Search PubMed⌕ Search

Biomedical subjects

O Lund

Publications and source records attributed to O Lund.

At least 19 recordsLinked to original sources

[Coronary artery bypass without use of the heart-lung-machine].

INTRODUCTION: Off pump coronary artery bypass via sternotomy (OPCAB) and via a small left anterior thoracotomy (MIDCAB) on the anterior coronary arteries of the heart was introduced at the present center in 1997. Starting this year we decided to increase OPCAB and MIDCAB to constitute at least 50% of CAB procedures including the posterior aspect of the heart. METHODS: From January 1st through April 16th 1999 we performed 152 CAB procedures: 108 CABG, 6 MIDCAB, 13 OPCAB (on the anterior cornary arteries) and 25 OPCAB-Cx (including the circumflex artery). OP procedures were done using OCTOPUS-II to expose and stabilize the arteriotomies, and control angiography was performed before discharge. RESULTS: Off pump CAB was performed in 2% of the first 50 CAB patients, 36% of the next 50 and 50% of the last 52. The CABG and OPCAB-Cx groups were comparable as regards degree of coronary artery disease and number of distal anastomoses, but differed as regards poor left ventricular function and unstable preoperative status. Early mortality was 1.9% in the CABG group and 0% in the OP groups. Control angiograms in the OP groups showed a patency from 92 to 100%. CONCLUSIONS: In this short preliminary series, it was possible to increase the fraction of OP procedures to nearly 50% with good results.

Adult↗

Prediction of protein secondary structure at 80% accuracy.

Secondary structure prediction involving up to 800 neural network predictions has been developed, by use of novel methods such as output expansion and a unique balloting procedure. An overall performance of 77.2%-80.2% (77.9%-80.6% mean per-chain) for three-state (helix, strand, coil) prediction was obtained when evaluated on a commonly used set of 126 protein chains. The method uses profiles made by position-specific scoring matrices as input, while at the output level it predicts on three consecutive residues simultaneously. The predictions arise from tenfold, cross validated training and testing of 1032 protein sequences, using a scheme with primary structure neural networks followed by structure filtering neural networks. With respect to blind prediction, this work is preliminary and awaits evaluation by CASP4.

Neural Networks, Computer↗

Mutational spectrum in the cardioauditory syndrome of Jervell and Lange-Nielsen.

Jervell and Lange-Nielsen syndrome (JLNS) is an autosomal recessive syndrome characterised by profound congenital sensorineural deafness and prolongation of the QT interval on the electrocardiogram, representing abnormal ventricular repolarisation. In a study of ten British and Norwegian families with JLNS, we have identified all of the mutations in the KCNQ1 gene, including two that are novel. Of the nine mutations identified in this group of 10 families, five are nonsense or frameshift mutations. Truncation of the protein proximal to the recently identified C-terminal assembly domain is expected to preclude assembly of KCNQ1 monomers into tetramers and explains the recessive inheritance of JLNS. However, study of a frameshift mutation, with a dominant effect phenotypically, suggests the presence of another assembly domain nearer to the N-terminus.

Amino Acid Substitution↗

Standard aortic St. Jude valve at 18 years: performance profile and determinants of outcome.

BACKGROUND: The standard St. Jude disc valve has been in use for 20 years and remains the dominant mechanical valve of today. With nearly 19 years of follow-up, the present large series could indicate the performance profile and its determinants in the very long term. METHODS: A detailed follow-up was performed to a maximum of 18.6 years in 694 patients aged 15 to 83 years who undervent aortic valve replacement (AVR) with the standard St. Jude valve during 1980 to 1993. The Cox regression analysis was used to identify independent determinants of outcome in the aortic stenosis (n = 490) and regurgitation (n = 204) groups. RESULTS: Overall survival was 58%, 39%, and 37% at 10, 15, and 18 years, respectively. Only 12% of deaths (0.60%/ patient-year) were related to the valve with a 15-year freedom of 91%. Embolism (1.18%/patient-year) and anticoagulant-related bleeding (2.24%/patient-year) were the dominant complications with 10-year/15-year freedoms of 90%/80% and 85%/72%, respectively. Only 24% of bleeding events were classified as major. Valve thrombosis occurred in 2 patients (0.04%/patient-year): 1 did not receive vitamin K antagonist treatment and International Normalized Ratio was below target level in the other. There were no mechanical failures. Endocarditis (0.42%/patient-year) and paravalvular leak (0.42%/ patient-year) occurred with 15-year freedoms of 92% and 96%, respectively, with a relation between the latter (but not the former) and preoperative endocarditis in the regurgitation group. Freedom from serious complications (2.33%/patient-year) and all complications joined (4.33%/ patient-year) were 72% and 54%, respectively, at 15 years with a 96% freedom from redo AVR (0.36%/patient-year). Age- and heart-related variables were independent risk factors for mortality, thromboembolism, bleeding, serious complications, and all complications joined. Small valve (19 and 21 mm) adversely affected serious and all complications in the regurgitation group. CONCLUSIONS: With a follow-up approaching 2 decades and exhibiting a low rate of valve-related deaths, acceptable low thrombogenicity, and absence of mechanical failure, the standard aortic St. Jude disc valve sets the standard for contemporary mechanical valves.

