Effect of dorzolamide and latanoprost on intraocular pressure after small incision cataract surgery.

PURPOSE: To evaluate the effect of dorzolamide 2% and latanoprost 0.005% on intraocular pressure (IOP) after small incision cataract surgery. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective study comprised 102 eyes of 102 consecutive patients scheduled for small incision cataract surgery. The patients were assigned preoperatively to 1 of 3 groups of 34 each: dorzolamide, latanoprost, and control (no treatment). One drop of the assigned medication was instilled immediately after surgery. Intraocular pressure was measured preoperatively and 6 and 20 to 24 hours postoperatively. RESULTS: Six hours after surgery, the mean increase in IOP was 1.9 mm Hg +/- 3.9 (SD) in the dorzolamide group (P = .004 versus control), 2.2 +/- 3.0 mm Hg in the latanoprost group (P = .005 versus control), and 4.8 +/- 5.2 mm Hg in the control group. Twenty to 24 hours postoperatively, IOP decreased a mean of -0.9 +/- 3.5 mm Hg in the dorzolamide group (P = .012 versus control) and increased a mean of 0.3 +/- 3.6 mm Hg in the latanoprost group (P = 0.24 versus control) and 1.3 +/- 4.2 mm Hg in the control group. One eye in the dorzolamide group, 1 eye in the latanoprost group, and 4 eyes in the control group had an IOP of 30 mm Hg or higher 6 hours postoperatively. CONCLUSION: Six hours postoperatively, dorzolamide and latanoprost were effective in reducing the IOP increase after small incision cataract surgery; however, at 20 to 24 hours, only dorzolamide was effective. Neither drug prevented IOP spikes of 30 mm Hg or higher.

Aged↗

Effect of cooled intraocular irrigating solution on the blood-aqueous barrier after cataract surgery.

PURPOSE: To evaluate the effect of cooled intraocular irrigating solution during phacoemulsification on postoperative blood-aqueous barrier (BAB) disturbance. SETTING: Department of Ophthalmology, University of Vienna, Austria. METHODS: In a prospective, randomized clinical study, 40 eyes with senile cataract had phacoemulsification with irrigating solutions cooled to approximately 10 degrees C (n = 20) or at room temperature (n = 20). Surgical procedure and postoperative therapy were otherwise identical in both groups. Postoperative BAB disturbance was assessed with the laser flare-cell meter on days 1, 3, 7, 14, and 28. RESULTS: Anterior chamber flare was significantly lower in the group with cooled irrigating solution on postoperative day 1. There was no significant between-group difference in flare on any other postoperative day. CONCLUSION: Cooled intraocular irrigating solution reduced immediate postoperative inflammation compared with irrigating solution at room temperature. However, this effect was of short duration.

Aged↗

Acetazolamide-induced cerebral and ocular vasodilation in humans is independent of nitric oxide.

Acetazolamide, a carbonic anhydrase inhibitor, is used orally in the treatment of primary and secondary open-angle glaucoma and induces ocular and cerebral vasodilation. Several in vitro studies have shown that carbonic anhydrase pharmacology and the L-arginine-nitric oxide (NO) pathway are closely related. We investigated the role of NO in acetazolamide-induced vasodilation on cerebral and ocular vessels in 12 healthy subjects in the presence or absence of NG-monomethyl-L-arginine (L-NMMA), a NO synthase inhibitor, and in the presence or absence of L-arginine, the precursor of NO. Acetazolamide was administered after pretreatment with either L-NMMA or placebo and either L-arginine or placebo. Pulsatile choroidal blood flow was assessed with laser interferometric measurement of fundus pulsation. In addition, mean blood flow velocity (MFV) in the middle cerebral artery (MCA) and ophthalmic artery (OA) was measured with Doppler sonography. Acetazolamide increased ocular fundus pulsation amplitude (FPA; +27%, P < 0.001) and MFV in the MCA (+38%, P < 0.001) and in the OA (+19%, P = 0.003). Administration of L-NMMA alone reduced FPA (-21%, P < 0.001) and MFV in the MCA (-11%, P = 0. 030) but did not change MFV in the OA. All hemodynamic effects of L-NMMA were reversed by L-arginine. However, neither L-NMMA nor L-arginine altered acetazolamide-induced changes in cerebral or ocular hemodynamic parameters. The present data indicate that acetazolamide-induced hemodynamic changes are not mediated by NO. Which mediators other than NO are involved in the hemodynamic effects as induced by carbonic anhydrase inhibitors remains to be elucidated.

