of an analytical approach for the correction of a spectrum measured with this silicon-based microdosimeter for tissue-equivalence and geometrical effects. The device was irradiated with 2.7 MeV monoenergetic neutrons at the INFN-Laboratori Nazionali di Legnaro (Legnaro, Italy). The non tissue-equivalence of silicon was corrected by exploiting the signals generated in the E-stage. The correction for the sensitive volume geometry was optimised by taking into account the track length distribution of the recoil-protons generated in the converter. The derived dose distribution of the energy imparted per event was compared to the one measured with a cylindrical tissue-equivalent proportional counter (TEPC). The agreement is satisfactory.

Computer-Aided Design↗

Simulation of the measured ionisation-cluster distributions of alpha-particles in nanometric volumes of propane.

In the last years, the probability of the formation of ionisation clusters by primary alpha particles at 5.4 MeV in nanometric volumes of propane (20.6 and 24.0 nm in a material of density 1.0 g cm(-3)) was studied experimentally and by Monte Carlo simulation. Calculations were performed taking into account the single electron detection efficiency of the track-nanodosimetric counter, which was estimated on the base of Monte Carlo calculations of electron transport inside the detector. Now a new evaluation of the efficiency has been performed, pointing out a value lower than previously estimated. Besides, the efficiency of the counter in resolving temporally the collected electrons has been calculated, together with its effect on the measured distribution. On the base of these evaluations, a new comparison has been performed between measurements and calculations, pointing out a better agreement than previously reported.

Alpha Particles↗

Mini-TEPCs for radiation therapy.

A mini-tissue-equivalent proportional-counter (TEPC) has been constructed to study the possibility to manufacture mini-counters without field-shaping tubes for radiation therapy. The mini-TEPC can be assembled with and without field-shaping tubes. It can be equipped with a mini-alpha source for a precise lineal energy calibration. After the positive conclusions of this study, a slim TEPC has been designed and constructed. The slim TEPC has an external diameter of only 2.7 mm. It has been tested with therapeutic proton beams and gamma ray sources.

Equipment Design↗

Microdosimetric investigation at the therapeutic proton beam facility of CATANA.

Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation quality of two spread-out Bragg peaks (SOBP) at the CATANA proton beam.

Algorithms↗

Design of a 10 nm electron collector for a track-nanodosimetric counter.

Recently we have developed a track-nanodosimetric counter, which is a gas detector that measures the distributions of electrons induced by a charged particle in nanometric volumes of tissue equivalent matter, positioned at different distances from the track. Sites equivalent to 20 and 24 nm were defined by means of an electron collector, which is a system of electrodes enclosing an almost wall-less cylindrical volume. In this paper, we present the design of a new electron collector that is able to simulate a volume as small as 10 nm in diameter.

Algorithms↗

Experimental equivalent cluster-size distributions in nanometric volumes of liquid water.

Ionisation cluster-size distributions in nanometric volumes of liquid water were determined for alpha particles at 4.6 and 5.4 MeV by measuring cluster-size frequencies in small gaseous volumes of nitrogen or propane at low gas pressure as well as by applying a suitable scaling procedure. This scaling procedure was based on the mean free ionisation lengths of alpha particles in water and in the gases measured. For validation, the measurements of cluster sizes in gaseous volumes and the cluster-size formation in volumes of liquid water of equivalent size were simulated by Monte Carlo methods. The experimental water-equivalent cluster-size distributions in nitrogen and propane are compared with those in liquid water and show that cluster-size formation by alpha particles in nitrogen or propane can directly be related to those in liquid water.

Algorithms↗

BNCT microdosimetry at the tapiro reactor thermal column.

A thermal column is available for dosimetric and radiobiological studies by the fast reactor TAPIRO, located at the ENEA research centre Casaccia. The TAPIRO neutron field has been studied (in the frame of LNL BNCT project) with a tissue-equivalent proportional counter, which has worked alternatively with an ordinary tissue-equivalent cathode and with a boron-enriched cathode. Measurements have been performed with polyethylene caps of different thickness. Both the absorbed dose and the microdosimetric-calculated biological effective dose show a maximum at approximately 0.5 mg cm(-2) of depth. The different dose components have been calculated and the results are discussed.

Body Burden↗

Ionization-cluster distributions of alpha-particles in nanometric volumes of propane: measurement and calculation.

