Search PubMed⌕ Search

Biomedical subjects

P Cao

Publications and source records attributed to P Cao.

At least 37 records · Page 2Linked to original sources

[Relationship between the expression of bcl-2 apoptosis and acute myelogenous leukemia prognosis].

In order to check the anti-apoptosis gene bcl-2 protein expression in 58 AML patients we used the immunohistochemical method, and analyse the relationship between bcl-2 protein and prognosis of AML. The result showed that the high expression of bcl-2 protein was related to poor clinical prognosis of AML. This shows that the expression of bcl-2 gene can serve as an index for the prognosis of AML.

Adolescent↗

Mapping the phosphorylation sites of proteins using on-line immobilized metal affinity chromatography/capillary electrophoresis/electrospray ionization multiple stage tandem mass spectrometry.

On-line immobilized metal affinity chromatography/capillary electrophoresis/electrospray ionization-mass spectrometry (IMAC/CE/ESI-MS) offers selective preconcentration of phosphorylated peptides with identification of the phosphorylated amino acid(s). The preconcentration provides low concentration limits of detection and capillary electrophoresis separates the peptides. Recently, we reported a fast, simple, and sensitive on-line IMAC/CE/ESI-MS/MS method for the determination of phosphopeptides at low-pmole levels. That work is expanded here by use of multiple stage tandem mass spectrometry (MS(n), n = 2,3) to isolate and fragment target ions to provide more reliable assignments of phosphorylated residues. The application of IMAC/CE/ESI-MS(n) is demonstrated by the analysis of tryptic digests of alpha- and beta-casein and in-gel tryptic digests of beta-casein.

Amino Acid Sequence↗

Predictive factors for early success of endovascular abdominal aortic aneurysm repair.

To identify predictive factors for postoperative success and potential predictors for satisfactory outcome of endovascular grafting for abdominal aortic aneurysm (AAA), we collected data from our prospective database, which includes a series of consecutive patients undergoing endovascular repair at the Vascular Surgery Unit, Policlinico Monteluce, Perugia, Italy. From April 1997 to July 1998, 202 patients were referred to our Unit for elective AAA repair; 94 patients (47%) were selected for endografting. Placement of the graft using endovascular technique without conversion to open laparotomy, in addition to no mortality, major morbidity, or endoleak at 30-day follow-up, was defined as postoperative success. The influence of anatomical features on postoperative results was analyzed by univariate and multivariate analysis. Our experience shows that endoluminal repair of AAA is safe and effective in the short term and male patients with small aneurysms are optimal candidates for successful repair.

Aged↗

Eversion versus conventional carotid endarterectomy: late results of a prospective multicenter randomized trial.

OBJECTIVE: The durability of carotid endarterectomy (CEA) may be affected by carotid restenosis. The data from randomized trials show that the highest incidence of restenosis after CEA occurs from 12 to 18 months after surgery. The optimal CEA technique to reduce perioperative complications and restenosis rates is still undefined. This study examines the long-term clinical outcome and incidence of recurrent stenosis in patients who undergo eversion CEA. Previously published perioperative results of this study did not show statistically significant differences in study endpoints between the eversion and standard techniques. METHODS: From October 1994 to March 1997, 1353 patients with surgical indications for carotid stenosis were randomly assigned to undergo eversion (n = 678) or standard CEA (n = 675; primary closure, 419; patch, 256). Withdrawal from the assigned treatment occurred in 1.6% of the patients (in 13 assigned to eversion CEA, and in nine assigned to standard CEA). The clinical and duplex scan follow-up examination was 99% complete, and the mean follow-up interval was 33 months (range, 12 to 55 months). The primary outcomes were perioperative and late major stroke and death, carotid restenosis (stenosis >/= 50% of the lumen diameter detected at duplex scanning), and carotid occlusion. The primary evaluation of study outcomes was conducted on the basis of an intention-to-treat analysis. RESULTS: Restenosis was found at duplex scanning in 56 patients (19 in the eversion group, and 37 in the standard group). Within the standard group, the restenosis rates were 7.9% in the primary closure population and 1.5% in the patched population. Of the patients with restenosis, 36% underwent cerebral angiography that confirmed restenosis in all cases. The cumulative restenosis risk at 4 years was significantly lower in the group that underwent treatment with eversion CEA as compared with the standard group (3.6% vs 9.2%; P =.01), with an absolute risk reduction of 5. 6% and a relative risk reduction of 62%. Eighteen patients would have had to undergo treatment with eversion CEA to prevent one restenosis during the 4-year period. The incidence rate of ipsilateral stroke was 3.3% in the eversion population and 2.2% in the standard group. There were no significant differences in the cumulative risks of ipsilateral stroke (3.9% for eversion, and 2.2% for standard; P =.2) and death (13.1% for eversion, and 12.7% for standard; P =.7)) in the two groups. Of the 18 variables that were examined for their influence on restenosis, eversion CEA (hazard ratio, 0.3; 95% confidence interval, 0.2 to 0.6; P =.0004) and patch CEA (hazard ratio, 0.2; 95% confidence interval, 0.07 to 0.6; P =. 002) were negative independent predictors of restenosis with multivariate Cox proportional hazards regression analysis. CONCLUSION: The EVEREST (EVERsion carotid Endarterectomy versus Standard Trial) showed that eversion CEA is safe, effective, and durable. No statistically significant differences were found in late outcome between the eversion and standard techniques at the available follow-up examination.

