Search PubMed⌕ Search

Biomedical subjects

O Smedby

Publications and source records attributed to O Smedby.

At least 19 recordsLinked to original sources

Three-dimensional drip infusion CT cholangiography in patients with suspected obstructive biliary disease: a retrospective analysis of feasibility and adverse reaction to contrast material.

BACKGROUND: Computed Tomography Cholangiography (CTC) is a fast and widely available alternative technique to visualise hepatobiliary disease in patients with an inconclusive ultrasound when MRI cannot be performed. The method has previously been relatively unknown and sparsely used, due to concerns about adverse reactions and about image quality in patients with impaired hepatic function and thus reduced contrast excretion. In this retrospective study, the feasibility and the frequency of adverse reactions of CTC when using a drip infusion scheme based on bilirubin levels were evaluated. METHODS: The medical records of patients who had undergone upper abdominal spiral CT with subsequent three-dimensional rendering of the biliary tract by means of CTC during seven years were retrospectively reviewed regarding serum bilirubin concentration, adverse reaction and presence of visible contrast media in the bile ducts at CT examination. In total, 153 consecutive examinations in 142 patients were reviewed. RESULTS: Contrast media was observed in the bile ducts at 144 examinations. In 110 examinations, the infusion time had been recorded in the medical records. Among these, 42 examinations had an elevated bilirubin value (>19 micromol/L). There were nine patients without contrast excretion; 3 of which had a normal bilirubin value and 6 had an elevated value (25-133 micromol/L). Two of the 153 examinations were inconclusive. One subject (0.7%) experienced a minor adverse reaction - a pricking sensation in the face. No other adverse effects were noted. CONCLUSION: We conclude that drip infusion CTC with an infusion rate of the biliary contrast agent iotroxate governed by the serum bilirubin value is a feasible and safe alternative to MRC in patients with and without impaired biliary excretion. In this retrospective study the feasibility and the frequency of adverse reactions when using a drip infusion scheme based on bilirubin levels has been evaluated.

Journal Article↗

Standardized volume rendering for magnetic resonance angiography measurements in the abdominal aorta.

PURPOSE: To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets. MATERIAL AND METHODS: Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA. RESULTS: F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA). CONCLUSION: All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.

Analysis of Variance↗

Computed tomographic colonography: comparison of two workstations.

PURPOSE: To compare two commercially available computed tomography (CT) colonography systems with respect to interobserver variability, the influence of level of expertise, and the gradual reduction of reviewing time for each system. MATERIAL AND METHODS: Two residents and two radiologists using Siemens CTAPP Colography software and Viatronix V3D-Colon software reviewed supine and prone CT acquisitions from 24 patients in a primary 3D endoluminal view. The observers graded each case with respect to technical quality and diagnostic value, assessed the presence of pathology, and indicated the time spent on the viewing. RESULTS: Significant differences were found in technical quality (P < 0.001) and diagnostic value (P<0.001) depending on which system was used, with higher scores for the Viatronix software. The agreement between specialists tended to be higher than that between residents (kappa=0.63 (0.30-0.95) vs. kappa=0.51 (0.21-0.81)), and the residents gave significantly (P < 0.001) higher scores of technical quality. However, the level of expertise had no significant impact on the assessments. We noted extensive variability in pathological lesions found by the different observers. The number of findings did not differ between workstations, but the viewers tended to report larger polyp sizes with the Viatronix software. The time needed for viewing decreased significantly from the first to the last examination viewed by each observer. CONCLUSION: Both the evaluated systems present trustworthy images of the human colon, but in a primary 3D setting the Viatronix software is favored owing to the user-friendly interface, higher experienced technical quality, and better diagnostic value.

Adult↗

Standardized volume-rendering of contrast-enhanced renal magnetic resonance angiography.

