Search PubMed⌕ Search

Biomedical subjects

Nuggehally R Srinivas

Publications and source records attributed to Nuggehally R Srinivas.

At least 19 recordsLinked to original sources

Simultaneous quantitation of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib in plasma by high-performance liquid chromatography with UV detection.

A specific, accurate, precise and reproducible high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous quantitation of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib in human plasma. The method employed a simple liquid-liquid extraction of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib and internal standard (IS, DRF-4367) from human plasma (500 microL) into acetonitirile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). The chromatographic separation was achieved by gradient elution consisting of 0.05 M formic acid (pH 3)-acetonitrile-methanol-water at a flow rate of 1.0 mL/min. The eluate was monitored using an ultraviolet (UV) detector set at 235 nm. The ratio of peak area of each analyte to IS was used for quantification of plasma samples. Nominal retention times of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide, IS and celecoxib were 15.63, 17.20, 21.66, 24.95, 26.27, 30.24 and 32.22 min, respectively. The standard curve for etoricoxib, salicylic acid, valdecoxib, ketoprofen and celecoxib was linear (r2 > 0.999) in the concentration range 0.1-50 microg/mL and for nimesulide (r2 > 0.999) in the concentration range 0.5-50 microg/mL. Absolute recovery was >83% from human plasma for all the analytes and IS. The lower limit of quantification (LLOQ) of nimesulide was 0.5 microg/mL and for etoricoxib, salicylic acid, valdecoxib, ketoprofen and celecoxib the LLOQ was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of QC samples, 0.1, 0.3, 15.0 and 40.0 microg/mL (for all analytes except nimesulide), were in the range 2.29-9.37% relative standard deviation (RSD) and 0.69-10.28% RSD, respectively. For nimesulide the inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.5, 1.5, 15.0 and 40.0 microg/mL, were in the range 3.21-7.37% RSD and 0.97-7.06% RSD, respectively. Accuracy in the measurement of QC samples for all analytes was in the range 91.03-106.38% of the nominal values. All analytes including IS were stable in the battery of stability studies, viz. bench top, autosampler and freeze-thaw cycles. Stability of all analytes was established for 21 days at -20 degrees C. The application of the assay in an oral pharmacokinetic study in rats co-administered with celecoxib and valdecoxib is described.

Animals↗

Analysis of five HMG-CoA reductase inhibitors-- atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin: pharmacological, pharmacokinetic and analytical overview and development of a new method for use in pharmaceutical formulations analysis and in vitro metabolism studies.

A specific, accurate, precise and reproducible high-performance liquid chromatographic (HPLC) method was developed and validated for the simultaneous quantitation of five 3-hydroxy-3-methyglutaryl coenzyme A (HMG-CoA) reductase inhibitors, viz. atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin, in pharmaceutical formulations and extended the application to in vitro metabolism studies of these statins. Ternary gradient elution at a flow rate of 1 mL/min was employed on an Intertisl ODS 3V column (4.6 x 250 mm, 5 microm) at ambient temperature. The mobile phase consisted of 0.01 m ammonium acetate (pH 5.0), acetonitrile and methanol. Theophylline was used as an internal standard (IS). The HMG-CoA reductase inhibitors and their metabolites were monitored at a wavelength of 237 nm. Drugs were found to be 89.6-105.6% of their label's claim in the pharmaceutical formulations. For in vitro metabolism studies the reaction mixtures were extracted with simple liquid-liquid extraction using ethyl acetate. Baseline separation of statins and their metabolites along with IS free from endogenous interferences was achieved. Nominal retention times of IS, atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin were 7.5, 17.2, 21.6, 28.5, 33.5 and 35.5 min, respectively. The proposed method is simple, selective and could be applicable for routine analysis of HMG-CoA reductase inhibitors in pharmaceutical preparations as well as in vitro metabolism studies.

Animals↗

High-performance liquid chromatography method development and validation for simultaneous determination of five model compounds, antipyrine, metoprolol, ketoprofen, furosemide and phenol red, as a tool for the standardization of rat in situ intestinal permeability studies using timed wavelength detection.