Actuarial Analysis↗

Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair.

OBJECTIVE: to validate the role of duplex scan in endoleak detection in postoperative surveillance of endoluminal abdominal aneurysm repair (EAAR). PATIENTS AND METHODS: between April 1997 and March 1999, 103 patients were eligible for duplex and computed tomography (CT) scan after EAAR. Mean follow-up was 8 months (range 1-24 months). The study protocol comprised concurrent examination with colour-duplex and CT scan at 1, 6, and 12 months after EAAR, for a total of 198 concurrent examinations. All duplex scan examinations were performed by two vascular surgeons with the same machine (ATL HDI 3000). Interobserver agreement in endoleak detection (kappa=1) and in type of endoleak (kappa=0.7) was evaluated in 50 random duplex examinations. Endoleak detection was examined comparatively in duplex and CT scan, the latter being the gold standard. Sensitivity and specificity tests together with negative- and positive-predictive values (NPV and PPV) were calculated. RESULTS: duplex scan was not feasible in one patient. On CT scan the endoleak rate was 4% at one month, 3% at 6 months, and 4% at one year. Overall, CT scan detected 12 endoleaks. With respect to endoleak detection, duplex scan revealed a great ability in ruling out false-negative results (sensitivity 91.7%, NPV 99.4%), but overestimated the presence of endoleak (specificity 98.4%, PPV 78. 6%). Regarding type of endoleak, the ability of duplex scan to identify the source of endoleak was low (sensitivity 66.7%). CONCLUSIONS: duplex scan, if validated, appears to be a reliable means for excluding the presence of endoleak after EAAR.

Aged↗

[Analysis of impulse response of rectangular ultrasound transducer].

A new expression for calculating the impulse response of rectangular pistonlike transducers, proper to any points of acoustic field, is presented. The radiated field of ultrasound transducer can be analyzed using impulse response method, avoiding paraxial and farfield approximation. The velocity potential at an observation point is expressed as the convolution of the excitation velocity and the impulse response. A time-amplitude shift method for the far field impulse response of small aperture transducers is presented. The radiated field of rectangular transducers is calculated through the new method and the previous method and excellent agreement is observed.

Algorithms↗

[Two-dimensional surface Raman imaging of a roughened iron electrode in saline solution].

By using a confocal microprobe Raman system and proper surface roughening procedure for iron, the pit corrosion behavior of bare iron electrode in 3.4% NaCl (saline solution) solution has been investigated. The surface-enhanced Raman scattering (SERS) spectra of the corrosion products due to the pit corrosion at positive potential was obtained with high ratio of signal to noise. The application of SERS technique has been extended successfully to the study of iron corrosion. The two-dimensional surface Raman imaging acquired at 660 cm-1 was obtained also with the utility of surface Raman image technique. Results show that different iron oxides should coexist in the pit corrosion region and the distribution of the corrosion products was not uniform.

Chemical Phenomena↗

A dominant negative mutant of Helicobacter pylori vacuolating toxin (VacA) inhibits VacA-induced cell vacuolation.

