Clinical usefulness of the glucose concentration in the subcutaneous tissue--properties and pitfalls of electrochemical biosensors.

Biosensors are miniaturized analytical tools which comprise a biological detection element providing specificity to the analyte, and a physical transducer which guarantees an output signal, e.g. an electric current the size of which is proportional to the concentration of the analyte. They provide the unique possibility of continuous in vivo monitoring. Glucosensors were in fact the first biosensors under study. Among them, the most advanced devices are measuring amperometrically the hydrogen peroxide generated in a stoichiometric relation to the prevailing glucose concentration during glucose oxidase-mediated glucose oxidation. They proved useful in commercially available glucose analyzers and in experimental subcutaneous monitoring. Here it is shown (a) that under steady state conditions the s.c. glucose concentration is nearly identical to that in blood, (b) that s.c. inserted glucose electrodes do mirror the intracorporal glucose concentration both under hypo-, normo-, and hyperglycaemic conditions with a clinically relevant accuracy, (c) that even stable feedback control of intracorporal glucose concentration is possible employing s.c. glucosensor signal as an input to automated insulin pump controller, and (d) that stable function of s.c. sensor is usually accomplished over intervals up to one day but in some cases applications over up to ten days could be realized. The underlying problem consists in an insufficient functional biostability which is a function of biocompatibility and size of the sensor, of its sterility, and of the permanent skin penetration. The latter is still required to get the device in place, to keep it in function, and to make use of the data under any condition.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Implantation of non-toxic materials from glucose sensors: evidence for specific antibodies detected by ELISA.

After subcutaneous implantation of glucose sensors into LEW.1A rats, antibodies could be detected by means of enzyme-linked immunosorbent assay against the outer membrane (cellulose acetate) but not against either the inner membrane (polyethylene) or glucose oxidase (GOD). The kinetics of humoral immune response were investigated implanting different polymeric membranes such as polyurethane, cellulose acetate, regenerated cellulose. The highest antibody titer was detected against regenerated cellulose. There was no cytotoxic effect in vitro by any of the tested materials as examined on monolayer cultures of the mouse fibroblast cell line L-929. Thus immunogenicity is suggested to be considered as a parameter in biocompatibility testing of implantable medical devices.

Animals↗

Levels of matrix metalloproteases in bladder cancer correlate with tumor grade and invasion.

We have used quantitative zymography to measure levels of the type IV collagenases matrix metalloproteinase (MMP)-9 and MMP-2 in 42 biopsies of transitional cell carcinoma and in 7 biopsies of normal bladder. Mean levels of MMP-9 were significantly higher in tumor compared with normal samples (P = 0.08). Levels of MMP-9 and active MMP-2 increased with tumor grade (test for trend, P = 0.002 and P = 0.05, respectively). Levels of MMP-9 and activated MMP-2 were also higher in invasive tumors than in superficial ones (P = 0.001 and P = 0.008, respectively). In situ hybridization studies showed that the mRNAs for both MMP-2 and MMP-9 were located chiefly in the stroma rather than epithelial tumor cells and were concentrated at the interface between the two tissues.

Carcinoma, Transitional Cell↗

Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?

Amperometric glucose oxidase/hydrogen peroxide sensors were inserted subcutaneously into the neck of normal and diabetic dogs (n = 10), to elucidate the conditions for stable long-term functioning. Their output current was observed in parallel with measurements of plasma glucose concentrations and their function was checked by means of induced alterations in glycaemia. After between 14 and 96 h the experiments were terminated due to losses in the apparent sensitivity of implanted sensors and/or increasing oscillations following stable measurements. This was accompanied by an inflammatory reaction which was analysed on the basis of the clinical picture and histology. In most cases there was a bacterial ingrowth from the normal skin flora of dogs. The inflammatory exsudate contained only 23 +/- 17% of the simultaneous steady state plasma glucose concentration, which was significantly different from the glucose level in the fluid obtained from non-irritate subcutaneous tissue (95 +/- 12%, separate set of experiments). The in vitro calibration of sensors exhibited essentially comparable sensitivities before and after the in vivo application. No differences in reported findings related to the biomaterials used (polyurethane versus cellulose acetate), the presence of diabetes, the history of individual electrodes and the effective duration of a given experiment were discernible. We conclude that the functional bioinstability of subcutaneous glucose sensors is largely due to the inflammatory tissue reaction which alters the effective glucose concentration within the measuring compartment of the electrodes; these drawbacks may be overcome by further miniaturization including implantable telemetric devices allowing the closure of the skin.

Animals↗

Bladder cancer: inter-relationships between chemotherapy and radiotherapy.