Adolescent↗

Long-term results after aortic valve replacement in patients with congestive heart failure. Homografts vs prosthetic valves.

OBJECTIVES: The aim of this study was to assess the influence of valve substitute (homograft vs prosthetic valve) on the long-term survival and late valve-related complication rates following aortic valve replacement in patients with aortic valve disease and congestive heart failure. BACKGROUND: The effect of choice of valve substitute on outcome after aortic valve replacement in patients with pre-operative heart failure is unknown. The superior haemodynamic profile of homografts may be of particular benefit. METHODS: We retrospectively analysed pre-operative, operative and follow-up data on 518 adults in functional classes III and IV, who, over the 25 years 1969-1993, had their initial aortic valve replacement at Harefield hospital. Follow-up conducted during 1996 to April 1997 and totalling 4439 patient-years was 96.1% complete. Using multivariate analysis, independent risk factors for different complications and mortality were defined. RESULTS: Overall 5-, 10- and 20-year survival was 80+/-2%, 62+/-2% and 30+/-3%, respectively, with no significant difference between valve types. However, homografts (n=381) independently reduced the rate of serious complications and cardiac death, whereas mechanical valves were an independent adverse risk factor for late mortality. The rates of anticoagulant-related bleeding and thromboembolism were increased by mechanical valves, whereas primary tissue failure was the main complication of homografts. CONCLUSIONS: Long-term outcome of homograft aortic valve replacement in patients with congestive heart failure is acceptable, with a reduced rate of serious complications and cardiac death. Further improvements would be expected if the rate of primary tissue failure could be reduced.

Adolescent↗

Short-term results after aortic valve replacement with stentless xenografts in elderly patients.

OBJECTIVE: Our aim was to chart the short-term results of the first 75 of our patients who had undergone first-time aortic valve replacement (AVR) with stentless xenografts. DESIGN: Our study included a complete follow-up (mean/max. 1.5/3.7 years) of the first 75 patients (42 males, 33 females; mean age 74, range 61-84 years) who underwent a first AVR with stentless xenografts. RESULTS: Forty-three percent of patients were in functional class II and 57% in classes III-IV preoperatively. Coronary artery bypass grafting (CABG) was performed in 33 patients. Early mortality (< or = 30 days) was 6.7%, with no significant relation to CABG or age. Crude survival was 81% (95% confidence interval, CI: 71-91 %) at 3 years. Using a multivariate analysis, we identified a low left ventricular ejection fraction as a predictor of early and late mortality. Late survival (early mortality excluded) was comparable with the survival of a matched Danish background population. There were six embolic events (all cerebral: 3 minor, 1 major, 2 fatal), while two patients underwent redo-AVR because of either endocarditis (fatal) or aortic regurgitation caused by malaligned commissures. There were no other valve-related complications. Cumulative freedom was 89% (95% CI: 79-99%) for embolism and 86% (95% CI: 76-96 %) for all complications at 3 years. At the end of the study, 64% of the survivors were in functional class I, 34% were in class II and 2% in class III. CONCLUSIONS: Considering the age composition of our patients, and compared with international results, our early mortality rates were acceptable. The absence of late excess mortality compared with the background population and the functional status at end-of-study may indicate the potential haemodynamic advantages of stentless aortic valves, at least in the short term.

Aged↗

Changes in left ventricular function and mass during serial investigations after valve replacement for aortic stenosis.