Acetazolamide↗

Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry.

We report on quantitative measurements of group refractive indices and group dispersion in water and in human ocular media such as the cornea, the aqueous humor, the lens, artificial intraocular lenses, as well as a total value averaged over the media along the axial eye length of normal subjects and pseudophakic patients in vivo using dual beam partial coherence interferometry. Different optical thickness values due to the dispersion of the cornea are demonstrated using two spectrally displaced light sources. The displacement can be used to indirectly calculate the group dispersion of the human cornea in the spectral region between 810 nm and 860 nm. If the object under investigation is dispersive, resolution is limited due to a broadening of the detected signals. This broadening increases with group dispersion, i.e., the extent to which the group refractive index of the medium varies with wavelength and thickness of the tissue under investigation as well as with the spectral bandwidth of the light source. Measurements of the group dispersion in the cornea, lens and vitreous of pseudophakic and normal human eyes, show that the cornea and the lens are more dispersive than water-by a factor of about 5 and 2, respectively-in the investigated spectral region. The cornea is approximately threefold more dispersive than the human crystalline lens, the aqueous humor is less dispersive than water and the group dispersion of all ocular components together, averaged over the axial length of normal and pseudophakic eyes, was only slightly higher compared to that of water. Since the highly dispersive cornea and lens together have only a thickness of about one sixth of that of the axial eye length, it seems that their contribution to the group dispersive effect along the whole axial eye length is only small.

Aqueous Humor↗

Topical fundus pulsation measurements in age-related macular degeneration.

BACKGROUND: The purpose of the present study was to investigate regional fundus pulsations in age-related macular degeneration (AMD) patients with subretinal neovascular membranes. METHODS: Local fundus pulsation amplitudes (FPAs) were measured in 12 patients with AMD with classic neovascular membranes. Measurements were performed directly on the membrane and adjacent to the membrane. FPAs were assessed with a recently developed laser interferometric method. FPA measurements were performed in 12 healthy subjects at similar posterior pole locations. RESULTS: In AMD patients FPAs were consistently lower when measured directly on the neovascular membrane ("inside") than at measurement sites around the membrane ("outside"). The difference in FPA was 26 +/- 3% (mean +/- SEM, range 13-40%, P < 0.0001). In healthy subjects, however, FPAs were significantly higher at the measurement points corresponding to "inside" points (15 +/- 4%, P < 0.0006). CONCLUSIONS: We have shown that FPAs are reduced at classic neovascular membranes in patients with AMD. The mechanism behind this finding remains unclear. Hence, future studies have to ascertain whether this observation is associated with changes in fundus layers or with local choroidal perfusion abnormalities.

Aged↗

Partial coherence interferometry: a novel approach to biometry in cataract surgery.

PURPOSE: To compare biometry performed by an enhanced version of dual beam partial coherence interferometry and applanation ultrasound in a prospective study of 85 cataract eyes to improve refractive outcome of cataract surgery due to a more accurate calculation of intraocular lens power. METHODS: The SRK II formula using ultrasound biometry data was employed. Three months after surgery, partial coherence interferometry biometry was repeated and refractive outcome was determined. Preoperative partial coherence interferometry biometry data were used to determine the refractive power of the intraocular lenses retrospectively and to calculate the possible refractive outcome. RESULTS: Precision of partial coherence interferometry biometry was more than 10 times better than that of ultrasound. Therefore, the possible mean absolute error for postoperative refraction achieved with partial coherence interferometry biometry was 0.49 diopters (compared with 0.67 diopters with ultrasound biometry), resulting in an improvement of 27%. Axial eye length measured with the two techniques differed by a mean of 460 microm. The difference in lens thickness measured with partial coherence interferometry and ultrasound significantly correlated with cataract grade. A mean shortening of 120 microm of axial eye length following cataract surgery was also detected by partial coherence interferometry. CONCLUSIONS: The enhanced version of partial coherence interferometry offers biometry with unprecedented precision (<10 microm) and resolution (approximately 12 microm), therefore improving the refractive outcome in cataract surgery. This noninvasive technique provides a high degree of comfort for the patient, with no need for local anesthesia or pupil dilation and minimized risk of corneal infection.

Adult↗

Reversal of endothelin-1-induced ocular hemodynamic effects by low-dose nifedipine in humans.