There has been increasing interest in the role of chemotherapy as primary treatments for patients with urothelial cancer and because of the poor prognosis of locally advanced tumours with conventional treatment, trials have been initiated comparing radiotherapy with chemotherapy as primary therapies. In this context it is important to assess the relationship between the responses to chemotherapy and radiotherapy, and this we have examined in 64 patients treated with MVMJ (methotrexate, vinblastine, mitozantrone and carboplatin). Either a complete or a partial response was found in 29 of the 64 patients, 15 had stable disease and 13 had progression of disease. Seven patients died within the first treatment month. The survival of the responding patients ranged from 114 to 1184 days. Six of 15 patients who had had pelvic irradiation prior to chemotherapy responded to MVMJ, the maximum duration of response being more than 3 years. Twenty-two patients had radiotherapy following their chemotherapy. One of 13 patients not responding to MVMJ had a transient response to radical radiotherapy. Only 1 of 9 patients responding to chemotherapy and then relapsing responded to subsequent radical radiotherapy. Patients with metastatic disease or with recurrent disease after radiotherapy have a worthwhile chance of responding to chemotherapy and achieve durable remissions. In contrast, radiotherapy appears relatively ineffective in patients whose disease progresses or relapses after chemotherapy given as primary treatment with curative intent.

Adult↗

Detection of blood group A and H-related antigens in normal and neoplastic bladder epithelium: a comparative study using monoclonal antibodies with defined fine specificities.

Three monoclonal anti-blood group H and four monoclonal anti-blood group A antibodies directed at the blood group antigens on Type 1 or Type 2 backbone structures were evaluated as immunohistochemical reagents by indirect immunofluorescence of normal and neoplastic bladder epithelia. The results were compared with fluorescence using polyclonal rabbit anti-A or H sera or Ulex europaeus lectin. The monoclonal antibodies gave less intense or more restricted immunofluorescence than the conventional reagents but showed considerable variation in the extent of their reactivities with urothelial samples from different individuals. In some cases they failed to give immunofluorescence with tissue samples known to contain the immunodominant blood group structures they recognize. In addition, hitherto unsuspected heterogeneity was revealed in the expression of the Type 2-based blood group H and A-structures in the endothelia of neighbouring small blood vessels.

ABO Blood-Group System↗

Implantable glucose sensors: comparison between in vitro and in vivo kinetics.

This study was aimed at validating the in vitro estimated response characteristics of implanted glucose oxidase/H2O2 electrodes with respect to their in vivo function. Monoexponential non-linear regression analysis of sensor current vs. time curves in response to square alterations in glucose concentration gave response times T95 of between 1 and 5 min. Non-primed glucose infusions were applied to dogs with these electrodes implanted subcutaneously. The simultaneously monitored in vivo data were subjected to non-linear regression analysis. The time constants T of increases or decreases after starting or ending the glucose load were (mean +/- SEM) 53 +/- 10 and 26 +/- 4 min (significant difference, p less than 0.05) in sensor current, 28 +/- 8 and 15 +/- 2 min (NS) in whole blood, and 26 +/- 5 and 18 +/- 2 min (NS) in plasma. The in vivo kinetic patterns of sensors were not related to their in vitro response times. Non-linear regression analysis of in vitro responses of glucose sensors under clearly defined conditions is recommended as a basis for further studies. The physiological delay in the subcutaneous glucose system needs more attention in this field of research.

Animals↗

Three-monthly GnRH agonist (buserelin) for prostatic cancer.

A new slow release formulation of buserelin given as a 3-monthly depot injection has been evaluated in 4 patients with advanced prostatic cancer previously maintained on shorter acting depots. Treatment was maintained for a mean period of 21 months. Steady state urinary buserelin concentrations were reached by the beginning of the third treatment week and maintained until the end of the third treatment month. Serum testosterone remained suppressed in the castrate range for the duration of the study. Seven previously untreated patients were entered into treatment. Serum testosterone was suppressed into the castrate range between the seventh and fourteenth days after implantation. This preparation offers an advantage for the patient and clinician over existing methods of GnRH analogue administration and will now enter further clinical trial.

Buserelin↗

[Continuous intracorporeal glucose measurement using enzyme electrodes].

An enzyme electrode (GOD, Pt-Ag/AgCl) is introduced for amperometric measurement of the intracorporal glucose concentration in the subcutaneous tissue. Changes of the glucose concentration in the peripheral blood (PG) were induced by glucose- respectively insulin-infusion in healthy dogs. PG was compared with values found by out means of a sensor implanted in the necks of the dogs (SG). The regression equation SG = 0.81 PG - 1.39 was calculated by analysing 62 steady state levels. The regression delta SG = 0.83 delta PG + 0.22 submitted for the deviation of the normoglycemic base-level. A sensibility loss of the sensor of about 10% appears after an implantation duration of 7.5 hours in medium. Conclusions for the further development of the sensors follows especially with the in vivo functions (biocompatibility, diminution, sterilisation).

Animals↗

Automated feedback control of subcutaneous glucose concentration in diabetic dogs.

