Search PubMed⌕ Search

Biomedical subjects

O R Hung

Publications and source records attributed to O R Hung.

30 records · Page 2Linked to original sources

Lightwand intubation: I--a new lightwand device.

Tracheal intubation under direct vision using a laryngoscope can be challenging and difficult even in experienced hands. Transillumination of the soft tissues of the neck using a lighted-stylet (lightwand) is one of many effective alternative intubating techniques developed during the past several decades. While many versions of lightwand have been available, each has its limitations. A newly developed lightwand (Trachlight) has incorporated many design modifications. It has a brighter bulb, permitting intubation under ambient light in most cases. A retractable stiff wire within the wand adds flexibility to facilitate both oral and nasal intubation. The flexible wand also allows visual (transillumination) guide to proper placement of the tip of the tracheal tube in the trachea. The Trachlight does have some limitations. It is a light-guided technique in which there is no direct visualization of the upper airway structures. It should be avoided in patients with known anatomical abnormalities of the upper airway and used with caution in patients in whom transillumination of the anterior neck may not be achieved adequately. As with any intubating technique, successful intubation using the Trachlight relies on the preparation of the patient and the operator's skill and experience.

Humans↗

Lightwand intubation: II--Clinical trial of a new lightwand for tracheal intubation in patients with difficult airways.

Lightwands have been used to assist in the tracheal intubation of patients with difficult airways for many years. A new lightwand (Trachlight) with a brighter light source and a flexible stylet permits both oral and nasal intubation under ambient light. This study reports the effectiveness of the Trachlight in tracheal intubation in patients with difficult airways. Two groups of patients were studied: Group 1--patients with a documented history of difficult intubation or anticipated difficult airways; Group 2--anaesthetized patients with an unanticipated failed laryngoscopic intubation. In Group 1, the tracheas were intubated using the Trachlight with patients either awake or under general anaesthesia. In Group 2, tracheas were intubated under general anaesthesia using the Trachlight. The time-to-intubation, number of attempts, failures, and complications during intubation for all patients were recorded. Two hundred and sixty-five patients were studied with 206 patients in Group 1, and 59 in Group 2. In most patients, the tracheas were intubated orally (183 versus 23 nasal) during general anaesthesia (202 versus 4 awake) in Group 1. Intubation was successful in all but two of the patients with a mean (+/- SD) time-to-intubation of 25.7 +/- 20.1 sec (range 4 to 120 sec). The tracheas of these two patients were intubated successfully using a fibreoptic bronchoscope. Orotracheal intubation was successful in all patients in Group 2 using the Trachlight with a mean (+/- SD) time-to-intubation of 19.7 +/- 13.5 sec. Apart from minor mucosal bleeding (mostly from nasal intubation), no serious complications were observed in any of the study patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Pharmacokinetics of inhaled liposome-encapsulated fentanyl.

BACKGROUND: Pulmonary administration of fentanyl solution can provide satisfactory but brief postoperative pain relief. Liposomes are microscopic phospholipid vesicles that can entrap drug molecules. Liposomal delivery of fentanyl has the potential to control the uptake of fentanyl by the lungs and thus provide sustained drug release. To demonstrate that inhalation of a mixture of free and liposome-encapsulated fentanyl can provide a rapid increase and sustained plasma fentanyl concentrations (CfenS), this study determined the pharmacokinetic profiles after the inhalation of free and liposome-encapsulated fentanyl in healthy volunteers. METHODS: After obtaining institutional approval and informed consent, ten healthy volunteers (five men, five women) were studied. Each subject received 200 micrograms intravenous fentanyl and inhaled 2,000 micrograms of free (50%) and liposome-encapsulated fentanyl (50%) on separate occasions. Frequent venous blood samples were collected, and CfenS were determined by radioimmunoassay. The pharmacokinetics and absorption characteristics of the inhaled mixture of free and liposome-encapsulated fentanyl were determined using moment analysis and least-squares numeric deconvolution. RESULTS: The mean (+/- SD) volume of distribution at steady-state and clearance of fentanyl after the intravenous administration were comparable to previous studies: 435 +/- 1821 and 0.584 +/- 0.209 l.min-1, respectively. The mean (+/- SD) peak Cfen was significantly greater for the intravenous administration compared to the aerosol mixture of free and liposome-encapsulated fentanyl (4.67 +/- 1.87 vs. 1.15 +/- 0.36 ng.ml-1). However, CfenS at 8 and 24 h after aerosol administration were greater compared to intravenous (0.25 +/- 0.14 and 0.12 +/- 0.16 ng.ml-1 for aerosol versus 0.16 +/- 0.10 and 0.05 +/- 0.06 ng.ml-1 for intravenous). The peak absorption rate, time to peak absorption, and bioavailability after inhalation were 7.02 (+/- 2.34) micrograms.min, -1(16) (+/- 8.0) min, and 0.12 (+/- 0.11), respectively. CONCLUSIONS: The data suggest that this analgesic method offers a simple and noninvasive route of administration with a rapid increase of Cfen and a prolonged therapeutic fentanyl concentration. Future studies are required to determine the optimal liposome composition that would produce a sustained stable Cfen within analgesic therapeutic concentrations.