BACKGROUND AND PURPOSE: There is evidence that calcium channel blockers may be useful in patients with normal tension glaucoma and vasospastic reactions. We therefore hypothesized that calcium channel blockers may increase ocular blood flow and that there may be a functional antagonism between endothelin-1 (ET-1) and calcium channel blockers in the ocular vasculature. METHODS: This was a randomized, double-blind, three-way crossover study with respect to ET-1 infusions (placebo, 2 ng/kg/min ET-1, and 4 ng/kg/min ET-1) and a randomized double-blind study in two parallel groups with respect to nifedipine (placebo or 5 mg nifedipine). Ocular hemodynamics in the 12 healthy subjects participating in the study was assessed by laser interferometric measurement of fundus pulsation amplitude (FPA) in the optic disc and two-dimensional scanning laser Doppler flowmetry in the optic disc. RESULTS: ET-1 caused a dose-dependent decrease in FPA and flow. With a dose of 4 ng/kg/min a decrease of -18% +/- 5% (p < 0.001) and -17% +/- 5% (p = 0.023) on FPA and flow, respectively, were observed. This effect was completely reversed by nifedipine compared with placebo (FPA, p < 0.001; flow, p = 0.011). However, nifedipine did not affect ocular hemodynamics after placebo infusion. CONCLUSIONS: These results show that nifedipine does not increase optic nerve head blood flow during baseline conditions but reverses ET-1-induced constriction in ocular vasculature at doses that do not affect systemic hemodynamics. This supports the close relation of the therapeutic effect of calcium channel blockers in patients with normal tension glaucoma to the endothelin system. Moreover, the present study provides a strong rationale for a study of low dose nifedipine as a supplementary medication in glaucoma patients.

Adult↗

High precision biometry of pseudophakic eyes using partial coherence interferometry.

PURPOSE: To investigate the applicability of the scanning version of dual-beam partial coherence interferometry (PCI) for measuring the anterior segment and axial length of pseudophakic eyes in a clinical setting and to determine the achievable precision with this biometry technique. SETTING: Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Austria. METHODS: Partial coherence interferometry was performed in 39 pseudophakic eyes of 39 patients after implantation of a foldable acrylic intraocular lens (IOL). RESULTS: Effective lens position (ELP), IOL thickness and lens-capsule distance (LCD) were determined with a precision of 2 to 3 microns; corneal thickness and axial eye length, with a precision of 0.8 and 5.0 microns, respectively. The mean ELP of the IOL was 4.093 mm +/- 0.290 (SD). In 7 eyes (18%), a positive LCD of 68 +/- 40 microns was detected with PCI. Mean corneal thickness was 526.4 +/- 31.5 microns; mean IOL thickness, 791.5 +/- 40.2 microns; and mean axial length, 23.388 +/- 0.824 mm. CONCLUSION: The scanning version of PCI enables high precision (< or = 5 microns) and high resolution (approximately 12 microns) biometry of pseudophakic eyes that is better than conventional ultrasound by a factor of more than 20. For the first time, positive LCD, a possible risk factor for posterior capsule opacification, could be detected and quantified. Furthermore, this technique offers a high degree of comfort for the patient since it is a noncontact method with no need for local anesthesia or pupil dilation and has a reduced risk of corneal infection.

Acrylates↗

Accurate determination of effective lens position and lens-capsule distance with 4 intraocular lenses.

PURPOSE: To measure effective lens position (ELP) of 4 intraocular lenses (IOLs) using high precision and high resolution dual-beam partial coherence interferometry (PCI) and to assess the tendency of these IOLs to produce a lens-capsule distance (LCD), a possible risk factor for posterior capsule opacification. SETTING: Department of Ophthalmology, Vienna General Hospital; Institute of Medical Physics, University of Vienna, Austria. METHODS: In a retrospective study, PCI was used to measure ELP and LCD in 139 pseudophakic eyes of 110 patients with 4 IOLs: acrylic 3-piece IOL (AcrySof MA60BM); silicone 3-piece IOL without a capsular tension ring (PhacoFlex SI30) and with a capsular tension ring (PhacoFlex SI30 and Morcher Type 14); silicone plate-haptic IOL (Staar AA4203VF); and a hydrogel plate-haptic IOL (logel 1103). RESULTS: The ELP and LCD were determined with a precision of approximately 3 to 4 microns. An LCD was detected in 21% eyes with the AcrySof, 20% of eyes with the SI30 without a capsular tension ring, 10% of eyes with a capsular tension ring, 21% of eyes with the Staar, and 17% of eyes with the logel. The LCDs detected by PCI, but not by slitlamp examination, were significantly smaller than those detected by both. CONCLUSION: The amount of LCD detected by PCI was approximately the same with all IOL types (approximately 20%) except the PhacoFlex SI30 with a capsular tension ring (10%).