PURPOSE: To propose a technique for standardizing volume-rendering technique (VRT) protocols and to compare this with maximum intensity projection (MIP) in regard to image quality and diagnostic confidence in stenosis diagnosis with magnetic resonance angiography (MRA). MATERIAL AND METHODS: Twenty patients were examined with MRA under suspicion of renal artery stenosis. Using the histogram function in the volume-rendering software, the 95th and 99th percentiles of the 3D data set were identified and used to define the VRT transfer function. Two radiologists assessed the stenosis pathology and image quality from rotational sequences of MIP and VRT images. RESULTS: Good overall agreement (mean kappa=0.72) was found between MIP and VRT diagnoses. The agreement between MIP and VRT was considerably better than that between observers (mean kappa=0.43). One of the observers judged VRT images as having higher image quality than MIP images. CONCLUSION: Presenting renal MRA images with VRT gave results in good agreement with MIP. With VRT protocols defined from the histogram of the image, the lack of an absolute gray scale in MRI need not be a major problem.

Adult↗

Volume rendering of three-dimensional drip infusion CT cholangiography in patients with suspected obstructive biliary disease: a retrospective study.

The purpose of this study was to evaluate the diagnostic potential of prolonged drip infusion CT cholangiography (DIC-CT) using meglumine iotroxate (Biliscopin) and 3D volume rendering in patients with suspected obstructive biliary disease. From a material of 142 patients who had undergone a drip infusion CT, all cases with a verified surgical or endoscopic retrograde cholangiography (ERC) diagnosis (n=33) were selected. Age-matched controls were selected from the remaining examinations. Three radiologists reviewed all 66 examinations in retrospect, independently as well as in consensus. The image quality and the estimated diagnostic quality were rated as good or moderate in 91% of the 198 reviews. The consensus sensitivity and specificity for diagnosing biliary stones was 88% and 94%, respectively (with sensitivities ranging from 88% to 94% for individual observers, and specificities from 86% to 96%). Two out of three strictures were observed. No false positive strictures were described. The use of volume rendering technique (VRT) improved diagnostic certainty in 28/198 (14%) of the evaluations. The visualization of ductal stones was improved in 18/48 (38%). No differences in diagnostic quality between single and multislice CT were observed. We conclude that a detailed image of the biliary tree with good sensitivity and specificity can be obtained by means of bilirubin-governed infusion time DIC-CT with volume rendering reconstruction.

Adult↗

Volume rendering compared with maximum intensity projection for magnetic resonance angiography measurements of the abdominal aorta.

PURPOSE: To compare the volume rendering technique (VRT) with maximum intensity projection (MIP) for aortic diameter measurements in MR angiography (MRA) data sets. MATERIAL AND METHODS: Existing contrast-enhanced 3-dimensional MRA and digital subtraction angiography (DSA) data sets from 20 patients were analyzed. In each MRA data set, two aortic diameters were measured using MIP and VRT. Agreement with DSA measurements, dependence on rendering parameters, and interobserver agreement were assessed. RESULTS: Diameters measured on MIP with fixed parameters showed no significant difference compared with DSA and with freely selected parameters a slight overestimation relative to DSA. Diameters measured on VRT were larger than on DSA. For both MIP and VRT, the measurements depended on the chosen parameters. The error relative to DSA was larger for VRT than for MIP with fixed parameters but not with freely chosen parameters. Interobserver agreement did not differ significantly. CONCLUSIONS: VRT is not suitable for diameter measurements of the abdominal aorta with fixed parameter settings but may be useful with user-selected settings.

Aged↗

Quantification of atherosclerosis with MRI and image processing in spontaneously hyperlipidemic rabbits.

The need for a quantitative method to assess atherosclerosis in vivo is well known. This study tested, in a familiar animal model of atherosclerosis, a combination of magnetic resonance imaging (MRI) and image processing. Six spontaneously hyperlipidemic (Watanabe) rabbits were examined with a knee coil in a 1.5-T clinical MRI scanner. Inflow angio (2DI) and proton density weighted (PDW) images were acquired to examine 10 cm of the aorta immediately cranial to the aortic bifurcation. Examination of the thoracic aorta was added in four animals. To identify the inner and outer boundary of the arterial wall, a dynamic contour algorithm (Gradient Vector Flow snakes) was applied to the 2DI and PDW images, respectively, after which the vessel wall area was calculated. The results were compared with histopathological measurements of intima and intima-media cross-sectional area. The correlation coefficient between wall area measurements with MRI snakes and intima-media area was 0.879 when computed individual-wise for abdominal aortas, 0.958 for thoracic aortas, and 0.834 when computed segment-wise. When the algorithm was applied to the PDW images only, somewhat lower correlations were obtained. The MRI yielded significantly higher values than histopathology, which excludes the adventitia. Magnetic resonance imaging, in combination with dynamic contours, may be a suitable technique for quantitative assessment of atherosclerosis in vivo. Using two sequences for the measurement seems to be superior to using a single sequence.