Adult↗

Clinical trial of a new lightwand device (Trachlight) to intubate the trachea.

BACKGROUND: Transillumination of the soft tissue of the neck using a lighted stylet (lightwand) is an effective and safe intubating technique. A newly designed lightwand (Trachlight) incorporates modifications to improve the brightness of the light source as well as flexibility. The goal of this study was to determine the effectiveness and safety of this device in intubating the trachea of elective surgical patients. METHODS: Healthy surgical patients were studied. Patients with known or potential problems with intubation were excluded. During general anesthesia, the tracheas were intubated randomly using either the Trachlight or the laryngoscope. Failure to intubate was defined as lack of successful intubation after three attempts. The duration of each attempt was recorded as the time from insertion of the device into the oropharynx to the time of its removal. The total time to intubation (TTI), an overall measure of the ease of intubation, was defined as the sum of the durations of all (as many as three) intubation attempts. Complications, such as mucosal bleeding, lacerations, dental injury, and sore throat, were recorded. RESULTS: Nine hundred fifty patients (479 in the Trachlight group and 471 in the laryngoscope group) were studied. There was a 1% failure rate with the Trachlight, and 92% of intubations were successful on the first attempt, compared with a 3% failure rate and an 89% success rate on the first attempt with the laryngoscope (P not significant). All failures were followed by successful intubation using the alternate device. The TTI was significantly less with the Trachlight compared with the laryngoscope (15.7 +/- 10.8 vs. 19.6 +/- 23.7 s). For laryngoscopic intubation, the TTI was longer for patients with limited mandibular protrusion and mentohyoid distance, with a larger circumference of the neck, and with a high classification according to Mallampatti et al. However, there was no relation between the TTI and any of the airway parameters for Trachlight. There were significantly fewer traumatic events in the Trachlight group than in the laryngoscope group (10 vs. 37). More patients complained of sore throat in the laryngoscope group than in the Trachlight group (25.3% vs. 17.1%). CONCLUSIONS: In contrast to laryngoscopy, the ease of intubation using the Trachlight does not appear to be influenced by anatomic variations of the upper airway. Intubation occasionally failed with the Trachlight but in all cases was resolved with direct laryngoscopy. The failures of direct laryngoscopy were resolved with Trachlight. Thus the combined technique was 100% successful in intubating the tracheas of all patients.

Adult↗

Drug allergies in the surgical population.

Many patients claim to have drug allergies. However, the signs and symptoms of "allergic reactions" are seldom documented and the drug allergies are rarely properly assessed. The goal of this study was to determine the incidence of claimed "drug allergies" in a surgical population. After obtaining institutional approval, the study was carried out at five hospitals affiliated with Dalhousie University. Patients were interviewed by the investigators during the preoperative anaesthetic evaluation over six months and all signs and symptoms of drug reactions were recorded. The validity of the claimed allergy was based on the history. The allergies were assigned to one of three groups: (1) High probability of an allergic reaction: one or more of the signs and symptoms typical of an immunological reaction, with or without a family history, or a history of atopy; (ii) Low probability of an allergic reaction: signs and symptoms of the reaction were predictable reactions or side effects of the drug, without the occurrence of reactions mentioned above; or (iii) Unknown status: no information concerning the reaction of history was available. Of 1818 adult and paediatric patients (914 female/904 male) interviewed, 511 (28.1%) claimed to have one or more drug allergies (a total of 671 allergies). More women than men claimed to have drug allergies (60.3% vs 39.7%) and there was a positive correlation between age, number of medications and reported drug allergies. Antibiotics (50%), opioids (27%), non-steroidal anti-inflammatory agents (10%), and sedatives (5%) accounted for 92% of all claimed drug allergies. Overall, 50% of claimed allergies had a high probability of true allergic reactions.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Thiopental pharmacodynamics. I. Defining the pseudo-steady-state serum concentration-EEG effect relationship.