Acrylates↗

Anterior capsulotomy created by radiofrequency endodiathermy and continuous curvilinear posterior capsulorhexis in a patient with intumescent cataract and primary capsular fibrosis.

A 62-year-old woman with intumescent cataract and primary posterior capsular fibrosis was operated on using two different techniques to create continuous curvilinear capsule openings in the same eye. The biomicroscopic appearance of the edge after continuous tear and radiofrequency endodiathermy capsulotomy were compared.

Anterior Eye Segment↗

Comparative study of corneal topographic changes after 3.0 mm beveled and hinged clear corneal incisions.

PURPOSE: To compare the corneal topographic changes after cataract surgery using 2 types of clear corneal incisions (CCIs). SETTING: Department of Ophthalmology, University of Vienna, Austria. METHODS: This prospective, unmasked, nonrandomized study comprised 64 eyes scheduled for cataract surgery; 29 eyes received a temporal sutureless 3.0 mm corneal beveled CCI and 35 eyes, a temporal sutureless 3.0 mm hinged CCI. Preoperatively and 1 week, 1 and 3 months, and 1 year postoperatively, corneal topography was recorded by computer-assisted videokeratoscopy (TMS-1, Computed Anatomy, Inc.). Data were evaluated by batch-by-batch analyses of the paired differences between these records. The significance of topographic changes was calculated by paired Wilcoxon tests, and group comparisons were made using Wilcoxon tests. RESULTS: In both groups, there was statistically significant horizontal flattening and lower corneal steepening (P < .01). The horizontal flattening decreased between 1 week and 1 year, from -0.6 to -0.3 diopter (D) in the beveled-incision group and -0.7 to -0.4 D in the hinged-incision group. Vertical steepening was significant in the lower corneal region and decreased between 1 week and 1 year, from 0.3 to 0.2 D. Group comparisons revealed significant differences in an oblique lower temporal semimeridian, with 0.1 to 0.3 D more steepening after the hinged incision than after the beveled incision (P < .05). CONCLUSION: There were only minimal differences between beveled and hinged CCIs in surgically induced corneal shape changes.

Cornea↗

Postoperative inflammation after clear corneal and sclerocorneal incisions.

PURPOSE: To compare two standard small incision techniques for cataract surgery--clear corneal incision and sclerocorneal incision--with regard to postoperative disturbance of the blood-aqueous barrier (BAB). SETTING: Department of Ophthalmology, University of Vienna, Austria. METHODS: This prospective comparative study comprised 108 eyes with senile cataract. A clear corneal tunnel incision was made in 53 eyes and a sclerocorneal incision with tunnel preparation in 55. All other surgical procedures and postoperative medication were standardized. Postoperative BAB disruption was measured with a laser flare-cell meter (Kowa FC 1000) in an undilated pupil on 1, 3, 7, 14, 28, 60, and 90 days postoperatively. The values were compared using a two-sided t-test. RESULTS: In both groups, flare and cell values were highest on the first postoperative day. They gradually declined but without recovery of preoperative flare values on day 28. At no time was there a noticeable between-group difference in mean cell and flare values except for flare at day 14 (P = .04). CONCLUSION: Postoperative trauma, measured by the BAB disturbance, was equally low after clear corneal and sclerocorneal incisions.

Aged↗

Long-term course of surgically induced astigmatism after a 5.0 mm sclerocorneal valve incision.

PURPOSE: To study surgically induced astigmatism (SIA) after a sutureless 5.0 mm sclerocorneal valve incision. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This study evaluated SIA in 34 cases of sutureless cataract surgery with a 5.0 mm superior sclerocorneal valve incision and implantation of a poly(methyl methacrylate) intraocular lens. Keratometry was measured with a Zeiss keratometer in all cases preoperatively, and 1 day, 1 week, 1 and 3 months, and 1 and 5 years postoperatively. RESULTS: Surgically induced astigmatism, calculated by Cravy's vector analysis, showed an initial mean with-the-rule shift of 0.35 diopter (D), followed by an against-the-rule shift to a mean of -0.30 D after 1 month. One year postoperatively, mean SIA was -0.46 D. Between 1 and 5 years postoperatively, there was a statistically significant increase in mean SIA calculated by Cravy's vector analysis; SIA increased from -0.46 D after 1 year to -0.76 D after 5 years postoperatively. CONCLUSIONS: A small, although statistically significant, amount of postoperatively induced astigmatism occurred 5 years after a sutureless 5.0 mm sclerocorneal valve incision.

