In vivo 31P magnetic resonance spectroscopy and 1H magnetic resonance imaging of human bladder carcinoma on nude mice: effects of tumour growth and treatment with cis-dichloro-diamine platinum.

In vivo 31P NMR spectroscopy and 1H NMR imaging were used to examine the bladder T24B carcinoma in nude mice during untreated growth and in response to chemotherapy by Cis-dichloro-diammine-platinum (CDDP) at a dose of 8 mg/kg i.p. Untreated growth was associated with an increase of inorganic phosphate and phosphomonoesters and a decrease of phosphocreatine. Fast growing tumours and early stage of regrowth after treatment presented a higher phosphocreatine/beta NTP ratio. Following CDDP treatment, 31P metabolite ratios and pH were significantly altered compared with age-matched controls, as early as 6 hours after treatment. Although necrotic area was clearly visible in MRI, no treatment effect could be detected on the images of treated tumours.

Animals↗

In vivo measurements of the T1 relaxation processes in the bone marrow in patients with myelodysplastic syndrome. A magnetic resonance imaging study.

Nine patients with myelodysplastic syndrome (MDS) were examined with magnetic resonance imaging and in vivo T1 relaxation time measurements of the vertebral bone marrow in a 1.5 tesla whole body scanner. Two patients underwent transformation to acute myeloid leukemia and were evaluated at follow-up examinations. At the time of diagnosis the T1 relaxation times of the vertebral bone marrow were significantly prolonged compared with normal values. The T1 relaxation times of the vertebral bone marrow in patients with MDS showed significantly lower values compared with patients with acute leukemia and did not differ from patients with polycythemia vera.

Adult↗

Evaluation of biexponential relaxation behaviour in the human brain by magnetic resonance imaging.

Quantitative estimation of individual biologic components in relaxation curves obtained in vivo may increase the specificity of tissue characterization by magnetic resonance imaging. In this study, the potential of biexponential curve analysis was evaluated in T1 and T2 measurements on the human brain at 1.5 tesla. Optimal experimental conditions were carefully observed, including the use of long TR values and a very small voxel size. T1 determination was based on a 12-points partial saturation inversion recovery pulse sequence. T2 determination involved a multiple spin echo sequence with 32 echoes. No genuine biexponentiality was demonstrated in the T1 and T2 relaxation processes of white matter, cortical grey matter, or cerebrospinal fluid. Thus, a monoexponential model seems adequate for description of the relaxation behaviour in these cases. Furthermore, the results suggest that the accuracy of the measurements may not be critically dependent on the voxel size employed.

Adolescent↗

In vivo magnetic resonance imaging and 31P spectroscopy of large human brain tumours at 1.5 tesla.

31P MR spectroscopy of human brain tumours is one feature of magnetic resonance imaging. Eight patients with large superficial brain tumours and eight healthy volunteers were examined with 31P spectroscopy using an 8 cm surface coil for volume selection. Seven frequencies were resolved in our spectra. The spectra from patients with brain tumours showed a great scatter, but generally they overlapped those obtained in normal brain tissue. No characteristic pattern of the spectra was seen in the tumours. One patient with a metastasis from a small cell carcinoma of the lung was examined before and after chemotherapy. The spectra showed considerable changes during chemotherapy. It is concluded that 31P spectroscopy using surface coils is of limited value for tumour characterization, but may add useful information in monitoring the effect of chemotherapy.

Adult↗

In vivo evaluation of femoral blood flow measured with magnetic resonance.

Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein.

Adipose Tissue↗

Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study.

Several circumstances may explain the great variation in reported proton T1 and T2 relaxation times usually seen. This study was designed to evaluate the accuracy of relaxation time measurements by magnetic resonance imaging (MRI) operating at 1.5 tesla. Using a phantom of nine boxes with different concentrations of CuSO4 and correlating the calculated T1 and T2 values with reference values obtained by two spectrometers (corrected to MRI-proton frequency = 64 MHz) we found a maximum deviation of about 10 per cent. Measurements performed on a large water phantom in order to evaluate the homogeneity in the imaging plane showed a variation of less than 10 per cent within 10 cm from the centre of the magnet in all three imaging planes. Changing the gradient field strength apparently had no influence on the T2 values recorded. Consequently diffusion processes seem without significance. It is concluded that proton T1 and T2 relaxation times covering the majority of the biologic range can be measured by MRI with an overall accuracy of 5 to 10 per cent. Quality control studies along the lines indicated in this study are recommended.