BACKGROUND AND AIM OF THE STUDY: The potential for left ventricular hypertrophy regression and associated functional improvements may well be the underlying mechanism of results in general after valve replacement for aortic stenosis. The study aim was to investigate preoperative predictors and the time course of such ventricular changes. METHODS: Forty-six patients (mean age 61 years; range: 24-82 years) with aortic stenosis were prospectively followed with serial investigations (Doppler echocardiography, radionuclide ventriculography) at eight days (n = 43), three months (n = 42) and 18 months (n = 39) after valve replacement with a mechanical valve (19-29 mm). The postoperative course of left ventricular ejection fraction (EF), fast filling fraction, mass index and end-diastolic volume index (EDVi) was analyzed in an independent increments statistical model for repeated measurements. RESULTS: EF rose marginally, from 59+/-15% preoperatively to 64+/-16% (p <0.05) at 18 months, independently related to preoperative EF (p = 0.0001) and fast filling fraction (p = 0.0001). Changes in fast filling fraction were similarly predicted by the preoperative starting point (p = 0.003) and by preoperative left ventricular systolic radius:wall thickness ratio (p = 0.0002) with an inverse relation (the larger the chamber and the poorer its contractility, the lower the postoperative fast filling fraction). Mass index was independently related to the time point of postoperative measurement, indicating continuing regression of hypertrophy, from 200+/-66 g/m2 preoperatively to 148+/-49 g/m2 at 18 months (p <0.0001), when only 18% of the patients had normal mass index. Mass index was also independently related to preoperative left ventricular end-systolic dimension index (p = 0.0008) with a constant influence, and systolic wall stress (p = 0.0009) which was modified by time: the influence of wall stress was significant at eight days, weak at three months, and pronounced at 18 months. Left ventricular EDVi after surgery was inversely related to preoperative EF modified by time. Associated coronary artery disease, size of the prosthetic valve, and peak gradient across the valve (mean 15 mmHg; range: 7-26 mmHg at 18 months) did not influence any of the four target variables. CONCLUSION: We conclude that left ventricular response to valve replacement for aortic stenosis is predictable. A significant reduction in hypertrophy occurs during the first 18 postoperative months, but to a normal ventricular mass in only a minority of patients. Insufficient regression of hypertrophy was related to indices of irreversible myocardial disease, which also prevented functional ventricular improvement despite successful valve replacement and a hemodynamically well functioning valve.

Aortic Valve Stenosis↗

Primary aortic valve replacement with allografts over twenty-five years: valve-related and procedure-related determinants of outcome.

OBJECTIVES: Allografts offer many advantages over prosthetic valves, but allograft durability varies considerably. METHODS: From 1969 through 1993, 618 patients aged 15 to 84 years underwent their first aortic valve replacement with an aortic allograft. Concomitant surgery included aortic root tailoring (n = 58), replacement or tailoring of the ascending aorta (n = 56), and coronary artery bypass grafting (n = 87). Allograft implantation was done by means of a "freehand" subcoronary technique (n = 551) or total root replacement (n = 67). The allografts were antibiotic sterilized (n = 479), cryopreserved (n = 12), or viable (unprocessed, harvested from brain-dead multiorgan donors or heart transplant recipients, n = 127). Maximum follow-up was 27.1 years. RESULTS: Thirty-day mortality was 5.0%, and crude survival was 67% and 35% at 10 and 20 years. Ten- and 20-year rates of freedom from complications were as follows: endocarditis, 93% and 89%; primary tissue failure, 62% and 18%; and redo aortic valve replacement, 81% and 35%. Multivariable Cox analyses identified several valve- and procedure-related determinants: rising allograft donor age and antibiotic-sterilized allograft for mortality; donor more than 10 years older than patient for endocarditis; rising donor age minus patient age, rising implantation time (from harvest to aortic valve replacement), and donor age more than 65 years for tissue failure; and rising donor age minus patient age, young patient age, rising implantation time, and subcoronary implantation preceded by aortic root tailoring for redo aortic valve replacement. Estimated 10- and 20-year rates of freedom from tissue failure for a 70-year-old patient with a viable valve from a 30-year-old donor and no other risk factors were 91% and 64%; the figures were 71% and 20% if the donor age was 65 years. The rates of freedom from tissue failure for a 30-year-old patient with a 30-year-old donor were 82% and 39%; the figures were 49% and 3% with a 65-year-old donor. Beneficial influences of a viable valve were largely covered by short harvest time (no delay for allografts from brain dead organ donors or heart transplant recipients) and short implantation time. CONCLUSIONS: Primary allograft aortic valve replacement can give acceptable results for up to 25 years. The late results can be improved by the use of a viable allograft, by matching patient and donor age, and by more liberal use of free root replacement with re-implantation of the coronary arteries rather than tailoring the root to accommodate a subcoronary implantation.