Most Helicobacter pylori strains secrete a toxin (VacA) that causes structural and functional alterations in epithelial cells and is thought to play an important role in the pathogenesis of H. pylori-associated gastroduodenal diseases. The amino acid sequence, ultrastructural morphology, and cellular effects of VacA are unrelated to those of any other known bacterial protein toxin, and the VacA mechanism of action remains poorly understood. To analyze the functional role of a unique strongly hydrophobic region near the VacA amino terminus, we constructed an H. pylori strain that produced a mutant VacA protein (VacA-(Delta6-27)) in which this hydrophobic segment was deleted. VacA-(Delta6-27) was secreted by H. pylori, oligomerized properly, and formed two-dimensional lipid-bound crystals with structural features that were indistinguishable from those of wild-type VacA. However, VacA-(Delta6-27) formed ion-conductive channels in planar lipid bilayers significantly more slowly than did wild-type VacA, and the mutant channels were less anion-selective. Mixtures of wild-type VacA and VacA-(Delta6-27) formed membrane channels with properties intermediate between those formed by either isolated species. VacA-(Delta6-27) did not exhibit any detectable defects in binding or uptake by HeLa cells, but this mutant toxin failed to induce cell vacuolation. Moreover, when an equimolar mixture of purified VacA-(Delta6-27) and purified wild-type VacA were added simultaneously to HeLa cells, the mutant toxin exhibited a dominant negative effect, completely inhibiting the vacuolating activity of wild-type VacA. A dominant negative effect also was observed when HeLa cells were co-transfected with plasmids encoding wild-type and mutant toxins. We propose a model in which the dominant negative effects of VacA-(Delta6-27) result from protein-protein interactions between the mutant and wild-type VacA proteins, thereby resulting in the formation of mixed oligomers with defective functional activity.

Amino Acid Sequence↗

Phosphopeptide analysis by on-line immobilized metal-ion affinity chromatography-capillary electrophoresis-electrospray ionization mass spectrometry.

The analysis of large phosphoproteins by mass spectrometry is a particular challenge, in many cases, because of the small proportion of phosphopeptides in the presence of a large number of non-phosphorylated peptides. In addition, phosphopeptides are generally available in dilute solutions. Thus, methods to specifically identify phosphopeptides at low concentrations are important. In this work, on-line Fe(III) immobilized metal-ion affinity chromatography (IMAC)-CE-electrospray ionization MS was developed and applied to sub-pmol analysis of phosphopeptides. Phosphopeptides bind Fe(III) with high selectivity. The IMAC resin is packed directly at the head of the CE column. After the phosphopeptides are bonded to the resin and washed, they are eluted at high pH and separated by CE. This method has several advantages: (1) selective retention and pre-concentration of phosphopeptides on an Fe(III)-IMAC resin; (2) a pre-wash of the sample to remove salts and buffers that are not suited for CE separation or ESI operation; (3) facile fabrication with common tools and chemicals (less than 10 min); (4) adaptation to commercial CE instruments without any modifications. The applications of IMAC-CE-MS are demonstrated by the analysis of phosphopeptide mixtures and a phosphoprotein digest.

Amino Acid Sequence↗

Hydroquinone as a buffer additive for suppression of bubbles formed by electrochemical oxidation of the CE buffer at the outlet electrode in capillary electrophoresis/electrospray ionization-mass spectrometry.

Hydroquinone was found to suppress bubble formation at the outlet electrode of a sheathless capillary electrophoresis/electrospray ionization-mass spectrometer by replacing the oxidation of water (2H2O(1)<-->O2(g) + 4H+ + 4e) with that of more easily oxidized hydroquinone (hydroquinone<-->p-benzoquinone + 2H+ + 2e). Formation of p-benzoquinone replaces the formation of oxygen gas, effectively suppressing gas bubble formation. Several electrode materials, including platinum, gold-coated stainless steel, and stainless steel wires, were tested. However, hydroquinone suppressed bubbles only at the platinum electrode. Combination of the in-capillary electrode sheathless interface using platinum wire, hydroquinone as a buffer additive, and pressure programming at the inlet of the capillary electrophoresis provided a rugged high efficiency interface for analysis of protein digests using CE/ESI-MS.

Buffers↗

Prospective, randomized, double-blind trial comparing teicoplanin and cefazolin as antibiotic prophylaxis in prosthetic vascular surgery.

To compare efficacy, tolerability, and cost of antibiotic prophylaxis with teicoplanin and cefazolin in clean prosthetic vascular surgery, a randomized, prospective, double-blind study was performed at the Vascular Surgery Unit of a tertiary-care university hospital. Two-hundred thirty-eight consecutive patients undergoing elective, clean, abdominal or lower-limb prosthetic vascular surgery were allocated to receive a single intravenous dose of teicoplanin (400 mg) or cefazolin (2 g) at the induction of anesthesia. Surgical-site infections occurred in 5.9% of teicoplanin recipients (4.2% wound infection, 1.7% graft infection) and 1.7% of cefazolin recipients (1.7% wound infection, 0% graft infection) (P=0.195). Other postoperative infections occurred in 10% of teicoplanin recipients (pneumonia 7%, urinary tract infection 3%) and 12% of cefazolin recipients (pneumonia 7%, urinary tract infection 2.5%, bloodstream infections 2.5%). Overall mortality rate was 3.4% in teicoplanin recipients (4 patients) and 2.5% in cefazolin recipients (3 patients). Infective deaths occurred in one patient for each group. The two prophylactic regimens were well tolerated. Cost savings of US $52,510 favoring cefazolin were related to the lower acquisition cost (US $1034 vs US $4740) and to the shorter duration of the hospital stay (1762 days vs 1928 days). Cefazolin can still be regarded as the drug of choice for prophylaxis in clean vascular surgery.

