Search PubMedSearch

Biomedical subjects

P A Bascom

Publications and source records attributed to P A Bascom.

9 recordsLinked to original sources

Experimental study of the effects of pulsed Doppler sample volume size and position on the Doppler spectrum.

With a pulsed Doppler system, the recorded Doppler spectrum is expected to vary depending upon the sample volume size relative to the diameter of the vessel, the position of the sample volume in the vessel and the velocity profile. In the in vitro experiments described in this paper, the velocity profile was kept constant by using steady parabolic flow in a flow model. As the Doppler sample volume size and position were changed, the maximum variations of quantitative measurements from the Doppler spectrum were determined. The maximum, mean and mode frequencies and spectral broadening index (SBI) were affected by the position of the sample volume but to a lesser degree by its length (1.5-5.0 mm) relative to the 9.5 mm beam path length across the tube. When the centre of the Doppler sample volume was moved within the central 25% of the tube, the maximum variations were as follows: maximum frequency 3-5%, mean frequency 8-9%, mode frequency 8-9% and SBI 16-18%, where the range indicates the effect of increasing the sample volume size. Based on these results obtained under steady flow conditions in vitro, it is concluded that quantification of pulsed Doppler spectra may be feasible if the sample volume is positioned within the central 25% of the vessel.

Blood Flow Velocity

Development of methods to analyse transcranial Doppler ultrasound signals recorded in microgravity.

During space flights, several clinical syndromes may be the result of changes in cerebral circulation. The purpose of the paper is to describe the development and initial evaluation of a system for recording, processing and displaying transcranial Doppler ultrasound (TCD) waveforms from the middle cerebral artery (MCA) in microgravity. Volunteers were repeatedly subjected to 15-20 s intervals of microgravity ('near zero gravity') during flights on the KC-135 military aircraft. Continuous TCD recordings from the MCA were stored on magnetic tape. The paper describes the system that was developed to digitise the Doppler ultrasound data and markers that corresponded to the various levels of microgravity, obtain the maximum and mean Doppler waveforms, identify the waveforms and quantify them. The results demonstrate the feasibility of making TCD recordings in a microgravity environment and illustrate excellent performance of the system and its ease of operation. Quantitative waveform analysis of the recordings from the first subject studied in the supine position showed statistically significant changes in MCA velocity waveforms during microgravity.

Cerebral Arteries

Effects of transducer beam geometry and flow velocity profile on the Doppler power spectrum: a theoretical study.

A theoretical model is used to show how the Doppler spectrum for various axisymmetric velocity profiles is affected by beam misalignment and incomplete insonation. Results are presented for both circular and square beam geometries. Moreover, a closed-form expression is derived for the power spectral density received by an on-axis transducer with a Gaussian beam profile. It is shown that the error incurred in measuring the mean Doppler frequency with such a profile will generally be bounded by the results for the circular and square beam geometries. The effects of an ideal high-pass filter on the mean Doppler frequency and the backscattered Doppler power are examined. It is shown that such a filter can introduce large differences in the measured systolic to diastolic power ratios. Finally, theoretical expressions and results are presented for the spectral broadening index (SBI), normalized spectral variance (NSV), coefficient of kurtosis (CK), the coefficient of skewness (CS) as functions of the axisymmetric velocity profile shape assuming complete uniform insonation.

Blood Flow Velocity

Effect of placental resistance, arterial diameter, and blood pressure on the uterine arterial velocity waveform: a computer modeling approach.

A computer model was used to simulate velocity waveforms that can be visualized in the human uterine artery using Doppler ultrasound. It was found that increasing uteroplacental vascular resistance from normal caused an increase in the systolic/diastolic velocity ratio (S/D) and pulsatility index (PI) of the waveform. Increasing uteroplacental resistance also caused the appearance of a dicrotic notch. Reducing the uterine artery radius increased the S/D and PI and this effect was accentuated at high placental resistance. In contrast, increasing mean arterial pressure in the uterine artery had little effect on S/D and PI. Results suggest that waveform shape abnormalities observed in obstetric patients with pregnancy-induced hypertension are primarily caused by high uteroplacental vascular resistance and a reduced uterine arterial diameter.

Arteries

Role of models in understanding and interpreting clinical Doppler ultrasound.

Mathematical and physical models are essential tools in both fundamental and clinically applied Doppler ultrasound research. In this paper we illustrate a variety of models and show how they can be used to understand and interpret clinical Doppler ultrasound signals, particularly from stenosed arteries. The physical models discussed include both steady and pulsatile flow systems, and also a flow visualization technique that can be used to interpret the Doppler signals at a fundamental hemodynamic level. The mathematical models deal with three different aspects of the Doppler signal: models that describe the mechanism of ultrasound scattering by blood, a model to stimulate the returned Doppler signal and a model that may be used to aid in the analysis of clinical recordings. Each of these models provides a more complete understanding of blood flow through normal and stenosed vessels and contributes to the interpretation of clinical Doppler signals.

Computer Simulation

Uterine artery flow velocity waveforms in normal and growth-retarded pregnancies.

Uterine artery flow velocity waveforms were measured by continuous-wave Doppler ultrasound in 15 normal pregnant women studied from midgestation until term. Results were analyzed by calculation of the pulsatility index and the systolic/diastolic blood velocity [corrected] ratio. Both indices decreased from 16 to 20 weeks (indicating a lowering of resistance) and thereafter remained stable until term. Resistance was lower when waveforms were recorded directly over the placenta or from the uterine artery close to the placenta. A group of women with severe intrauterine growth retardation were also studied. In preeclampsia, uterine artery resistance was increased in almost all patients. In pregnancies complicated by intrauterine growth retardation of non preeclamptic origin, a wide range of results was obtained.

Arteries

A transmission line modelling approach to the interpretation of uterine Doppler waveforms.

An electrical analogue model of an artery that terminates into a vascular bed is presented. The model consists of an uniform transmission line that represents the artery and a load impedance that represents the vascular bed. The transmission line parameters are based on a well-established first-order approximation of the Navier-Stokes equations for fluid flow in distensible tubes. The model can be used to predict the incident and reflected components of both the arterial pressure and flow waveforms. In addition, it can predict the vessel diameter change and the mean blood velocity waveforms. In this study, the model was applied to the uterine artery so that the characteristics of the utero-placental circulation can be related to Doppler ultrasound recordings. It was found that the presence of the dicrotic notch in the uterine artery time-velocity waveform is the result of wave reflection and that a persistent notch past 20 weeks' gestation may be indicative of an abnormally high placental bed resistance. It is shown that the simulation results are consistent with the known physiological data and the clinically recorded uterine Doppler waveforms.

Arteries

Influence of spectral broadening on continuous wave Doppler ultrasound spectra: a geometric approach.

A model is presented that enables the detailed effects of spectral broadening to be calculated for a continuous wave (CW) Doppler system by using geometric boundary arguments. The model assumes a uniform distribution of isotropic scatterers and treats the transmitter and receiver crystals as incremental sources and receivers. Detailed results for rectangular and circular geometries are presented in order to provide a physical understanding of the manner in which spectral broadening arises. Results are given for the circular geometry, to illustrate the manner in which the received spectrum is affected by the transducer size and distance from the vessel.

Blood Flow Velocity