Aged↗

Performance profile of the Starr-Edwards aortic cloth covered valve, track valve, and silastic ball valve.

OBJECTIVE: The Starr-Edwards aortic ball valve has passed 30 years of clinical follow-up. A detailed account of the long-term performance from a large series could thus give valuable guidance in managing patients who are still alive, depict the total remaining life-span after aortic valve replacement (AVR) for the average patient, and set a record yet to be matched by modern disc valves. METHODS: A detailed follow-up to a maximum of 31.1 years was performed for 717 patients who underwent their first AVR during 1965-1993 with a Starr-Edwards silastic ball valve (N = 355), a cloth covered valve (N = 164) or a track valve (N = 198) with a total of 7254 patient-years at risk. RESULTS: Patients who received a silastic ball valve were older (average 60 vs. 58 years), had more endocarditis (9%) and more secondary kidney failure (24%) preoperatively than the other patients. The three valve types did not differ as regards long-term survival or freedom from complications and only 15% of late deaths were related to the valve. For the silastic ball valve cumulative freedoms at 10 and 25 years were 59 and 20% from all deaths (crude survival), 85 and 80% from thromboembolism, 87 and 70% from bleeding, 98 and 94% from endocarditis, 96 and 95% from redo AVR and 68 and 51% from all valve related complications joined. There were no instances of structural failure apart from wear of the cloth covering the cage struts of the cloth covered valves. Incidences of haemolysis (0.10%/patient-year) and valve thrombosis (0.06%/patient-year) were low for the silastic ball valve. Analysis of relative survival for the silastic ball valve indicated excess mortality relative to a matched background population only during 1st and 13th postoperative year. Apart from heart related factors and age, independent incremental risk factors for mortality and the various complications included, not valve type, but valve size index (valve size divided by body surface area) < or = 13 mm/m2. CONCLUSIONS: The Starr-Edwards aortic ball valves, not least the currently available silastic ball valve, are durable through the remaining life time of the patients and able to secure near normal age and sex specific survival provided valve and patient size mismatch is avoided.

Adult↗

Recurrence of uterine intravenous leiomyomatosis with intracardiac extension. Diagnostic considerations and surgical removal.

A 28-year-old woman (gravida 2, para 2) was admitted 20 months after a hysterectomy because of fibromyoma. The hysterectomy specimen had shown intravenous leiomyomatosis. The patient presented with unspecific abdominal symptoms, serologic signs of hepatic and renal failure and clinical right-sided heart failure. Progression despite treatment with a gonadotropin-releasing hormone analogue promoted transferral to the present centre. Abdominal ultrasonography, phlebography and transoesophageal echocardiography showed a left pelvic mass and a seemingly free-floating tumour extending from the left main iliac vein via the inferior caval vein to the right ventricle. During a combined cardiac and distal caval approach using extracorporeal circulation, a 45 cm massive leiomyoma was removed successfully. Seven weeks later the left pelvic tumour was removed radically together with left oophorectomy. At control 12 months later the patient was well and without any remaining symptoms.

Adult↗

MatrixPlot: visualizing sequence constraints.

UNLABELLED: MatrixPlot is a program for making high-quality matrix plots, such as mutual information plots of sequence alignments and distance matrices of sequences with known three-dimensional coordinates. The user can add information about the sequences (e.g. a sequence logo profile) along the edges of the plot, as well as zoom in on any region in the plot. AVAILABILITY: MatrixPlot can be obtained on request, and can also be accessed online at http://www. cbs.dtu.dk/services/MatrixPlot. CONTACT: gorodkin@cbs.dtu.dk

Nucleic Acids↗

Stoichiometry of monoclonal antibody neutralization of T-cell line-adapted human immunodeficiency virus type 1.