A simple, precise, accurate and rugged reversed-phase high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of five permeability model compounds, viz. antipyrine, metoprolol, ketoprofen, furosemide and phenol red. The method was intended to standardize rat in situ single-pass intestinal perfusion studies to assess the intestinal permeability of drugs in the market as well as new chemical entities. Optimum resolution was achieved by gradient elution on a Symmetry Shield C-18 analytical column with the mobile phase consisting of a mixture of aqueous potassium dihydrogen orthophosphate (pH 5.5; 0.01 m) and methanol at a flow rate of 1.5 mL/min. The retention times of antipyrine, metoprolol, ketoprofen, phenol red and furosemide were about 9, 12, 13, 16 and 17 min, respectively. Data acquisition was carried out using a photo diode array detector in the wavelength range 210-600 nm. Extraction of chromatograms was carried out by timed wavelength. Data obtained in all studies indicated that the method was suitable for the intended purpose. The validated method was found to be linear and precise in the working range. Suitability of storage under various conditions and freeze/thaw impact at cold temperature were established to ensure complete sample recovery without any stability issues. Recovery very close to the spiked amounts indicated that the method was highly accurate and suitable for use on routine basis.

Animals↗

Applicability of bioanalysis of multiple analytes in drug discovery and development: review of select case studies including assay development considerations.

The development of sound bioanalytical method(s) is of paramount importance during the process of drug discovery and development culminating in a marketing approval. Although the bioanalytical procedure(s) originally developed during the discovery stage may not necessarily be fit to support the drug development scenario, they may be suitably modified and validated, as deemed necessary. Several reviews have appeared over the years describing analytical approaches including various techniques, detection systems, automation tools that are available for an effective separation, enhanced selectivity and sensitivity for quantitation of many analytes. The intention of this review is to cover various key areas where analytical method development becomes necessary during different stages of drug discovery research and development process. The key areas covered in this article with relevant case studies include: (a) simultaneous assay for parent compound and metabolites that are purported to display pharmacological activity; (b) bioanalytical procedures for determination of multiple drugs in combating a disease; (c) analytical measurement of chirality aspects in the pharmacokinetics, metabolism and biotransformation investigations; (d) drug monitoring for therapeutic benefits and/or occupational hazard; (e) analysis of drugs from complex and/or less frequently used matrices; (f) analytical determination during in vitro experiments (metabolism and permeability related) and in situ intestinal perfusion experiments; (g) determination of a major metabolite as a surrogate for the parent molecule; (h) analytical approaches for universal determination of CYP450 probe substrates and metabolites; (i) analytical applicability to prodrug evaluations-simultaneous determination of prodrug, parent and metabolites; (j) quantitative determination of parent compound and/or phase II metabolite(s) via direct or indirect approaches; (k) applicability in analysis of multiple compounds in select disease areas and/or in clinically important drug-drug interaction studies. A tabular representation of select examples of analysis is provided covering areas of separation conditions, validation aspects and applicable conclusion. A limited discussion is provided on relevant aspects of the need for developing bioanalytical procedures for speedy drug discovery and development. Additionally, some key elements such as internal standard selection, likely issues of mass detection, matrix effect, chiral aspects etc. are provided for consideration during method development.

Animals↗

Determination of rosuvastatin in rat plasma by HPLC: Validation and its application to pharmacokinetic studies.

A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of rosuvastatin (RST), a novel, synthetic and potent HMG-CoA inhibitor in rat plasma. The assay procedure involved simple liquid-liquid extraction of RST and internal standard (IS, ketoprofen) from a small plasma volume directly into acetonitrile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). Mobile phase consisting of 0.05 m formic acid and acetonitrile (55:45, v/v) was used at a flow rate of 1.0 mL/min for the effective separation of RST and IS. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 240 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of RST and IS were 8.6 and 12.5 min, respectively. The standard curve for RST was linear (r2 > 0.999) in the concentration range 0.02-10 microg/mL. Absolute recoveries of RST and IS were 85-110 and >100%, respectively, from rat plasma. The lower limit of quantification (LLOQ) of RST was 0.02 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.02, 0.06, 1.6 and 8.0 microg/mL, were in the range 7.24-12.43% relative standard deviation (RSD) and 2.28-10.23% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.05-112.17% of the spiked nominal values. Both analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. RST was found to be stable for a period of 30 days on storage at -80 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.

