Search PubMed⌕ Search

Biomedical subjects

O Otsubo

Publications and source records attributed to O Otsubo.

At least 37 records · Page 2Linked to original sources

Changes of enzyme activity levels in red blood cells in hemodialysis patients by recombinant human erythropoietin.

In a phase II clinical trial to test the ability of recombinant human erythropoietin (r-HuEPO) to reverse the anemia of patients undergoing hemodialysis, the changes of enzyme activity in red blood cells were evaluated in 5 hemodialysis anemic patients who were treated with r-HuEPO. Concerning the activity levels measured, the following conclusions are drawn. 1) HK, ALD, TPI, G6PD and 6PGD were statistically significantly increased at the time when the hematocrit has risen by 8% with the use of r-HuEPO. 2) The enzyme activity levels of PFK, GA3PD, MPGM, ENOL, PK, GR and ADA were higher than normal already before the r-HuEPO treatment. 3) The increases of HK and G6PD by r-HuEPO, as age dependent enzymes, may reflect the generation of young red blood cells. 4) In view of the fact that they are related to ATP production in the glycolysis cycle, we infer that increases of red blood cell enzymes by r-HuEPO may play at least some part in bringing a sensation of "well-being" to severely anemic patients undergoing hemodialysis.

Adenosine Triphosphate↗

Endoscopic management of shoulder pain in long-term haemodialysis patients.

In 48 shoulders of 29 patients receiving long-term haemodialysis and complaining of intolerable shoulder pain, endoscopic resection of the coracoacromial ligament was performed under local anaesthesia on an outpatient basis, using the Universal Subcutaneous Endoscope system. Predominant endoscopic findings were proliferation of the subacromial bursae and popping between the coracoacromial ligament and the rotator cuff. Amyloid originating from beta 2 microglobulin (beta 2-M) was demonstrated in 87% of the resected coracoacromial ligaments and 86% of the subacromial bursae. Resection of the coracoacromial ligament relieved the shoulder pain in all patients.

Adult↗

Clinical application of Fragmin (FR-860) in hemodialysis: multicenter cooperative study in Japan.

A multicenter cooperative study was designed to evaluate the efficacy and safety of Fragmin (FR-860) as an anticoagulant in hemodialysis. Sixty-one stable maintenance hemodialysis patients were enrolled from 14 institutions in Japan. The study period was fixed at 2 weeks. Dosage requirements were 15.0 to 20.0 anti-Xa U/kg as bolus and 7.5 to 10.0 anti-Xa U/kg/hr as continuous infusion. The total dosage of Fragmin was 2505 +/- 127 anti-Xa U compared with 6124 +/- 190 U of conventional heparin. No differences were observed in residual blood in extracorporeal circuits between the groups. The hemostasis times at puncture sites after completion of dialysis were significantly shortened in the Fragmin group (7.9 +/- 0.7 minutes) when compared with the conventional heparin group (11.4 +/- 1.1 minutes; p less than 0.01). Plasma anti-Xa levels were 0.24 +/- 0.03 and 0.36 +/- 0.04 U/ml 1 hour after the initiation and at the completion of dialysis, respectively. ACTs, measured by the Hemochron method, were not prolonged during dialysis. APTTs varied from 34.3 +/- 1.2 before dialysis to 41.0 +/- 1.9 (p less than 0.01) 1 hour after the start of dialysis and 39.9 +/- 1.6 seconds (p less than 0.01) at the end of dialysis. Plasma AT III activity increased from 96.8 +/- 2.5% before dialysis to 113.0 +/- 3.2% (p less than 0.01) at the end of dialysis. No significant changes were observed in both ADP- and collagen-induced platelet aggregation during dialysis. Dialysis efficiency was the same for both groups. Slight itching developed in one of 61 cases. No abnormal laboratory data were observed during the study. The efficacy, safety, and utility rates were 98.4, 98.5, and 98.4%, respectively. Fragmin proved to have a higher utility rate and was a good and convenient alternative to conventional heparin as an anticoagulant in hemodialysis treatment.

Antithrombin III↗

[Clinical studies on 228 renal transplants].

We studied patient survival and graft survival rates by dividing 228 renal transplants into seven groups according to their immunosuppressive regimen and the degree of histocompatibility. Both patient survival and graft survival rates of HLA identical sibling (Id Sib), living related transplantation with cyclosporin (CYA), transplantation with donor-specific transfusion and anti-lymphocyte globulin (DST.ALG) and cadaveric transplantation with cyclosporin (CYA.Cad) groups were better than those of living related transplantation with ALG, without DST (ALG), living related transplantation with azathioprine and steroid (Non-DST.Non-ALG) and cadaveric transplantation without cyclosporin (Conv.Cad) groups. The incidence and severity of acute rejection were lower in Id Sib, CYA, DST.ALG and CYA.Cad groups than in other groups. The incidence of infections was the highest in Conv.Cad group and that of fatal infections was higher in ALG, Non-DST.Non-ALG and Conv.Cad groups than in other groups. These results indicated that acute rejection and infection were two important factor that influenced the survival rates of these patients. Up to now, the graft survival rate of CYA.Cad group has been much improved as compared to that of Conv.Cad group and was better than those of ALG and Non-DST.Non-ALG groups. The fact urges us to promote more cadaveric renal transplantation in our country by virtue of ciclosporin.