Algorithms↗

Allergic reactions at repeat femoral angiography with ioxaglate.

PURPOSE: To study the occurrence of allergy-like reactions at angiography, repeated several times, and, secondly, to evaluate the effect of prophylactic treatment in individuals who had earlier experienced such reactions. MATERIAL AND METHODS: One hundred and fifty-seven patients with hypercholesterolaemia, participating in the Probucol Quantitative Regression Swedish Trial (PQRST), underwent aortofemoral angiography with ioxaglate (Hexabrix) repeated annually for 3 years. Allergic reactions to the contrast medium were recorded. At the following angiographies, all patients who had earlier experienced such reactions were treated prophylactically with steroids and antihistamine. RESULTS: Allergic reactions were observed in 35 patients. Twelve reacted only year 0, 3 only year 1, 5 only year 2 and 6 only year 3. Eight patients had at least one reaction also when treated prophylactically. It was significantly (p<0.05) more common to react at year 0 but not at year 1 than to react at year 1 but not at year 0. At years 1, 2 and 3 the frequency of reactions was significantly greater in the group given prophylactic treatment than in the group without any earlier reaction at all: 8/20 versus 3/137, 4/23 versus 6/134, and 6/29 versus 6/128, respectively. CONCLUSION: Some individuals had an increased risk of an allergy-like reaction to the contrast agent. Prophylactic treatment reduced the risk of renewed reactions, but not to the same level as for those without earlier reaction. Nevertheless, individuals who have had earlier reactions can be investigated in the future, with prophylactic treatment.

Adult↗

MRI-guided celiac plexus block.

Celiac plexus block is used as a palliative procedure in cases of severe upper abdominal pain caused by pancreatitis or tumors of the pancreas. It can be guided by bony landmarks, fluoroscopy, ultrasound (US), or computed tomography (CT). To avoid severe complications, methods visualizing soft tissue, like CT and magnetic resonance (MR) imaging, are preferable. We describe celiac plexus blocks carried out in an open MR scanner, offering needle guidance with an optical tracking system and near real-time image acquisition. Eight patients with severe chronic abdominal pain were included. In these, 14 celiac blocks were carried out. Good or total pain relief was achieved in 8 of the 14 blocks (57%), a moderate effect in 5 blocks (36%), and no effect in 1 block (7%). The placement of the needle was easily guided with MR in all cases. The MR technique ensures good visualization of soft tissue, direct monitoring of needle movement and avoids exposure to ionizing radiation. Celiac plexus block can safely be carried out in an open MR scanner.

Abdominal Pain↗

Functional imaging of the thoracic outlet syndrome in an open MR scanner.

Symptoms due to thoracic outlet syndrome may present only in abduction, a position that cannot be investigated in conventional MR scanners. Therefore, this study was initiated to test MRI in an open magnet as a method for diagnosis of thoracic outlet syndrome. Ten volunteers and 7 patients with a clinical suspicion of thoracic outlet syndrome were investigated at 0.5 T in an open MR scanner. Sagittal 3D SPGR acquisitions were made in 0 and 90 degrees abduction. In the patients, a similar data set was also obtained in maximal abduction. To assess compression, the minimum distance between the first rib and the clavicle, measured in a sagittal plane, was determined. In the neutral position, no significant difference was found between patients and controls. In 90 degrees abduction, the patients had significantly smaller distance between rib and clavicle than the controls (14 vs 29 mm; p < 0.01). On coronal reformatted images, the compression of the brachial plexus could often be visualised in abduction. Functional MR examination seems to be a useful diagnostic tool in thoracic outlet syndrome. Examination in abduction, which is feasible in an open scanner, is essential for the diagnosis.