Animals↗

Development and validation of a sensitive ELISA for quantitation of Grastim (rhG-CSF) in rat plasma: Application to a pharmacokinetic study.

Grastim is bacterially produced recombinant counterpart of human granulocyte colony stimulating factor (G-CSF). It has biological activity similar to that of endogenous G-CSF. In the present work a sensitive, accurate, precise and enzyme-linked immunosorbent assay (ELISA) for the quantitation of G-CSF in rat plasma was developed and validated. The ELISA method employed a technique in which anti-human-G-CSF was adsorbed onto 96-well maxisorp plates and used to capture the G-CSF in rat plasma samples. The captured G-CSF was then detected using streptavidin-HRP amplification system. Absolute recovery was >90% from rat plasma. The validation includes assessments of method accuracy and precision, range of reliable response, lower limit of quantitation (LLOQ), storage stability (30 days) in rat plasma and assay specificity. The standard curve for G-CSF was linear (R2 > 0.996) in the concentration range 4.88-625 pg/mL. The LLOQ was established at 4.88 pg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 15, 250 and 500 pg/mL, were in the range 3.00-8.66% relative standard deviation (RSD) and 1.03-4.69% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.28-110.79% of the nominal values. The assay shows dilutional linearity and specificity. Stability of G-CSF was established for 30 days at -80 degrees C and through three freeze-thaw cycles. The validated assay was successfully employed for the assessment of pharmacokinetic disposition of G-CSF in rats.

Animals↗

Simultaneous estimation of six anti-diabetic drugs--glibenclamide, gliclazide, glipizide, pioglitazone, repaglinide and rosiglitazone: development of a novel HPLC method for use in the analysis of pharmaceutical formulations and its application to human plasma assay.

This paper describes a convenient method for the separation and simultaneous determination of six anti-diabetic drugs viz., glibenclamide (GLB), gliclazide (GLC), glipizide (GLZ), pioglitazone (PGL), repaglinide (RPG) and rosiglitazone (RGL) in pharmaceutical formulations. Also, the assay has been shown applied to support quantification of the six anti-diabetic drugs in human plasma. The analytes were either injected directly onto the column after suitable dilution (pharmaceutical formulation analysis) or a simple extraction procedure, using acetonitrile, from human plasma spiked with anti-diabetic drugs and internal standard (IS). Ternary gradient elution at a flow rate of 1 mL/min was employed on an Intertisl ODS 3V column (4.6 x 250 mm, 5 microm) at ambient temperature. The mobile phase consisted of 0.01 m formic acid (pH 3.0), acetonitrile, Milli Q water and methanol. Celecoxib was used as an IS. The six anti-diabetic drugs were monitored at a wavelength of 260 nm. The nominal retention times of RGL, PGL, GLZ, GLC, GLB, IS and RGL were 11.4, 13.3, 14.8, 17.6, 20.78, 22.1 and 25.4 min, respectively. The assay developed for formulation analysis was found to be accurate and precise. The calibration curves ranged from 0.1 to 100 microg/mL for all analytes with the exception of GLB, where the range was 0.3-100 microg/mL. The plasma assay was validated for parameters such as specificity, accuracy and extraction recovery. The proposed method is simple, selective and can be extended for routine analysis of anti-diabetics in pharmaceutical preparations and in biological matrices.

Carbamates↗

Validation of a simple HPLC method for DRF-4848, a novel COX-2 inhibitor suitable for pharmacokinetic application in rats.

