P Bergveld

Publications and source records attributed to P Bergveld.

At least 19 recordsLinked to original sources

The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model.

The influence of subthreshold depolarizing prepulses on the threshold current-to-distance and the threshold current-to-diameter relationship of myelinated nerve fibers has been investigated. A nerve fiber model was used in combination with both a simple, homogeneous volume conductor model with a point source and a realistic, inhomogeneous volume conductor model of a monofascicular nerve trunk surrounded by a cuff electrode. The models predict that a subthreshold depolarizing prepulse will desensitize Ranvier nodes of fibers in the vicinity of the cathode and thus cause an increase in the threshold current of a subsequent pulse to activate these fibers. If the increase in threshold current of the excited node is large enough, the excitation will be accompanied by a strong hyperpolarization of adjacent nodes, preventing the propagation of action potentials in these fibers. As fibers close to the electrode are more desensitized by prepulses than more distant ones, it is possible to stimulate distant fibers without stimulating such fibers close to the electrode. Moreover, as larger fibers are more desensitized than smaller ones, smaller fibers have lower threshold currents than larger fibers up to a certain distance from the electrode. The realistic model has provided an additional condition for the application of this method to invert nerve fiber recruitment, i.e., real or virtual anodes should be close to the cathode. When using a cuff electrode for this purpose, in the case of monopolar stimulation the cuff length (determining the position of the virtual anodes) should not exceed twice the internodal length of the fibers to be blocked. Similarly, the distance between cathode and anodes should not exceed the internodal length of these fibers when stimulation is to be applied tripolarly.

Animals↗

A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors.

A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 microm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few microl of an appropriate enzyme solution, an amperometric enzyme sensor results. As the dialysis tubing is impermeable for large molecular species such as enzymes, this approach does not require any immobilization chemistry, and as a consequence the enzyme is present in its natural free form. Based on this principle, amperometric sensors for lactate, glucose, and glutamate were formed by filling cavities, precision machined in Perspex, with buffered solutions containing respectively, lactate-, glucose-, and glutamate-oxidase. All sensors showed a large linear range (0-35 mM for glucose, 0-3 mM for lactate, and 0-5 mM for glutamate) covering the complete physiological range. The lower detection limit was in the order of 15-50 microM. Applicability in flow injection analysis systems is demonstrated.

Biosensing Techniques↗

Nerve stimulation with a multi-contact cuff electrode: validation of model predictions.

The recruitment characteristics of muscle selective nerve stimulation by a multi-contact nerve cuff electrode, as predicted by computer modeling, have been investigated in acute experiments on rabbits. A nerve cuff containing five or six dot electrodes was placed around the sciatic nerve in five rabbits. M-waves were recorded with wire electrodes from the lateral gastrocnemius, soleus, tibialis anterior, and extensor digitorum longus muscles. The muscle recruitment performances of three contact configurations (monopole, transverse bipole, transverse tripole) were compared. The selectivity was quantified by the recruitment of two muscles (one extensor and one flexor) in response to a particular stimulus. The results showed that only in a few cases, transverse bi- and tripolar stimulation provided a better selectivity than monopolar stimulation. Neither of the two extensors, nor of the two flexors could be stimulated separately. In accordance with the results of the modeling studies, bi- and tripolar stimulation required higher stimulus currents than monopolar stimulation, whereas maximum recruitment and slopes of recruitment curves were lower. The rabbit sciatic nerve appears to be a less suitable preparation for reproducible selectivity experiments, due to the variability in the number and size of the fascicles and their position in this nerve.

Animals↗

Constructing a Proton Titration Curve from Ion-Step Measurements, Applied to a Membrane with Adsorbed Protein

A new measuring method is described for obtaining a proton titration curve. The curve is obtained from a microporous composite membrane, consisting of polystyrene beads in an agarose matrix, with lysozyme molecules adsorbed to the bead surface. The membrane is incorporated into a sensor system by deposition on a silicon chip with a pH-sensitive ion-sensitive field effect transistor (ISFET) located in the middle of a Ag/AgCl electrode. The actual measurement is performed by creating a stepwise change in the salt concentration of the bathing electrolyte (the ion step) and measuring the ISFET potential versus the Ag/AgCl electrode. This potential shows a transient change in the ion step, which indicates a transient pH change in the membrane. This procedure is repeated at a series of pH values. Equations are presented to calculate the proton titration curve of the membrane from the amplitude and duration of the measured transients. Measurements show qualitative agreement between the curves obtained and equilibrium titration experiments on the same system.

Journal Article↗

The ISFET based heparin sensor with a monolayer of protamine as affinity ligand.

The ion-step measuring method was used to determine absolute heparin concentrations in PBS and blood plasma with a Ta2O5 ISFET on to which a monolayer of protamine had been immobilized. Heparin is a highly negatively charged polysaccharide, which is used clinically to delay the clotting of blood. Protamine acts as an affinity ligand for heparin. The response of the ISFET system on a step-wise increase in the electrolyte concentration (a so-called ion-step) is a transient change of the output voltage, which is related to the surface charge density of the ISFET gate oxide. After 2 mins of incubation in a plasma sample containing heparin, the amplitude of the transient ISFET response to an ion-step showed a linear relation to the heparin concentration. In blood plasma, heparin concentrations between 0.3 and 2.0 Units/ml could be determined with an accuracy of +/- 0.08 Units/ml. Heparin concentrations in different plasma samples of heparinized patients were determined and compared with the APTT. No direct relation was found between the APTT and the heparin concentration, but this result was not surprising.

