Search PubMed⌕ Search

Biomedical subjects

Olivier Clement

Publications and source records attributed to Olivier Clement.

4 recordsLinked to original sources

Lymph node imaging: basic principles.

Lymph nodes are involved in a wide variety of diseases, particularly in cancer. In the latter, precise nodal staging is essential to guide therapeutic options and to determine prognosis. For long, imaging of the lymphatic system has been limited to lymph vessel,especially via the exclusive use of conventional lymphography, at the expense of invasive procedures and patient's discomfort. Three main technical advances, however, have recently completed the clinical armamentarium for lymph node imaging: first, the refinement of cross sectional imaging, i.e. CT and MRI, combined or not with dedicated contrast agents, has progressively replaced conventional lymphography in oncology situations; second, the development of intra-operative sentinel node mapping has profoundly modified the diagnostic and therapeutic procedures in several cancer situations, mostly melanoma and breast cancer; finally, the increased availability of functional imaging, especially through the use of FDG-PET, has greatly contributed to the accuracy improvement of nodal metastases identification. The aim of this review will thus be to briefly review the anatomy and physiology of the lymphatic systems and to overview the basic principles of up-to-date lymph node imaging.

Contrast Media↗

Comprehensive model for simultaneous MRI determination of perfusion and permeability using a blood-pool agent in rats rhabdomyosarcoma.

To present a new compartmental analysis model developed to simultaneously measure tissue perfusion and capillary permeability in a tumor using MRI and a macromolecular contrast medium. Rhadomyosarcomas were implanted subcutaneously in 20 rats and studied by 1.5-T MRI using a fast gradient echo sequence (2D fast SPGR TR/TE/alpha 13 ms/1.2 ms/60 degrees ) after injection of a macromolecular contrast medium. The left ventricle and tumor signal intensities were converted into concentrations and modeled using compartmental analysis, yielding tumor perfusion F, distribution volume Vdistribution, volume transfer constant Ktrans, rate constant of influx kpe, and initial extraction (fraction) E. Tumor perfusion was F=43+/-29 ml.min-1.100 g-1. The permeability study allowed the measurement of kpe=0.37+/-0.12 min-1 and Ktrans=0.01+/-0.0031 min-1. The blood volume could be assimilated to the distribution volume (Vdistribution=2.9+/-1.01%) since the capillary leakage was small. The simultaneous assessment of perfusion and permeability allowed quantification of the initial extraction (fraction) E=2.34+/-1.05%. Quantification of both tumor perfusion and capillary leakage is feasible using MRI using a macromolecular blood pool agent. The method should improve tumor characterization.

Algorithms↗

Early modifications of hepatic perfusion measured by functional CT in a rat model of hepatocellular carcinoma using a blood pool contrast agent.

Macromolecular contrast-enhanced functional CT was performed to characterize early perfusion changes in hepatocellular carcinoma (HCC). Fourteen rats with chemically induced primary liver tumors ranging pathologically from hyperplasia to HCC and 15 control rats were investigated. Two dynamic CT scans using an experimental macromolecular contrast agent were performed on a single slice 11 and 18 weeks after tumor induction followed by pathological examination. A deconvolution mathematical model was applied, yielding the hepatic perfusion index (HPI), mean transit time (MTT), liver distribution volume (LDV) and arterial, portal and total blood flows (FA, FP, FT). Analysis was performed on one slice per rat, containing overall two hyperplasia, six dysplasia and 15 HCC. On the first scans, HCC at an early pathological stage had a low FP (-30%, P=0.002) but a normal arterial-portal balance. On the scan contemporary to pathology, HCC perfusion parameters showed an inversion of the arterial-portal balance (HPI +212%, P<0.0001), with a high FA (+56%, P=0.002) and a low FP (-69%, P<0.0001). Sensitivity and specificity of detection of HCC by perfusion CT were high (87 and 80%) on late scans; but also on the earlier scans (86 and 65%), even though only one (7%) was visible to the eye. Perfusion-CT allowed early detection of HCC. This technique could contribute in the detection and characterization of liver lesions in clinical studies.

Animals↗

Glucose-receptor MR imaging of tumors: study in mice with PEGylated paramagnetic niosomes.

PURPOSE: To evaluate a magnetic resonance (MR) imaging contrast agent for tumor detection based on paramagnetic nonionic vesicles (niosomes) bearing polyethylene glycol (PEG) and glucose conjugates for the targeting of overexpressed glucose receptors. MATERIALS AND METHODS: Four gadobenate dimeglumine-loaded niosome preparations including nonconjugated niosomes, niosomes bearing glucose conjugates (N-palmitoyl glucosamine [NPG]), niosomes bearing PEG 4400, and niosomes bearing both PEG and NPG were tested. In vitro cellular uptake was measured at electron paramagnetic resonance (EPR) after incubation with human prostate carcinoma, PC3, cells. In vivo distribution was studied at MR imaging 6, 12, and 24 hours after injection, with assessment of tumor, brain, liver, and muscle signal intensity (SI) in 49 mice bearing PC3 cells. Efficiency of targeted contrast agents was assessed with tumor-to-muscle contrast-to-noise ratio (CNR). Testing for differences was performed with analysis of variance followed by a posteriori Fisher test. RESULTS: In vitro, gadolinium could be detected at EPR only in cell pellets incubated with niosomes bearing glucose conjugates or niosomes bearing both glucose conjugates and PEG (4.9. 10(-15) and 4.5. 10(-15) mol gadolinium per PC3 cell). In vivo, marked predominant tumor enhancement was demonstrated 24 hours after injection of glycosylated PEG niosomes (P <.01); no significant differences were observed following injection of nonconjugated niosomes, glycosylated niosomes, or PEG 4400 niosomes. Twenty-four hours after injection, sole presence of NPG or PEG 4400 on the surface of the niosome led to higher tumor-to-muscle CNR than that observed after injection of nonconjugated niosomes (CNR of 3.3 +/- 0.7 [SD], 3.4 +/- 2.2, and 0 +/- 1.9). Combination of NPG and PEG led to even higher tumor-to-muscle CNR (6.3 +/- 2.2). CONCLUSION: Combination of PEG and glucose conjugates on the surface of niosomes significantly improved tumor targeting of an encapsulated paramagnetic agent assessed with MR imaging in a human carcinoma xenograft model.

Animals↗