Magnetic Resonance Spectroscopy↗

In vivo measurement of water self diffusion in the human brain by magnetic resonance imaging.

A new pulse sequence for in vivo diffusion measurements by magnetic resonance imaging (MRI) is introduced. The pulse sequence was tested on phantoms to evaluate the accuracy, reproducibility and inplane variations. The sensitivity of the sequence was tested by measuring the self diffusion coefficient of water with different temperatures. This phantom study showed that the water self diffusion could be measured accurately and that the inplane deviation was less than +/- 10 per cent. Seven healthy volunteers were studied with a 10 mm thick slice through the lateral ventricles, clear differences between grey and white matter as well as regional differences within the white matter were seen. In two patients with infarction, alternations in water self diffusion were seen in the region of the infarct. Likewise, pronounced changes in brain water self diffusion were observed in a patient with benign intracranial hypertension. The results indicate that brain water self diffusion can be measured in vivo with reasonable accuracy. The clinical examples suggest that diffusion measurements may be clinically useful adding further information about in vivo MR tissue characterization.

Adolescent↗

Determination of flow velocities from magnetic resonance multiple spin-echo images. A phantom study.

The purpose of this study was to evaluate a method for the quantification of through-plane flow velocities by magnetic resonance imaging (MRI) from the flow characteristics of conventional multiple spin-echo (MSE) signals. Simulated inflow-outflow-dependent signals, as well as images of a flow phantom were generated and the logarithm of the flow-dependent signal value was plotted against echo time. The normalized slope of the resulting curve was calculated using a least-square fit to simulated and experimental data and was corrected for T2 relaxation effects by subtraction of a slope obtained at zero flow. After this correction, and with certain restrictions regarding the flow velocity (v), maximum number of echoes in the slope calculation and slice thickness (L), the normalized slope of the MSE signal becomes equal to the quotient v/L, and from this relation the flow velocity can be determined. The validity of the proposed method was examined for different flow velocities and for two opposite flow directions. The influence of the size of the region of interest and the number of spin echoes used in the calculation of the slope on the accuracy of the velocity determination was also studied. The sensitivity of the method to flow-induced phase changes was examined in the phantom by comparing the results obtained with different strengths of the slice-selective gradient as well as by comparing results from even-echo data with those from odd-echo data.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Comparison of different pulse sequences for in vivo determination of T1 relaxation times in the human brain.

Quantitative in vivo determination of T1 relaxation times by magnetic resonance imaging (MRI) is hampered by several potential sources of error. This study focused on the influence of the radiofrequency pulse sequences applied with special attention to the significance of the repetition time (TR). T1 measurements were performed on the human brain using a whole body MR scanner operating at 1.5 tesla. Three different pulse sequences were compared including two 6-points inversion recovery (IR) sequences with TR = 2.0 s and 4.0, respectively, and a 12-points partial saturation inversion recovery (PSIR) sequence with TR varying between 0.24 and 8.0 s. The median T1 relaxation times obtained in cortical grey matter and cerebrospinal fluid were significantly shorter in the IR experiments at TR = 2 s than in those carried out at TR = 4 s. Concerning white matter the discrepancy was much less pronounced, but still statistically significant. Supplementary phantom measurements indicated that the higher T1 values are increasingly underestimated when TR is reduced to 2 s. The results suggest that the PSIR sequence or IR sequences with a TR greater than 2 X the T1 level of the tissue type investigated should be employed for accurate T1 determination by MRI in clinical work.

Brain↗

Chemical shift selective magnetic resonance imaging of the optic nerve in patients with acute optic neuritis.