Adult↗

Gadolinium-enhanced magnetic resonance angiography, digital subtraction angiography and duplex of the iliac arteries compared with intra-arterial pressure gradient measurements.

PURPOSE: to compare gadolinium-enhanced magnetic resonance angiography (Gd-MRA), digital subtraction angiography (DSA) and duplex of the iliac arteries with intra-arterial pressure gradient measurement as the reference method. MATERIALS AND METHODS: Gd-MRA, DSA and duplex examinations of the iliac arteries were performed in 30 patients (60 arteries) with lower-limb arterial occlusive disease. In 29 arteries, pressure measurements were made (n=25) or the artery was found to be occluded on catheterisation (n=4). An aortofemoral peak systolic pressure gradient of 20 mmHg or more was regarded as haemodynamically significant. Stenoses with a diameter reduction of 50% or more on MRA or DSA, or an increase in peak systolic velocity greater than 150% (duplex) were considered significant. MRA examinations were evaluated by means of maximum intensity projections (MRA-MIP) and using source images and curved multiplanar reconstruction (MRA-MPR). RESULTS: the sensitivity (specificity) for a significant iliac artery stenosis were 81% (75%) for MRA-MIP, 76% (75%) for MRA-MPR, 86% (88%) for DSA, and 72% (88%) for duplex. CONCLUSION: with intra-arterial pressure measurements as the reference method, similar results were achieved with Gd-MRA, DSA and duplex concerning the detection of haemodynamically significant iliac artery stenoses. The use of source images and multiplanar reconstructions resulted in higher accuracy for the detection of occlusions.

Aged↗

Characterization of human head vasculature by percolation parameters.

A data reduction procedure, originally proposed for characterization of fractals and random percolation clusters, has been used to evaluate the vascular system of the human head. The motivation behind this study arose from the wish to study empirically transport properties of vascular systems and to find a suitable formalism for their description. MR angiographic data acquired by a standard 3D inflow method were used. The evaluated parameters refer to the backbone fractal dimensionality and the correlation length. The fractal dimensionality of the backbone was found to be 1.71 for the human head vasculature. This value fits the theoretical range of random percolation networks. It is concluded that concepts of percolation theory might have some value for characterizing the structure and transport properties of the vascular system.

Brain↗

Quantitation of atherosclerosis by magnetic resonance imaging and 3-D morphology operators.

The objective was to ascertain whether MRI and image processing can be used to quantify atherosclerosis by measuring wall thickness in rabbit aorta. The abdominal aortas of 2 healthy and 5 atherosclerotic rabbits were examined with a gradient-echo inflow angiography sequence (2DI) and a proton density weighted turbo-spin-echo sequence (PDW). Using thresholding by four observers and 3D morphology operators, segmentation of the artery and vein lumina was performed from the 2DI sequence, and of surrounding fat and muscle from the PDW sequence. Remaining voxels adjacent to the aortic lumen were classified as vessel wall. By measuring the vessel wall volume and the lumen volume, the wall percentage was calculated. The values were significantly higher for the diseased animals than for unaffected individuals (p < 0.01). It is concluded that aortic wall thickening in atherosclerotic rabbits can be measured quantitatively by using MRI combined with 3D morphology image processing operators.

Animals↗

Timing adjustment in gadolinium MR angiography by raw data recombination. Technical note.

To solve the problem of injection timing in gadolinium MR angiography, a simple procedure is proposed which allows the acquisition interval to be chosen after injection. Starting simultaneously with the injection, several consecutive acquisitions are made, after which raw data acquired in a contiguous interval with a variable starting time are recombined to one data set, which is then used for delayed image reconstruction.

Aged↗

2D inflow MR angiography in severe chronic leg ischemia.