In order to study the stoichiometry of monoclonal antibody (MAb) neutralization of T-cell line-adapted human immunodeficiency virus type 1 (HIV-1) in antibody excess and under equilibrium conditions, we exploited the ability of HIV-1 to generate mixed oligomers when different env genes are coexpressed. By the coexpression of Env glycoproteins that either can or cannot bind a neutralizing MAb in an env transcomplementation assay, virions were generated in which the proportion of MAb binding sites could be regulated. As the proportion of MAb binding sites in Env chimeric virus increased, MAb neutralization gradually increased. Virus neutralization by virion aggregation was minimal, as MAb binding to HIV-1 Env did not interfere with an AMLV Env-mediated infection by HIV-1(AMLV/HIV-1) pseudotypes of CD4(-) HEK293 cells. MAb neutralization of chimeric virions could be described as a third-order function of the proportion of Env antigen refractory to MAb binding. This scenario is consistent with the Env oligomer constituting the minimal functional unit and neutralization occurring incrementally as each Env oligomer binds MAb. Alternatively, the data could be fit to a sigmoid function. Thus, these data could not exclude the existence of a threshold for neutralization. However, results from MAb neutralization of chimeric virus containing wild-type Env and Env defective in CD4 binding was readily explained by a model of incremental MAb neutralization. In summary, the data indicate that MAb neutralization of T-cell line-adapted HIV-1 is incremental rather than all or none and that each MAb binding an Env oligomer reduces the likelihood of infection.

Acquired Immunodeficiency Syndrome↗

Using sequence motifs for enhanced neural network prediction of protein distance constraints.

Correlations between sequence separation (in residues) and distance (in Angstrom) of any pair of amino acids in polypeptide chains are investigated. For each sequence separation we define a distance threshold. For pairs of amino acids where the distance between C alpha atoms is smaller than the threshold, a characteristic sequence (logo) motif, is found. The motifs change as the sequence separation increases: for small separations they consist of one peak located in between the two residues, then additional peaks at these residues appear, and finally the center peak smears out for very large separations. We also find correlations between the residues in the center of the motif. This and other statistical analysis are used to design neural networks with enhanced performance compared to earlier work. Importantly, the statistical analysis explains why neural networks perform better than simple statistical data-driven approaches such as pair probability density functions. The statistical results also explain characteristics of the network performance for increasing sequence separation. The improvement of the new network design is significant in the sequence separation range 10-30 residues. Finally, we find that the performance curve for increasing sequence separation is directly correlated to the corresponding information content. A WWW server, distanceP, is available at http://www.cbs.dtu.dk/services/distanceP/.

Algorithms↗

[Mortality and worsening of prognosis for patients with aortic stenosis while on the waiting list].

In a prospective study, 99 consecutive patients with an operative indication due to severe aortic stenosis (AS) were put on a surgical waiting list. The waiting time to aortic valve replacement (AVR) averaged 6.3 months (0.5-19 months). There were 58 men and 41 women with a mean age of 61 years (21-82 years). The patients were divided into three groups: group 1 (N = 81) with an uneventful stay on the waiting list; group 2 (N = 11) with significant worsening of a prognostic index; and group 3 (N = 7) with patients who died during the waiting time. The waiting list death rate was 13.5%/patient-year compared with a post-AVR death rate of 4.9% patient-year (p < 0.05) with a mean post-AVR follow-up of 5.7 years. According to a prognostic index (Cox regression model) at inclusion, group 2 patients had a predicted 7-year post-AVR survival probability of 72%, but only of 61% according to their prognostic index immediately preoperatively; their observed 7-year post-AVR survival was 60%. Logistic regression analysis identified high age, short duration of symptoms, signs of severe hypertrophy and strain in the ECG, female gender, and deranged left ventricular diastolic function (related to severely increased left ventricular muscle mass) as independent predictors of prognostic worsening and death while on the waiting list. The predictive models did not allow sufficiently accurate identification of the patients at risk during the waiting period. The consequences of a surgical waiting period averaging 6 months are serious for AS patients. The death rate is high and a subgroup worsens its prognostic profile with a significantly reduced post-AVR long-term survival as the result.

Adult↗

O-GLYCBASE Version 3.0: a revised database of O-glycosylated proteins.

O-GLYCBASE is a revised database of information on glycoproteins and their O-linked glycosylation sites. Entries are compiled and revised from the literature, and from the sequence databases. Entries include information about species, sequence, glycosylation sites and glycan type and is fully cross-referenced. Compared to version 2.0 the number of entries has increased by 20%. Sequence logos displaying the acceptor specificity patterns for the GalNAc, mannose and GlcNAc transferases are shown. The O-GLYCBASE database is available through the WWW at http://www.cbs.dtu. dk/databases/OGLYCBASE/

Amino Acid Sequence↗

NetOglyc: prediction of mucin type O-glycosylation sites based on sequence context and surface accessibility.