Aged↗

Age dependence of choroidal blood flow.

OBJECTIVE: To investigate the age dependence of choroidal blood flow. DESIGN: A cross-sectional study. SETTING: Department of Clinical Pharmacology, Vienna University. PARTICIPANTS: A total of 130 healthy volunteers between the ages of 19 and 83 years. MEASUREMENTS: Fundus pulsation amplitude (FPA) with a recently developed laser interferometric method, mean arterial pressure (MAP) with an automated oscillometric device, intraocular pressure (IOP) with an applanation tonometer, and ocular perfusion pressure (OPP) as calculated from MAP and IOP. RESULTS: There was a significant correlation of FPA with age r = -0.242 (P = .005). MAP, IOP, and OPP showed a significant positive correlation with age. Multiple regression analysis showed that FPA is associated with age but not with MAP, IOP, or OPP. CONCLUSION: Choroidal blood flow is reduced in older subjects, which argues in favor of an increase in ocular vascular resistance with age. This may be a risk factor in the development of common ocular diseases such as age-related macular degeneration or glaucoma.

Adult↗

Effects of acetazolamide on choroidal blood flow.

BACKGROUND AND PURPOSE: The acetazolamide provocation test is commonly used to study cerebrovascular vasomotor reactivity. On the basis of the effect of a carbonic anhydrase inhibitor in the central nervous system, we hypothesized that acetazolamide may also increase blood flow in the human choroid. METHODS: In a placebo-controlled, randomized, double-blind, three-way crossover design, acetazolamide (500 mg or 1000 mg i.v.) or placebo was administered to nine healthy subjects. The effect of acetazolamide was studied at 15-minute intervals for 90 minutes. Pulsatile choroidal blood flow was assessed with laser interferometric measurement of fundus pulsation. In addition, mean blood flow velocity and resistive index in the ophthalmic artery were measured with Doppler sonography. In a second study in six healthy subjects, we assessed the effect of acetazolamide (1000 mg i.v.) on intraocular pressure. RESULTS: Acetazolamide increased fundus pulsation amplitude in a dose-dependent manner (1000 mg: +33%; 500 mg: +20%; P<0.001, ANOVA). The effect of acetazolamide on MFV (1000 mg: +18%; 500 mg: +8%; P=0.003, ANOVA) and RI (1000 mg: -4%; 500 mg: -2%; P=0.006, ANOVA) was less pronounced but also significant. Acetazolamide did not induce any changes in systemic hemodynamic parameters but significantly decreased intraocular pressure (1000 mg: -37%; P<0.0001). CONCLUSIONS: The present data show for the first time that intravenously administered acetazolamide increases choroidal blood flow in humans. This phenomenon therefore indicates that the acetazolamide provocation test may qualify as a tool to investigate ocular vasomotor reactivity in a variety of ocular diseases. Moreover, the increase in choroidal blood flow after carbonic anhydrase inhibition can be expected to contribute to the therapeutic efficacy of carbonic anhydrase inhibitors in glaucoma.

Acetazolamide↗

Short-term oral pentoxifylline use increases choroidal blood flow in patients with age-related macular degeneration.

OBJECTIVE: To study the ocular hemodynamic effects of a 3-month oral treatment with pentoxifylline in patients with nonexudative age-related macular degeneration. DESIGN: Double-blind, placebo-controlled, randomized, parallel group study. SETTING: Outpatient clinic of the Department of Ophthalmology, Vienna University, Vienna, Austria, that specializes in age-related macular degeneration. METHODS: Forty patients with age-related macular degeneration received pentoxifylline (400 mg 3 times a day orally, n=20) or placebo (n=20) for 3 months. Retinal blood flow was assessed by scanning laser Doppler flowmetry and pulsatile choroidal blood flow was assessed by laser interferometric measurement of fundus pulsation amplitude. MAIN OUTCOME MEASURES: Changes in retinal blood flow and fundus pulsation amplitude. RESULTS: Four patients receiving pentoxifylline and 3 patients receiving placebo discontinued medication because of nausea. In the remaining subjects, the use of pentoxifylline increased ocular fundus pulsation amplitude (P<.001 vs placebo and baseline). The maximum increase was 28% after 3 months. In contrast, retinal blood flow was not changed by the use of pentoxifylline. CONCLUSIONS: A 3-month course of oral pentoxifylline treatment increases choroidal but not retinal blood flow in patients with age-related macular degeneration. These data strongly support the concept that pentoxifylline might be useful in the treatment of age-related macular degeneration. Long-term clinical outcome trials are now warranted to test this hypothesis.

