Search PubMed⌕ Search

Biomedical subjects

O Kaii

Publications and source records attributed to O Kaii.

At least 19 recordsLinked to original sources

[Diagnostic accuracy of breast sonography. Comparison among three different techniques].

Mechanical arc scanning is widely used for breast sonography in Japan. The authors have used three different kinds of devices over the past seven years. The diagnostic accuracy was compared among three groups of patients with pathologically confirmed breast masses. In group A, 309 cases (77 carcinomas) were evaluated with a 10 MHz contact compound scanner, and the sensitivity, specificity and accuracy rates were 77.9%, 97.8% and 92.9%, respectively. In group B, 306 cases (56 carcinomas) were evaluated with a 5 or 7.5 MHz mechanical arc scanner, and the sensitivity, specificity and accuracy rates were 89.3%, 84.8% and 85.6%, respectively. In group C, 296 cases (71 carcinomas) were evaluated with a 7.5 MHz real time scanner, and the sensitivity, specificity and accuracy rates were 95.8%, 92.4% and 93.2%, respectively. In cases with T1 breast cancer, the methods had sensitivities of 60.0%, 85.7% and 94.5%, respectively. The sensitivity of the real-time scanner was not significantly different from that of the mechanical arc scanner. In conclusion, the hand-held real-time scanner with high-frequency transducer is a simple, useful device with high diagnostic accuracy for breast examination and can be used as a substitute for the mechanical arc scanner.

Breast↗

Computer-assisted conformation radiotherapy with a variable thickness multi-leaf filter.

A new computer-assisted conformation radiotherapy with a variable thickness multi-leaf filter system was developed. Each wedgeshaped compensating filter (aluminum, tan theta = 0.1) travels against the movement of the ipsilateral leaf and according to defined parameters. By using our filter, a homogenous dose distribution in the target area was obtained and high-dose levels outside the target area decreased significantly.

Filtration↗

[The comparative study of renogram both in case of dehydration and hydration (author's transl)].

In order to study the merit or demerit of the dehydration or hydration as the preparation of renographic examination, the following 25 cases--11 cases of uterine cancer, 2 cases of breast cancer, a case of esophageal cancer, pharyngeal cancer, maxillary cancer, salivary gland tumor, leiomyosarcoma of uterus and others are examined by renography using 131I-hippurate. Renogram is performed in case of patient's dehydration and followed in case of patient's hydration with 600 ml of water intake. Renographic findings such as Tmax, T1/2, HB/HA and step-like pattern are studied as a parameter. Following 600 ml water intake, Tmax is significantly shortened and the step-like pattern is disappeared. This study is strongly suggested that patient's hydration is significantly necessary in the performance of renogram as the preparatory procedure.

Aged↗

[Clinical evaluation of 67Ga-citrate scintigraphy with reference to tumor detectability (author's transl)].

The clinical usefulness of 67Ga-citrate whole body scanning is evaluated in 178 cases of the various diseases in a period of 1976-1978. The cases are 59 cases of thoracic lesions, 41 cases of head and neck lesions, 35 cases of abdominal, bone, and soft tissue lesions, and 43 cases of benign and malignant lymphoma. The clinical results and detectability of various known lesions are shown in tables 1, 2, 3 and 4. The detectability of unknown lesions of malignant lymphoma is shown in table 5. The study demonstrates the particular clinical values of 67Ga-citrate scan in detectability of unknown lesions to be in cases of malignant lymphoma.

Adult↗