Biosensing Techniques↗

Simulation of multipolar fiber selective neural stimulation using intrafascicular electrodes.

A realistic, quantitative model is presented for the excitation of myelinated nerve fibers by intrafascicular electrodes. It predicts the stimulatory regions of any configuration of any number of electrodes, positioned anywhere inside the fascicle. The model has two parts. First, the nerve fiber is represented by a lumped electrical network and its response to an arbitrary extracellular potential field is calculated. Second, assuming a cylindrical geometry of the nerve bundle and its surroundings, an analytical expression for this field is derived. With realistic parameters, the model is applied to two cases: monopolar stimulation by a single cathode and stimulation by a specific tripolar configuration. It is shown that tripolar stimulation has the better spatial selectivity. Also tripolar stimulation is less sensitive to the conductivity of the medium surrounding the nerve and yields a more natural recruitment order.

Electric Conductivity↗

Optimal design of an electret microphone metal-oxide-semiconductor field-effect transistor preamplifier.

A theoretical noise analysis of the combination of a capacitive microphone and a preamplifier containing a metal-oxide-semiconductor field-effect transistor (MOSFET) and a high-value resistive bias element is given. It is found that the output signal-to-noise ratio for a source follower and for a common-source circuit is almost the same. It is also shown that the output noise can be reduced by making the microphone capacitance as well as the bias resistor as large as possible, and furthermore by keeping the parasitic gate capacitances as low as possible and finally by using an optimum value for the gate area of the MOSFET. The main noise source is the thermal noise of the gate leakage resistance of the MOSFET. It is also shown that short-channel MOSFETs produce more thermal channel noise than longer channel devices.

Amplifiers, Electronic↗

A critical evaluation of direct electrical protein detection methods.

During the last decennia many protein-related electrical phenomena have been studied and applied in a variety of measuring systems, from simple metal electrodes with adsorbed proteins to sophisticated systems with lipid bilayers. Many of the investigations concern the monitoring of immuno reactions. The basic underlying electrical effects of the observed phenomena are the protein modulated dielectric constant, conductivity, electrical potential, ion permeability and ion mobility. In this paper special attention is paid to the capacitive measurements with EIS systems as well as impedance and potential measurements with FET devices. The Donnan theory is treated and applied to the static ImmunoFET operation, explaining the relatively small effects which have been reported. Finally, an alternative approach is described in which the ImmunoFET is applied in a dynamic way, to circumvent the drawbacks of the static measurements.

Amino Acid Sequence↗

pH measurements with an ion sensitive field effect transistor in the mouth of patients with xerostomia.

A transistor pH electrode (ion sensitive field effect transistor), placed in the upper dentures of eleven xerostomia patients and five healthy volunteers, was used to register pH changes in five-, six- and seven-day-old dental plaque. A mouth rinse with a 10% sucrose solution caused a pH fall of about three decades. A significant difference in duration of critical plaque pH was observed: in xerostomia patients, a 10% longer period of pH less than 5.7 was registered during 60 min following a sucrose rinse. Normal oral functions were not influenced by the denture with an integrated electrode. This method is usable for plaque pH registration in xerostomia patients.

Calibration↗

A new approach to immunoFET operation.

A new method is presented for the detection of an immunological reaction taking place in a membrane, which covers the gate area of an ISFET. By stepwise changing the electrolyte concentration of the sample solution, a transient diffusion of ions through the membrane-protein layer occurs, resulting in a transient membrane potential, which is measured by the ISFET. The diffusion rate is determined by the immobile charge density in the amphoteric protein layer, which changes upon formation of antibody-antigen complexes. No membrane potential is induced at zero fixed charge density as occurs at a protein characteristic pH. Isoelectric points of embedded proteins can be determined by detecting the zero potential response. Up to now, the authors have studied the membrane adsorption of lysozyme, human serum albumin (HSA) and the immune reaction of HSA with the antibody anti-human serum albumin (alpha HSA). The influence of protein parameters on the amplitude of the transient can be described with an empirical equation. Assuming Langmuir behaviour, the protein concentration in the solution can well be correlated with the concentration in the membrane. This new detection method is unique concerning direct measurements of charge densities and isoelectric points of amphoteric macromolecules adsorbed in the membrane. The simple procedure of one incubation stage followed by one detection stage, without separate washing and labelling techniques, gives direct information about specific charge properties of the macromolecules to be studied.

Antigen-Antibody Reactions↗

The development and application of FET-based biosensors.

After having considered the general definition of biosensors, the specifications of one type are discussed here in more detail, namely the pH-sensitive ISFET, which is at present being clinically investigated for intravascular blood pH recording. Results, advantages and possible improvements will be discussed, as well as a prediction with respect to future developments of FET-based biosensors.

Biological Products↗