For pharmacokinetic and toxicokinetic purpose a simple HPLC-UV method has been developed and validated for the estimation of DRF-4848, a novel COX-2 inhibitor in rat plasma. A liquid-liquid extraction was used to extract DRF-4848 and internal standard (IS, DRF-4367) from rat plasma. The analysis was performed on a C(18) column with UV detection at 285 nm. The isocratic mobile phase, 0.01 M potassium dihydrogen ortho phosphate (pH 3.2) and acetonitrile (50:50, v/v) was run at a flow rate of 1 mL/min. The retention times of DRF-4848 and IS were 6.8 and 11.2 min, respectively. Absolute recovery for analyte and IS was >80% from rat plasma. A linear response was observed over a concentration range 0.1-20 microg/mL. The lower limit of quantification (LLOQ) of DRF-4848 was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 1.74-8.70% relative standard deviation (RSD) and 0.75-8.43% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.29-116.51% of the nominal values. Analyte and IS were stable in the battery of stability studies viz., benchtop, autosampler, long-term and freeze/thaw cycles.

4-Butyrolactone↗

Simultaneous quantitation of rosuvastatin and gemfibrozil in human plasma by high-performance liquid chromatography and its application to a pharmacokinetic study.

A simple, sensitive and specific high-performance liquid chromatography method is described for simultaneous determination of rosuvastatin (RST) and gemfibrozil (GFZ) in human plasma using celecoxib as an internal standard (IS). The assay procedure involved extraction of RST, GFZ and IS from plasma into acetonitrile. Following separation and evaporation of the organic layer the residue was reconstituted in the mobile phase and injected onto an X-Terra C(18) column (4.6 x 150 mm, 5.0 microm). The chromatographic run time was less than 20 min using flow gradient (0.0-1.60 mL/min) with a mobile phase consisting of 0.01 M ammonium acetate:acetonitrile:methanol (50:40:10, v/v/v) and UV detection at 275 nm. Nominal retention times of RST, GFZ and IS were 6.7, 13.9 and 16.4 min, respectively. Absolute recovery of both analytes and IS was greater than 90%. The lower limit of quantification (LLOQ) of RST and GFZ was 0.03 and 0.30 microg/mL, respectively. Linearity was excellent (r(2) = 0.999) in the 0.03-10 microg/mL and 0.3-100 microg/mL ranges for RST and GFZ, respectively. The inter- and intra-day precisions in the measurement of RST quality control (QC) samples 0.03, 0.09, 2.50 and 8.00 microg/mL were in the range 2.37-9.78% relative standard deviation (RSD) and 0.92-10.08% RSD, respectively. Similarly, the inter- and intra-day precisions in the measurement of GFZ quality control (QC) samples 0.30, 0.90, 25.0 and 80.0 microg/mL were in the ranges 2.79-6.27 and 0.96-9.69% RSD, respectively. Accuracies in the measurement of QC samples for RST and GFZ were in the range 85.43-107.23 and 84.98-102.35% respectively, of the nominal values. RST and GFZ were stable in the array of stability studies viz., bench-top, auto-sampler and freeze-thaw cycles. Stability of RST and GFZ was established for 1 month at -80C. The application of the assay in an oral pharmacokinetic study in rats co-administered with RST and GFZ is described.

Animals↗

Bioavailability enhancement of poorly water soluble and weakly acidic new chemical entity with 2-hydroxy propyl-beta-cyclodextrin: selection of meglumine, a polyhydroxy base, as a novel ternary component.