Optic neuritis is often the first manifestation of multiple sclerosis (MS). Sixteen patients with acute optic neuritis and one patient with benign intracranial hypertension (BIH) were investigated by magnetic resonance imaging, using a chemical shift selective double spin echo sequence. In 3 of the 16 patients, abnormalities were seen. In one patient with bilateral symptoms, signal hyperintensity and swelling of the right side of the chiasm were found. In another patient the optic nerve was found diffusely enlarged with only a marginally increased signal in the second echo. In the third patient an area of signal hyperintensity and swelling was seen in the left optic nerve. In the patient with BIH the subarachnoid space which surrounds the optic nerves was enlarged. Even using this refined pulse sequence, avoiding the major artefact in imaging the optic nerve, the chemical shift artefact, lesions were only shown in 3/16 (19%) of the patients with optic neuritis. Nevertheless, the presented chemical shift selective double spin echo sequence may be of great value for detection of retrobulbar lesions.

Acute Disease↗

Evaluation of biexponential relaxation processes by magnetic resonance imaging. A phantom study.

Despite the complexity of biologic tissues, a monoexponential behaviour is usually assumed when estimating relaxation processes in vivo by magnetic resonance imaging (MRI). This study was designed to evaluate the potential of biexponential decomposition of T1 and T2 relaxation curves obtained at 1.5 tesla (T). Measurements were performed on a phantom of bicompartmental perspex boxes with combinations of different CuSO4 concentrations. T1 determination was based on a 12-points partial saturation inversion recovery pulse sequence. T2 determination was provided by a multiple spin echo sequence with 32 echoes. Applying biexponential curve analysis, a significant deviation from a monoexponential behaviour was recognized at a ratio of corresponding relaxation rates of about 3 and 2, estimating T1 and T2 relaxation, respectively (p less than 0.01, F-test). Requiring an SD less than or equal to 10 per cent for each set of parameters, the biexponential model was accepted when this ratio exceeded a factor of 5 and 8, respectively. Referring to 'expected' T1 and T2 values, however, an accuracy within 20 per cent only was observed at ratios of at least 6 and 15. It is concluded that quantitative estimation of individual and specific relaxation components in complex biologic tissues by MRI may prove very difficult.

Magnetic Resonance Imaging↗

Effect on the content of n-acetylaspartate, total creatine, choline containing compounds, and lactate in the hippocampus of rats exposed to aromatic white spirit for three weeks measured by NMR spectroscopy.

Several epidemiological studies of workers occupationally exposed to white spirit show that neuropsychiatric disorders are a frequent cause of early disability pension in this population compared with non-exposed controls. In the rat, we have demonstrated that exposure to different kinds of white spirit induces changes in neurotransmitter concentrations, indices of oxidative stress, and electrophysiological parameters. Others have confirmed that acute behavioural effects can be induced by short-term high-level exposure. With NMR spectroscopy technique it is possible to study neurochemical parameters in vivo, and to examine the same subjects repeatedly over time. NMR spectroscopy was used to study the effects of organic solvents in rats. Rats were exposed to 0, 400 ppm, or 800 ppm of aromatic white spirit 6 hr/day, 7 days/week for 3 weeks. During the first week, the rats showed signs of irritation of mucous membranes, and appeared to be sedated. Both types of effect gradually diminished during the second week. The rats were examined by single volume of interest (VOI) NMR spectroscopy. N-acetylaspartate, creatinine and phosphocreatinine, and choline containing compounds were measured in the hippocampus and surrounding regions. The concentration of N-acetylaspartate for the three groups was found to be in the range of 8.2-8.5 mM with a standard deviation of 0.6-0.9. There was no difference between the three groups. In a previous study no change in the number of astrocytes in hippocampus was found following exposure to white spirit for six months. Since N-acetylaspartate is thought to be a marker for neurons, the results of these two studies indicate that white spirit does not produce a marked neuronal loss. However, it was not possible to show effect of trimethyltin. In this study trimethyltin was used as a "positive control'. The NMR technique can be applied to the rat, and it is possible to obtain reasonable signal-to-noise ratios.