The performance of Mini Wright peak flow meters after prolonged use.

The accuracy of 84 new and 35 old Mini Wright peak flow meters were tested using a servo-controlled pump system. The 95% confidence limits for flow measurement across the range of the new meters was between +/- 151 min-1 at the lower end of the range and +/- 28 l min-1 at the top of the range. The readings for 22 (63%) of the old meters (age range 1-13 yr) were within these 95% confidence limits. For the remaining 13 old meters (age range 1-13 yr) whose readings were not within these limits, there were 11 meters with readings falling below and two meters with readings above these limits. Twelve of these old meters were washed and retested and there was no significant change in their readings. Twenty of the new meters were retested after 1 yr of continuous use and their readings were significantly higher with a median value of 5 l min-1 across the range, although only two of these 20 meters had readings outside the 95% confidence limits set from the 84 new meters. It is concluded that whilst Mini Wright meters aged up to 14 yr can give readings which are as good as new meters, some meters demonstrate significant changes in readings after only 1 yr and washing did not correct this change. It is recommended that clinicians prescribing peak expiratory flow (PEF) meters should be responsible for checking the patient's meter as well as their PEF readings at clinic visits.

Disinfection↗

Occupational asthma due to glutaraldehyde and formaldehyde in endoscopy and x ray departments.

BACKGROUND: Glutaraldehyde is the best disinfectant for fibreoptic endoscopes. It is also used in the processing of x ray films. A number of studies have reported eye, nose, and respiratory symptoms in exposed workers. Three individual case reports of occupational asthma in endoscopy workers and a radiographer have also been published. We describe a further seven cases of occupational asthma due to glutaraldehyde in endoscopy and x ray departments, together with exposure levels measured during the challenge tests and in 19 endoscopy and x ray departments in the region. METHODS: Eight workers were referred for investigation of suspected occupational asthma following direct or indirect exposure to glutaraldehyde at work. They were investigated by serial measurements of peak expiratory flow (PEF) and specific bronchial provocation tests. Glutaraldehyde levels were measured using personal and static short and longer term air samples during the challenge tests and in 13 endoscopy units and six x ray darkrooms in the region where concern about glutaraldehyde exposure had been expressed. Three of the workers investigated with occupational asthma came from departments where glutaraldehyde air measurements had been made; the others came from other hospitals or departments. RESULTS: The diagnosis of occupational asthma was confirmed in seven workers, all of whom had PEF records suggestive of occupational asthma and positive specific bronchial challenge tests to glutaraldehyde. Bronchial provocation testing was negative in one worker who was no longer exposed and who had a less clearcut history of occupational asthma. Three workers also had a positive specific bronchial challenge to formaldehyde. The mean level of glutaraldehyde in air during the challenge tests was 0.068 mg/m3, about one tenth of the short term occupational exposure standard of 0.7 mg/m3. The levels obtained in the challenge chamber were similar to those measured in 13 endoscopy suites and six x ray darkrooms where median short term levels were 0.16 mg/m3 during decantation in endoscopy suites and < 0.009 mg/m3 in darkrooms. CONCLUSIONS: Glutaraldehyde can cause occupational asthma. The exposure levels measured in the workplace suggest that sensitisation may occur at levels below the current occupational exposure standard.

Adult↗

Differences in output from corticosteroid inhalers used with a volumatic spacer.

Corticosteroid inhaler therapy using a spacer device is commonly used as an important part of asthma management. Increasingly, generic corticosteroid inhalers are being used with spacer devices. We have therefore tested whether these generic inhalers yield equivalence in dose when compared to the established inhalers. We measured the in vitro output, discharged into a Volumatic spacer from beclomethasone dipropionate inhalers (250 micrograms.puff-1) made by three manufacturers, Allen & Hanburys, 3M and Baker Norton. The output from 20 of each type of inhaler was sampled, in random order, by a computer driven pump system. Beclomethasone was absorbed onto a coded filter, which was analysed independently for drug content. The output per puff differed significantly between the inhalers of each manufacturer, with a 36% difference between the highest output from the Allen & Hanburys device and the lowest output device. We conclude that there are important differences in output from these inhalers when used with a spacer, and that substitution of one device with another will not necessarily give equivalent therapy to the patient.

Adrenal Cortex Hormones↗

A strong association between mefloquine and halofantrine resistance and amplification, overexpression, and mutation in the P-glycoprotein gene homolog (pfmdr) of Plasmodium falciparum in vitro.

Stepwise selection for increased mefloquine resistance in a line of Plasmodium falciparum in vitro resulted in increased resistance to halofantrine and quinine, increased sensitivity to chloroquine, and amplification and overexpression of the P-glycoprotein gene homolog (pfmdr1). A point mutation (tyrosine to phenylalanine) noted at amino acid 86 in pfmdr1 in the mefloquine-resistant line W2mef was amplified in more resistant lines derived from it by in vitro selection pressure with mefloquine. Conversely, lines selected for increased chloroquine resistance exhibited a revertant phenotype that was sensitive to mefloquine and halofantrine. These lines also demonstrated increased sensitivity to quinine, loss of amplification of pfmdr1, loss of the mefloquine/halofantrine phenylalanine-86 mutation, and selection for a tyrosine-86 mutation previously associated with chloroquine resistance. These findings provide strong evidence for pfmdr1 mediating cross-resistance to halofantrine and mefloquine in P. falciparum in vitro.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Expired air temperature at the mouth during a maximal forced expiratory manoeuvre.

We have studied the temperature of expired air during a maximal forced expiratory manoeuvre, because this has not previously been fully investigated and it will influence how flow and volume recording devices should be calibrated and used. Temperature was recorded with a fine thermocouple, the response time of which was determined at various gas velocities and for which a correction was made. Recordings during maximal forced expiratory manoeuvres were made on 12 normal subjects and 12 subjects with chronic airflow limitation. The thermocouple was placed in the mouthpiece, so that it was at the level of the lips during a blow. In the normal subjects, the effect of differing inhalation protocols was also determined. In the normal subjects, the mean temperature was 33.6 degrees C at peak expiratory flow (PEF), and 34.4 degrees C at 75% forced vital capacity (FVC), but fell to 33.4 degrees C at FVC. In the subjects with chronic airflow limitation, the temperature was constant at 35.0 degrees C from PEF up to 50% FVC, being significantly higher than in the normals, and fell to 33.5 degrees C at FVC. Expired air temperature up to 50% FVC was significantly negatively correlated with absolute PEF, forced expiratory volume in one second (FEV1) and FVC. In the normals, a slow inhalation through the nose raised the expired temperature by almost 1 degree C throughout the blow, whereas inhaling air at 6 degrees C did not affect expired air temperature. The expired air temperature can vary by up to 3 degrees C between individual subjects, and it is influenced by the route of inhalation and the inspired volume.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