PURPOSE: The aim of this study was to compare 2D inflow MR angiography (MRA) with selective X-ray angiography (XRA) in patients with severe chronic leg ischemia. MATERIAL AND METHODS: In a blinded prospective study, 2D inflow MRA and XRA were compared with regard to evaluation of the arteries distal to the knee in 24 patients (median age 72 years) with severe ischemia; 23 of them had either rest pain or tissue loss. Statistics were calculated with XRA as the reference method. RESULTS: The interpretations of 2D inflow MRA and XRA showed moderate agreement in the calf arteries but poor agreement in the foot arteries. Of the discrepancies, two-thirds were observer-related and only one-third method-related. Of all the comparable arteries, 9% showed method-related differences between the two methods. An assessment of MRA using only maximum intensity projections (MIP) resulted in 19% of findings being judged inconclusive whereas all the arteries could be classified when the cross-sectional images were studied on the viewing console. CONCLUSION: The agreement between MRA and XRA was good in the calf but questionable in the foot.

Adult↗

Magnetic resonance angiography in the resectability assessment of suspected pancreatic tumours.

The aim of this prospective study was to evaluate MRI, including MR angiography (MRA), in the preoperative assessment of the resectability of suspected malignancy of the pancreas. A total of 17 patients with suspected pancreatic carcinoma and planned surgery were investigated with conventional angiography, ultrasonography with Doppler technique, MRI and MRA. The MRA protocol included both 2D inflow angiography and 3D phase-contrast angiography. Surgery was carried out in 13 patients. The image quality of MRA was judged satisfactory in all cases. The findings with respect to vascular involvement agreed between the radiological methods in all but 3 cases. When the findings were correlated with the final diagnosis, one false-negative case was found for each of the three methods. The results suggest that MRI with MRA, including both the phase-contrast and inflow techniques, has a similar diagnostic value to that of conventional angiography and ultrasonography in the preoperative assessment of the portal venous system in patients with pancreatic carcinoma. Further studies are needed to establish the optimal diagnostic procedure.

Biopsy↗

Do plaques grow upstream or downstream?: an angiographic study in the femoral artery.

Although the distribution of atherosclerosis has been described, little is known about the direction of growth of plaques. In this study, 237 patients with slight or moderate atherosclerosis underwent femoral angiography twice at a 3-year interval, and the films were studied with computerized image analysis. First, atherosclerosis was measured as edge roughness, and the change in roughness of each 1-cm segment over the 3-year period was related to the edge roughness of the segments immediately upstream and downstream. On the medial side of the artery, the change in edge roughness was found to be more strongly related to the roughness values upstream than to those downstream of the segment studied. This suggests that growth in the downstream direction is more common than growth in the upstream direction. On the lateral side, more equivocal results were obtained. Atherosclerosis was also assessed by study of the cross-sectional area of the artery as a function of distance along the vessel. A mathematical model of plaque growth was formulated as a nonlinear filtering of this curve. Growth in the downstream direction was significantly (P<.001) more frequent than growth in the upstream direction. The findings are compatible with an atherogenic effect of fluid mechanical disturbances, such as flow separation, that may occur downstream of a stenosis.

Adult↗

Development of femoral atherosclerosis in relation to flow disturbances.

Angiography and post-mortem studies have indicated that disturbed blood flow may promote atherogenesis. Our aim was to demonstrate flow disturbances in vivo and correlate them to the subsequent development of atherosclerosis. The femoral arteries of 17 patients with early atherosclerosis were studied with cineangiography. The films are digitized and analyzed with an image analysis computer. From the time-intensity curves, the arrival time of the contrast medium at each pixel was calculated. In the resulting parametric images, the computer identified zones of delayed contrast filling, (ZDF) which have been shown to correspond to disturbed flow. The progression or regression of atherosclerosis was followed with another angiography 3 years later by computing changes in edge roughness. Arterial segments without flow disturbances (defined as ZDF) showed a more marked decrease in edge roughness than those with flow disturbances (p < 0.05). In addition, the edge roughness tended to increase more in segments with larger ZDF area. Angiographic studies of fluid mechanics and atherogenesis are feasible, but larger patient materials are needed.

Adult↗