The purpose of the present study was to investigate the influence of a polyhydroxy base, N-acetyl glucamine (also know as Meglumine), as a ternary component on the complexation of DRF-4367, a poorly water-soluble and weakly acidic anti-inflammatory molecule, with 2-hydroxypropyl-beta-cyclodextrin (HPbetaCD). The molecular inclusion of DRF-4367 with HPbetaCD alone and in combination with ternary component was aimed at improvement in solubility and, subsequently, dissolution rate-limited oral bioavailability. The solid complexes of DRF-4367 and HPbetaCD with or without meglumine (binary and ternary systems, respectively) were prepared as coevaporated product in different stoichiometric ratios and compared against physical mixture. The formation of inclusion complexes was confirmed by using classical instrumental techniques. Phase solubility studies suggested that meglumine was responsible for solubility improvement via multiple factors rather than just providing a favorable pH. Mechanisms and factors governing solubility enhancement were investigated by using phase solubility and thermodynamic parameters. The complexation of DRF-4367 with HPbetaCD is thermodynamically favored because the Gibbs free energies of transfer of the drug to the cyclodextrin cavity are negative. The solubilization efficiency and stability were further improved while retaining the favorable Gibbs free energies of transfer with the addition of meglumine. Inclusion ternary complex of DRF-4367 with HPbetaCD and meglumine showed significant improvement in dissolution compared with uncomplexed drug and binary system. Moreover, the phenomena of reprecipitation observed with binary system during dissolution could be avoided with meglumine as an enabling ternary component. This improved physicochemical behavior of ternary complex with the novel inclusion of a polyhydroxy base translated into an enhanced oral bioavailability of DRF-4367 compared with either uncomplexed drug or nanosuspension.

2-Hydroxypropyl-beta-cyclodextrin↗

Simultaneous determination of rosuvastatin and fenofibric acid in human plasma by LC-MS/MS with electrospray ionization: assay development, validation and application to a clinical study.

A simple, sensitive and specific LC-MS/MS method for simultaneous determination of rosuvastatin (RST) and fenofibric acid (FFA) was developed and validated with 500 microL human plasma using carbamazepine as an internal standard (IS). The assay procedure involved a simple one-step liquid/liquid extraction of RST and FFA and IS from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto X-Terra MS C-18 column (4.6 mm x 50 mm, 5.0 microm). Separation of RST, FFA and IS was achieved with a mobile phase consisting of 0.05 M formic acid:acetonitrile (45:55, v/v) at a flow rate of 0.40 ml/min. The API-3000LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Positive ion acquisition chromatographic run was used in the present method. Nominal retention times of RST, FFA and IS were 2.35, 4.70 and 2.32 min, respectively. Absolute recovery of RST, FFA and IS was 74, 61 and 69%, respectively. The lower limit of quantification (LLOQ) of RST and FFA was 1.00 ng/ml and 0.50 microg/ml, respectively. Response function was established for the range of concentrations 1.00-50.0 ng/ml and 0.50-20.0 microg/ml for RST and FFA, respectively, with a coefficient of determination (r2) of 0.999 for both the compounds. The inter- and intra-day precision in the measurement of RST quality control (QC) samples 5, 15, 400 and 800 ng/ml, were in the range 8.93-9.37% relative standard deviation (R.S.D.) and 1.74-16.1% R.S.D., respectively. Similarly, the inter- and intra-day precision in the measurement of FFA quality control (QC) samples 0.5, 1.5, 8.0 and 15.0 microg/ml, were in the range 9.78-11.6% relative standard deviation (R.S.D.) and 0.22-17.4% R.S.D., respectively. Accuracy in the measurement of QC samples for RST and FFA were in the range 88.1-108 and 87-115%, respectively, of the nominal values. RST and FFA were stable in the battery of stability studies, viz., bench-top, auto-sampler and freeze/thaw cycles. Stability of RST and FFA was established for 1 month at -80 degrees C. The application of the assay to a clinical study confirmed the utility of the assay.

Acetates↗

Validated HPLC analytical method with programmed wavelength UV detection for simultaneous determination of DRF-4367 and Phenol red in rat in situ intestinal perfusion study.