Aged↗

Epidural anesthesia reduces length of hospitalization after endoluminal abdominal aortic aneurysm repair.

PURPOSE: The low invasiveness of endoluminal abdominal aneurysm repair (EAAR) appears optimal for the use of epidural anesthesia (EA). However, reported series on EAAR show that general anesthesia (GA) is generally preferred. To evaluate the feasibility and problems encountered with EA for EAAR, patients undergoing EAAR with EA and patients undergoing EAAR with GA were examined. METHODS: From April 1997 through October 1998, EAAR was performed on 119 patients at the Unit of Vascular Surgery at Policlinico Monteluce in Perugia, Italy. Four patients (3%) required conversion to open repair and were excluded from the analysis because they were not suitable candidates for evaluating the feasibility of EA. The study cohort thus comprised 115 patients undergoing abdominal aortic aneurysm (AAA) repair with the AneuRx Medtronic stent graft. The incidence of risk factors and anatomical features of the aneurysm were compared in patients selected for EA or GA on the basis of intention-to-treat analysis. Intraoperative and perioperative data were compared and analyzed on the basis of intention-to-treat and on-treatment analysis. RESULTS: Sixty-one patients (54%) underwent the surgical procedure with EA (group A), and 54 (46%) underwent the surgical procedure with GA (group B). Conversion from EA to GA was required in four patients (3 of 61 patients, 5%). There were no statistically significant differences between the two study groups in demographics, clinical characteristics, and American Society of Anesthesiology classification (ASA). There was no perioperative mortality. Major morbidity occurred in 3% of patients (group B). According to intention-to-treat analysis, no significant differences were observed between the two groups in mean operating time, fluoro time, blood loss, amount of contrast media used, mean units of transfused blood, need of intensive care unit, mean postoperative hospital stay, and postoperative endoleak. Conversely, significant differences were found by means of on-treatment analysis in the need of intensive care unit (0 vs 5 patients; P =.02), and length of hospitalization (2.5 vs 3.2 days; P =.04). Multivariate logistic regression analysis showed that GA and ASA 4 were positive independent predictors of prolonged (more than 2 days) postoperative hospitalization (hazard ratio, 2.5; 95% CI, 1.1 to 5.8; P =.03, and hazard ratio, 5.1; 95% CI, 1.5 to 17.9; P =.007, respectively). CONCLUSION: EA for EAAR is feasible in a high percentage of patients in whom it is attempted, and it ensures a technical outcome comparable with that of patients undergoing EAAR with GA. Successful completion of EAAR with EA is associated with a short period of hospitalization.

Aged↗

Cerebral tomographic findings in patients undergoing carotid endarterectomy for asymptomatic carotid stenosis: short-term and long-term implications.

PURPOSE: Preoperative cerebral imaging has been considered not to be cost-effective in carotid endarterectomy (CEA) for asymptomatic carotid stenosis. Yet, silent brain infarction (SBI) has been associated with the embolization potential of a severe carotid stenosis. Thus the presence of SBI may represent an additional indication for CEA in asymptomatic patients. We examined the predictive value of preoperatively detected silent cerebral lesions on early and late outcomes in patients undergoing CEA for asymptomatic carotid stenosis. METHODS: Preoperative cerebral tomographic (CT) scans performed on 301 asymptomatic patients undergoing 346 CEAs from 1986 to 1995 were reviewed by a single neuroradiologist blinded to patients' records. Mean follow-up was 67. 3 months (range, 24-130 months). The degree of internal carotid lumen reduction was measured bilaterally in all patients (602 carotid arteries); carotid stenosis of 60% or more was found in 399 carotid arteries. RESULTS: Of the 103 (34%) CT scans positive for cerebral lesions, 58% were lacunar. No significant association was observed between the side of the cerebral lesion on CT scan and the severity of the corresponding carotid stenosis; 38 silent lesions were detected in the 203 hemispheres ipsilateral to carotid stenoses that were less than 60% versus 95 SBIs in the 399 hemispheres ipsilateral to carotid stenoses that were 60% or more (19% vs 24%; P =.2). There were no significant differences in the perioperative stroke/death rate in patients with or without cerebral CT lesions (2% vs 1%; odds ratio, 1.94; P =.6). Mortality rate during follow-up was 22% in patients with preoperative SBI and 15% in patients without SBI (P =.1). However, actuarial survival at 10 years was shorter (P =.02) in patients with SBI. Late stroke occurred in 11% of patients with preoperative SBI and in 3% of patients without preoperative SBI (P =.006). Cox regression analysis showed that both preoperative lacunar and nonlacunar infarctions were independent predictors of late stroke (hazard ratio, 3.6; P =.04; and hazard ratio, 7.1; P =.001; respectively). CONCLUSION: In our experience, preoperative SBI did not occur more frequently in the hemisphere ipsilateral to asymptomatic severe carotid stenosis. Although our study lacks a medically treated control group, our data show that SBI is predictive of poor neurologic outcome in asymptomatic patients undergoing CEA. We conclude that CT before CEA, selectively applied, provides information on long-term neurologic prognosis and that a less aggressive attitude towards CEA in asymptomatic patients with SBI may be justified.