The specificities of the UDP-GalNAc:polypeptide Nacetylgalactosaminyltransferases which link the carbohydrate GalNAc to the side-chain of certain serine and threonine residues in mucin type glycoproteins, are presently unknown. The specificity seems to be modulated by sequence context, secondary structure and surface accessibility. The sequence context of glycosylated threonines was found to differ from that of serine, and the sites were found to cluster. Non-clustered sites had a sequence context different from that of clustered sites. Charged residues were disfavoured at position -1 and +3. A jury of artificial neural networks was trained to recognize the sequence context and surface accessibility of 299 known and verified mucin type O-glycosylation sites extracted from O-GLYCBASE. The cross-validated NetOglyc network system correctly found 83% of the glycosylated and 90% of the non-glycosylated serine and threonine residues in independent test sets, thus proving more accurate than matrix statistics and vector projection methods. Predictions of O-glycosylation sites in the envelope glycoprotein gp120 from the primate lentiviruses HIV-1, HIV-2 and SIV are presented. The most conserved O-glycosylation signals in these evolutionary-related glycoproteins were found in their first hypervariable loop, V1. However, the strain variation for HIV-1 gp120 was significant. A computer server, available through WWW or E-mail, has been developed for prediction of mucin type O-glycosylation sites in proteins based on the amino acid sequence. The server addresses are http://www.cbs.dtu.dk/services/NetOGlyc/ and netOglyc@cbs.dtu.dk.

Algorithms↗

Myocardial structure as a determinant of pre- and postoperative ventricular function and long-term prognosis after valve replacement for aortic stenosis.

BACKGROUND: Long-term results after aortic value replacement for aortic stenosis can be correlated to a cardiac-related pre-operative risk profile. This predictability indicates that there is a common basis in subtle or overt structural abnormalities of left ventricular myocardium. METHODS AND RESULTS: Forty-nine patients aged 24-82 (mean 61) years, with aortic stenosis had a full wall thickness transmural biopsy of the left ventricular antero-lateral free wall during aortic valve replacement. Echocardiography and radionuclide ventriculography were performed prior to, and 18 months (n = 41) after, the operation. Postoperative follow-up to a maximum of 7.7 years was 100% complete. Pre-operatively, all patients had an increase in both the left ventricular mass index (202 +/- 67 g.m-2) and the muscle cell diameter (41 +/- 8 microns); other morphological data included a muscle cell nucleus volume of 752 +/- 192 microns3, a muscle cell mass index of 163 +/- 54.m-2, and a fibrous tissue mass index of 39 +/- 16 g.m-2. Patients with a pre-operative episode of clinical left ventricular failure (n = 19) had significantly greater morphological variables than those without. Pre-operative ejection fraction and other measures of systolic function correlated inversely with the morphological data, except for the fibrous tissue mass index; diastolic function indices correlated inversely with all the morphological variables. At the 18-month re-study, the same general picture was noted, but with an underlying strengthening, especially of the muscle cell mass index. Overall, the mass index dropped to 152 +/- 51 g.m-2 (P < 0.0001), but in 17% of the patients it became normal; the mass index at 18 months was directly correlated to morphological variables. A high muscle cell nucleus volume was identified as an independent predictor of early and late mortality. CONCLUSIONS: Abnormalities of the hypertrophied left ventricular muscle cell and the degree of muscle hypertrophy are, to some degree, underlying determinants of pre-operative symptomatology, pre- and postoperative ventricular function, and early and late mortality after valve replacement for aortic stenosis. Incomplete hypertrophy impaired results, was related to pre-operative myocardial structural abnormalities.

Adult↗

O-GLYCBASE version 2.0: a revised database of O-glycosylated proteins.

O-GLYCBASE is an updated database of information on glycoproteins and their O-linked glycosylation sites. Entries are compiled and revised from the literature, and from the SWISS-PROT database. Entries include information about species, sequence, glycosylation sites and glycan type. O-GLYCBASE is now fully cross-referenced to the SWISS-PROT, PIR, PROSITE, PDB, EMBL, HSSP, LISTA and MIM databases. Compared with version 1.0 the number of entries have increased by 34%. Revision of the O-glycan assignment was performed on 20% of the entries. Sequence logos displaying the acceptor specificity patterns for the GalNAc, mannose and GlcNAc transferases are shown. The O-GLYCBASE database is available through WWW or by anonymous FTP.

Algorithms↗