A simple, precise and accurate isocratic reverse-phase liquid chromatography method with programmed wavelength detection has been validated to quantify DRF-4367 and Phenol red, simultaneously for application in rat in situ single pass intestinal perfusion study to assess intestinal permeability of DRF-4367, a novel cox-2 inhibitor. The method was validated on RP C-18 analytical column. Mobile phase consisted of sodium dihydrogen orthophosphate (pH 3.2, 0.01 M)-acetonitrile-methanol (30:50:20, v/v/v). The developed method has a short run time of 12 min with a flow rate of 1.0 ml/min. The injector volume was set to 20 microl and acquisition was carried out using a PDA detector while processing was done by timed wavelength extraction. The percentage R.S.D. and recovery in all studies indicated that the method was suitable for the intended purpose. The validated method was found to be linear and precise in the working range. Suitability of storage at cold temperature was ensured along with complete sample recovery.

Animals↗

Validation of a simple bioanalytical method for the determination of DRF-6196, a novel oxazolidinone, in mouse plasma: application to a single-dose pharmacokinetic study.

An isocratic simple, specific, sensitive and reproducible high performance liquid chromatography (HPLC) method was developed and validated for the estimation of DRF-6196, a novel oxazolidinone in mouse plasma. This method involves a simple liquid/liquid extraction of DRF-6196 and the internal standard (IS; chlorzoxazone, CAS 95-25-0) from plasma into dichloromethane/ethyl acetate mixture that was evaporated under nitrogen. The HPLC analysis was carried out on an Inertsil ODS 2 column using 0.01 mol/L potassium dihydorgen ortho phosphate (pH 3.2) and acetonitrile (65:35, v/v) as mobile phase. The eluate was monitored using an UV detector set at 266 nm. Ratio of peak area of analyte to IS was used for quantification of plasma samples. The retention time of DRF-6196 and IS were 8.2 and 11.1 min, respectively. The assay was linear (r2 > 0.999) in the concentration range 0.1-50 microg/ml. Absolute recovery for analyte and IS was > 94 % from mouse plasma. The lower limit of quantification (LLOQ) of DRF-6196 was 0.1 microg/ml. The inter- and intra-day precision in the measurement of quality control (QC) samples, 0.1, 0.3, 15.0 and 40.0 microg/ml, were in the range 3.64 to 9.51 % relative standard deviation (RSD) and 0.92 to 6.23 % RSD, respectively. Accuracy in the measurement of QC samples was in the range 88.15 to 106.05 % of the nominal values. The analyte and IS were stable in the stability studies viz., benchtop, autosampler and freeze/thaw cycles. The stability of DRF-6196 was established for 1 month at -80 degrees C. The assay method was successfully applied to a pharmacokinetic study of DRF-6196 in mice.

Acetamides↗

Safety, tolerability, and pharmacokinetics of a capsule formulation of DRF-1042, a novel camptothecin analog, in refractory cancer patients in a bridging phase I study.

The purpose of this bridging phase I study was to characterize the toxicity, pharmacokinetics, and antitumor effects of a capsule formulation of DRF-1042, a novel camptothecin analog, in refractory solid tumor patients. DRF-1042 was given daily for 5 consecutive days for 2 weeks, repeated every 3 weeks at 81 mg/m(2). Adverse events were monitored following NCI-CTC. Blood samples were processed for bioanalysis using a validated high-performance liquid chromatography method. The pharmacokinetics of lactone and total (lactone + carboxylate) forms was determined on days 1 and 12 using a noncompartmental pharmacokinetic method. Pharmacokinetic data with the capsule formulation were compared with previously reported pharmacokinetic parameters with a suspension formulation. Efficacy was evaluated by applying World Health Organization criteria. Six patients received 10 courses of therapy. Thrombocytopenia and diarrhea were dose-limiting toxicities. The upper limit of the area under the curve of DRF-1042 (lactone and total) with the capsule formulation was higher than a suspension formulation at a similar dose on day 1 (lactone: capsule = 8.53 microMxh, suspension = 5.33 microMxh; total: capsule = 393 microMxh, suspension = 176 microMxh) and day 12 (lactone: capsule = 22.1 microMxh, suspension = 6.1 microMxh; total: capsule = 1302 microMxh, suspension = 309 microMxh). The upper limit of the area under the curve of DRF-1042 (lactone and total) was higher under fed conditions (lactone = 15.9 microMxh, total = 605 microMxh) relative to fasted conditions (lactone = 8.53 microMxh, total = 393 microMxh) on day 1. One patient experienced stable disease. The toxicity and pharmacokinetics of the capsule correlated well with the suspension. The recommended phase II dose is 81 mg/m(2).