Adult↗

Endoluminal repair of infrarenal abdominal aortic aneurysms using a modular stent-graft: one-year clinical results from a European multicentre trial.

This is a report of a prospective study to evaluate the safety and efficacy of the Medtronic AneuRx stent-graft. Patients with an infrarenal aneurysm with a proximal neck length of greater than 10 mm and a neck diameter not greater than 26 mm and iliac artery diameters of at least 6 mm were accepted for endovascular repair using the Medtronic AneuRx modular stent-graft. A total of 104 patients were included in the study. Transfemoral placement of the bifurcated stent-graft was successful in 102 of 104 patients. Two conversions were performed. The mean operating time was 148 min (range 75-480) and the mean blood loss was 605 ml (range 100-2900). The mean follow-up was 15 months (range 12-21). Complications were rare and no kinking or migration occurred. At follow-up, four endoleaks persisted after 12 months. The Medtronic AneuRx stent-graft is a safe and efficacious alternative to open abdominal aortic aneurysm repair with excellent early results.

Aged↗

Separation and detection of the alpha- and beta-chains of hemoglobin of a single intact red blood cells using capillary electrophoresis/electrospray ionization time-of-flight mass spectrometry.

A single intact red blood cell (erythrocyte) was injected into a capillary electrophoresis column, and following in-capillary lysing the alpha- and beta-chains of the hemoglobin (approximately 450 amol) were separated and detected using capillary electrophoresis/electrospray ionization time-of-flight mass spectrometry. The mass specta of the electropherogram peaks of the alpha and beta chains showed identifiable peaks corresponding to multiply protonated and sodiated alpha- and beta-chains of hemoglobin.

Electrophoresis, Capillary↗

Intraoperative assessment of technical perfection in carotid endarterectomy: a prospective analysis of 1305 completion procedures. Collaborators of the EVEREST study group. Eversion versus standard carotid endartectomy.

OBJECTIVE: to define the incidence of technical defects and the impact of technical errors on ipsilateral carotid occlusion, ipsilateral stroke, and early restenosis rates, we analysed 1305 patients undergoing carotid completion procedures. DESIGN: prospective multicentre study. PATIENTS AND METHODS: adequacy of CEA was assessed intraoperatively by angiography in 1004 (77%), by angioscopy in 299 (22%), and by duplex scan in two patients (1%). Arteriograms and angioscopic findings were interpreted at the time of the procedure by the operating surgeon, who also established the need for immediate surgical revision. RESULTS: perioperatively, 13 major strokes (0.9%, all ipsilateral) and six deaths (0.4%) were recorded. Overall, 112 defects (9%) were identified intraoperatively: 81 (72%) were located in the common carotid artery (CCA) or internal carotid artery (ICA), and 31 (28%) in the external carotid artery. In 48 patients (4%) the defects were revised. Logistic regression analysis revealed that carotid plaque extension >2 cm on the ICA was a positive independent predictor of CEA defects (odds ratio (OR) 1.5p=0.03). A significant association was found between the incidence of revised defects of the CCA and ICA and perioperative ipsilateral stroke (OR 11.5p=0.0002). In contrast, patients with minor non-revised defects had an ipsilateral stroke rate comparable to that of patients with no defects (p=0.4). No significant association was found between revised or non-revised defects and occurrence of restenosis/occlusion at 6-month follow-up. CONCLUSIONS: the incidence of major technical defects during CEA is low, yet the perioperative neurological prognosis of patients with major defects warranting revision is poor. Completion angiography or angioscopy and possible correction of defects did not protect per se from an unfavourable early outcome after CEA. Therefore, surgical excellence is mandatory to achieve satisfactory results after CEA.

Adult↗