To assess depth of anesthesia for intravenous anesthetics using clinical stimuli and observed responses, it is necessary to achieve constant serum concentrations of drug that result in constant biophase or central nervous system concentrations. The goal of this investigation was to use a computer-controlled infusion pump (CCIP) to obtain constant serum thiopental concentrations and use the electroencephalogram (EEG) as a measure of thiopental's central nervous system drug effect. The number of waves per second obtained from aperiodic waveform analysis was used as the EEG measure. A CCIP was used in six male volunteers to attain rapidly and then maintain for 6-min time periods the following pseudo-steady-state constant serum thiopental target concentrations: 10, 20, 30, and 40 micrograms/ml. The median performance error (bias) of the CCIP using 149 measurements of thiopental serum concentrations in six subjects was +5%, and the median absolute performance error (accuracy) was 16%. Following the step change in serum thiopental concentration, the EEG number of waves per second stabilized within 2-3 min and the remained constant until the target serum thiopental concentration was changed. When the constant serum thiopental concentration was plotted against the number of waves per second for each subject, a biphasic serum concentration versus EEG effect relationship was seen. This biphasic concentration:response relationship was characterized with a nonparametric pharmacodynamic model. The awake, baseline EEG was 10.6 waves/s; at peak activation the EEG was 19.1 waves/s and occurred at a serum thiopental concentration of 13.3 micrograms/ml. At a serum thiopental concentration of 31.2 micrograms/ml the EEG had slowed to 10.6 waves/s (back to baseline) and at 41.2 micrograms/ml was 50% below the baseline, awake value. Zero waves per second occurred at serum thiopental concentrations greater than 50 micrograms/ml. Using a CCIP it is possible to establish constant serum thiopental concentration rapidly and characterize the concentration versus EEG drug effect relationship.

Adult↗

Thiopental pharmacodynamics. II. Quantitation of clinical and electroencephalographic depth of anesthesia.

This study examined the relationship among pseudo-steady-state (constant) serum thiopental concentrations, clinical anesthetic depth as assessed by several perioperative stimuli, and the electroencephalogram (EEG). Twenty-six ASA physical status 1 or 2 patients participated in the study. Two constant serum thiopental concentrations were maintained in each patient using a computer-controlled infusion pump. The first randomly assigned target serum concentration of 10-30 micrograms/ml was maintained for 5 min to allow serum:brain equilibration. Then the following stimuli were applied at 1-min intervals: verbal command, tetanic nerve stimulation, trapezius muscle squeeze, and laryngoscopy. A second, higher, randomly assigned target serum concentration of 40-90 micrograms/ml was then achieved and maintained by the computer-controlled infusion pump. The previously described stimuli were reapplied, after which laryngoscopy and intubation was performed. A positive response was recorded if purposeful extremity movement or coughing was observed. Using the quantal movement or cough response and the measured constant serum thiopental concentration, the probability of no movement to each stimulus was characterized using logistic regression. The serum thiopental concentrations that produced a 50% probability of no movement response for the clinical stimuli were as follows: 15.6 micrograms/ml for verbal command, 30.3 micrograms/ml for tetanic nerve stimulation, 39.8 micrograms/ml for trapezius muscle squeeze, 50.7 micrograms/ml for laryngoscopy, and 78.8 micrograms/ml for laryngoscopy followed by intubation. The EEG was analyzed using aperiodic waveform analysis to derive the number of waves per second. A biphasic relationship between constant serum thiopental concentration and the EEG number of waves per second was observed. Loss of responsiveness to verbal stimulation occurred when the EEG was activated at 15-18 waves/s.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Depression of theophylline elimination following BCG vaccination.

This study investigated the effects of BCG vaccination on the elimination of a single dose of theophylline in twelve healthy female volunteers. Two weeks following BCG vaccination the mean serum theophylline half-life was increased significantly in subjects with a positive Mantoux test compared to the mean half-life determined prior to vaccination. The mean volume of distribution for theophylline was unchanged following vaccination. In two subjects with negative Mantoux tests theophylline half-life was unchanged after vaccination. It is therefore suggested that immunostimulation following BCG vaccination may impair the capacity of the liver to eliminate theophylline.

Adolescent↗

Depression of theophylline elimination by erythromycin.

The elimination of a single oral dose of theophylline was studied in 12 healthy subjects before and after 250 mg erythromycin every 8 hr for 10 days. Serum theophylline elimination half-life rose from 4.79 +/- 0.43 hr before to 7.53 +/- 0.71 hr after erythromycin. Theophylline clearance decreased from a mean of 91.6 +/- 27.0 to 54.8 +/- 10.0 ml/kg/hr after erythromycin and the mean apparent volumes of distribution were much the same before and after the antibiotic. The excretion of theophylline and its metabolites was studied in the urine of three of the subjects. In each case the amount of 3-methylxanthine and 1,3-dimethyluric acid decreased after antibiotic. Adjustments of the theophylline dosage may be necessary for patients who take theophylline and erythromycin concurrently to minimize the risk of theophylline toxicity.

Administration, Oral↗