Search PubMed⌕ Search

Biomedical subjects

P Boraschi

Publications and source records attributed to P Boraschi.

42 records · Page 3Linked to original sources

Ultrasound versus plain film in the detection of pneumoperitoneum.

To evaluate ultrasound (US) versus conventional plain film radiography (CPF) in the detection of pneumoperitoneum, 30 patients with postsurgical pneumoperitoneum and a control group of 22 patients were studied using US and CPF. Sonograms and radiograms were obtained while patients were supine and in left lateral decubitus. The two orthogonal plain films of the abdomen were acquired with a horizontal X-ray beam. The epigastric region and right hypochondrium were investigated with ultrasonography. Four experienced, blinded radiologists examined 160 sonograms and 104 radiograms. Statistical analysis yielded a sensitivity of 75.7% for radiography versus 86% for ultrasonography, a specificity of 89.2% versus 83.5%, an accuracy of 81.5% versus 85%, a positive predictive value of 90.2% versus 87%, and a negative predictive value of 76.2% versus 83.5%, respectively. US could therefore be considered a reliable alternative imaging technique in the detection of pneumoperitoneum.

Adult↗

MR virtual endoscopy of the pancreaticobiliary tract: a feasible technique?

To evaluate the feasibility of magnetic resonance (MR) virtual endoscopy of the pancreaticobiliary tract by using MR cholangiopancreatography (MRCP) data sets as source images, we retrospectively reviewed MRCP data sets of 120 patients with Navigator software (GE/Medical Systems, Milwaukee, WI) that allowed display of inner views by surface rendering the internal wall of the bile ducts with simulated light and shadow.

Adolescent↗

[The computed tomographic diagnosis of malignant pleural mesothelioma. A multicenter study].

CT features are described and accuracy of the method is discussed in the diagnosis of malignant pleural mesothelioma. Ninety-eight patients suffering from pleural disease mimicking mesothelioma were examined by means of III-generation CT scanners; according to the final diagnosis, 37 patients suffered from malignant pleural mesothelioma, 27 from other malignant pleural diseases and 34 from various benign diseases. In all patients a series of CT signs was evaluated: pleural thickening patterns, lesion spread and possible associated characters. In the diagnosis of mesothelioma CT showed 72.5% sensitivity, 63.8% specificity, 68.3% diagnostic accuracy, 68.5% positive predictive value and 68.2% negative predictive value. Some significant CT patterns in distinguishing malignant from benign pleural disease were identified, while the characterization of malignant disease (mesothelioma versus other neoplastic conditions) proved to be unreliable.

Adult↗

[The evaluation of a digital system for the automatic analysis of the density of abdominal radiograms].

This paper reports the results of the evaluation of an automatic system developed to analyze radiographic densities. This system, called RADEN, has been implemented at the Institute for Information Processing of the Italian National Research Council in Pisa. Forty-three pairs of abdominal X-ray films were obtained before and after the administration of ionic iodate contrast medium (i.i.c.m.) during urographic examinations. The 86 X-ray films were acquired and digitized using a computer-controlled optoelectronic device with a sampling step ranging 125 microns to 250 microns. The resulting images were arrays of 512 x 512 pixels, each one quantified on a byte (256 gray levels). The computing system included a high-performance personal computer equipped with a video RAM board having built-in facilities for image processing and with an optical disk to archive the images. Automatic and semi-automatic procedures were developed to segment, recognize and classify the images and to characterize three homogeneous regions--i.e., bone, water and air. The output data were compared with the area values of the air densities computed directly on the X-ray films by a radiologist. Furthermore, both data sets were compared with the scores given in a blind study by four observers. The subsequent statistic analysis showed the increase in air density areas after i.i.c.m. administration and the applicability of the implemented system to the automatic examination of abdominal radiographic densities. The results encourage to believe that the proposed approach could be employed as a first step for the development of quite a more complex system oriented to X-ray image understanding and to assisted diagnosis.

Contrast Media↗