The subcutaneous tissue is generally considered as a potential site for the monitoring of intracorporal glucose concentration by means of implanted sensors. We studied the suitability of using the resulting signal from the interstitial glucose concentration as an input in a feedback-controlled system for insulin administration. Miniaturized glucose electrodes (amperometric glucose oxidase sensors for the measurement of hydrogen peroxide) were implanted in insulin-dependent diabetic dogs. The output of these sensors was fed into the controller of a bedside-type artificial B cell. Insulin was infused by the device intravenously on the basis of a proportional-differential algorithm. The glucose patterns were compared to identical experiments where feedback control was accomplished on the basis of paracorporal blood glucose measurement using the same algorithm. Normoglycaemia was restored and maintained in both sets of experiments and oral glucose loads were well compensated for. It is concluded that the apparent subcutaneous glucose concentration is appropriate as an input signal for an artificial B cell.

Animals↗

New combination chemotherapy programme for bladder cancer.

Forty patients with either metastatic, post-radiotherapy recurrent, or poor prognosis locally advanced transitional cell carcinoma of the bladder were treated in a new combination chemotherapy programme with methotrexate, vinblastine, mitozantrone and JM8 (carboplatin); 33 patients were assessable for response. There were 9 complete responses (27%), 12 partial responses (36%) and 7 disease stabilizations (21%); 5 patients (15%) had progressive disease. The median duration of complete response has not been reached and is in excess of 9 months (range 4- greater than 18 months). This regimen was without significant toxicity and this is in contrast with M-VAC, which is thought to be currently the most effective treatment for urothelial cancer.

Adult↗

Two-monthly depot gonadotropin releasing hormone agonist (buserelin) for treatment of prostatic cancer.

The agonist analogues of gonadotropin-releasing hormone provide an alternate medical therapy for prostatic cancer. Current methods of administration of these analogues by daily injection or nasal spray is sub-optimal in an elderly population. We have performed a pharmacological and endocrine evaluation of a new depot preparation of one such analogue, buserelin, active for 2 months. Thirty patients with advanced symptomatic prostatic cancer were treated. Serum testosterone was suppressed for the duration of treatment which ranged up to 14 months. The release characteristics of the depot were consistent and showed minimal variation between patients. This 2-month preparation of buserelin offers and advantage to the patient with prostatic cancer, over current treatment regimens.

Adult↗

Preparation and validation of implantable electrodes for the measurement of oxygen and glucose.

In realizing the continuous measurement of pO2 and glucose concentration in the subcutaneous tissue, miniaturized electrochemical oxygen- and enzyme glucose sensors, based on modified Clark-type electrodes for transient implantation, were developed and investigated. The electrodes were prepared by means of sequential dipping procedures in glucose oxidase and in different polymer solutions at well-defined environmental conditions in an incubator. By means of combining a hydrophobic membrane with a glucose permeable area and a hydrophilic membrane in the case of the glucose sensor, linearity of the glucose dependent electrode signal up to greater than 20 mmol/l could be achieved. After subcutaneous implantation in the neck of dogs, the enzyme sensor is able to follow glucose profiles in the normo- and in the hyperglycaemic range, e.g. as caused by oral glucose loads. Looking for the difference in sensitivity of the enzyme sensor measured in vitro and calculated from in vivo data, the influence of potential nonspecific, interfering substances in vivo such as urea, amino acids, electrolytes, and albumin was estimated.

Blood Glucose↗

In situ calibration of implanted electrochemical glucose sensors.

A feasible and reliable method of in situ checking and calibration of implanted glucose sensors is required to compensate for alterations in the overall sensitivity of the "sensor plus subcutaneous fluid glucose compartment" system. In a study on nondiabetic dogs, the linear regression analysis of paired plasma glucose/sensor current data is validated as a potential basis of recalibration of intracorporal glucose sensors. These sensors were amperometric glucose oxidase/hydrogen peroxide electrodes of which the in vitro response time to square alterations in the ambient glucose concentration T95 was less than 5 min. The method presented may be incorporated into the data handling system of portable glucose monitors or of miniaturized artificial beta-cells. For its performance, no steady state glycaemia but a minimum alteration in the intracorporal glucose concentration is needed. The latter can be provided both by tests or by fluctuations as they occur spontaneously during the course of the day.

Animals↗

Oxygen tension at the subcutaneous implantation site of glucose sensors.

To elucidate potential influences of the average tissue pO2 on the function of implanted glucose sensors, non-miniaturized polarographic oxygen electrodes and glucose oxidase/H2O2 glucose electrodes were implanted in the subcutaneous tissue of spontaneously breathing normal and diabetic dogs. There was no appreciable run-in phenomenon of oxygen sensors but normally a pronounced initial decrease in current after implantation of glucose sensors. The subcutaneous pO2 amounted to an average of 7 kPa in air-breathing animals with no difference between normal and insulin-dependent diabetic dogs. It showed oscillations of approximately +/- 2 kPa but the mean was stable over the maximum duration of experiments of 16 h. Induced alterations of tissue pO2 between less than 2 and greater than 20 kPa (as verified by measurements of arterial pO2) were not followed by alterations in the current of nearby implanted glucose sensors. It is concluded that the frequently observed instabilities and losses in sensitivity of the system "implanted glucose sensor in situ + tissue glucose compartment" are not caused by alterations in tissue pO2.

Animals↗