Search PubMed⌕ Search

Biomedical subjects

P Bühlmann

Publications and source records attributed to P Bühlmann.

6 recordsLinked to original sources

Influence of calcium and phosphorus, lactose, and salt-to-moisture ratio on Cheddar cheese quality: pH buffering properties of cheese.

The pH buffering capacity of cheese is an important determinant of cheese pH. However, the effects of different constituents of cheese on its pH buffering capacity have not been fully clarified. The objective of this study was to characterize the chemical species and chemical equilibria that are responsible for the pH buffering properties of cheese. Eight cheeses with 2 levels of Ca and P (0.67 and 0.47% vs. 0.53 and 0.39%, respectively), residual lactose (2.4 vs. 0.78%), and salt-to-moisture ratio (6.4 vs. 4.8%) were manufactured. The pH-titration curves for these cheeses were obtained by titrating cheese:water (1:39 wt/wt) dispersions with 1 N HCl, and backtitrating with 1 N NaOH. To understand the role of different chemical equilibria and the respective chemical species in controlling the pH of cheese, pH buffering was modeled mathematically. The 36 chemical species that were found to be relevant for modeling can be classified as cations (Na+, Ca2+, Mg2+), anions (phosphate, citrate, lactate), protein-bound amino acids with a side-chain pKa in the range of 3 to 9 (glutamate, histidine, serine phosphate, aspartate), metal ion complexes (phosphate, citrate, and lactate complexes of Na+, Ca2+, and Mg2+), and calcium phosphate precipitates. A set of 36 corresponding equations was solved to give the concentrations of all chemical species as a function of pH, allowing the prediction of buffering curves. Changes in the calculated species concentrations allowed the identification of the chemical species and chemical equilibria that dominate the pH buffering properties of cheese in different pH ranges. The model indicates that pH buffering in the pH range from 4.5 to 5.5 is predominantly due to a precipitate of Ca and phosphate, and the protonation equilibrium involving the side chains of protein-bound glutamate. In the literature, the precipitate is often referred to as amorphous colloidal calcium phosphate. A comparison of experimental data and model predictions shows that the buffering properties of the precipitate can be explained, assuming that it consists of hydroxyapatite [Ca5(OH)(PO4)3] or Ca3(PO4)2. The pH buffering in the region from pH 3.5 to 4.5 is due to protonation of side-chain carboxylates of protein-bound glutamate, aspartate, and lactate, in order of decreasing significance. In addition, pH buffering between pH 5 to 8 in the backtitration results from the reprecipitation of calcium and phosphate either as CaHPO4 or Ca4H(PO4)3.

Buffers↗

Influence of natural, electrically neutral lipids on the potentiometric responses of cation-selective polymeric membrane electrodes.

Ionophore-free ion exchanger electrodes were found to exhibit quite a high selectivity for the creatininium ion; however, measurements in diluted urine samples revealed large emf drifts. Potentiometric, chromatographic, NMR, and mass spectrometric evidence did not reveal any major cationic interfering agents, and anionic interfering agents cannot trivially explain the consistently positive emf drifts. Ultrafiltration of urine samples showed that the interfering agents have molecular weights below 1000 u. The drifts are apparently caused by electrically neutral lipophilic compounds of low molecular weight that are easily extracted into organic phases. Follow-up experiments showed that p-cresol and cholesterol cause no significant emf responses but that coproporphyrin, phosphatidylserine, taurocholic acid, cholic acid, phosphatidylethanolamine, and octanoic acid cause positive emf drifts of the type that was observed with the urine samples. The extent of the responses and the response time depend not only on the specific compound but also on the cation in the sample solution. These results suggest that the emf drifts are due to extraction of such natural lipids into the organic membrane phase where they interact in an ionophore-like fashion with the analyte and interfering ions. Changes in the potentiometric selectivities after contact with natural lipids support this interpretation. The same effect of natural lipids is also expected for ionophore-based electrodes. Indeed, exposure of a valinomycin-based electrode to a methylene chloride extract of urine resulted in a significant reduction of the Na+ discrimination, increasing log Kpot(K,Na) from -3.9 to -3.1.