Adult↗

Metabolism, pharmacokinetics, and protein covalent binding of radiolabeled MaxiPost (BMS-204352) in humans.

MaxiPost [(3S)-(+)-(5-chloro-2-methoxyphenyl)-1,3-dihydro-3-fluoro-6-(trifluoromethyl)-2H-indole-2-one); BMS-204352] is an investigational maxi-K channel opener to treat ischemic stroke. This study reports the disposition, metabolism, pharmacokinetics, and protein covalent binding of (14)C-labeled MaxiPost in healthy male volunteers as well as in dogs and rats. After each human subject received a single dose of 10 mg (14)C-labeled BMS-204352 (50 microCi) as a 5-ml intravenous infusion lasting 5 min, the plasma radioactivity concentrations showed a unique profile, wherein the concentration appeared to increase initially, followed by a terminal decline. The mean terminal t(1/2) of plasma radioactivity (259 h) was prolonged compared with that of unchanged parent (37 h). Furthermore, the extractability of radioactivity in plasma decreased over time, reaching approximately 20% at 4 h after dosing. The unextractable radioactivity was covalently bound to plasma proteins through a des-fluoro-des-methyl BMS-204352 lysine adduct. Unchanged BMS-204352 and minor metabolites were identified in plasma extract following protein precipitation. The recovery of the radioactive dose in urine and feces was nearly complete in 14-day collections (approximately 37% in urine and 60% in feces). The N-glucuronide of the parent was the prominent metabolite in urine (16.5% of dose), whereas the parent was a major drug-related component in feces (11% of dose). Similar disposition, metabolism, pharmacokinetic, and protein covalent binding properties of (14)C-labeled BMS-204352 were observed in humans, dogs, and rats.

Adult↗

Development and validation of a chiral liquid chromatographic method, based on Chiralpak to quantify enantiomers of (+/-)-DRF 2725 in rat plasma: lack of inversion of ragaglitazar (S(-)-DRF 2725) to its antipode in plasma.

A selective, accurate and reproducible high-performance liquid chromatographic (HPLC) method for the separation of individual enantiomers of DRF 2725 [R(+)-DRF 2725 and S(-)-DRF 2725 or ragaglitazar] was obtained on a chiral HPLC column (Chiralpak). During method optimization, the separation of enantiomers of DRF 2725 was investigated to determine whether mobile phase composition, flow-rate and column temperature could be varied to yield the base line separation of the enantiomers. Following liquid-liquid extraction, separation of enantiomers of DRF 2725 and internal standard (I.S., desmethyl diazepam) was achieved using an amylose based chiral column (Chiralpak AD) with the mobile phase, n-hexane-propanol-ethanol-trifluoro acetic acid (TFA) in the ratio of 89.5:4:6:0.5 (v/v). Baseline separation of DRF 2725 enantiomers and I.S., free from endogenous interferences, was achieved in less than 25 min. The eluate was monitored using an UV detector set at 240 nm. Ratio of peak area of each enantiomer to I.S. was used for quantification of plasma samples. Nominal retention times of R(+)-DRF 2725, S(-)-DRF 2725 and I.S. were 15.8, 17.7 and 22.4 min, respectively. The standard curves for DRF 2725 enantiomers were linear (R(2) > 0.999) in the concentration range 0.3-50 microg/ml for each enantiomer. Absolute recovery, when compared to neat standards, was 70-85% for DRF 2725 enantiomers and 96% for I.S. from rat plasma. The lower limit of quantification (LLOQ) for each enantiomers of DRF 2725 was 0.3 microg/ml. The inter-day precisions were in the range of 1.71-4.60% and 3.77-5.91% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. The intra-day precisions were in the range of 1.06-11.5% and 0.58-12.7% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. Accuracy in the measurement of quality control (QC) samples was in the range 83.4-113% and 83.3-113% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. Both enantiomers and I.S. were stable in the battery of stability studies viz., bench-top (up to 6 h), auto-sampler (up to 12 h) and freeze/thaw cycles (n = 3). Stability of DRF 2725 enantiomers was established for 15 days at -20 degrees C. The application of the assay to a pharmacokinetic study of ragaglitazar [S(-)-DRF 2725] in rats is described. It was unequivocally demonstrated that ragaglitazar does not undergo chiral inversion to its antipode in vivo in rat plasma.