The probability of the formation of ionization clusters by primary alpha-particles at 5.4 MeV in nanometric volumes of propane was studied experimentally and by Monte Carlo simulation, as a function of the distance between the center line of the particle beam and the center of the target volume. The volumes were of cylindrical shape, 3.7 mm in diameter and height. As the investigations were performed at gas pressures of 300 Pa and 350 Pa, the dimensions of the target volume were equivalent to 20.6 nm or 24.0 nm in a material of density 1.0 g/cm(3). The dependence of ionization-cluster formation on distance was studied up to values equivalent to about 70 nm. To validate the measurements, a Monte Carlo model was developed which allows the experimental arrangement and the interactions of alpha-particles and secondary electrons in the counter gas to be properly simulated. This model is supplemented by a mathematical formulation of cluster size formation in nanometric targets. The main results of our study are (i) that the mean ionization-cluster size in the delta-electron cloud of an alpha-particle track segment, decreases as a function of the distance between the center line of the alpha-particle beam and the center of the sensitive target volume to the power of 2.6, and (ii) that the mean cluster size in critical volumes and the relative variance of mean cluster size due to delta-electrons are invariant at distances greater than about 20 nm. We could imagine that the ionization-cluster formation in nanometric volumes might in future provide the physical basis for a redefinition of radiation quality.

Biophysics↗

Nanodosimetric measurements with an avalanche confinement TEPC.

This paper illustrates a tissue-equivalent proportional counter designed to have high gas gain and good energy resolution at nanometric simulated site sizes. Microdosimetric neutron and gamma spectra were measured in dimethyl ether and in propane-based tissue-equivalent gas mixture down to 35 nm. The comparison of experimental data with the results of Monte Carlo calculations shows a satisfactory agreement.

Dose-Response Relationship, Radiation↗

A feasibility study of a single event spectrometer based on semiconductor devices.

The electronics employed around particle accelerators can be disturbed or damaged because of single event effects (SEE). The most likely effect is the single event upset (SEU) which may affect all memory devices. In the case of high energy accelerators, SEUs are mostly produced by secondary charged particles generated by neutron interactions. The measurement of the energy and the lineal energy distribution of these neutron-induced charged particles was proposed. As a first approach, a commercial p-i-n photodiode was employed. This device was irradiated with thermal and monoenergetic fast neutrons. Some effects limiting the use of such a detector as a SEE spectrometer were observed, giving guidelines for the design of an application specific integrated circuit (ASIC). The possibility of creating a solid state microdosemeter by coupling the ASIC with a tissue-equivalent radiator is discussed. Moreover, the p-i-n photodiode covered with a hydrogenated plastic radiator may be employed as a proton-recoil spectrometer.

Dose-Response Relationship, Radiation↗

Track nanodosimetry of an alpha particle.

Experimental measurements and calculations are described of ionisation distributions in propane wall-less gas cavities of about 20 nm simulated size, performed at different distances from a 244Cm alpha particle track. Ionisation events are detected one by one by collecting electrons from the sensitive volume and by separating them with a drift column. Experimental results and Monte Carlo calculations indicate that, in the delta ray cloud, conditional probability curves, average cluster size and the ratio of second moment above first moment of the cluster distribution are invariant with track distance.

Alpha Particles↗

Neonatal erythrocyte glutathione peroxidase deficiency as a consequence of selenium imbalance during pregnancy.

The red blood cell (RBC) glutathione peroxidase (GSH-Px) activity and routine haematological parameters were measured in 38 healthy north Italian full-term pregnant women and in their newborn infants. In 31 pairs the serum selenium concentration was also measured. Data were compared with those of 20 normal adult controls (10 males and 10 females). Newborn infants exhibited significantly lower RBC GSH-Px activity and serum selenium concentrations than adult controls. Pregnant women had serum selenium values intermediate between those of adult female controls and their newborn infants. In both the pregnant women and newborns the RBC GSH-Px activity correlated with the level of selenium in serum which suggests that the neonatal RBC GSH-Px deficiency may be partially due to insufficient availability of selenium during pregancy. Factors other than selenium concentration, e.g. hormonal and genetic, might also affect the RBC GSH-Px activity as suggested by sex differences and mother/child concordances in enzyme activity found in our cases.

Adolescent↗

Trace elements in biological systems: nuclear techniques app.

Nuclear techniques are very useful in the simultaneous determination of many trace elements in biological samples; the sensitivity depends on the method and on the elements in study and in many cases is better than 0;1 ppm. Proton-induced X-ray fluorescence and alpha-particle elastic diffusion techniques are described; the methods of sample preparation, the sensitivity obtained and some experimental results are included.

Alpha Particles↗