Administration, Oral↗

Noninvasive investigations of the normal ocular circulation in humans.

PURPOSE: To compare the reproducibility of laser interferometric measurements of fundus pulsation, pneumatonometric measurement of pulse amplitude (PA) and pulsatile ocular blood flow (POBF), and Doppler ultrasonic measurements of blood flow velocity in the ophthalmic artery (OA) and the posterior ciliary arteries (PCAs) and to investigate the association of the results obtained with these methods and to characterize ocular hemodynamics during Valsalva maneuver and isometric handgrip. METHODS: All studies were performed in healthy subjects. Fundus pulsation (n = 48), POBF (n = 24), and blood flow velocities (n = 24) were measured at baseline and during the Valsalva maneuver and isometric handgrip. Intraclass correlation coefficients were calculated for test/retest variability, for short-term variability, and for interobserver variability. RESULTS: Intraclass correlation coefficients were between 0.95 and 0.98 for fundus pulsation measurements, between 0.54 and 0.76 for pneumatonometric measurements, between 0.44 and 0.88 for Doppler sonographic measurements in the OA and between 0.32 and 0.60 in the PCAs. There was a high degree of association between pneumatonometric parameters and fundus pulsation amplitude. Valsalva maneuver significantly reduced fundus pulsations, PA, and POBF, whereas isometric handgripping did not change these parameters. CONCLUSIONS: The reproducibility of fundus pulsation measurements was excellent. Reproducibility of pneumatonometric parameters and ultrasonographic measurements in the OA was satisfactory. Reproducibility of ultrasonographic measurements in the PCAs was low. Data obtained during the autonomic stimuli experiments argue against the sole use of systems to measure pulsatile blood flow, if no additional data on flow pulsatility are available. At least in cases when changes in blood pressure are likely to occur the ratio of pulsatile to nonpulsatile blood flow might not be constant and POBF might not be an adequate measure of total ocular blood flow.

Adult↗

Eye elongation during accommodation in humans: differences between emmetropes and myopes.

PURPOSE: The pathophysiology and pathogenesis of myopia are still a matter of controversy. Exaggerated longitudinal eye growth is assumed to play an important role in the development of myopia. A significant correlation between refraction and amount of near-work has been reported. However, current knowledge of changes of axial eye length with accommodation is limited because clinical ultrasound biometry does not provide the precision and resolution required to thoroughly investigate these phenomena. METHODS: Partial coherence interferometry (PCI), a noninvasive biometric technique, uses laser light with short coherence length in combination with interferometry to achieve precision in the micrometer to submicrometer range and resolution of 10 microm. In the present study this technique was used to investigate axial eye length changes in 11 emmetropic and 12 myopic eyes during monocular fixation at the far and near point. In 7 subjects, the contralateral eye has also been measured to investigate interocular differences in eye elongation. RESULTS: All investigated eyes elongated during accommodation. This elongation was more pronounced in emmetropes than in myopes (P < 0.001). Mean accommodation-induced eye elongations of 12.7 microm (range, 8.6-19.2 microm) and 5.2 microm (range, 2.1-9.5 microm), corresponding to a dioptric change of approximately -0.036 D and -0.015 D, were obtained for emmetropes and myopes. No significant difference in accommodative amplitudes between groups (5.1 +/- 1.2 D [range, 3.8-7.1 D] versus 4.1 +/- 2.0 D [range, 1.0-7.1 D]; P = 0.14) was detected. No significant interocular difference in accommodation-induced eye elongation was revealed (P = 0.86). Also, a mean backward movement of the posterior lens pole of 38 microm (range, 9-107 microm) was observed in both study groups. CONCLUSIONS: The detected eye elongation can be explained by the accommodation-induced contraction of the ciliary muscle, which results in forward and inward pulling of the choroid, thus decreasing the circumference of the sclera, and leads to an elongation of the axial eye length. Finally, it was demonstrated that PCI, in contrast to clinical ultrasound, is capable of characterizing eye length changes during accommodation in humans.

Accommodation, Ocular↗