Cations↗

Scanning tunneling microscopy with chemically modified tips: discrimination of porphyrin centers based on metal coordination and hydrogen bond interactions.

STM gold tips chemically modified with 4-mercaptopyridine (4MP) were found capable of discriminating zinc(II) 5,15-bis(4-octadecyloxyphenyl)porphyrin (Por-Zn) from its metal-free porphyrin (Por-2H) and nickel(II) complexes (Por-Ni) in the mixed monolayers of these compounds, spontaneously formed at the solution/graphite interface. The porphyrin centers in STM images observed with 4MP-modified tips exhibited bright spots, while those measured with unmodified tips exhibited the porphyrin centers as dark depressions. The centers of Por-Zn were brighter than those of Por-2H and Por-Ni, thereby allowing the discrimination of Por-Zn from Por-2H or Por-Ni in mixed monolayers. The changes in the contrasts of porphyrin centers of Por-2H and Por-Zn/ Por-Ni were explained by facilitated electron tunneling due to hydrogen bond and metal coordination interactions, respectively, between porphyrin centers and the pyridyl group of 4MP on the tip.

Hydrogen Bonding↗

Origin of non-Nernstian anion response slopes of metalloporphyrin-based liquid/polymer membrane electrodes.

The origin of the non-Nernstian potentiometric anion response behavior exhibited by several metalloporphyrin-based liquid/polymeric membrane electrodes is examined. UV-visible spectrophotometry of organic-phase solutions and thin plasticized PVC films containing In(III) and Ga(III) octaethylporphyrins suggests that, in the absence of preferred axial coordination anions, the metalloporphyrins form hydroxide ion bridged dimers within the organic phases, as indicated by a significant blue shift of the Soret band in the visible spectrum. As increasing levels of the preferred anions are added, the degree of dimerization decreases and the intensity of the Soret band corresponding to the monomer species increases. Observation of Nernstian responses with membranes doped with picket fence-type In(III) and Ga(III) porphyrins not capable of forming hydroxide bridged structures (as determined by UV-visible spectroscopy) confirms that dimerization is likely responsible for the super-Nernstian slopes of membrane electrodes formulated with the non-picket fence species. A phase boundary model based on simultaneous binding equilibria of hydroxide ions with two metalloporphyrins to form the dimeric species, while the target anions bind with metalloporphyrins to form neutral 1:1 complexes, is shown to fully predict the observed non-Nernstian behavior. The prospect of utilizing this anion-dependent dimer-monomer metalloporphyrin equilibrium to fabricate anion-selective optical sensors using thin films of metalloporphyrin-doped polymers is also discussed.

Electrodes↗

Selectivity of potentiometric ion sensors.

Selectivities of solvent polymeric membrane ion-selective electrodes (ISEs) are quantitatively related to equilibria at the interface between the sample and the electrode membrane. However, only correctly determined selectivity coefficients allow accurate predictions of ISE responses to real-world samples. Moreover, they are also required for the optimization of ionophore structures and membrane compositions. Best suited for such purposes are potentiometric selectivity coefficients as defined already in the 1960s. This paper briefly reviews the basic relationships and focuses on possible biases in the determination of selectivity coefficients. The traditional methods to determine selectivity coefficients (separate solution method, fixed interference method) are still the same as those originally proposed by IUPAC in 1976. However, several precautions are needed to obtain meaningful data. For example, errors arise when the response to a weakly interfering ion is also influenced by the primary ion leaching from the membrane. Wrong selectivity coefficients may be also obtained when the interfering agent is highly preferred and the electrode shows counterion interference. Recent advances show how such pitfalls can be avoided. A detailed recipe to determine correct potentiometric selectivity coefficients unaffected by such biases is presented.

Artifacts↗

What is a linear process?

We argue that given even an infinitely long data sequence, it is impossible (with any test statistic) to distinguish perfectly between linear and nonlinear processes (including slightly noisy chaotic processes). Our approach is to consider the set of moving-average (linear) processes and study its closure under a suitable metric. We give the precise characterization of this closure, which is unexpectedly large, containing nonergodic processes, which are Poisson sums of independent and identically distributed copies of a stationary process. Proofs of these results will appear elsewhere.

Linear Models↗