Animals↗

Intravenous pharmacokinetics, oral bioavailability and dose proportionality of ragaglitazar, a novel PPAR-dual activator in rats.

Pharmacokinetics of ragaglitazar (a novel phenoxazine derivative of aryl propanoic acid), a potent insulin sensitizing and lipid-lowering compound was studied in Wistar rats. A single dose of 1, 3 or 10 mg/kg of ragaglitazar was given orally to male rats (n=4 per dose level) to evaluate dose proportionality. In another study, a single intravenous bolus dose of ragaglitazar was given to rats (n=4) at 3 mg/kg dose following administration through the lateral tail vein in order to obtain the absolute oral bioavailability and clearance parameters. Blood samples were drawn at predetermined intervals and the concentration of ragaglitazar in plasma was determined by a validated HPLC method. Plasma concentration versus time data were generated following oral and intravenous dosing and pharmacokinetic analysis was performed using non-compartmental analysis. The results revealed that Cmax and AUC(0-infinity) increased more than proportionally to the administered oral doses. As dose increased in the ratio of 1:3:10, the mean Cmax and AUC(0-infinity) increased in the ratio of 1:3.2:13 and 1:3.2:16, respectively. After intravenous administration the systemic clearance and volume of distribution of ragaglitazar in rats were 139+/-30 ml/h/kg and 463+/-51 ml/kg, respectively (mean+/-SD). Plasma concentrations declined mono-exponentially following intravenous administration and elimination half-life (t1/2) was about 2.6 h and not significantly different (p > 0.05) from the value from oral administration. Mean residence time (MRT) values for ragaglitazar were found to be 4.15+/-0.52 h (3.5 to 4.6 h). Absolute oral bioavailability of ragaglitazar across the doses tested was in the range of 68%-93%. In conclusion, ragaglitazar exhibits promising pharmacokinetic properties in rats.

Administration, Oral↗

Evaluation of experimental strategies for the development of chiral chromatographic methods based on diastereomer formation.

The past two decades has seen explosive growth in the field of chirality as illustrated by the rapid progress in the various facets of this intriguing field. Firstly, it is the basic understanding of the importance of chirality and, secondly, the awareness of the therapeutic pitfalls due to failure to recognize chirality that have paved the way for a rejuvenated interest in the field. Needless to say that the impetus for chiral separation advancement and enhancement has been found to be the highest in the past decade and still continues to be an area of high focus. In this regard, both direct and indirect separation approaches have been instrumental in placing into literature stereoselective pharmacokinetic and pharmacodynamic data of plethora of drug racemates. Also, today, the cloud of uncertainty associated with the development of a chiral molecule is a thing of the past because the field is so evolved and numerous options are available for stereoselective analysis. However, the decision to advance either a single enantiomer or a racemate for development has to be made by a rational approach with adequate justification. Although indirect method of chiral separation has been well established with numerous examples of well-documented cases of stereoselective pharmacokinetic data, there is a growing need for a review that provides a strategic overview of considerations and key issues for developing chromatographic methods based on diastereomer formation. This review provides a general framework for the exploratory planning and a definitive game plan for the establishment of chiral methods based on diastereomer formation. Also, it provides an exhaustive list of applications of numerous chiral derivatization reagents that have been used in the generation of stereoselective pharmacokinetic data.

Chromatography↗