Search PubMedSearch

Biomedical subjects

P Burkhalter

Publications and source records attributed to P Burkhalter.

6 recordsLinked to original sources

Reverse transcription PCR to detect enteroviruses in surface water.

We have developed a simple, fast, and efficient procedure to detect enteroviruses in water samples. Aliquots of water are subjected to two-step filtration, with the second filter containing a positively charged nylon membrane that holds back virus particles. Viruses thus adsorbed are directly lysed, and RNA is isolated by hybridization to specific oligonucleotides bound to magnetic beads. The solution used contains guanidine thiocyanate, which lyses virus particles, inactivates enzymes, e.g., RNases, allows mild hybridization conditions, and does not influence biotin-streptavidin interaction on magnetic beads. Detection and specific identification are accomplished by reverse transcription PCR of the highly conserved noncoding region at the 5' end of virus RNA combined with Southern hybridization. The system was tested with tap water artificially spiked with poliovirus vaccine and yielded a detection limit of 20 50% tissue culture infective doses per liter. We used the same procedure to investigate the water quality of surface water at public beaches by rivers and lakes. Of 40 samples tested, 7 were positive for enteroviruses. A comparison with enterobacterial contamination determined by PCR and classical microbiological methods in parallel showed that enteroviruses were found only in samples also positive for Escherichia coli. In conclusion, this procedure can easily be adapted to test large water samples and is simple enough to be used for routine determinations of water quality in terms of virus contamination.

Base Sequence

Random amplification of polymorphic bacterial DNA: evaluation of 11 oligonucleotides and application to food contaminated with Listeria monocytogenes.

The polymerase chain reaction was used to obtain randomly-amplified polymorphic DNA (RAPD) profiles from Listeria spp. and enterobacteria. Eleven different oligonucleotides were evaluated. Only one, HR4 (19mer), generated reproducible and specific profiles for Listeria spp., while results for enterobacteria were controversial. A total of 57 different Listeria strains were subjected to the RAPD analysis and 27 different profiles were recognized. RAPD typing allowed strains of the same serotype to be distinguished but the same profile was obtained from different serotypes of L. monocytogenes in three cases and in one case two different serotypes of L. innocua yielded the same profile. RAPD-typing with HR4 allowed L. monocytogenes contamination in several food outlets to be traced back to a food processing plant. In additional experiments, the general utility of this RAPD system in typing Yersinia enterocolitica, verotoxigenic Escherichia coli and Salmonella enteritidis was evaluated.

Bacterial Typing Techniques