Adult↗

Clinical effect of recombinant human erythropoietin on anemia associated with chronic renal failure. A multi-institutional study in Japan.

Clinical effect and safety of recombinant human erythropoietin (r-HuEPO) were evaluated in 66 hemodialysis patients with intractable anemia. Initially, 50U/kg dry weight (DW) of r-HuEPO was administered intravenously at the end of every hemodialysis procedure for 4 weeks, then the dosage was increased to 100 and 200U/kg DW for poor responders. The patients' hematocrits rose from 19.8 +/- 2.3% (pretreatment) to 30.2 +/- 4.9% after 12 weeks. From 206 U of blood transfusion requirement in the 3-month period before the study, only 34 U were needed after treatment. Serum iron and ferritin levels fell significantly during the study, and iron storage was considered to be one of the decisive factors in the response to r-HuEPO. Blood pressure rose in the course of r-HuEPO administration, but uncontrollable hypertension was rarely observed. There was no significant adverse effect of r-HuEPO except for this mild hypertension. These results indicate that r-HuEPO is an excellent therapeutic aid for the anemia associated with chronic renal failure.

Adult↗

Multi-component analysis of urine of dogs with liver diseases by high-performance liquid chromatography.

Components of the urine of normal dogs and dogs with liver diseases were analysed by high-performance liquid chromatography (HPLC) using a macroreticular anion-exchange resin with UV detection. The dogs with liver diseases were experimentally prepared by either Eck fistula by portal-caval anastomosis, dimethylnitrosamine-induced liver failure or total hepatectomy by operation. Eighteen chromatographic peaks were numbered and the cross-correlation coefficient of the intensities of every pair of peaks was computed. There were high correlations between several pairs of peaks according to the types and degrees of the hepatic failures, whereas no significant correlation was observed for the peak pairs of normal urine samples. The results showed that HPLC analysis of urine is useful in the diagnosis of the physiological state in liver dysfunction.

Animals↗

A new method for early detection of renal allograft rejection. Gel high-performance chromatography of urinary IgM.

We developed a new device utilizing high-performance chromatography to measure urinary IgM protein in renal transplant recipients. With this device we were able to obtain a reliable result in less than 2 h, requiring much less time than using the conventional method. Urinary IgM was found in 22 of 23 posttransplantation patients (96%) during acute rejection. An increase in urinary IgM excretion was noted 2-3 days before the appearance of clinical signs of acute rejection.

Adult↗

Acute changes in C3a and C5a in an anaphylactoid reaction in hemodialysis patients.

Blood sample were collected from both the arterial and venous lines of the patients undergoing hemodialysis using cuprophan membrane at several time intervals. Radioimmunoassay was then applied to measure the C3a and C5a levels. C3a levels from the arterial lines of patients undergoing uneventful hemodialysis were 463.2 +/- 51.3 ng/ml (mean +/- S.D.), 1112.9 +/- 109.9, 956.0 +/- 72.1, and 721.2 +/- 49.6 at 0, 15, 120 and 360 min, respectively. C5a levels did not change significantly during uneventful hemodialysis. C3a and C5a levels were significantly higher in the blood from the venous lines than those from the arterial lines, a finding indicating that complement activation via alternative pathway takes place in the dialyzer. C3a and C5a levels were markedly elevated in patients with anaphylactoid reaction. Reuses of dialyzers on the patients having a history of an anaphylactoid reaction during hemodialysis suppressed not only the rise of C3a levels, but also the recurrence of the reaction. From these findings, it is concluded that rises of C3a and C5a in the arterial lines of patients are causally related to the induction of anaphylactoid reaction during hemodialysis.

Anaphylaxis↗

Silicone as coating material for hemoperfusion.

The effectiveness of activated charcoal in direct hemoperfusion (DHP) has been recognized, but there are still problems with a decrease in solid components of blood and of dimishing adsorption capacity by coating layers on the surface of the sorbents in DHP. In the present study, we have developed activated charcoal derived from thermosetting resin, coated with silicone, and have observed changes in blood components after a 3 hr DHP. Adsorption capacity of the activated charcoal was determined in vitro, and was compared with noncoated charcoal and poly(hydroxyethyl methacrylate) (PHEMA) coated charcoal. Reduction in leukocyte and platelet counts was less with the silicone coated and PHEMA coated charcoals than with the noncoated charcoal. Variations in leukocyte counts and platelet counts were less in DHP with silicone-coated charcoal than with the others. Adsorption of the solid components of blood on the silicone-coated charcoal, examined by scanning electron microscopy after DHP, was very slight, showing its excellent applicability to DHP therapy. The degree of adsorption of various amino acids and related compounds on the silicone-coated charcoal was comparable to that on the noncoated charcoal. Thus, there seems only slight reduction in the degree of adsorption on the silicone-coated charcoal.

Adsorption↗